XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Similar documents
WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

FINNED WATER-TUBE POOL HEATERS

FINNED WATER-TUBE POOL HEATERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

Proudly assembled in U.S.A

Proudly assembled in U.S.A

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

Suggested Specifications Prestige Excellence 110

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Less Than.25% Lead Proudly Assembled in the U.S.A

Less Than.25% Lead Proudly Assembled in the U.S.A

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Less Than.25 Pb Proudly made in the U.S.A

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

97% Thermal Efficiency

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Automatic Circulating Water Heaters

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

Proudly assembled in U.S.A

Models HD101 thru 2342B

Project Name: Location: Engineer: Contractor: I. GENERAL

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Revitalize Building Mechanical Systems (4619)

Hubbell NX500 High Efficiency Gas Condensing Water Heater

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Power Flame Incorporated

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Trinity Lx400 High Efficiency Gas Condensing Boiler & Water Heater

Trinity Lx200 High Efficiency Gas Condensing Boiler & Water Heater

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

TABLE OF CONTENTS BRADFORD WHITE BOILERS

AFUE 95% Heating Input 50,000 to 200,000 Btuh

POWER VTX. Condensing Storage Water Heater. 500 to 1000 MBH 225 Gallon Tank 15-year Warranty. PVI.com ENGINEERED DUPLEX ALLOY

C1050ES Tankless Water Heater

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube boilers for heating hot water.

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

ENGINEERED DUPLEX ALLOY

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

New Versa IC Platform

96.2% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS CON X US REMOTE CONNECT. MODBUS AND BACnet MSTP PROTOCOL

Power Flame Incorporated

SECTION SAMPLE SPECIFICATION FOR BOILER CONTROLLER CONVERSION KIT

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

C1210ES Tankless Water Heater

Date: Project #: Engineer: Prepared By: Bid Date:

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

High Efficiency Commercial Gas Water Heaters

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

FLEXCORE SERIES MASTERSPEC

Boilers Variable Fire Boilers

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

Originators of the Flexible Water Tube design

CAMUS ADVANTUS BOILERS

Boiler & Water Heater

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

RAYPAK ILLUSTRATED PARTS LIST

Triton Series High Efficiency Boiler

940ES Tankless Water Heater

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

Originators of the Flexible Water Tube design

iq1001, Gen II Submittal Data

96% AFUE Efficiency CONDENSING RESIDENTIAL GAS BOILERS CONTROL WITH ADVANCED USER FEATURES MODELS FROM 80,000 TO 285,000 BTU/HR

Bid Date: Date: Project Name: Project #: City/St/ZIP: Fuel Type: Natural Gas Propane. Engineer: Factory Option: Contractor: Key Features.

HCLEARFIRE. High-efficiency, modular steam boiler HP

SECTION HEATING BOILERS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

940ES Tankless Water Heater

CCLEARFIRE CONDENSING FIRETUBE BOILER DESIGNED FOR MAXIMUM HYDRONIC SYSTEM EFFICIENCY 500 TO 3,300 MBTU

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

BURNHAM COMMERCIAL 27 February 2008 MPC Multiple Pass Commercial Boiler Suggested Specifications

KN2/4 SERIES MASTER SPECIFICATION

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

HIGH EFFICIENCY COMMERCIAL BOILERS

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Originators of the Flexible Water Tube design

VCLEARFIRE. High-Efficiency, Commercial Steam Boiler Horsepower

DOM-5. Domestic Hot Water Heaters & Boilers

Transcription:

