CDF GREEN SHEET. California Department of Forestry and Fire Protection SOUTHERN REGION CA-RSS000077

Similar documents
Preliminary Summary Report of Serious or Near Serious CAL FIRE Injuries, Illnesses and Accidents GREEN SHEET. Firefighter Burn Injury.

GREEN SHEET. California Department of Forestry and Fire Protection

Burned Dozer 230. I m just glad we get to do this the RLS process so others can learn something from it. Dozer Operator

San Ramon Valley Fire Protection District GREEN SHEET

Travis County Emergency Services District #1 Standard Operating Guidelines

STANDARD OPERATING PROCEDURES RESPONDING TO EMERGENCIES DEPARTMENT RESPONSE PROCEDURES EFFECTIVE: AUGUST 2007

National Forests in Mississippi. De Soto Ranger District. Acadian Wildland Fire. Firefighter Burn Incident - May 2, 2011

AMADOR FIRE PROTECTION DISTRICT

San Mateo County Fire Service POLICIES AND STANDARDS MANUAL

3330 N Clayton. C - Side Date: 11/18/2017 Time: 21:48 Incident Number: Address: 3330 N Clayton

Assignment Sheet Apply the NIMS-ICS Model to an Emergency Scene

GREEN SHEET. Los Angeles Fire Department. Informational Summary Report of Serious LAFD Injuries, Illnesses, Accidents and Near-Miss Incidents

Pebble Beach Community Services District Fire Department 3101 Forest Lake Road, Pebble Beach, CA

HOLLY HILL FIRE DEPARTMENT

Truckee Meadows Fire Protection District Guide to Wildfire Terminology

Summary. firefighter training in Since that time the firefighter had attended semi-annual

Unit 9 Objectives. Unit 9 Objectives

2017 Annual Report. King County Fire District No. 27 Fall City, WA

Flint Canyon. September 6, 2012 Wildland Fire Investigation Report. 1 P a g e. Flint Canyon Fire Investigation Report

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Truro Police Department. Fire Emergencies. Policy Number: OPS-9.02 Effective Date: June 1, 2000 REFERENCE:

INCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

REPORT TO COUNCIL. DATE: August 1, 2006 REPORT NO.: FD SUBMITTED BY: Gordon (Shorty) Smith FILE NO.: Fire Chief

The 18 Situations that Shout Watch Out

GLOSSARY OF FIRE PROTECTION TERMS

Richfield Fire. Wildland Fire Accident Investigation Report

Elko County Human Resources Employment Opportunity Announcement

WELCOME TO ROSEVILLE UNIVERSITY

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 5 High Rise On Scene Revised

LA GRANGE FIRE DEPARTMENT OCTOBER 2017

SDG&E PROJECT FIRE PLAN

Cumru Township Fire Department 4/27/10 Standard Operating Guidelines Page: 1 of 6 Section 15.07

OAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN

YTD. The monthly Safety Committee meeting was held on Monday, July 2 nd at GSA Station 35.

Structural Firefighting Policy

WARM WELCOME RISK ASSESSMENTS & HOMESTAY FIRE/GAS SAFETY

2017 Eastside Fire & Rescue Response Coverage Report

Appendix D Fire Safety Requirements

B. Backing Fire - Fire that is moving against the wind or downslope, this fire behavior tends to have a slow rate of spread.

Wildfire in Travis County

FINAL EXERCISE FIRE AND EXPLOSION SCENARIO

STONY HILL RURAL FIRE DEPARTMENT OPERATING GUIDELINES

SPEARFISH FIRE DEPARTMENT POLICIES AND PROCEDURES

Standard Operating Procedure Ottawa Fire Services. Fire Operations- Structural Fire Incidents SUBJECT. Fire Alarm Systems (Silence/Reset) - Revised

Contra Costa County Fire District Station # 69. Battalion 7. November Your station responded to 129 Emergency Calls. Response breakdown

PALM BEACH GARDENS FIRE RESCUE

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Career Fire Fighter Dies While Exiting Residential Basement Fire - New York

EMERGENCY ACTION PLAN GOLDEN CITY CASINO HIGHWAY 162 OROVILLE, CALIFORNIA

Rescues individuals in danger from fire, vehicle accidents, industrial accidents and other situation requiring extraction.

