FINNED WATER-TUBE POOL HEATERS

Similar documents
FINNED WATER-TUBE POOL HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

WATER-TUBE POOL HEATERS

WATER-TUBE POOL HEATERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION FINNED WATER-TUBE BOILERS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

DIVISION FIRE-TUBE STAINLESS STEEL HEATING BOILERS

Proudly assembled in U.S.A

Proudly assembled in U.S.A

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Proudly assembled in U.S.A

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

ULTRA HIGH EFFICIENCY. Platform with Touch Screen VERSA IC. Up to 99% thermal efficiency! Proudly assembled in the U.S.A.

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

Models 1005A, 1505A, 2005A 2505, 3005, 3505, Touch Screen VERSA IC. Control Platform. Up to 99% thermal efficiency! ULTRA HIGH EFFICIENCY

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Models HD101 thru 2342B

Models 504 thru 2004 Category I with vertical vent. Models 503 thru 2003 Category IV Venting. CSA Certified Lead Content Less Than.

New VERSA IC. Platform. Up to 99% thermal efficiency! Proudly made in the U.S.A

Suggested Specifications Prestige Excellence 110

Less Than.25% Lead Proudly Assembled in the U.S.A

Less Than.25 Pb Proudly made in the U.S.A

Less Than.25% Lead Proudly Assembled in the U.S.A

Models HD101 thru 2342B CSA certified Low Lead Content Less Than -.25% Pb. Proudly made in U.S.A

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

MBTU Models 300A 400A 500A 700A 850A. Can be vented with: VERSA IC. Platform. CSA Certified Low Lead Content Less Than.25% Lead.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

up to 99% MBTU Models 300A 400A 500A 700A 850A Can be vented with: PVC, Centrotherm New Versa IC TM Platform CSA Certified Low Lead Content

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

High Efficiency Commercial Gas Water Heaters

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube water heaters for heating hot water.

97% Thermal Efficiency

SECTION WATER HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

SECTION HEATING BOILERS

Automatic Circulating Water Heaters

C1050ES Tankless Water Heater

TABLE OF CONTENTS BRADFORD WHITE BOILERS

Copper Finned Gas-Fired Volume Water Heaters, Boilers and Commercial Pool Heaters. Low NOx, Quiet, Efficient, Space-Saving

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

RAYPAK ILLUSTRATED PARTS LIST

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

INTRODUCING THE BRADFORD WHITE 24/7 EXPERT SUPPORT CENTER. TABLE OF CONTENTS. Technical Support: Warranty Support:

Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE WARRANTY

Power Flame Incorporated

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Power Flame Incorporated

Triton Series High Efficiency Boiler

Commercial Tankless Rack System

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

RBI MASTERSPEC. A. This Section includes gas-fired, non-condensing finned copper water tube boilers for heating hot water.

Boilers Variable Fire Boilers

up to 99% Efficiency! MBTU Models Can be vented with PVC CSA Verified lead Content Less Than.25% Pb Ultra Low Emissions

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

Commercial Tankless Rack System

Cclearfire HIGH EFFICIENCY, COMPACT CONDENSING BOILER 500-3,300 MBTU

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Boiler & Water Heater

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

Residential/Commercial Gas Condensing Tankless Models

Bosch Greentherm T9800 SE 199 Gas Tankless Water Heater

MULTI-LINK UP TO 20 UNITS COMMON VENT UP TO 8 UNITS COMPLIES WITH LEAD FREE STANDARDS SAFETY FEATURES:

940ES Tankless Water Heater

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

SOLID. STATE. Commercial Tankless. Rack System TANKLESS WALL MOUNT LIGHTWEIGHT EXPANDABLE REDUNDANCY EASY FIELD INSTALLATION EASILY INTEGRATE STORAGE

RAYPAK ILLUSTRATED PARTS LIST

Revitalize Building Mechanical Systems (4619)

SECTION PLUMBING EQUIPMENT

DOM-5. Domestic Hot Water Heaters & Boilers

940ES Tankless Water Heater

C1210ES Tankless Water Heater

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

LOW NOx, HIGH EFFICIENCY, HOT WATER SUPPLY AND HYDRONIC HEATING BOILERS

TURBOPOWER. Non-Condensing Gas, Oil or Combination Gas/Oil Storage Water Heater. 199 to 4000 MBH 150 to 4500 Gallons Tanks 25-year Warranty. PVI.

