Physics Requirements for the CXI Detector Stage

Similar documents
Doc. No. SP R0. CXI Detector stage. Prepared by: Signature Date Jean-Charles Castagna Design Engineer

Doc. No. SP R0. CXI Reference Laser. Prepared by: Jean-Charles Castagna Signature Date Design Engineer

Change History Log. Rev Revision Sections Affected Description of Change /22/08 All Initial Version

Montanez, Boutet, Fox, Van Campen, Hays, Woods

LCLS Instruments. Jerry Hastings June 20, 2008 LCLS

FEE Diagnostics and Commissioning. June 17, 2008

Customized MCPs for Analytical Instruments. An MCP for every application

A CONCEPT FOR CANCELLING THE LEAKAGE FIELD INSIDE THE STORED BEAM CHAMBER OF A SEPTUM MAGNET*

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

LHCb Rich Detectors Control and High Voltage Systems

CXI Detector Status, Cost & Schedule

Diamond Windows & MCP Detectors for Synchrotron Applications

Optical Time Domain Reflectometry (OTDR)

XEUS mirror calibration:

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

Bunch Length Interferometer System

WHAT IS LASER ULTRASONIC TESTING?

Eurys Series. User Guide. Broadband Faraday Rotators & Optical Isolators Small Aperture (5mm)

LASER SAFETY BARRIER

ISIS Design Division Electrical Engineering. S Birch. September 2012.

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Analisi del Focus-shift su sorgenti multikw. Luca Porcelluzzi Ophir Spiricon Europe GmbH

Table of Contents. Check the LCLS Project website to verify 2 of 12 that this is the correct version prior to use.

in mobility Gentle & precise cleaning of sensitive Very quiet air-cooled system Large operating distance (up to 250 mm) Laser class 4 product

HART XL High Sensitivity Smoke Detection

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Rutgers Environmental Health and Safety (REHS)

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

ISO INTERNATIONAL STANDARD. Coating powders Part 13: Particle size analysis by laser diffraction

CO 2 Laser. High Reliability and Performance

Laser Standard Operating Procedure

Micromegas detectors for the upgrade of the ATLAS Muon Spectrometer

Status of the PRad Experiment (E )

Pyramid Engineering Services Co Ltd. Integrated Laser Systems

Perimeter security using Fibre optics

2008 JINST 3 S The CMS experiment at the CERN LHC THE CERN LARGE HADRON COLLIDER: ACCELERATOR AND EXPERIMENTS.

LASER SAFETY. Class 2 and 2a - low power, low risk Class 2 and 2a lasers have low power and emit visible light. They will cause harm if viewed

W. W. Hansen Experimental Physics Laboratory STANFORD UNIVERSITY STANFORD, CALIFORNIA Gravity Probe B Relativity Mission

Measuring Couch Motion Accuracy with X-ray Beam Fluence

MD456: Monitoring of abort gap population with diamond particle detectors at the BGI in IP 4

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

3kW 6kW, QUBE Fiber Lasers

state of the art methane leak detection CHARM and GasCam 2011 October 13 th Dr. Axel Scherello

BGA Rework Station Pro-660

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

Laser Safety and Regulations Division of Physics and Applied Physics, School of Physical and Mathematical Sciences Nanyang Technological University

Hands-On Laser Beam Path Alignment Practical. Environment, Safety, Health & Quality Office SERF E141 Last updated: 12/28/2017

OptoYag M. clear vision

Vacuum requirements and Beamline interface at the VUV-FEL User Facility

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Radiation Safety issues for the PF-AR in KEK

DUQUESNE UNIVERSITY. Laser Safety Program

TIMS TIMS. Thermal Ionisation Mass Spectrometry.

Bonn testbeam, QUAD development

Goals Understand Responsibilities, Awareness, Communication. Beamline phases Design, Implementation, Commissioning, Operation

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

West Virginia University Laser Safety Program

Status of the Advanced Virgo detector

APPLIED. OMA-406R Rackmount Process Analyzer

ESTB Proposal from the Stony Brook University: Test of a RICH-Prototype Based on CsI-GEMs

Contact Information. Procedure Title. Procedure Author

AIDA Advanced European Infrastructures for Detectors at Accelerators. Presentation. LumiCal alignment system, status report

ML1 MULTI-LINE LASER INSTRUCTION MANUAL

Modular: available in any length Current monitoring & error detection Wavelengths: from UV to Visible and IR. LOTUS Line lights

HART XL High Sensitivity Smoke Detection

The Laser System Supervisor (LSS) is John Hansknecht. Extension: 7096

Mass Sensors, Inc. Profile. Applications. Technology Baur Blvd, St. Louis, MO (314)

S ATION EWORK ST BGA R

Leica EM ACE600 Carbon & Iridium Coating System

Identify the key elements of the laser source, regardless of the type of measurement or sensor required;

Variable Temperature Microprobe Systems

Product data sheet Palas Fidas 200 S

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Experimental Particle Physics PHYS6011 Joel Goldstein, RAL

metro B6012 VIBRATIONS SIMPLIFIED... Product brochure Easiest portable vibration analyzer and balancer TECHNOLOGIES PVT. LTD.

