Installation & Operation Manual

Similar documents
Installation & Operation Manual

Installation & Operation Manual

OUTDOOR DRINKING FOUNTAINS OPERATIONS MANUAL

LIVIN THE DOG LIFE DRINKING FOUNTAINS INSTALLATION & OPERATION MANUAL

Installation & Operation Manual

Models: FM FM WARNING

Installation Instructions

Cooler Mounted Bottle Fillers

A112408B/S-VR-UBL TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: Technical Assistance Fax:

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

A152.8 Series Barrier Free, Bi-Level, Wall Mounted Drinking Fountain

MERIDIAN MODEL# 3793

PAT BASIN MODEL 9121, 9131, & 9141

SEABREEZE. SeaBreeze Rain Shower System Model #1086-CH Owner's Manual

Model H1011.8/H1011.8HPS Water Cooler

Model 1011/1011HPS Drinking Fountain

A910.8A Remote Water Chiller, 8 GPH A A / A A-220V TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER:

TRU-TEMP VALVE. Tru-Temp Pressure Balance 1/2" Rough-In Valve Owner's Manual 3001-RIV-PB-ORB 3001-RIV-PB-BN 3001-RIV-PB-CH 3003-RIV-PB-ORB

A132.8 Series Barrier Free, Wall Mounted Electric Drinking Fountain

Installation LD3060. OmniDeck Series. Table of Contents Rev. R; ECM Bradley Corporation Page 1 of 10 3/30/11

Installation Instructions / Warranty

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Installation Instructions / Warranty

Installation CRS-2/IR, CRS-3/IR WARNING IMPORTANT. Table of Contents. Express Crescent Lavatory System CRS-Series

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

MEGATRON MODEL 2, 3, 4, and 5

Installation and Maintenance Instructions

Installation IMPORTANT! Bradley Multi-Station Wall Sink

Model Combination Shower Eye/Face Wash

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL A171.8 Series Barrier Free, Wall Mounted Water Cooler

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Cooler Mounted Bottle Fillers

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Sensor Operated AquaAccess Barrier Free, Wall Mounted Water Cooler

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Model 1900 Retrofit Bottle Filler

DISCONTINUED. Installation LD OmniDeck Series. Table of Contents

Installation Instructions / Warranty. Massaud

Installation Instructions / Warranty

Model /8300CRP-8309CRP Shower & Eye/Face Wash

DISCONTINUED. Widespread Lavatory Faucet TL170DD RENESSE. Contents. Installation and Owner s Manual. English Español Français

Model 8300FP Freeze Resistant Combination Shower Eye/Face Wash

Installation LC800. Patient Care Unit, 47", Fixed Water Closet. Table of Contents

Operation Maintenance. Mobile Oil Caddy

? Teflon Tape? 9/16 Fixture Wall Anchors and. ? 9/32 Fixture Wall Anchors and

Installation Instructions / Warranty. PuraVida 15775XX1

Installation Instructions / Warranty. Hansgrohe Single Control Kitchen Mixers

User Manual / Installation Instructions

A171.8-VR & VRB Series Barrier Free, Vandal Resistant & Resistance Button, Wall Mounted Water Cooler

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Installation Instructions

PLEASE READ THIS MANUAL BEFORE USING YOUR APPLIANCE. KEEP THIS MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE.

Installation Instructions Model: EB Single-Lever Lavatory Faucet

1.6 GALLON ONE PIECE TOILET

Installation Instructions

Installation Instructions / Warranty

Terreon Lav Decks WARNING

Model 8330 Stainless Steel Combination Shower Eye/Face Wash

Single Handle Lavatory Faucet

A171.8 Series Barrier Free, Wall Mounted Water Cooler

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

INSTALLATION INSTRUCTIONS. Cubix Widespread Faucet Part #: 3204, 5204, 3304, 5304 HANDLE STYLES

Installation Instructions / Warranty

Models: DB-2-HF, DB-3-HF, DB-4-HF, and DB-5-HF. For Service Information, Call

Ligature Resistant. ADA Compliant

1/7 INSTALLATION INSTRUCTIONS. Rough Installation

Version: 1.1 INSTALLATION GUIDE WATERFALL SHOWER SYSTEM

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Thermometer. Hot Water Inlet. Cold Water Inlet G3600LF

Installation Instructions / Warranty

INSTALLATION ADJUSTMENT SERVICE

Installation Instructions / Warranty. Metris 31060XX XX XX1

FREELANCE ORDERING INFORMATION NOTES T01-D

FFP S700 SERIES. Pull-Out Spray Faucet. Installation guide

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS Refrigerated Bi-Level, Sensor Operated, AquaAccess Barrier Free, Wall Mounted Water Cooler