Commercial Tankless Rack System

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

COMMERCIAL MODELS: XTHERM 1005 THROUGH 2005

Design and Construction Standards SECTION PLUMBING EQUIPMENT

199,000 to 4,000,000 Btu/h 150 to 4500 Gallons Storage

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

MAXIM. Power Combustion Storage Water Heater Gas, Oil or Combination Gas/Oil. 199 to 1200 MBH 125 and 250 Gallon Tanks 15-year Warranty. PVI.

Raypak Residential Products

Commercial Tankless Rack System

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

Air-Fuel Ratio (AFR) Sensor Exhaust & Water Temperature Safety Control Overheat Cut-Off Fuse

HCLEARFIRE. High-efficiency, modular steam boiler HP

FXLF-9. High Efficiency Water Heaters and Boilers

Tankless Condensing High Efficiency Water Heaters

Transcription:

HI DELTA, TYPE P - MODELS 992C-2342C SUGGESTED SPECIFICATIONS Catalog No.: 6000.611 Effective: 10-31-16 Replaces: NEW FINNED WATER-TUBE POOL HEATERS - GENERAL 1.1 SUMMARY A. Section includes gas-fired, Cupro-Nickel finned-tube pool heaters. B. Related Sections Specifier Note: Use as needed 1. Building Services Piping Division 23 21 00 2. Breeching, Chimneys, and Stacks (Venting) Division 23 51 00 3. Electrical Division 23 09 33 1.2 REFERENCES A. ANSI Z21.56/CSA 4.7 B. ASME, BPV Section IV C. 2006 UMC, Section 1107.6 D. ANSI/ASHRAE 15-1994, Section 8.13.6 E. National Fuel Gas Code, ANSI Z 223.1/NFPA 54 F. National Electrical Code, ANSI/NFPA 70 G. ASME CSD-1-2012 (when required) 1.3 SUBMITTALS A. Product data sheet (including dimensions, rated capacities, shipping weights, accessories) B. Wiring diagram C. Warranty information D. Installation and operating instructions 1.4 QUALITY ASSURANCE A. Regulatory Requirements 1. ANSI Z21.56/CSA 4.7 2. Local and national air quality regulations for low NOx (< 20 PPM NOx emissions) pool heaters B. Certifications 1. CSA 2. ASME HLW Stamp and National Board Listed 1.5 HEAT EXCHANGER WARRANTY A. Limited ten-year warranty from date of installation B. Limited twenty-year thermal shock warranty from date of installation - PRODUCTS 2.1 MANUFACTURER A. Raypak, Inc. 1. Contact: 2151 Eastman Ave., Oxnard, CA 93030; Telephone: (805) 278-5300; Fax: (800) 872-9725; Web site: www.raypak.com 2. Product: Hi Delta copper finned-tube pool heater(s) 2.2 POOL HEATERS A. General Project Name / Date 1