XTHERM, TYPE WH - MODELS 1005A- 2005A Catalog No.: 3500.801 Effective: 11-15-14 Replaces: NEW PART 1 - GENERAL 1.1 SUMMARY DIVISION 23 34 36.29 COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS A. Section includes condensing, gas-fired copper finned-tube, gas domestic water heaters Specifier Note: Use as needed B. Related Sections 1. Building Services Piping Division 22 10 00 2. Breeching, Chimneys, and Stacks (Venting) Division 23 51 00 3. Electrical Division 23 09 33 1.2 REFERENCES A. ANSI Z21.10.3/CSA 4.3 B. ASME, Sections IV and VIII C. 2006 UMC, Section 1107.6 D. ANSI/ASHRAE 15-1994, Section 8.13.6 E. National Fuel Gas Code, ANSI Z223.1/NFPA 54 F. National Electric Code, ANSI/NFPA 70 G. ASME CSD-1, 2012 (when required) 1.3 SUBMITTALS A. Product data sheet (including dimensions, rated capacities, shipping weights, accessories) B. Wiring diagram C. Warranty information D. Installation and operating instructions 1.4 QUALITY ASSURANCE A. Regulatory Requirements 1. ANSI Z21.10.3/CSA 4.3 2. Local and national air quality regulations for low NOx (0-20 PPM NOx emissions) water heaters B. Certifications 1. CSA ANSI Z21.10.3 / CSA 4.3 2. ASME HLW Stamp and National Board Listed Primary 3. ASME U Stamp and National Board Listed Stainless Steel Condensing 4. CSA Certified < 0.25% Low Lead Compliant 1.5 WARRANTY A. Limited one-year warranty from date of installation B. Limited twenty-five-year thermal shock warranty C. Limited five-year primary heat exchanger warranty (copper), ten-year (Cupro-Nickel) D. Limited ten-year Condensing Heat Exchanger warranty Project Name / Date Division 23 34 36.29-1

PART 2 - PRODUCTS 2.1 MANUFACTURER A. Raypak, Inc. 1. Contact: 2151 Eastman Ave., Oxnard, CA 93030; Telephone: (805) 278-5300; Fax: (800) 872-9725; Web site: www.raypak.com 2. Product: XTherm condensing water-tube domestic water heater(s) 2.2 WATER HEATERS A. General 1. The water heater(s) shall be fired with gas at a rated input of BTU/hr. 2. The water heater shall have a maximum adjustable setpoint of 150ºF. 3. The water heater(s) shall be CSA tested and certified with a minimum thermal efficiency of 97 percent at full fire (99% at part load). 4. The water heater(s) shall be ASME inspected and stamped and National Board registered for 160 PSIG maximum allowable working pressure and 210ºF maximum allowable temperature, complete with a Manufacturer's Data Report. 5. The water heater(s) shall have a floor loading of 131 lbs. /square foot or less. B. Primary Heat Exchanger 1. The primary heat exchanger shall be of a single-bank, vertical multi-pass design and shall completely enclose the combustion chamber for maximum efficiency. The tubes shall be set vertically and shall be rolled into a powder-coated, ASME water heater quality, carbon steel tube sheet. 2. The primary heat exchanger shall be sealed to 160 PSIG rated bronze headers with hightemperature silicone "O" rings. 3. The low water volume primary heat exchanger shall be explosion-proof on the water side and shall carry a twenty-five-year warranty against thermal shock. 4. The headers shall be secured to the tube sheet by stud bolts with flange nuts to permit inspection and maintenance without removal of external piping connections. A heavy gauge stainless steel slotted primary heat exchanger wrap shall ensure proper combustion gas flow across the copper-finned tubes. 5. The water heater(s) flue connection, combustion air opening, gas connection, water connections, condensate drain and electrical connections shall be located on the rear. 6. The primary heat exchanger shall have accessible water heater drain valves with hose bibs to drain the water section of the primary heat exchanger. C. Condensing Heat Exchanger 1. The condensing heat exchanger shall be a single-bank, multi-pass design constructed of stainless steel and shall bear the ASME U stamp. 2. The water heater(s) shall be capable of operating at inlet water temperatures as low as 50 F. D. Condensate Drain 1. The water heater(s) will feature a condensate drain switch which will shut down the water heater(s) if the condensate drain is blocked. E. Burner 1. The combustion chamber shall be of the sealed combustion type employing the Raypak hightemperature radially-fired knitted burner, mounted in a vertical orientation. 2. The burner must be capable of firing at both a complete blue flame with maximum gas and air input as well as firing infrared when gas and air are reduced. The burner must be capable of firing at 100% of rated input when supplied with 4.0 WC of inlet gas pressure, so as to maintain service under heavy demand conditions; no exceptions. 3. The burner shall use a combustion air blower to precisely control the fuel/air mixture for maximum efficiency throughout the entire range of modulation. The combustion air blower shall operate for a pre-purge period before burner ignition and a post-purge period after burner operation to clear the combustion chamber. Project Name / Date Division 23 34 36.29-2