Installation LVAD2. Table of Contents. Verge Wash Basin LVA-Series with Evero Natural Quartz Material

Installation Instructions / Warranty

Installation LC840. Patient Care Unit, 40", Fixed Water Closet. Table of Contents

ODEON BEFORE YOU BEGIN ORDERING INFORMATION T01-C , 2006 Copyright Kohler China Ltd.,

BARRINGTON PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET K-4327

Features Luxier SP21-SS

Series # 17 3-Hole Widespread Faucet with Push Drain

Model A Pipe Line Strainer 3, 4, 6, 8 & 10 Inch (DN80, DN100, DN150, DN200 & DN250) 175 psi (12,1 bar) General Description.

SAN RAPHAEL PRESSURE LITE VITREOUS CHINA SIPHON JET TOILET

Installation Instructions / Warranty. Starck 10111XX XX XX1

Decor Star 1. Decor Star PL-037-SS

INSTALLATION INSTRUCTIONS. Uptown Contempo Widespread Faucets Part # s: 8880-****, 8881-****

INSTALLATION SETUP AND OPERATING INSTRUCTIONS THERMOSTATIC WATER MIXING VALVE SYSTEM TM-500, TM-550

OUTLET HOT INLET COLD INLET INSTALLATION

WARNING NOTICE. Water supply requires a flowing pressure of at least 20 psi, but no greater than 80 psi. IMPORTANT

Features Decor Star PL-004-SS

INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS

3/4.8 AERODYNE 3/4.8L CLASS FIVE+

Installation Instructions / Warranty

3121FR Pedestal Mounted Drinking Fountain

Transcription:

Installation & Operation Manual Table of Contents Pre-Installation Information...2 Physical Dimensions...4 Rough-In Dimensions...5 Hardware Identification Chart...6 Installation Instructions...7 Step 1: Fixture Installation...7 Step 2: Adjusting Drinking Spout Flow...8 Care and Maintenance...9 Troubleshooting...10 Fixture Assembly Drawings...11 Warranty...14 Willoughby Industries, Inc. 5105 West 78th Street Indianapolis, IN 46268 Toll Free: (800) 428-4065 Local: (317) 875-0830 Fax: (317) 875-0837 MADE IN THE U.S.A.

Pre-Installation Information Installation notice! Check Rough-In location PRIOR to installation Flush lines thoroughly PRIOR to hook-up When installing the Willoughby Industries WODF outdoor drinking fountain: Before step 1 of the installation instructions, ensure that rough-ins are in the correct location. Prior to making final connections to the drinking fountain, all water supply lines MUST BE THOROUGHLY FLUSHED with clean, chemical-free water to remove small debris and any previous flushing chemicals that are inherent with new construction projects. Chemicals used in flushing plumbing systems can attack the bubbler, inline strainer, and internal components of the valve, causing severe damage. Any system flushes using flushing chemicals must be followed by a full flushing with pure water to clear any harsh chemicals remaining in the system. The components listed above WILL BE DAMAGED if the aforementioned debris and/or chemicals are not removed. This damage can only be fixed by replacing the valve, and WILL NOT be covered by the manufacturer s warranty. Installation notice! Check Rough-In location PRIOR to installation Flush lines thoroughly PRIOR to hook-up Page 2

Pre-Installation Information (cont.) Installation notice! When installing the Willoughby Industries WODF or CWBF outdoor drinking fountains or bottle fillers: Any fittings provided by the installer should be made of plastic to electrically isolate the unit from the building or connected plumbing system. The grounding of electrical equipment such as telephones, computers, etc. to water lines is a common procedure. This grounding can cause electrical feedback into a water fountain or similar fixture, causing electrolysis, which results in a metallic taste of the water or an increase in the metal content of the water. This can be easily avoided by using the proper materials as indicated. Installation notice! Page 3

Physical Dimensions 12-1/2" BOLT CIRCLE 4X 9/16" THRU ALL 14-1/2" 4-1/4" 15-7/8" 9-1/2" 7" 3-13/16" 4-3/8" 10-3/4" Figure 1 Physical dimensions. Page 4

