UV Lamp and Quartz Sleeve Replacement/Maintenance

Similar documents
Instruction Sheet. VIQUA UVMAX Lamp and Quartz Sleeve Replacement

Instruction Sheet DANGER

Instruction Sheet DANGER

BlueBox 1200 RORS. Operating manual PURE WATER ANYTIME ANYWHERE

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Ultraviolet Water Sterilizer Installation and Maintenance Manual

Owner s Manual. Model: Powered by. D4 Validated Models: D4-V _RevAC

BALLAST REPLACEMENT. Contents WARNING INSTALLATION MANUAL

PRE INSTALLATION PROCEDURES

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Model CWA200 Owner s Manual

Ozone + UV Sanitation

PARISIAN ARCHITECTURAL BRASSERIE PENDANT 9

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

UV100E Ultraviolet Air Treatment System

SimplyClear Pressurized Filter Product Manual

Owner s Manual. Models: Plus Models: PRO Models: Powered by H, K H+, K+ PRO10, PRO20, PRO30, PRO _RevAB

20-GALLON PARTS WASHER OWNER S MANUAL

PRECISION PRECISION. Installation and Operating Instructions FLOW. AUTOMATIC REGULATOR

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

PS /2 Inch Angle Grinder Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT.

INSTALLATION & MAINTENANCE

A measured step forward

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Owner s Manual. Filterless UV Air Purifier. This Manual Includes:

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

SERVICE REQUIREMENTS

PRE INSTALLATION PROCEDURES

ATD PEDESTAL FAN INSTRUCTIONS

UV I UNIT030W / UV I UNIT055W

AllClear G2 Series Pressurized Filters Product Manual

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

PRE INSTALLATION PROCEDURES

Refrigerant Recovery Machine. Model No Operating Manual

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

Owner's Manual. Models: 400-USUV-10, 400-USUV- 20, 400-USUV-30. Visit us online at Powered by

Owner s Manual. Model: Powered by. D4, E4, F4 + Models: D4+, E4+, F4+, E4-50+, F4-50+ Validated Models: D4-V, E4-V, F4-V D4-V+, E4-V+, F4-V+

Automatic Water System Pump SERIES

Owner s Manual. Models: PUV -7 PUV -14

ANGULAR TILE DRILL BEAST FB750W OPERATING MANUAL

Fillmore Small Pendant Assembly and Installation Instructions

CF1400 DO NOT RETURN PRODUCT TO PLACE OF PURCHASE. IF YOU HAVE ANY QUESTIONS, CALL OUR TOLL FREE HOTLINE:

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

IMpORTANT SAFETy INSTRUcTIONS

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE YCC-IG EB23D1-12

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

TOWER AIR PURIFIER FOR THE FOLLOWING MODEL : EE-5068

Ultraviolet (UV) Water Treatment System

Owner s Manual. Ultraviolet Water Purification System S80, SM80, SV50

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

NORTH AMERICA. Max Max Max Unit. AR F 120V lbs. NOTE or NOTICE: Information that requires special attention.

Owner s Manual. DO NOT REMOVE FROM UNIT See back cover for vital records

NOTE: THIS APPLIANCE MUST BE INSTALLED SOLELY AND EXCLUSIVELY BY A QUALIFIED TECHNICIAN.

USER'S INFORMATION MANUAL

Specifications: NORTH AMERICA

Four Post Boot & Glove Dryer

Ultraviolet Lights on Daikin Applied Rooftop Systems and Rooftop Air Handlers

C7 Series Split System Uncased Indoor Coils

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

SLT-Series Installation and maintenance instructions

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

Ultraviolet (UV) Disinfection System Model RC8

Ceramic heater FAN. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

WL380 QUICK START GUIDE

Operator s Manual. Model G17-EU (International) Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Installation & Operating Guide

INSTALLATION INSTRUCTIONS

TPP440. owner s guide. air purifier with uv light. air purifier with uv light TP

LED IMPORTANT SAFETY INSTRUCTIONS

WATER STERILIZERS TYPE: AM1; AM2; AM3; AM4; AM5; AM6; AM8; AM10; AM12; AM15

Power-Spin. Drain Cleaner Operator s Manual

Owner s Manual. Powered by. Models: NSF Standard 55 Class B Validated Models: S1Q-PA, S2Q-PA, S5Q-PA, S8Q-PA, S2Q-P/12VDC, S5Q-P/12VDC

INSTALLATION INSTRUCTIONS

REGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models

INSTALLATION INSTRUCTIONS

Operator s Manual. Model G17 Disinfection Soak Station for Hysteroscopes, Cystoscopes and ENT scopes

Installation Instructions

DEL AOP 25 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

gamma pond Ultraviolet Sterilizers

Material Safety Data Sheet U.S. Department of Labor Occupational Safety and Health Administration

AQUA LOGIC S CORONA SERIES UV STERILIZERS

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER

BG6UL. 6 Inch Bench Grinder Assembly & Operating Instructions

portable heater FAN Set up and Operating Instructions

ELECTRIC RADIANT OUTDOOR / INDOOR HEATER

Model: M630-44FDC CAUTION:

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

Document No B1 February Atlantic Ultraviolet Corporation

LED IMPORTANT SAFETY INSTRUCTIONS

1020 Industrial Drive, Orlinda, TN fax

ATD BELT DRIVE DRUM FAN INSTRUCTIONS

ADVANCE Ultraviolet (UV) Water Treatment System

User s Information Manual

Installation as pendant.

