Instruction Manual GP110 GelPump

Similar documents
Instruction Manual Savant DNA120, DNA120 OP SpeedVac Concentrator

Integrated SpeedVac System SPD1010/SPD2010 INSTRUCTION MANUAL

NapCOIL. UF 400/500/650 Users Manual Rev. 1 ( d) Analyze Detect Measure Control

Heto PowerDry LL1500 Freeze Dryer

EQUIPMENT Operation Manual

CENTRIVAP CENTRIFUGAL CONCENTRATORS & COLD TRAPS

CentriVap. Centrifugal Vacuum Concentrators and Cold Traps

Chemical resistant Vacuum Pumps

EQUIPMENT Operation Manual

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Centrifugal Evaporators

Condensate Pump. Installation and Safety Instructions CP-16 CP

CentriVap Centrifugal Concentrators and Cold Traps

OPERATING MANUAL MANUAL WATER BASE GUN CLEANERS UM120W UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OWNER S MANUAL FOR AIR ADMIRAL VACUUM/PRESSURE STATION MODELS:

OWNER S MANUAL FOR DRY VACUUM PUMPS MODELS: / / / 2047

Model: C C Ambassador 20. Automatic Carpet Scrubber OPERATION SERVICE PARTS CARE

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

High Output Vacuum/Pressure Pump

Labconco Small Stoppering Chamber

Corning LSE Digital Dry Bath Heater

TFC 400. OPERATOR MANUAL Clarke MODEL /09 Rev C Document Number

Cavitator Ultrasonic Cleaner Instruction Manual Model 20G

OWNER S MANUAL FOR DRY VACUUM PUMP MODELS: 2567B-01, 2567B-50, 2567C-02, 2567C-50

V LPM Desiccant Air Dryer Installation and Operation Manual

OPERATING MANUAL AUTOMATIC SPRAY GUN CLEANERS UG7500 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

Centrifugal Vacuum Concentrators and Cold Traps

OWNER S MANUAL FOR CHEMSTAR DRY MODELS: 2070, 2080

USER MANUAL UN-200V / UN-200VH

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

Desiccant / Pump Dehumidification System. Model Operating Manual

1/24/01 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

OWNERS MANUAL MODEL EXTERMINATOR VS900 C/R BLACK VAPOR CLEANING SYSTEM SAFETY INSTRUCTIONS OPERATIONS CARE AND MAINTENANCE TROUBLESHOOTING WARRANTY

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

Pos-D Positive-Displacement Pipette for Problem Liquids

Freeze Dry Systems and Accessories

Instruction Manual. Bucket Oil Pump

Tank, Heater, and Control Operation Manual REV. E DATE: 04May2015

Freeze Dry Systems and Accessories

User Manual. Twin Piston Vacuum Pumps: Oil-less WVP Series: WVP12, WVP10, WVP5, WVP4, WVP3, and WVP2

PRODUCT MANUAL. TT-MTM2 Hard-Wired Controller with Remote

Thermo Scientific Modulyo Freeze Dryers

OPERATING MANUAL SPRAY GUN CLEANERS UG UG3000 SERIES UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2019

Operation and Maintenance Manual

RecoverX Oil-Filled Hermetic Refrigerant Recovery System. Operation and Maintenance Manual

AUC Cell Washer. User Manual

Parts and Service Manual BURNISHER MODEL: MR , MR , MR , MR

92831 TEL: (714) FAX:

OWNER S MANUAL FOR ASPIRATION / FILTRATION VACUUM SYSTEM MODELS: 2511 & 2515

OWNER S MANUAL FOR DRY VACUUM PUMP MODEL: 2581

5300, 5300CH, 5300EX, 5300FN

RecoverX-CAR Contaminated Automotive Refrigerant Recovery System Operation and Maintenance Manual

Owner s Manual. Terpene Trap CF 1000

Cavitator Ultrasonic Cleaner Instruction Manual

Reacti-Therm I and III Heating Modules

OPERATING MANUAL SPRAY GUN & PRESSURE POT CLEANERS UG4000 & UG6000 SERIES, UPP6500E UNI-RAM CORPORATION ONTARIO CANADA PATENTS

OPERATING MANUAL SOLVENT SPRAY GUN CLEANERS UG5000E, UG5000DVM AND UG5500E UNI-RAM CORPORATION ONTARIO CANADA PATENTS

55-Gallon Dispenser Package

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

OPERATING INSTRUCTIONS

Air Pump Up to 800 gallons

Essential Equipment for Advanced Laboratory Use. Rotary Evaporator TOKYO RIKAKIKAI CO., LTD.

