Hunting the Mighty Milliwatt- The next Technology Step

Similar documents
Hunting the Mighty Milliwatt The next Technology Step

Permanent Infrared Hotspot Detection

PD alarm system brings peace of mind in Malta

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

Tempest Projector Enclosures in Hot and Humid Outdoor Environments

Temperature Control for

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

CLIMATE SEPARATION SOLUTION. SensAir

Rotary Screw Compressors SX Series With the world-renowned SIGMA PROFILE Free air delivery from 0.26 to 0.81 m³/min, Pressure 5.

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Liebert PPC Second Generation Power Distribution Cabinet

Fieldbus Foundation TM Bus diagnostics and troubleshooting

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Products Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

Obstruction Lighting

Rotary Screw Compressors. SM Series With the world-renowned SIGMA PROFILE Flow rate 0.39 to 1.64 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

WHITE PAPER: Thermal Management Solutions

Substation Monitoring System

Rotary Screw Compressors. SK Series With the world-renowned SIGMA PROFILE Flow rate 0.53 to 2.70 m³/min, Pressure 5.5 to 15 bar

Moving to the Cloud: The Potential of Hosted Central Station Services

Real Time Pipeline Leak Detection on Shell s North Western Ethylene Pipeline

Bionics Instrument. Alarm Handling. Gas Alarm Systems

Common Misconceptions Relating to Infrared Inspection Ports

SEL Arc-Flash Solutions

Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

AmpLight group management

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

02/11/2015

Specification for On-Line UPS Battery Monitoring and Data Management System

SECURITY SOLUTIONS Banking and finance

THE ULTIMATE SOLUTION FOR GAS DETECTION SYSTEMS. DRÄGER REGARD

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

APPLICATION DATA SHEET

02/11/2015

Aspir A ation spir P R O D U C T S

The evolution of level switches and detectors

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Frequently asked questions: Intelligent Transmitter Series

SEL Arc-Flash Solutions

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

Surface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes

Appendix A Equipment Used to Monitor Hotels

Phoenix Artificial Lift Downhole Monitoring. Improving artificial lift system performance

SECTION Fluorescent Dissolved Oxygen Measuring System

Advanced Pattern Recognition for Anomaly Detection Chance Kleineke/Michael Santucci Engineering Consultants Group Inc.

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar COMPRESSORS

Vocia VACIE. Reference Guide

Architectural and Engineering Specification for a Real-Time Locating System Flare

CCU Family of Modules

Remote Monitoring of Offshore Structures using Acoustic Emission.

Screw Compressors. HSD Series. Capacities from: 816 to 3044 cfm Pressures from: 80 to 217 psig

Copyright 2017 by Eddy Home Inc. All Rights Reserved.

VACIE REFERENCE GUIDE REVISION 1.2.6

Guide To Troubleshooting INEFFICIENT COOLING FANS

Safety Instrumented Systems

For Complete Fire and Gas Solutions

Removing The Potential For Condensation In An Electronic Cabinet

D1000 Arc-fault Protection System

APPLICATION DATA SHEET

Technologies Hazard management system. Inveron Hazard management system

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

Open Source Home Security System

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Senscient s team has more than 150 years collective experience in gas. detection.

6 th Pipeline Technology Conference 2011

MODBUS MESSAGING to the S5 BATTERY VALIDATION SYSTEM

Updated: September 12, 2018 DIVISION INTEGRATED AUTOMATION. INTEGRATED AUTOMATION Page 1 of INTEGRATED AUTOMATION

WG Buried Cable Perimeter Detection System

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

TraceNet TM TCM2 CONTROL AND MONITORING SYSTEM SPECIFICATION GUIDE

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

I/A Series 716C 1/16 DIN Temperature Controller

LaserFOCUS VLF-250 Engineering Specification

Dry-Running Rotary Screw Compressors

ABSTRACT. KEYWORDS: New Combination, New Product Development, Open Innovation, IoT (Internet of Things), Auto Alert System

IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows

THERMODYNAMICS STEAM P7690 AND STEAM BENCHES CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

Q1. Carefully read the following extract from a safety leaflet. Then answer the questions.

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

CT EN rel. 10/09 Copyright Eliwell Controls s.r.l All rights reserved

Leak Detection - Application Note

The Evolution of Cleaning Methods in the PCB Reworking Process

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

Consultant Specification AGILE Wireless Fire Detection System

Coal Pile Fire Monitoring System

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Model D12-IR. Digital Gas Transmitter...