4. The blower shall infinitely vary its output in response to a Pulse Width Modulation (PWM) signal supplied directly from the Versa IC modulating temperature controller, thereby electronically and precisely adjusting the volume of air and gas supplied for combustion. Minimum fire shall be 14% percent of rated input (natural gas or propane gas). F. Ignition System 1. The water heater(s) shall be equipped with a 100 percent safety shutdown. 2. The ignition shall be Hot Surface Ignition type with full flame rectification by remote sensing separate from the ignition source, with a three-try-for-ignition sequence, to ensure consistent operation. 3. The igniter will be located to the side of the heat exchanger to protect the device from condensation during start-up. 4. The ignition control module shall include an LED that indicates fifteen (15) individual diagnostic flash codes. 5. An external viewing port shall be provided, permitting visual observation of burner operation. G. Gas Train 1. The water heater(s) shall have a firing/leak test valve and pressure test valve as required. 2. The water heater(s) shall have dual-seated main gas valve. 3. Gas control trains shall have a redundant safety shut-off feature, main gas regulation, shut-off cock and plugged pressure tapping to meet the requirements of ANSI Z21.10.3/CSA 4.3. H. Water Heater Control 1. The following safety controls shall be provided: a. High limit control with manual reset b. Flow switch, mounted and wired c. PSIG ASME pressure relief valve, piped by the installer to an approved drain d. Temperature and pressure gauge (shipped loose) 2. The water heater(s) shall be equipped with the Versa IC modulating temperature controller with LCD display that incorporates an adjustable energy-saving pump control relay and freeze protection, and is factory mounted and wired to improve system efficiency; three water sensors included (tank sensor is loose) I. Firing Mode: Provide electronic modulating control of the gas input to the water heater. J. Water Heater Diagnostics 1. Provide external LED panel displaying the following water heater status/faults: a. Power on Green b. Call for heat Amber c. Burner firing Blue d. Service Red 2. Provide monitoring of all safeties, internal/external interlocks with fault display by a 3-1/2 in. LCD display: 3. Provide monitoring of all safeties, internal/external interlocks with fault display by a 3-1/2 in. LCD display: a. System status b. Ignition failure c. Condensate blockage d. Blower speed error e. Low 24 VAC f. Manual reset high limit g. Auto reset high limit h. Blocked vent i. Controller alarm j. Flow switch k. Sensor failure l. Factory option m. Inlet sensor (open or short) n. Outlet sensor (open or short) o. System sensor (open or short) Project Name / Date Division 23 34 36.29-3

p. Internal control fault q. ID card fault r. Cascade communications error Specifier Note: The remaining items in this section are options. Delete those that are not being specified.. s. Auto reset high limit (optional) t. Low water cut-off (optional) u. High gas pressure switch (Optional) v. Low gas pressure switch (optional) 4. Provide ignition module indicating the following flash codes by LED signal and displayed on LCD display: a. 1 flash low air pressure b. 2 flashes flame in the combustion chamber w/o CFH c. 3 flashes ignition lock-out (flame failure) d. 4 flashes low hot surface igniter current e. 5 flashes low 24VAC f. 6 flashes vent temperature g. 7 flashes hi-limit h. 8 flashes sensor fault i. 9 flashes low gas pressure j. 10 flashes water pressure k. 11 flashes blower speed fault l. 12 flashes low water cut-off m. 13 flashes hi-temperature ΔT n. 14 flashes Ft-Bus communications o. 15 flashes general safety limit K. Combustion Chamber: The combustion chamber wrapper shall not require insulation to reduce standby radiation losses. L. Cabinet 1. The corrosion-resistant galvanized-steel jackets shall be finished with a baked-on powder coat, which is suitable for outdoor installation, applied prior to assembly for complete coverage, and shall incorporate louvers in the outer panels to divert air past heated surfaces. 2. The water heater(s), if located on a combustible floor, shall not require a separate combustible floor base. 3. The water heater(s) shall connect both the combustion air and flue products through the back of the unit. 4. The heater shall have as standard an internal, combustion air filter rated to MERV 8 (>95% arrestance). M. Water Heater Pump Heater equipped with factory-packaged pump system. N. Cold Water Protection System 1. The water heater(s) shall be configured with an automatic cold water protection proportional bypass system that ensures the heater primary heat exchanger will experience inlet temperatures in excess of 120ºF in less than 7 minutes to avoid damaging condensation. 2. The cold water protection system shall be configured with a variable-flow injection system that is controlled by Versa IC control system that diverts the correct amount of heated outlet water directly into the heater loop to maintain the required minimum inlet temperature. The Versa IC control temperature sensor shall be located in the inlet header of the primary heat exchanger. Specifier Note: The remaining item(s) in this section are options. Delete those that are not being specified. O. PVC Vent Adapter 1. The water heater(s) shall be configured with a PVC vent adapter that allows for the use of PVC vent material when the water heater return water temperature does not exceed 170ºF. The PVC vent adapter shall be factory mounted to the water heater flue outlet and the vent termination adapter shall be shipped loose inside of the water heater crating for field installation. Project Name / Date Division 23 34 36.29-4