End To End Optical Beam Smoke Detector. Additional Information

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Praetorian Fibre Optic Sensing

Covidien Articulating Absorba Tack Foil Pouch Leak Tester Owner s Manual IPE SN Rev 1

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

OPERATING AND MAINTENANCE MANUAL

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

4.8 FARADAY CUP ASSEMBLY OPTION

Approved by Principal Investigator: Date: Approved by Laser Safety Officer: Date:

First results and developments of the multi-cell SDD for Elettra and SESAME XAFS beam lines

Texas active target (TexAT) detector part 1: Design and construction progress

ND280 Construction Status Report

Safety Photo Beam UL MONITORED DEVICE

Smart Fiber Lasers for Micro Machining Applications

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

CLEAN-LASERSYSTEME GMBH

Custom Products Gallery

Cemar Electro Inc. MAXX-606/607 Patient Positioning Laser. Installation and Set-up Manual

Hemi Anechoic Chamber Number:

WASTEWATER Online UV%Transmission Analyzer

SYNRAD Technical Bulletin # 0015d

Transcription:

PHYSICS REQUIREMENT DOCUMENT (PRD) Doc. No. SP-391-000-28 R0 LUSI SUB-SYSTEM CXI Physics Requirements for the Sébastien Boutet CXI Scientist, Author Signature Date Paul Montanez CXI System Engineer Signature Date Jean-Charles Castagna LUSI/LCLS Engineer Signature Date Signature Date Darren Marsh LCLS Quality Assurance Manager Signature Date Nadine Kurita LUSI Chief Engineer Signature Date Tom Fornek LUSI System Manager Signature Date Revision Date Description of Changes Approved R0 23JUN08 Initial release Verify that this is the latest revision. 1 of 5 Check for change orders or requests

Table of Contents Table of Contents...2 1. Overview...2 2. Applicable Documents...2 3. Performance Requirements...2 4. Size Requirement...3 5. Positioning Requirements...3 6. Vacuum Requirements...5 7. Controls Requirements...5 1. Overview The 2D X-ray Detector used by the CXI instrument is described in document LCLS PRD # 1.6-002, Physics Requirements for the 2-D X-Ray Detector. The detector is required to be accurately placed so that the incident X-ray beam passes through the hole in the middle of the detector at various distances from the sample. The detector will be mounted in vacuum. The detector stage comprises the vacuum enclosure in which the detector is placed, the supports and motions of this vacuum enclosure, the cabling and cooling lines going to the detector and the in-vacuum mount and motion stages that hold the detector. This document describes the requirements of the detector stage system. The coordinate system is defined in Mechanical Design Standards Supplement DS-391-000-36. 2. Applicable Documents PRD# SP-391-000-03 LUSI Controls and Data System PRD# SP-391-000-06 LUSI Data Management System PRD# SP-391-000-19 CXI Instrument PRD# SP-391-000-21 CXI Reference Laser System PRD# SP-391-000-24 CXI 0.1 micron KB System PRD# SP-391-000-25 CXI 1 micron KB System PRD# SP-391-000-30 CXI Ion TOF PRD# SP-391-000-63 CXI Precision Instrument Stand LCLS PRD # 1.6-002 2-D X-Ray Detector 3. Performance Requirements 3.1. It shall be possible to set the detector distance from the interaction region to values between 50 and 2600 mm. 3.2. It shall be possible to continuously and remotely vary the detector distance from the interaction region over a range of at least 600 mm. 3.3. It shall be a design goal to make it possible to mount the detector stage downstream and upstream of the sample chamber. The 0.1 micron KB system (PRD SP-391-000-24) shall be 2 of 5

removed to allow the detector stage to be mounted in the upstream position, if the 0.1 micron KB system is located in a chamber separate from the sample chamber. If the engineering solution is to have the 0.1 micron KB system located inside a larger sample chamber, then this requirement no longer applies. 3.4. A retractable visible light photodiode shall be included behind the X-ray 2D detector to align the detector hole on the CXI Reference Laser beam (PRD SP-391-000-21). This center of the photodiode shall be positioned to within 0.5 mm from the laser beam center. This can be achieved manually. 3.5. The photodiode shall be capable of measuring the intensity of the continuous laser light at a rate of 5 Hz. 3.6. A retractable screen shall be included behind the X-ray 2D detector to align the detector hole on the CXI Reference Laser beam (PRD SP-391-000-21). This screen shall allow visual inspection of the reference laser profile after it passes through the X-ray 2D detector. This visual inspection shall be performed with the x-ray beam turned off and the observer shall be standing inside the hutch. The retractable system may be manual. 4. Size Requirement The detector will be provided to the CXI instrument housed in a 10 diameter cylinder that is 5 deep. This is a maximum envelope which will drive many of the design decisions. 4.1. The vacuum enclosure of the detector shall be large enough to enclose the detector, its mount, the in-vacuum cooling lines, the in-vacuum cables and the in-vacuum stages used to move it. 4.2. The flange of the vacuum spool attached to the sample chamber shall be large enough to allow the detector to protrude into the sample chamber. 5. Positioning Requirements Two focusing optics will be used for the CXI instrument and they will each have a different focal spot location in the xy interaction plane. Furthermore, the unfocused beam will also be located at a third point in the x-y plane. The KB1 and KB0.1 systems (PRD SP-391-000-24, Physics Requirements for the CXI 1 micron KB System and PRD SP-391-000-25, Physics Requirements for the CXI 0.1 micron KB System) will deflect the beam in the horizontal plane by 6.8 to 12 mrad. This exact angle is still to be determined. While the deflection angle will be the same for both KB systems, the upstream location of the KB1 system causes a large displacement in the x direction at the detector location. The following requirements are designed to account for these beam displacements to be able to align the detector on any of the 3 beam directions. Some of these requirements can be accommodated by the CXI Precision Instrument Stand (PRD SP-391-000-69) on which the detector stage shall be mounted. 3 of 5