1. The pool heater(s) shall be fired with gas at a rated input of BTU/hr. 2. The pool heater(s) shall be CSA tested and certified with a minimum thermal efficiency of 85 percent at full fire. 3. The pool heater(s) shall be ASME inspected and HLW-stamped and National Board registered for 160 PSIG working pressure, complete with a Manufacturer's Data Report. 4. The pool heater(s) shall have a floor loading of 65 lbs. /square foot or less. B. Heat Exchanger 1. The heat exchanger shall be of a single-bank, horizontal-grid design with twelve integral Cupro-Nickel finned tubes, each end of which is rolled into an ASME boiler-quality steel tube sheet. 2. The heat exchanger shall be sealed to 160 PSIG-rated brass headers with high-temperature silicone "O" rings. 3. The low water volume heat exchanger shall be explosion-proof on the water side and shall carry a twenty-year warranty against thermal shock. 4. The headers shall be secured to the tube sheet by stud bolts with flange nuts to permit inspection and maintenance without removal of external piping connections. The heat exchanger shall incorporate "V baffles between the tubes to ensure complete contact of the external tube surfaces with the products of combustion. 5. The pool heater(s) shall be capable of operating at inlet water temperatures as low as 105 F without condensation. 6. The pool heater(s) shall be designed to accommodate field changes of either left or right hand plumbing and electrical while leaving the tube bundle in place. C. Burners 1. The tubular burners shall have multiport radial gas orifices, punched ports and slots, be capable of quiet ignition and extinction without flashback at the orifice, and be manufactured from corrosion-resistant titanium-stabilized stainless steel with low expansion coefficient. 2. The burners will be supplied with a fan-assisted, clean burning, and highly efficient fuel-air mixture. D. Ignition Control System 1. The pool heater(s) shall be equipped with a 100 percent safety shutdown. 2. The ignition shall be Hot Surface Ignition type with full flame rectification by remote sensing separate from the ignition source, with a three-try-for-ignition sequence, to ensure consistent operation. 3. The igniter will be located away from the water inlet to protect the device from condensation during start-up. 4. The ignition control module shall include an LED that indicates fifteen (15) individual diagnostic flash codes and transmits any fault codes to the LCD display. 5. Two external viewing ports shall be provided, permitting visual observation of burner operation. E. Gas Train 1. The pool heater(s) shall have a firing/leak test valve and pressure test valve as required by CSD-1. 2. The pool heater(s) shall have dual-seated main gas valve(s). 3. Gas control trains shall have a redundant safety shut-off feature, main gas regulator, shut-off cock and plugged pressure tapping to meet the requirements of ANSI Z21.56/CSA 4.7. F. Pool Heater Control 1. The following safety controls shall be provided: a. Fixed High limit control with manual reset. b. Flow switch, mounted and wired. c. 125 PSIG ASME pressure relief valve, piped by the installer to an approved drain. d. Temperature and pressure gauge. 2. The pool heater(s) shall be equipped with the Versa IC temperature controller with LCD display that incorporates an adjustable energy-saving pump control relay and freeze protection Project Name / Date 2

and is factory-mounted and wired to improve system efficiency; 4 water sensors included (system sensor and high limit sensor are shipped loose). G. Firing Mode 1. For all models, provide on-off firing control of the gas input to the pool heater. H. Pool Heater Diagnostics 1. Provide external LED panel displaying the following pool heater status/faults: a. Power on Green b. Call for heat Amber c. Burner firing Blue d. Service Red 2. Provide monitoring of all safeties, internal/external interlocks with fault display by a 3-1/2 in. LCD display: a. System status b. Ignition failure c. False flame d. Ignition proving current (HSI) e. Field Interlock f. Air pressure switch g. Low 24VAC h. Manual reset high limit i. Blocked vent j. Controller alarm k. Flow switch fault l. Sensor failure I. Inlet sensor (open or short) II. Outlet sensor (open or short) III. System sensor (open or short) IV. High limit sensor (open or short) m. Internal control fault n. ID card fault o. Cascade communications error Specifier Note: The following items are options. Delete if not being specified. p. Low water cut-off q. Low gas pressure switch r. High gas pressure switch s. Controller alarm t. Cold Water Run 3. A Central Point Wiring board with diagnostic LED s indicating the status of each relay. 4. Provide ignition module indicating the following flash codes by LED signal and displayed on LCD display: a. 1 flash low air pressure b. 2 flashes flame in the combustion chamber w/o CFH c. 3 flashes ignition lock-out (flame failure) d. 4 flashes low hot surface igniter current e. 5 flashes low 24VAC f. 6 flashes Vent temperature fault (not used) g. 7 flashes Hi-limit fault h. 8 flashes Sensor fault i. 9 flashes Low gas pressure fault j. 10 flashes Water pressure fault (not used) k. 11 flashes Blower speed fault (not used) l. 12 flashes Low water cut off m. 13 flashes Hi-temperature delta T n. 14 flashes Ft-bus communication fault o. 15 flashes General safety fault Project Name / Date 3