Rough-In Dimensions 14-1/2" 4X 9/16" THRU ALL 12-1/2" BOLT CIRCLE DRAIN CONNECTION 1-1/2" SCHED. 40 PVC NOTE: UNIT MUST BE DISCONNECTED AND DRAINED DURING WINTERIZATION, PER THE FOLLOWING RECOMMENDED PRACTICES: SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY STOP AND WATER LINES BY OTHERS) DISCONNECT AND REMOVE IN-LINE FILTER PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS TO ALLOW WATER LINES TO DRAIN WATER SUPPLY CONNECTION 3/8" TUBING (LOCATION IS FLEXIBLE) VALVE ASSEMBLY DETAIL #600285 VALVE CARTRIDGE 1/4" TUBE #980632 INLINE STRAINER 1/4" TO 3/8" PRESS LOCK CONCRETE ANCHORS 4X 1/2"-13 UNC X 4" NOTE: 3/8" O.D. SUPPLY CONNECTION CONCRETE PAD SERVICE SHUT-OFF VALVE (BY OTHERS) 1-1/2" PVC COUPLING OPEN HUB DRAIN TO BE 1-1/2" IPS MINIMUM TO A POROUS GRAVEL FILL OR MAIN SEWER LINE LOCATED BELOW FROST LINE WATER SUPPLY LINE TITLE / DESC.: Willoughby Industries, Inc. Indianapolis, Indiana 2 PLCS: SIZE: MAT'L: TOLERANCES 0.03 A 3 PLCS: 0.015 EXCEPT AS FRACTIONS: 1/32" SCALE: REF.: WILLOUGHBY NOTED ANGLE: 1 1:8 Figure 2 Rough-in dimensions. WODF-1-PET OUTDOOR PET DRINKING FOUNTAIN PART #: P0711-0003 REVISION: ORIG.: BEH 10-08-14 STANDARD A REV.: SHEET: BEH 10-08-14 3 OF 3 Page 5

Hardware Identification Chart 1/4-20 x 1/2" SECURITY SCREW 4500NSS 1/4"-20 x 1/2" PHILLIPS SCREW 800144 1/4"-20 x 2" FLAT HEAD SECURITY SCREW 4509SSN 6-32 x 1/4" SOCKET HEAD CAP SCREW 800157 T27 1/4" PINNED TORX BIT 800115 3/4" NPT BRASS LOCKNUT 600612N Page 6

Installation Instructions Step 1: Fixture Installation 1.) The WODF outdoor drinking fountain is to be mounted on a flat, level surface (concrete or otherwise) with an adequate support structure. 2.) Refer to rough-in detail (Figure 2) for locating plumbing connections. 3.) Install service shut-off valve in water supply line (valve not furnished). 4.) Locate and install drinking fountain using 1/2"-13 x 4" concrete anchors (anchors not furnished). 5.) As noted previously, flush the water supply line with clean drinking water before making final connections to the drinking fountain. 6.) Connect water supply line to inline strainer inside drinking fountain using 3/8" plastic tubing (extra tubing not furnished). Push tube straight into fitting on filter about 3/4" until it reaches a positive stop. Water supply connection must comply with local codes. 7.) Connect fountain drain line to drainage system. Drain is to be 1-1/2" IPS minimum to a porous gravel flll or main sewer line located below frost line. Installer to provide waste trap downstream of drain connection. Drain and waste trap must comply with local codes. 8.) Turn on water supply and check both the water supply lines and drain lines for leaks. Page 7

Installation Instructions (cont.) Step 2: Adjusting Drinking Spout Flow 1.) Remove valve box screws. 2.) Remove valve box cover and pushbutton (together). 3.) Remove spring. 4.) Insert a standard flat-head screwdriver into adjustment opening of valve, as shown in Figure 4. 5.) Rotate screwdriver to adjust until desired flow is achieved. a.) b.) Rotate clockwise to increase flow. Rotate counterclockwise to decrease flow. VALVE BOX COVER w/ PUSHBUTTON SPRING VALVE BOX SCREWS Figure 3 Remove valve box cover. STANDARD SCREWDRIVER (FLAT-HEAD) Figure 4 Adjust flow with screwdriver. Page 8