Complete Boiler Management in a Compact, Affordable System

Temperature Monitoring in Low-Voltage Switchgear

TRACENET TM TCM18 CONTROL AND MONITORING SYSTEM

ZADE/Room Management System

TRIDENT GS SERIES Central Chiller

Predictive Maintenance for Fire Sprinkler Systems. Jeffrey D. Gentry Sonic Inspection Corporation

Arc Fault Protection System D1000

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Transcription:

Dr Francesco Pompi PhD, President Exergen Corp Ross Kennedy, C.E.O, QHi Group Ltd Bad joints and connections are the most common cause of failure in electrical equipment yet they can not be detected by conventional metering or load measurement Presented for 7 x 24 Exchange National Conference Orlando Florida June 2006 Abstract : Milliwatts can turn into Mighty Milliwatts (MMW), when resistance increases, typically in loose or bad connections. These MMW, if not detected and allowed to develop can become Megawatts of energy causing catastrophic failure. The exponential growth from milliwatt to megawatt is completed in seconds, but the milliwatt energy signature prior to this situation is typically at too low a level to be detected by conventional metering / lcurrent measurement. The only way to detect these elusive MMW is via the thermal increase at the joint / connection, which can be detected utilising non contact infrared sensors of sufficient sensitivity & reliability. Periodic thermal imaging inspections once or twice per year rely heavily on luck and variable site specific conditions. Expensive intervention (shutdown) maintenance every 1 > 3 years is thus still required. For high downtime cost organisations (i.e. Datacentres), new infrared technology now enables continuous 24/7 thermal monitoring of mission critical equipment INSIDE the panels to be cost effectively achieved. The developed system can also be fully integrated into existing BMS/SCADA systems, web enabled, provide on-line real time data that have high downtime costs. Examples include financial services, telecommunications, data centres, large scale manufacturing, utilities, media, shipping and urban transportation systems. Throughout all these diverse industries the common denominator is POWER. So what is the Mighty Milliwatt and how relevant is it to the circumstances described above? Small amounts of resistive energy losses, converted to heat from electrical circuit elements in high power electrical systems, usually at connections, are manifested as a temperature rise above ambient. 0.001Watt in resistive energy lost by circuits using kilowatts to megawatts of power represent less than 0.0001 of the energy transmitted Bad joints and connections are the most common cause of failure in electrical equipment yet they can not be detected by conventional metering or load measurement. The best detection method is thermal measurement and non contact infrared technology has become the universally accepted method for detecting such faults. Such detection is of particular importance to organisations

Let s calculate it: 1 o Warmer than ambient KW s =1 in 2 Area KW s q=hr x A x (T - TA) = 1 x 1 x 1 =.007 Btu/hr Ft2 144 Convert to Watts.007 3.4 =.002 Watts = 2 Milliwatts Figure 1 shows the level of milliwatts created from a connection 1inch square in area and 1 degree F warmer than ambient. As can be seen it is just 2 milliwatts. Milliwatts are created as the resistance from a lose connection increases. Figure 2 shows the example for a 100 amp cable. P = I2 x R = Heat Dissipated as MMW Calculate R for 2MMW (1 F Rise) For 100 Amp Cable P =.002 = I 2 R = (100) 2 R R =.002 =.002 =.0000002 Ω (100)2 10,000

Undetectable via meter However the Mighty Milliwatt is well named. When Current is increased and Resistance increases i.e. if the connection were to loosen with time/oxidation and the resistance increased to 1 Ω then For 100 Amp Circuit Power = I 2 R = (100) 2 (1) = 10,000 w =10kw The Mighty Milliwatt has turned into ten kilowatts - enough energy to melt 1 ounce of copper in 0.6 seconds and for the organisation involved - catastrophic failure. When the resistive loss exceeds a threshold value temperature increase causes rapid and irreversible increase in resistance triggering positive feedback that will escalate to exponential level. megawatts kilowatts watts milliwatts Normal Milliwatts > Mighty milliwatts > Megawatts = catastrophic Failure

The resistive energy is lost approximately 50% via radiation and 50% via convection to the local environment. However the radiation component is detectable via infrared radiation methods of sufficient sensitivity and reliability as a temperature rise above ambient. Temperature rise is very sensitive to load, when load changes by factor of 3, T changes by factor of 10. Thus for high downtime cost organisations continuous thermal monitoring would certainly provide a significant increase in risk mitigation of power failure. Further, with available trend data, intervention maintenance cycles can be extended with confidence, generating significant downtime savings. If we were starting with a blank sheet of paper the requirements for continuous thermal monitoring could be summarised as: 1 Small reliable infrared (non contact sensors) continuously measuring temperature rises above ambient, capable of placement INSIDE the enclo sure. 2 Variable F.O.V./distance from target 3 Negligible metallic cross section (non conductive) 4 Self powered 5 Local signal conditioning outside electrical panels 6 Wired or wireless data transmission to monitoring computer 7 Appropriate software/integration capability We have thus determined that these Mighty Milliwatts represent the initial stages of a situation, which if left to develop, can cause catastrophic failure, & can only be detected using continuous infrared (non contact) thermal measurement, (periodic inspection may detect the problem but is reliant on luck, and a number of site specific variables). Let us thus look at how this next technology step has evolved. Technology step number 1 Involved non switch off periodic inspection utilising an engineers hand to gauge the temperature on the panel and determining if it was abnormal. Whilst often effective, this is clearly an unacceptable technology for mission critical equipment in today s high downtime cost environment.