I. Combustion Chamber: The lightweight, high-temperature, multi-piece, interlocking ceramic fiber combustion chamber liner shall be sealed to reduce standby radiation losses, reducing jacket losses and increasing unit efficiency. J. Venting 1. When routed vertically, the pool heater s flue material and size shall be in accordance with the National Fuel Gas Code, ANSI Z223.1/NFPA54 latest edition (Category I). 2. When routed horizontally, the pool heater s flue material and size shall meet or exceed the requirements as specified for Category III in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 latest edition. 3. The pool heater(s) shall be ducted combustion air ready. K. Cabinet 1. The corrosion-resistant galvanized steel jackets shall be finished with a baked-on epoxy powder coat, which is suitable for outdoor installation, applied prior to assembly for complete coverage, and shall incorporate louvers in the outer panels to divert air past heated surfaces. 2. The pool heater(s), if located on a combustible floor, shall not require a separate combustible floor base. 3. The pool heater(s) shall have the option of venting the flue products either through the top or the back of the unit. 4. Combustion air intake shall be on the left side of the cabinet (standard), right side optional. L. Manual Bypass 1. The heater shall be equipped with an external bronze pump and bypass arrangement designed to maintain the water entering the heater at the proper temperature that will prevent condensation and scale in the heat exchanger. The entire waterway shall be non-ferrous. M. Pool Heater Pump - Refer to Equipment Schedule N. SureRack Pool heater Stacking Kit 1. The pool heaters shall be stacked directly one on top of the other, without offset, to minimize footprint. O. Cold Water Run System 1. The pool heater(s) shall be configured with a cold water run automatic proportional by-pass system that ensures the pool heater will experience inlet temperatures in excess of 105ºF in less than 7 minutes to avoid damaging condensation. The unit can automatically shut down if the inlet temperature is not achieved within the 7-minute time frame. 2. The cold water run system shall be configured with a variable-speed pump that is controlled by the Versa IC software that injects the correct amount of cold water directly into the pool heater loop to maintain a minimum inlet temperature. The factory-installed pool heater inlet temperature sensor shall be utilized for the cold water run system. 3. The control shall have a temperature setting adjustment located in the Setup menu of the Versa IC Control. The inlet temperature range shall be 105 F to 120 F. The PID Logic shall be capable of limiting system overshoot to a maximum of 10 F on initial start-up or call-for-heat. 4. The cold water run system shall be completely wired and mounted at the factory. 5. The control shall have alarm contacts. P. Low Gas Supply Pressure Manifold 1. The pool heater(s) shall be CSA-certified for full-input operation down to 4.0 inches W.C. dynamic inlet natural gas supply pressure. Q. TruSeal Direct Vent 1. The pool heater(s) shall meet safety standards for direct vent equipment as noted by the 2006 UMC, section 1107.6, ASHRAE 15-1994, section 8.13.6, and ANSI Z21.56/CSA 4.7. Project Name / Date 4

2.3 SOURCE QUALITY CONTROL A. The pool heater(s) shall be completely assembled, wired, and fire-tested prior to shipment from the factory. B. The pool heater(s) shall be furnished with the sales order, ASME Manufacturer s Data Report, inspection sheet, wiring diagram, rating plate and Installation and Operating Manual. - EXECUTION 3.1 INSTALLATION A. Must comply with: 1. Local, state, provincial, and national codes, laws, regulations and ordinances 2. National Fuel Gas Code, ANSI Z223.1/NFPA 54 latest edition 3. National Electrical Code, ANSI/NFPA 70 latest edition 4. Standard for Controls and Safety Devices for Automatically Fired Boilers, ANSI/ASME CSD-1, when required 5. Canada only: CAN/CSA B149 Installation Code and CSA C22.1 CEC Part I 6. Manufacturer s installation instructions, including required service clearances and venting guidelines B. Manufacturer s representative to verify proper and complete installation. 3.2 START-UP A. Shall be performed by Raypak factory-trained personnel. B. Test during operation and adjust if necessary: 1. Safeties (2.2 - F) 2. Operating Controls (2.3) 3. Static and full load gas supply pressure 4. Gas manifold and blower air pressure C. Submit copy of start-up report to Architect and Engineer. 3.3 TRAINING A. Provide factory-authorized service representative to train maintenance personnel on procedures and schedules related to start-up, shut-down, troubleshooting, servicing, and preventive maintenance. B. Schedule training at least seven days in advance. END OF SECTION Project Name / Date 5