Care and Maintenance Unit Care Willoughby Industries WODF Outdoor Drinking Fountains are not freeze resistant without the FRV Freeze Resistant Valve option. The unit should be disconnected or shut off rom the water supply and drained during the colder months. For more information, refer to the rough-in detail. In order to ensure adequate flow and cleanliness of water, the inlne strainer in the supply line should be cleaned or replaced regularly. New inline strainers can be ordered using Willoughby Part No. 980632. Stainless Steel Care Stainless Steels are basically alloys of iron and chromium and are corrosion resistant. Stainless steel has a bright surface that is easy to clean and is free from oxides. Therefore, cleaning of stainless steel is relatively simple and easy if done on a regular basis. Frequency of cleaning should depend on the rate at which the fixture becomes dirty. Remember that fresh (soft) deposits of all kinds are relatively easy to remove, while removing older (hard) deposits are much more difficult. Establish a cleaning SCHEDULE. Routine cleaning should involve ordinary soap or detergent and water, applied with a sponge, brush or cloth. Baking soda, borax or any of several non-abrasive commercial cleansing agents can help hasten the cleaning action. After scrubbing, rinse THOROUGHLY and wipe dry. DO NOT use common steel wool, scouring pads, scrapers, wire brushes, files or other steel tools to clean stainless steel. Such items will scratch the surface or leave small particles of iron imbedded in the surface, which will eventually rust and stain the surface - even appearing as if the stainless itself was rusting. Certain chemical compounds, if used on stainless steel, can give the appearance of rust and if allowed to stand for long periods of time, can pit the surface of even stainless. Products containing hydrochloric acid, muriatic acid or potassium hydrochloride can ruin the surface. Page 9

Troubleshooting I. Insufficient Flow A. Ensure the service shut-off valve is fully open (provided by installer). B. Ensure water supply is within the normal operating range of 40-60 psi. 1. If pressure is too low, flow can be drastically reduced. 2. If pressure is too high, the strainer and/or valve may have been damaged. 3. The unit is rated for a maximum range of 30-105 psi. C. Inspect the unit's valve for damage, and replace if necessary. D. Inspect the inline strainer for damage and/or clogging, and clean or replace as necessary. E. Check all fittings and tubing for damage and leaks. Replace components as necessary. II. Unit has problems draining A. Remove any debris from the drain. B. Remove any debris from the PVC pipe and fittings. C. Check and clear the waste trap (provided by installer). Page 10

Page 11 14-1/2" 15-7/8" WILLOUGHBY 12-1/2" BOLT CIRCLE 4X 9/16" THRU ALL 2 PLCS: 3 PLCS: FRACTIONS: ANGLE: 4-1/4" 3-13/16" 0.03 0.015 1/32" 1 4-3/8" Willoughby Industries, Inc. Indianapolis, Indiana TOLERANCES EXCEPT AS NOTED SIZE: SCALE: A 1:5 TITLE / DESC.: MAT'L: REF.: 9-1/2" 7" 10-3/4" WODF-1-PET OUTDOOR PET DRINKING FOUNTAIN A PART #: P0711-0003 REVISION: ORIG.: BEH 10-08-14 STANDARD REV.: SHEET: BEH 10-08-14 1 OF 3

Page 12 7 8 9 10 11 12 3 2 4 5 6 1 20 WILLOUGHBY 17 13 14 15 16 25 23 24 27 22 21 9 19 NOTE: WILLOUGHBY PART #600471-1/4" TUBING NOT SHOWN IN EXPLODED VIEW. ITEM # PART # DESCRIPTION QTY. 1 S200223 WELDED BODY ASSEMBLY 1 2 S200031 RECEPTOR SUPPORT ASSEMBLY 1 3 800144 1/4-20 X 1/2" PHILLIPS TRUSS HEAD SCREW 3 4 320284 PVC THREADED ADAPTER, 1-1/2" 1 5 320280-2.9375 PVC PIPE, 1-1/2" SCHED. 40 X 2-15/16" LONG 1 6 S200033 ADA BOWL - 1-3/4" DEPTH 1 7 600601HE DECK MOUNTED DRINKING FOUNTAIN BUBBLER 1 8 600116 O-RING, #023, BUNA N-70 1 9 600612N HEXNUT, 3/4"-14 NPSM 2 10 320469 NIPPLE, 3/8" NPT X 2.5" LONG 1 11 320091 COUPLING, 3/8" FPT STAINLESS STEEL 1 12 320437 ADAPTER, 3/8" NPTF MALE X 1/4" TUBE PUSH-TO-CONNECT 1 13 380284 DRAIN, 1-1/2" 1 14 380274 GASKET FOR 1-1/2" DRAINS 1 15 380273 DRAIN WASHER, 1-5/8" 1 16 600043 NUT, 1 5/8"-12 THD FOR 1-1/2" DRAIN 1 17 4509SSN 1/4"-20 x 2" FH SECURITY SCREW 1 18 600285 SELF-CLOSING CARTRIDGE, 1.0 GPM 1 19 600286 NUT, CARTRIDGE MOUNTING 1 20 380112 SLEEVE FOR PET FOUNTAIN ADJUSTABLE PUSHBUTTON VALVE 1 21 980142 SPRING FOR PET FOUNTAIN ADJUSTABLE PUSHBUTTON VALVE 1 22 S200228 VALVE BOX COVER 1 23 380113 PUSH PIN FOR PET FOUNTAIN ADJUSTABLE PUSHBUTTON VALVE 1 24 800157 6-32 x 1/4" SH CAP SCREW 1 25 980632 STRAINER, IN-LINE, 1/4 TO 3/8 PRESS LOCK 1 18 26 600471 TUBING, 1/4" O.D. X 0.17" I.D. X 18" LONG 2 27 4500NSS 1/4-20 X 1/2" BUTTON HEAD SECURITY SCREW 3 TITLE / DESC.: PART #: Willoughby Industries, Inc. WODF-1-PET Indianapolis, Indiana OUTDOOR PET DRINKING FOUNTAIN P0711-0003 TOLERANCES 2 PLCS: 0.03 SIZE: MAT'L: REVISION: ORIG.: A BEH 10-08-14 STANDARD 3 PLCS: 0.015 EXCEPT AS FRACTIONS: 1/32" SCALE: REF.: NOTED ANGLE: 1 1:6 A REV.: SHEET: BEH 10-08-14 2 OF 3