Please Read and Save These Instructions.

Master Pop. Instruction Manual. Cincinnati, OH USA. Model No. 2451, 2451EX. Part No.49659

USER S OPERATING AND INSTRUCTION MANUAL

USER MANUAL SPRAY GUN CLEANER - WATER BASED PAINTS UA400W CAUTION FOR WATER BORNE PAINTS ONLY

IQ/OQ Protocol Installation Qualification/ Operation Qualification

Models Goldfisch Fat Extraction Apparatus

1909/1910 QUICK START GUIDE. Simpler Soil Water Samplers 02/2018. Fig. 1 - Model 1910LL Fig. 2 - Model 1910PL Fig. 3 - Model 1909L

LS-JRE OPERATION & INSTRUCTION MANUAL

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Aluminum Heating Mantles

CENTRIFAN PE. Evaporation the Easy, Environmental Way. Reliable Results for Small Samples. Small Volume Evaporator GREEN.

Digital Heat Block User Manual

Owner & Operator s Manual. Table of Contents

OPERATING INSTRUCTIONS

Ultrasonic Humidification System Model 5462 & Model 5472 OPERATING MANUAL

UPP7500E2 AUTOMATIC PRESSURE POT CLEANER

Cavitator Ultrasonic Cleaners

Thermo Scientific Air Cadet

OPERATING MANUAL 12 AXIAL FANS

IQ/OQ Protocol Installation Qualification/ Operation Qualification

Reacti-Therm I and III Heating/Stirring Modules

BA2702-P Linear Actuator

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

MiniWAVE Microwave Digestion Made Easy

Laboratory Diaphragm Pumps for Air Gases Liquids

17 GALLON PROFESSIONAL RESTROOM CLEANER

CORNADO POPPING UNIT 36 & 48 oz. Domestic Units Instruction Manual

HydroSpeed plate washer for 96- and 384-well formats

Operation Manual SA Vent. Models Kona, Pali and Mistral

DRY-PAK INDUSTRIAL AIR DRYER Installation and Instruction Manual

THE MW-1 Cyclone RECORD CLEANING MACHINE

Boekel Microplate Incubator

WARNING: FOR OUTDOOR USE ONLY

Safety, Operation and Maintenance Manual with Parts List

RK / RK Methane Detector Operator s Manual

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE

SVF-8DC. Manual No. BLWR007 Rev. 3 February 2014

Transcription:

Instruction Manual GP110 GelPump TM 100-3000-00 Rev. D

Table of Contents Section Section Title Introduction Page 1.0 Introduction-GP110 2 Figure 1. GP110 2 Figure 2. GP110 with DTK120R 2 Section Section Title Installation Page 2.0 Installation 3-4 Section Section Title Operation Page 3.0 Operation 4 Section Section Title Maintenance Page 4.0 Maintenance 4 Section Section Title Reconfiguration Page 5.0 Reconfiguration 4 Section Section Title Specifications Page 6.0 Specifications 5 Section Section Title Warranty and Page Liability 7.0 Warranty and Liability 5 SPEEDVAC, VAPORNET, AND CRYOCOOL ARE REGISTERED TRADEMARKS OF THERMO ELECTRON CORPORATION. SPEEDVAC CONCENTRATOR IS PROTECTED UNDER U.S. PATENT NUMBER 4,226,669. VAPORNET IS PROTECTED UNDER U.S. PATENT NUMBER 5,137,604, SUB-PATENT NUMBER 5,263,268, AND GERMAN PATENT NUMBER P41 13 174.6-16. TEFLON IS A REGISTERED TRADEMARK OF E.I. DuPONT de NEMOURS & CO. ALL REGISTERED TRADEMARKS ARE PROPERTY OF THEIR RESPECTIVE COMPANIES. 2000-2003 THERMO ELECTRON CORPORATION.