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

Driver Resource Manual Unit 6 Emergency Evacuation

I. It shall be the responsibility of the department officers to implement this operating guideline.

Fire Behavior Case Study

Talking about NFPA History of NFPA NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS

Wilson County Emergency Management Agency 110 Oak Street Lebanon, Tennessee 37087

Services the Agency is Required to Provide Services

LCES: LOOKOUTS, COMMUNICATIONS, ESCAPE ROUTES, SAFETY ZONES

MCCORMICK HIGHWAY FIRE BURNOVER REPORT

INSTRUCTOR GUIDE COURSE: FIREFIGHTER PRE-BASIC SESSION REFERENCE: 1 TOPIC: ORIENTATION AND FIRE BEHAVIOR LEVEL OF INSTRUCTION:

Outline. Standards of Coverage. ICS Features 2/12/2016 ICS

Summary. Introduction

BCGEU JOB DESCRIPTION MINISTRY OF FORESTS

Career Fire Fighter Dies From Injuries Sustained In Fall From Apparatus - Massachusetts

ESCONDIDO FIRE DEPT TRAINING MANUAL Section DRIVER OPERATOR Page 1 of 6 Code Driving Revised

You will be able to carry out the following activities: use firefighting tools in an appropriate and competent manner

AMADOR FIRE PROTECTION DISTRICT

Guemes Island Fire Department

Emergency Planning and Preparedness

Rapid Intervention Team

Fire Department Orientation / Organization

TRAINING AND EDUCATION PAYMENT POLICY FOR TESTING

FIRE RANGER PREAMBLE. Crews specifically trained to attack and extinguish forest fires. Crew and necessary equipment normally transported by truck.

Lamorinda CERT - Unit 2 09/15/2016

READY, SET, GO! A Wildfire Readiness Guide for Property Owners

Banff Mineral Springs Hospital EMERGENCY RESPONSE CODE RED Fire

FIRE PROTECTION & PREVENTION

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

ATTACHMENT A. California Health and Safety Code Section Findings

2013 Compliance Report RCW 52.33

Fire Department Arson Unit. Investigation Report

Roseville Fire Department

Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition

LFR - Code 3 Fire Report

Burn Injury Investigation Report Preparing a Live Fire Prop for Use Miami-Dade County Fire Rescue Department, November 18, 2011

As firefighters dismounted their apparatus, they recognized the life hazard that was presented. WNYF 2 nd issue 1967

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

BROWNSVILLE VOLUNTEER FIRE DEPARTMENT

Technician I Kyle Wilson Line of Duty Death April 16, Marsh Overlook Structure Fire Investigative Report

ENGINEERING STANDARD FOR FIRE STATIONS ORIGINAL EDITION NOV. 1993

Ambulance Operations (Fleet) Procedure Vehicle Evacuation Procedure. National Ambulance Service (NAS)

Appendix J Framework Fire Prevention and Suppression Plan. Prepared by Idaho Power Company 1221 W Idaho Street Boise, ID 83702

SCALES NW EMERGENCY ACTION PLAN

Guidelines for Media at Emergency Incidents

RAMBLER PARK FIRE SAFETY INFORMATION

OXNARD FIRE DEPARTMENT Fire Watch Guidelines

Fire Safety and Utility Controls. CERT Basic Training Unit 2

U.S. Firefighter Disorientation Study Prepared by William R. Mora, Captain San Antonio Fire Department San Antonio, Texas.

Portable Fire Extinguishers

FIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER

Transcription:

CDF GREEN SHEET California Department of Forestry and Fire Protection SOUTHERN REGION CA-RSS000077 San Bernardino Unit Pleasant Valley 2 CA-BDU003587 April 30, 2002 Burn Over CDF Engine 3561 Lookouts Communications Escape Routes Safety Zones A Board of Review has not approved this Summary Report. It is intended as a safety and training tool, an aid to preventing future occurrences, and to inform interested parties. Because it is published on a short timeframe, the information contained herein is subject to revision as further investigation is conducted and additional information is developed.

SUMMARY On April 30, 2002 a vegetation fire occurred at the Pleasant Valley Campground, in Bishop, California. Owens Valley Camp reported the new fire at approximately 1:15 P.M. Engine 3561 responded from Owens Valley Camp, arrived on scene at approximately 1320 hrs and initiated suppression action by attempting to get to the head of the fire. While driving through the green to access the head of the fire, Engine 3561 suffered a rapid air loss to the brake system and became immobile. The fire advanced beyond Engine 3561 on the west and south side of the engine. A sudden change in wind direction and speed caused the fire to advance directly towards the engine at a rapid rate. Despite efforts by the crew from Engine 3561 and units of the Bishop Fire Department, the fire consumed Engine 3561 at approximately 1404 hrs. While attempting to protect Engine 3561, the Fire Captain and two Firefighter 1 s suffered smoke inhalation and were transported to a local hospital. They were treated and put off duty for three days by the treating Physician. CONDITIONS Location: Fuel Type: Terrain: Incident occurred southwest of the intersection of Pleasant Valley Road and Chalk Road, Bishop area. Big Basin Sage, Salt Grass, Red Willow, and Rabbit Brush Rocky, brush covered, uneven Fire Behavior: Moderate to Erratic Weather: From Owens Valley Camp RAWS - 57 degrees F, 8 11% Humidity, 19 MPH Winds, with gust 34 to 54 MPH, variable directions