Technology step number 2 Was the introduction of periodic infrared thermal imaging technology, enabling no switch off inspections to be carried out on a more objective basis and whilst still dependent on operator skill/experience represented a significant step forward. However this still did not resolve certain key issues. It was still periodic; representing 1 or 2 days out of 365, and thereby remained reliant on quite a significant degree of luck, ( 1 > 2 days out of 365), since it requires the problem to have developed to a point it is detectable, but not to the point of failure. A further problem was that the inspection was conducted outside the enclosure, measuring the exterior surface of the panel, rather than the actual equipment inside the panel. Consequently, it requires correlation between external & internal component temperatures, that can vary significantly, according to climatic and equipment variances. Technology step number 3 Was the introduction of thermal windows. These can either be mesh/screen or crystal. Whilst this significantly improved infrared transmission, mesh dissipates heat think of the principle of a fire guard. Thus, whilst improving the IR typically indicate the area of a problem rather than the location. Specific transmission of that of a solid metal panel it would. Crystal windows vary, but typically cut transmission by approximately 30-70%. The trade off is that the better the crystal transmission the more delicate the material. However both need direct line of site to the target, can add significant cost, and still remain periodic rather than continuous.

Thus the conclusion is that whilst periodic thermal imaging was a huge step forward, allowing more objective, recordable, non switch off inspection, and thermal windows provided a further technology step, improving inspection accuracy, both remain preventative i.e. time based inspection, rather than predictive i.e. continuous monitoring, utilising trend analysis and alarms to predict failure before the event. inspections once or even twice per year. Clearly, risk mitigation could be significantly reduced via the use of continuous thermal monitoring on mission critical electrical equipment.. So is continuous monitoring really required. If we look at the lengths to which high downtime cost organisations go to in an effort to avoid power failures we can see that other measures include: 1 Over specification based on design load (often 50% plus) 2 Dual redundancy 3 UPS often more than one 4 And in addition to all these measures significant sums are spent on fire detection/suppression. Even with all these safe guards in place, it is normal for such organisations to still carry out periodic thermal Technology step number 4 Was the introduction of the infrared thermocouple (IRt/c ). Perhaps the most important feature of this unique device is the fact that it is self powered. All other IR devices require power to the sensor. Because the signal level is so small (microvolts) IR devices require an amplifier to avoid the small signal level being swamped by the power The amplifier introduces the possibility of electronic drift and thus calibration will have to be checked on a regular basis. This would be of particular significance to organisations with ISO quality standard systems. The IRt/c is self powered (just like a standard thermocouple) and thus requires no amplifier and thus lifetime repeatable calibration. The IRt/c sensors are small, plastic, low cost, ultra reliable, non contact devices, which measure the rise above ambient, and have recently gained UL certification. There has also been the recent introduction of specifically designed small plastic cable sensors, also measuring rise above ambient. These can be used where there are cable joints as apposed to copper bus bar, and thus non contact is not a requirement. The increase in temperature, resulting from the increased resistance from the bad connection is conducted down the cable to the sensor which is normally located within a few inches of the connection. Data Acquisition cards (DAC s), have been developed which both linearise and condition the signal of these unique sensors, making them suitable for noisy electrical environments. These DAC s can accept 8 mixed (IRt/c cable) inputs and are din rail mounted either in existing spare enclosures within a panel or externally in their own enclosure. This avoids bulky cable looms within the panel, and providing a secondary benefit for clear accurate cable marking. The DAC s per panel are linked via 485 data cable, (typically using a good quality shielded CAT 5 cable). There are then a number of options regarding/software/integration.

Option 1 Interlink all data cards on system and connect back to host computer utilising proprietary software. Option 2 As option 1 with addition of alarm relay to existing BMS + - T T T S mv Option 3 Introduce protocol conversion hardware prior to host computer thus enabling the system to be integrated with over 400 existing BMS/Scada systems Option 4 Utilise data acquisition card capability to provide output protocol in Modbus Profibus, BACnet, Devicenet, Ethernet to enable direct connection per panel to existing host system bus cable and subsequent full integration into host system. Rs Vs + R3 R2 RT V+ R1 C1 V- Self Powered IRt/c Circuit Diagram

This continuous thermal monitoring technology can be designed into new installations or retro fitted to existing installations at next suitable shut down. Where total shut downs are not possible (i.e. data centres/large scale manufacturing) the system can be fitted on a partial and progressive basis. In choosing what to monitor perhaps the first question to be asked is what is periodically thermally imaged. That would form the basis of what should be continuously monitored. In essence it would be critical joints and connections on the mission critical element of the electrical equipment. The key word is critical. There are some secondary benefits which derive from continuous monitoring 3 Where removal of panels for live imaging is carried out a major risk mitigation in personnel safety is achieved 4 The cost of the installed monitoring as a percent age of job cost is typically 1-2%, which can be amortised over the life of the equipment. This new infrared technology has provided the next technology step enabling continuous 24/7 thermal monitoring of mission critical equipment to be carried out inside the enclosures enabling the prediction of failures before they happen.. 1 Can potentially provide circa 20% extra life on major capital assets on basis of trend data 2 Extend conventional intervention maintenance by circa 2 to 3 years, thus achieving downtime savings which make the thermal monitoring self financing within a short time frame. Why take a SNAPSHOT when you can have the WHOLE PICTURE