Page 13 NOTE: UNIT MUST BE DISCONNECTED AND DRAINED DURING WINTERIZATION, PER THE FOLLOWING RECOMMENDED PRACTICES: SHUT OFF WATER SUPPLY TO FIXTURE (SUPPLY STOP AND WATER LINES BY OTHERS) DISCONNECT AND REMOVE IN-LINE FILTER PRESS AND HOLD PUSHBUTTON FOR 10 SECONDS TO ALLOW WATER LINES TO DRAIN 4X 9/16" THRU ALL 12-1/2" BOLT CIRCLE CONCRETE ANCHORS 4X 1/2"-13 UNC X 4" CONCRETE PAD 1-1/2" PVC COUPLING OPEN HUB DRAIN TO BE 1-1/2" IPS MINIMUM TO A POROUS GRAVEL FILL OR MAIN SEWER LINE LOCATED BELOW FROST LINE 14-1/2" WILLOUGHBY TITLE / DESC.: Willoughby Industries, Inc. Indianapolis, Indiana 2 PLCS: SIZE: MAT'L: TOLERANCES 0.03 A 3 PLCS: 0.015 EXCEPT AS FRACTIONS: 1/32" SCALE: REF.: NOTED ANGLE: 1 1:8 DRAIN CONNECTION 1-1/2" SCHED. 40 PVC WATER SUPPLY CONNECTION 3/8" TUBING (LOCATION IS FLEXIBLE) SERVICE SHUT-OFF VALVE (BY OTHERS) WATER SUPPLY LINE WODF-1-PET OUTDOOR PET DRINKING FOUNTAIN VALVE ASSEMBLY DETAIL #600285 VALVE CARTRIDGE 1/4" TUBE #980632 INLINE STRAINER 1/4" TO 3/8" PRESS LOCK NOTE: 3/8" O.D. SUPPLY CONNECTION PART #: P0711-0003 REVISION: ORIG.: BEH 10-08-14 STANDARD A REV.: SHEET: BEH 10-08-14 3 OF 3

Warranty Willoughby Industries, Inc. warrants to commercial and institutional purchasers only that each unit will be free from defects in workmanship and materials under normal use and service upon the following terms and conditions for a period of one (1) year from date of shipment. This warranty does not cover installation or any other labor charges and does not apply to any components damaged by accident, abuse, improper installation or improper maintenance. This warranty does not cover any installation that did not comply with national, state and local building, plumbing or electrical codes. The warranty is limited to replacing or repairing at manufacturer s option, transportation charges prepaid by the purchaser, any component or part which upon our inspection shall be deemed as defective within the limitations of this warranty. The replacement or repair of defective units as stated in this warranty shall constitute the sole remedy of the purchaser and the sole liability of Willoughby Industries, Inc. Willoughby Industries, Inc. shall not otherwise be liable under any indirect damages caused by defects in the repair or replacement thereof. This warranty only extends to commercial and industrial purchasers and does not extend to any others, including consumer customers of commercial institutional purchasers. This warranty is in lieu of all other warranties, expressed or implied, including implied warranty of merchantability or fitness for a particular purpose or otherwise. Page 14