1.0 INTRODUCTION The Thermo Electron GP110 GelPump TM is a low maintenance, oil-free vacuum pump specifically designed for use with gel drying apparatus and a variety of other applications requiring vacuum. Vacuum is provided by an oil-free, modified diaphragm pump. A patented liquid/vapor separator prevents liquids from entering the pump. Liquids are collected and vaporized allowing non-damaging vapors to pass through the pump. A large, 1L recovery vessel at the pump s exhaust port collects the condensed vapors. The oil-free design and Teflon coated vapor path of the GP110 deliver maximum reliability and reduced maintenance. Porous Muffler Vacuum Inlet Recovery Vessel Figure 1. GP110 On/Off Switch Figure 2. GP110 with DTK120R attached 2

2.0 INSTALLATION Contact Thermo Electron with any shipment problems. Receiving. damage. Call Thermo Electron if shipping carton shows any visible sign of Unpacking. Carefully remove the instrument, loose accessories and paperwork from the shipping carton. Lift and carry holding securely underneath with both hands. Use proper lifting technique (lift with the legs, not the back) to avoid personal injury. Compare the contents with the packing list and call Thermo Electron if there is a discrepancy. Inspection. Inspect the unit for any damage that may have occurred during shipment. Should there be any damage, report it to the carrier and contact Thermo Electron immediately. Make sure the carrier inspects the damage and leaves an inspection report. Register any claims for shipping damage against the carrier or its agent. Save the shipping carton in the event a return is necessary. Set-up. The GP110 arrives fully assembled. The user need only attach the subassemblies according to the following procedure (see fig 1; page 2). Connect a piece of vacuum tubing to the pump vacuum inlet located on the left side of the pump. For ease, of connection, apply a small amount of vacuum grease to the barbed fitting. It is not necessary to use hose clamps. Read Reconfiguration (section 5.0) before removing or modifying this tubing. Route the vacuum tubing to the apparatus requiring vacuum. If the GP110 is a component of the GDS100, GDS101 or the GDS300 Gel Drying System, the GDS Instruction Manual describes where to locate the GP110 and how to attach the vacuum tubing. If the GP110 is part of the GDS300 Gel Drying System, the pump should be connected to the outlet on the rear of the GDS300. CAUTION: Before connecting the GP110 to an outlet, check voltage, frequency, and amperage to be sure they match the power requirements indicated on the label on the instrument (120V / 60Hz, 6A or 230V / 50Hz, 3A). If unsure, please consult an electrician. Vacuum Pump Exhaust. All liquid solvent and solvent vapors that enter the vacuum pump from the gel dryer must be exhausted from the pump. The exhaust port is located on the right side of the pump and is connected, with blue tubing, to the large, 1L, exhaust recovery vessel. The recovery vessel collects the condensate and allows for the safe disposal of recovered solvents. Acid-neutralizing chemical (ANC100) can be used to neutralize the acid and reduce the strong odor of acetic acid. Use 3 teaspoons or 7 mm of ANC100, dispensed evenly on the bottom of the recovery vessel. The recovery vessel must be vented to prevent pressure build-up and a potentially dangerous condition. The recovery vessel is opened to atmosphere through a porous muffler. 3

Other exhaust recovery methods. The blue tubing can be disconnected from the inlet port on the recovery vessel and connected to a larger vented recovery vessel positioned below the exhaust port on the vacuum pump. Drying gels containing radiolabeled biomolecules. If the GP110 is used for drying gels containing radiolabeled biomolecules, test the liquid collected in the recovery vessel for radioactivity. If radioactivity is detected, attach an optional D T K 1 2 0 R Chemical Trap to the vent port (remove porous muffler) on the exhaust recovery vessel (See Fig. 2, page 2)Any volatile radioactivity coming through the pump and venting from the recovery vessel will pass through the chemical trap and be adsorbed by the activated carbon. It will be necessary to periodically swab test the exhaust port on the chemical trap and change the disposable cartridge when break through radioactivity is detected. 3.0 OPERATION To begin operation, activate the GP110 using the power switch on the front of the unit. When used in the GDS300 Gel Drying System, leave the GP110 switched ON so that the external switch on the GDS300 can control the pump's operation. 4.0 MAINTENANCE It is important to keep the white porous muffler clean and open to atmosphere to ensure that the pump can exhaust air and to prevent back pressure and a potentially dangerous condition. EMPTY THE EXHAUST RECOVERY VESSEL Periodically empty the condensate from the recovery vessel. Unscrew and remove the vessel and dispose of its contents in an environmentally safe manner. Add 1 teaspoon of fresh acid-neutralizing chemical, as required, and screw the receptacle back onto the lid. The recovery vessel can be emptied during gel drying since it does not effect the vacuum. **NOTE: It is the responsibility of the user to dispose of ALL materials in a manner in accordance with all federal, state and local regulations. It is recommended to run the GP110 an additional 10 minutes prior to and after each run to remove any residual condensation from the pump head. 5.0 RECONFIGURATION To disconnect tubing, pull straight off of fitting. DO NOT twist the tubing to remove it as this may damage or loosen the fitting causing a vacuum leak. If the tubing does not come off when pulled, carefully slit the existing tubing at the plastic fitting (avoid scoring the fitting). Remove the tubing and discard it. 4