5.1. The CXI Precision Instrument Stand (PRD SP-391-000-63) shall be used to support the CXI Detector Stage. 5.2. The rough alignment of the pitch and yaw angle of the detector stage to the LCLS beam direction which depend on the focusing optics used shall be accomplished using the CXI Precision Instrument Stand (PRD SP-391-000-69). 5.3. The detector stage shall translate in the x and y directions to allow centering of the LCLS beam to within 50 µm of the center of the hole in the detector for any of the focusing optics (KB0.1, KB1 and unfocused beam). 5.4. The detector stage shall move the detector in the z direction within the range described in requirements 3.1 and 3.2 with a repeatability of 50 µm. 5.5. The detector stage shall allow fine alignment of the pitch and yaw angle of the z stage to the LCLS to within a repeatability of 0.5 mrad. 5.6. The detector stage shall have the motorized motions listed in Table 5-1. The stability requirement listed means over a period of a few days. 5.7. The in-vacuum translation range along the z-axis shall not be required to be continuous. A minimum continuous range shall be at least 600 mm. 5.8. Spacer vacuum spools shall be used to span the space between the sample chamber and the detector stage when the detector stage is not attached directly to the sample chamber. 5.9. The surface normal of the detector sensing area shall be parallel with direction of travel of the z stage to within ±2. Motion Nominal Position Range Resolution Repeatability Stability x 0-5 mm < x < 5 mm 10 µm 10 µm 1 µm y 0-5 mm < y < 5 mm 10 µm 10 µm 1 µm z 50 mm 50 < z < 2600 mm 50 µm 50 µm 1 µm Pitch 0 mrad -20 mrad < z < 20 mrad 100 µrad 100 µrad 10 µrad Yaw 0 mrad -20 mrad < z < 20 mrad 100 µrad 100 µrad 10 µrad Table 5-1: Motion requirements for the detector stage. 4 of 5

6. Vacuum Requirements 6.1. The detector shall be mounted in a 10-7 Torr pressure environment or better and the appropriate vacuum practice for the design, manufacturing, and installation of the system components shall be implemented. 6.2. It shall be possible to isolate the vacuum of the detector stage from the vacuum of the sample chamber and the vacuum of everything downstream of the detector stage. 6.3. A port for visual inspection of the detector shall be provided. This port shall allow viewing of the front face of the detector at an angle as close to normal as possible. 6.4. The feedthrough(s) for the detector signals and power shall be located near the downstream end of the vacuum enclosure. 6.5. There shall be a feedthrough flange near the downstream end of the tube for cooling lines. 6.6. There shall be no water to vacuum joints that could lead to a water leak directly into vacuum. 6.7. The 2D X-ray detector housing will have an open back end. The pumping on the vacuum enclosure of the detector stage shall be designed to make any outgasing from the detector flow away from the interaction region. 6.8. The downstream end of the vacuum enclosure of the detector shall allow more vacuum sections to be attached to let the beam propagate further to diagnostics devices. 7. Controls Requirements The controls and data acquisition associated with the detector stage shall be consistent with the requirements outlined in the documents PRD SP-391-000-03, Physics Requirements for the LUSI Controls and Data System and PRD SP-391-000-06, Physics Requirements for the LUSI Data Management. Requirements specific to the detector stage are described below. 7.1. Remote operation of all the positioners shall be implemented via the instrument control system. 7.2. Password protection shall be implemented for all the positioners of the detector stage to protect the detector from damage due to the LCLS beam in the event of an accidental move. 7.3. Interlocks shall be implemented to prevent the gate valve separating the sample chamber from the detector vacuum spool from closing while the detector is protruding through the valve. 7.4. Vacuum interlocks shall prevent the valves upstream and downstream of the detector stage from opening while the pressure is above 10-5 Torr. 7.5. The position of every positioner shall be recorded on every pulse for which experimental data is measured and these positions shall be embedded in the experimental metadata. 7.6. Limit (software or hardware) shall be used to prevent the detector from colliding with the walls of the vacuum enclosure and the components inside the sample chamber. 5 of 5