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

Transcription:

UV Lamp and Quartz Sleeve Replacement/Maintenance Models: Tap, Tap Plus, Home, Home Plus, Professional, Professional Plus (Excluding, D4, E4, F4, and Plus and Monitored versions) Overview UV Lamp replacement: The amount of UV light created by the UV lamp decreases over time, requiring that the UV lamp be replaced. The system will automatically notify you when it is time to replace the UV lamp. Quartz Sleeve replacement/maintenance: Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing disinfection performance. If the quartz sleeve can not be cleaned, it must be replaced. Section 1 Safety Information Please read this entire instruction sheet before operating this equipment. Pay attention to all danger, warning, and caution statements in this instruction sheet. Failure to do so could result in serious personal injury or damage to the equipment. Make sure that the protection provided by this equipment is not impaired. Do not use or install this equipment in any manner other than that specified in the instruction sheet. 1.1 Safety Precautions DANGER Failure to follow these instructions will result in serious injury or death. Shock Hazard - Stored Energy Disconnect power to system before performing any maintenance or repair. There may be more than one source of power. Only connect to a GFCI. Protective ground DO NOT touch with wet hands. Pressurized Device - Impalement Hazard NEVER perform any physical inspection, repair or maintenance on UV chamber unless UV chamber has been isolated and depressurized. NEVER service UV lamps, quartz sleeves or associated hardware until depressurization of UV chamber has been confirmed. DO NOT store any combustible or flammable material close to the system. 520183-R_ RevG

Safety Information WARNING Failure to follow these instructions could result in serious injury or death. UV Light Hazard ALWAYS use UV protective gear, including gloves and UV safety glasses. NEVER look directly at illuminated UV lamp, even when using protective gear. NEVER illuminate UV lamp outside of the UV chamber. If accidental exposure occurs, immediately cool affected area and consult physician. Contamination Hazard If UV lamp breaks, avoid inhalation, ingestion, or exposure to eyes and skin. Wear appropriate clothing and personal protective equipment. NEVER use a vacuum cleaner to clean up broken UV lamps as this will scatter the mercury. Obey local regulations and guidelines for the removal and disposal of mercury waste. WARNING: This product can expose you to chemicals including Phthalates, which are known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.p65warnings.ca.gov. CAUTION Failure to follow these instructions could result in minor or moderate injury. Thermal Hazard Allow UV lamps, UV chamber to cool for a minimum of 10 (ten) minutes before handling. When there is no water flow, the water in the chamber will become hot. To prevent scalding, allow the system to cool for 10 minutes before draining the system. Personal Injury Hazard UV lamps and quartz sleeves are fragile. Do not strike, bend or apply pressure, or they will break. DO NOT handle UV lamps or quartz sleeves with bare hands. Wear rubber or latex gloves to handle previously installed UV lamps and soiled quartz sleeves to protect against contaminants. Wear cotton gloves to handle new UV lamps and clean quartz sleeves. Hg Exposure The UV lamp contains mercury. If the lamp breaks, then avoid inhalation or ingestion of the debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a broken lamp as this may scatter the spilled mercury. Obey local regulations and guidelines for the removal and disposal of mercury waste. Avoid Injury NOTICE Read and understand this Instruction Sheet before operating and performing any maintenance on this equipment. System Protection To protect the Controller, a UL 1449 certified (or equivalent) transient voltage surge suppressor is strongly recommended. 2

Maintenance Section 2 Maintenance WARNING Always disconnect power before performing any work on the disinfection system. Always shut-off water flow and release water pressure before servicing. Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection. Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures. 2.1 Replacing UV Lamp Do not use water during replacement of UV lamp. NOTICE The amount of UV light created by the UV lamp decreases over time, requiring that the UV lamp be replaced. The system will automatically notify you when it is time to replace the UV lamp. Note: Not applicable to TAP systems. Procedure: Close main water supply to the UV System, and then open a tap downstream of the UV System to release pressure. Disconnect main power source and allow the unit to cool for 10 minutes. Note: Ensure there is no other power source connected such as, Solenoid Junction Box. Remove the UV lamp connector. Note: Follow illustration that shows your specific connector. Remove the UV lamp. Re-insert the new UV lamp inside the quartz sleeve. Attach the connector to the UV lamp and note that the connector will only allow correct installation in one position. Place and tighten the UV lamp connector. Follow illustration that shows your specific connector. Plug the unit back to the power source. Reset the end of lamp timer alarm back to 365 days. Note: Not applicable to TAP systems. Open the inlet valve slowly. Close the downstream tap once the UV chamber is filled with water, and inspect for any leakages. 3

Maintenance 2.2 Cleaning and Replacing Quartz Sleeve Note: Minerals in the water slowly form a coating on the quartz sleeve. This coating must be removed because it reduces the amount of UV light reaching the water, thereby reducing disinfection performance. If the sleeve can not be cleaned, it must be replaced. Prerequisites: Shut off water supply and drain all lines. Remove the UV lamp. Refer to Section2.1. Procedure: All models: Remove the top retaining nut and O-ring. Remove the bottom retaining nut, Spring and loosen the O- ring to drain the water. Note: Ensure that the quartz sleeve does not slide through. Remove the quartz sleeve from the UV chamber. Clean the quartz sleeve with a cloth soaked in CLR, vinegar or some other mild acid and then rinse with water. All models: Re-insert the quartz sleeve with O-ring(s), Spring, and retaining nut(s). Hand tighten the retaining nut(s), taking care not to over-tighten. When service is complete, assemble the prerequisites in the reverse order of disassembly. Perform the disinfection procedure. Refer to Owners Manual. 4