6.0 SPECIFICATIONS (Subject to change without notice) Displacement: Maximum Vacuum: Weight: Dimensions: 36 L/min (60 Hz), 30 L/min (50 Hz) 7 torr (9 mbar) 31 lbs. (14 kg) 13 in. x 11 in. x 12 in. (W x D x H): (33 cm x 27 cm x 29 cm) Power Requirements: Registration: Accessories: 120VAC/60 Hz, 6A 230VAC/50 Hz, 3A ISO 9001-1994. Registered by QMI (Quality Management Institute). Certificate number 001080. RV1000 GTP100 ANC100 DTK120R Large volume (1000 ml) recovery vessel Gel Tubing Package consisting of inert, wide bore tubing (0.5 I.D.) with polypropylene fittings, bleeder valve and vacuum gauge for connecting the GP110 GelPump to a Thermo Gel Dryer. Acid Neutralizing Chemical (1 cup) Chemical Trap kit for adsorbing volatile radioactivity. 7.0 WARRANTY AND LIABILITY All Thermo Electron products mentioned in this manual (except glassware) are warranted against defects in material and workmanship for one year after the date of delivery to the original purchaser. Thermo s warranty is limited to defective materials and workmanship. Warranty work is subject to our inspection of the unit. No instruments, equipment, or accessories will be accepted without a Return Material Authorization (RMA) number issued by Thermo. The warranty obliges you to follow the precautions in this manual. Under no circumstances shall Thermo be liable for damages due to the improper handling or use of its products. Thermo assumes no liability, express or implied, for your use of this equipment. 5

Thermo Electron Corporation Bioscience Technologies 450 Fortune Boulevard Milford, MA 01757 866.9.THERMO (866.984.3766) Fax: 508.634.2199 www.thermo.com Laboratory Pipetting and Consumables info.pipettes@thermo.com Microplate Instrumentation info.microplateinstruments@thermo.com Laboratory Automation & Integration info.labautomation@thermo.com Controlled Environment info.controlenv@thermo.com Molecular Biology info.molbio@thermo.com Sample Preparation info.sampleprep@thermo.com New Labs newlabs@thermo.com Services services.biosciencetech@thermo.com Bioscience Technologies International Sales Office Locations Belgium Brussels +32 2 482 30 30 Fax: +32 2 482 30 31 France Cergy Pontoise Cedex +33 1 34 32 51 51 Fax: +33 1 34 32 51 59 Germany Dreieich +49 6103 408 0 Fax: +49 6103 408 1222 Netherlands Breda +31 76 571 4440 Fax: +31 76 587 9757 Russia Saint-Petersburg +7 812 325 8045 Fax: +7 812 186 1194 Moscow +7 095 755 9045 Fax: +7 095 755 9046 Spain Barcelona +34 93 2233154 Fax: +34 93 2230857 Sweden Stockholm +46 8 742 03 90 Fax: +46 8 742 09 47 Lund +46 46 90 96 60 Fax: +46 46 32 87 70 United Kingdom Basingstoke, Hampshire +44 01256 81782 Fax: +44 01256 81792 China Beijing +8610 5850 3588 Fax: +8610 6621 0847 Shanghai +8621 5465 7588 Fax: +8621 6445 7830 Hong Kong Wanchai +852 2885 4613 Fax: +852 2567 4447 India Bangaalore +91 22 2778 1101 Fax: +91 22 2778 1103 Japan Yokohama-City +81 45 453 9122 Fax: +81 45 453 9222 2001-2003 Thermo Electron Corporation, All rights reserved. Thermo Electron Corporation, CryoCool, SpeedVac, VaporNet, and Analyze, Detect, Measure, Control, are trademarks of Thermo Electron Corporation.