SEQUENCE OF EVENTS On April 30, 2002, at approximately 1312 hours, an off duty CDF Battalion Chief reports a fire near the intersection of Pleasant Valley Road and Chalk Road. A fire had occurred in this area on the previous day and units were assigned to mop-up and patrol duties. Engine 3561, a 1993 International CDF Model 14 Engine, is dispatched to the new fire at 1315 hours and arrives at 1322 hours. Upon his arrival the Fire Captain on Engine 3561 observes a one acre fire burning along the river with 15 to 20 mph winds. The Fire Captain has the firefighters exit the vehicle and charge the front bumper line of Engine 3561. He then travels through green towards the fire, preparing to mobile attack the fire s edge. Believing there was no active fire to the north of his location, he then turns Engine 3561 to the south mobile attacking the edge of the fire. After traveling over the rocky terrain and heavy brush, the Fire Captain observes he is having difficulty moving forward. The Fire Captain places Engine 3561 into four wheel drive high range, first gear, and reduces pump pressure. This allows the engine to proceed forward and continue applying water to the fire s edge. The Fire Captain and a Firefighter hear an air leak coming from the front area of Engine 3561. The Fire Captain hears the low air warning alarm and visually checks the air gauge. The Fire Captain determines Engine 3561 is immobile due to the loss of air pressure to the braking system, and immediately calls for a mechanic to respond to the scene. [The investigating team determined the cause of the air loss, was the Wet Tank Condensation Drain Petcock had been inadvertently opened when brush became lodged between the battery box and the Air Brake Storage Tank striking the petcock and pushing it to the open position. The open valve combined with the low RPM of the engine and constantly applying the air brakes while mobile pumping caused the Spring Brakes to activate resulting in the immobilization of the Engine. Due to surrounding brush and the fire conditions, this cause could not be found or remedied immediately.] The Fire Captain orders the Firefighters to initiate a hose lay from the bumper line, and instructs them to continue south from Engine 3561 s location, in an attempt to extinguish the fire by a flanking action. At the same time the Fire Captain observes a spot to the northwest of Engine 3561. He then deploys a pre-connected line in an attempt to extinguish the spot fire. Bishop Fire Department Unit R7 arrives at the scene, proceeds to the northwest of Engine 3561, and attempts to extinguish the fire approaching Engine 3561. Engine 3561 and Bishop Fire Department Unit R7 runs out of water as Bishop Fire Department Engine 9 (3800 gallon water tender) arrives on scene with the Bishop Fire Department Assistant Chief. The Fire Captain makes face-

to-face contact with the Bishop Fire Department Assistant Chief and requests Bishop Fire Department Engine 9 support Engine 3561. Bishop Fire Department Engine 9 supplies Bishop Fire Department Unit R7 with water, while applying water to the fire s edge to the north of Engine 3561, with a bumper turret. The Fire Captain observes and reports a 180-degree wind shift from the northerly direction to a southerly direction, the fire south of Engine 3561 changes direction and advances towards the Engine 3561 from the south. The Fire Captain instructs Firefighters to get hand tools and construct hand line around Engine 3561 to protect the engine. Bishop Fire Department Engine 9 attempts to protect Engine 3561, approaching to within 25 feet of Engine 3561 and utilizes the bumper turret in an attempt to apply water. Bishop Fire Department Engine 9 lobs water over Engine 3561 to cool the engine and fire. However, high winds do not allow water to reach Engine 3561. Fire activity increases on the south, west, and north of Engine 3561.The Fire Captain orders the Firefighters to walk to the roadway as a safety zone. At the same time Bishop Fire Department Engine 9 and Engine 7 are forced to back to a safe area. At approximately 1400 hours fire hits Engine 3561 and ignites ordinary combustibles, destroying Engine 3561. The Fire Captain and both Firefighters suffer smoke inhalation in the attempt to save Engine 3561. The Fire Captain and Firefighters were transported to a local hospital for treatment and placed off duty by the treating physician for three days due to smoke inhalation. INJURIES The Fire Captain and both Firefighters suffer smoke inhalation in the attempt to save Engine 3561. The Fire Captain and Firefighters were transported to a local hospital for treatment and placed off duty by the treating physician for three days due to smoke inhalation. DAMAGE Engine 3561 and all contents were destroyed by the fire.

SAFETY ISSUES FOR REVIEW Check all air brake components for wear, leaks, and damage. Pay close attention to the possibility of loose valves on the petcocks utilized on airbrake storage tanks. If valves can easily be turned, replacement is in order. Make sure that when Mobile Pumping, especially in rough terrain, that the transmission is in 1 st gear and the 4WD (if equipped) is in the low range. This will provide maximum power to the wheels. Review LCES Review the 10 Standard Firefighting Orders and the 18 Situations that shout watch out. SUBMITTED BY: Tom Tisdale, Chief Riverside Unit