2. The PVC vent adapter shall include a flue temperature limit mounted to the water heater flue outlet and interlocked into the water heater safety circuit. 3. The water heater shall also have a 200ºF manual high limit factory mounted into the water heaters outlet header and interlocked into the safety circuit of the water heater. P. Centrotherm Polypropylene Vent Adapter 1. The water heater(s) shall be shipped with a Polypropylene vent adapter that allows for the use of polypropylene vent material when the water heater return water temperature does not exceed 190ºF. The polypropylene vent adapter shall be shipped loose for field installation to the water heater flue outlet. 2. The polypropylene vent adapter shall include a flue temperature limit mounted to the water heater flue outlet and interlocked into the water heater safety circuit. 3. The water heater shall also have a 200ºF manual high limit factory mounted into the water heaters outlet header and interlocked into the safety circuit of the water heater. 2.3 WATER HEATER OPERATING CONTROLS A. The water heater(s) shall feature the Versa IC modulating digital controller, mounted and wired. B. Tank sensor shall be shipped loose for field-installation by installing contractor. Inlet/Outlet sensors are factory-installed. C. Each heater shall have the ability to receive a 0 to 10 VDC signal from the Central Energy Management and Direct Digital Control System (EMCS) to vary the setpoint control or firing rate. Each heater shall have an alarm contact for connection to the central EMCS system. D. Each heater shall be equipped with Modbus communications compatibility with up to 146 points of data available. a. B-85 Gateway BACnet MS/TP, BACnet IP, N2 Metasys or Modbus TCP (optional) b. B-86 Gateway LonWorks (optional) E. Heater(s) shall feature an integrated Versa IC modulating digital controller, mounted and wired. F. The control shall have the ability to provide cascade control of up to 4 heaters as a single system via 2-wire communication. G. System sensor shall be shipped loose for field installation by installing contractor. Inlet/Outlet sensors are factory-installed. 2.4 DIRECT VENT A. The water heater(s) shall meet safety standards for direct vent equipment as noted by the 2006 Uniform Mechanical Code, section 1107.6, and ASHRAE 15-1994, section 8.13.6. 2.5 SOURCE QUALITY CONTROL A. The water heater(s) shall be completely assembled, wired, and fire-tested prior to shipment from the factory. B. The water heater(s) shall be furnished with the sales order, ASME Manufacturer s Data Report(s), inspection sheet, wiring diagram, rating plate and Installation and Operating Manual. PART 3 - EXECUTION 3.1 INSTALLATION A. Must comply with: 1. Local, state, provincial, and national codes, laws, regulations and ordinances 2. National Fuel Gas Code, ANSI Z223.1/NFPA 54 latest edition 3. National Electrical Code, ANSI/NFPA 70 latest edition 4. Canada only: CAN/CSA B149 Installation Code and CSA C22.1 CEC Part I 5. Manufacturer s installation instructions, including required service clearances and venting guidelines B. Manufacturer s representative to verify proper and complete installation. 3.2 START-UP A. Shall be performed by Raypak factory-trained personnel. Project Name / Date Division 23 34 36.29-5

B. Test during operation and adjust if necessary: 1. Safeties 2. Operating Controls 3. Static and full load gas supply pressure 4. Gas manifold and blower air pressure 5. Amp draw of blower 6. Combustion analysis C. Submit copy of start-up report to Architect and Engineer. 3.3 TRAINING A. Provide factory-authorized service representative to train maintenance personnel on procedures and schedules related to start-up, shut-down, troubleshooting, servicing, and preventive maintenance. B. Schedule training at least seven days in advance. END OF SECTION Project Name / Date Division 23 34 36.29-6