Introducing the Digital Illumination Interface Alliance

Similar documents
DALI-2: New Standards and Mandatory Certification

Experience the future of lighting with SR

Scanlight Next generation dimmable addressable lighting control

2015 /9C EN-00 OSRAM GmbH Marcel-Breuer-Str München Germany. LED module PL-LIN-HV-DC-G1. M see attached list

Your partner for intelligent street light systems

Empowering Your Vision

Overview of International Lighting Standards Steve Coyne Director, Light Naturally UNEP Consultant

This is a preview - click here to buy the full publication

2017 Commercial & Industrial Program C&I Lighting Prescriptive Rebate Application

C-Bus Application Note. Function Rooms and Ballrooms. Overview

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

Connected lighting components. Xitanium SR drivers EasyAir office sensors. Connected lighting components

QTi DALI 1X58 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T8 ECG dimmable DALI for FL 26 mm

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

TruVision Navigator. Centralised video, access control and network management

QTi DALI 1X35/49/80 DIM

Connections, displays and operating elements C D E G H. Installing the control unit

Connectivity Control Confidence

QTi DALI 2X21/39 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

PRODUCT DATASHEET QTi DALI 4X14/24 DIM

Compliance with Lighting Standards and Management Systems (ANSI C137)

BACnet and Lighting Applications

Controlling LEDs to meet. Russ MacAdam Director of Engineering Development

QTi DALI 4X14/24 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

Protect your investment with Safety Manager

Waters 2795 Separations Module

INTERNATIONAL STANDARD

QTi DALI 1X28/54 DIM. Product datasheet. QUICKTRONIC INTELLIGENT DALI DIM T5 ECG dimmable DALI for FL 16 mm

FINAL DRAFT INTERNATIONAL STANDARD

Smarter Field Instrumentation Life Cycle Management. Ray Rogowski Global Marketing PMC Instruments

Australian Standard. Functional safety Safety instrumented systems for the process industry sector

INTERNATIONAL STANDARD

AS/NZS IEC 62560:2014

Australian Standard. Smoke alarms. AS (Incorporating Amendment Nos 1, 2, 3 and 4) AS 3786

2015 Honeywell Users Group Europe, Middle East and Africa

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

Power over Ethernet cable Product standards and Installation code Updates. Julian Mereuta - June 1, 2017 Banff, Alberta

DEPARTMENT OF TRADE AND INDUSTRY DEPARTEMENT VAN HANDEL EN NYWERHEID. NATIONAL REGULATOR FOR COMPULSORY SPECIFICATIONS ACT (Act 5 of 2008)

Lighting of the future

C-Bus Four Channel General Input Unit Installation Instructions

SOUTH AFRICAN NATIONAL STANDARD

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

Fulham s Lighting Controls (LCS) Manage 7 Integrated Lighting Control Strategies

AIR CONDITIONERS MINIMUM ENERGY PERFORMANCE, LABELLING AND TESTING REQUIREMENTS FOR LOW CAPACITY WINDOW TYPE AND SINGLE-SPLIT

This is a preview - click here to buy the full publication ICS ISBN

Different types of Fire Alarm System

Draft for Comment Please comments to Part A(i)

Architectural and Engineering Specification for a Fence-Mounted Perimeter Intrusion Detection System. FlexZone

ArtLED Gallery and Museum Spotlights

This document is a preview generated by EVS

Protect your Investment with Safety Manager R160 and Integrated Fire and Solutions

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

Intelligent LIGHTING. A team of smart people to bring smart solutions to your lighting needs

C-Bus Four Channel Analogue Output Unit Installation Instructions

Australian Standard. Fire detection, warning, control and intercom systems System design, installation and commissioning

TECHNICAL SPECIFICATION

ENERGY STAR Approaching Smart Grid: Home Appliances Amanda Stevens, U.S. EPA

Oracle Communications Performance Intelligence Center

OpenDevice Events Guide

Advanced Diagnostics for HART Protocol Rosemount 3051S Scalable Pressure, Flow, and Level Solutions

High-Mast Lighting A Powerful, New Combination to Save Energy & Reduce Operating Costs

Lighting Controls solutions for offices

IEC Functional Safety Assessment

User s Manual. YTA110, YTA310, YTA320, and YTA710 Temperature Transmitters. Manual Change No

Operation Manual Model: Light Switch Combo Universal Dimmer Module Item No.: WMR-252. Specification. Wiring

Instructions PRODUCT RANGE NEWLEC DALI OCCUPANCY DETECTOR PART NUMBER NL5701DALI

Design and Commissioning of Lighting Control Systems. Rick Miller, PE, LC, LEED AP RNM Engineering, Inc. October 18, 2012

Alarm Lock A Division of the Napco Security Group 333 Bayview Avenue Amityville, New York Phone (631) Fax (631)

2019 Price List. Company Overview. Gateways. Super Gateways. paragonrobotics.com GW3 GW10

2018 Business Lighting Rebate Application

Australian Standard. Functional safety of electrical/electronic/programmable electronic safety-related systems. Part 0: Functional safety and AS 61508

Certification Report of the ST 3000 Pressure Transmitter with HART 6

Certification Report of the ST3000 Pressure Transmitter

For Android devices MYQ-G0301 MYQ-G0301C MYQ-G0301D MYQ-G0301LA

design on demand

LIGHTING CONTROLS

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

Practical Distributed Control Systems (DCS) for Engineers & Technicians. Contents

Architectural and Engineering Specification for a Hybrid Perimeter Intrusion Detection and Intelligent Lighting System.

INTERNATIONAL STANDARD NORME INTERNATIONALE

Automated Home Lighting Made Easy

lighting control Simple and scalable Flexible control every step of the way DESIGN INSTALL MAINTAIN

Team Catalyst ISSUED 22SEP2014. Organic Response. 134 William St Tenancy. Case Study. William St. Team Catalyst

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

Alarm Management Services

Mains-related EMC-issues associated with Lighting Equipment. P.A. Beeckman PGI/Philips Innovation Services EMC Kennismarkt Oost - October 12, 2012

ThermoControl 0 C - 10 C - 20 C - 30 C

The RCR Undergraduate Radiology Societies Association URSA

Australian/New Zealand Standard

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

HF Motion Sensor Introduction

Safer & quicker evacuation From Emergency Lighting Systems to Adaptive Evacuation Systems

SECTION 26 NX DISTRIBUTED INTELLIGENCE LIGHTING CONTROL SYSTEM HUBBELL CONTROL SOLUTIONS

GASTEC QA. Evaluation Guideline KE 192. Amendment A1 Rubber materials for seals and diaphragms for gas appliances and gas equipment

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

INTERNATIONAL STANDARD

, ,

IECRE OPERATIONAL DOCUMENT

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

Avigilon Control Center System Integration Guide

Transcription:

Introducing the Digital Illumination Interface Alliance The global industry alliance for DALI lighting control March 2019 1

DiiA: The global industry alliance for DALI DiiA the Digital Illumination Interface Alliance is an open, global consortium of lighting companies. We aim to grow the market for lighting-control solutions based on DALI. DALI, or Digital Addressable Lighting Interface, is an established protocol for bi-directional, digital communication between lighting-control devices. DALI-2 is the latest version of the DALI protocol. 2

Member companies 3

The strengths of DALI... DALI is a dedicated, standardized protocol for digital lighting control. DALI lighting systems are robust, scalable, cost-effective, reliable and flexible.... are extended and enhanced in DALI-2 DALI-2 is setting the standard for smart lighting control Focused on interoperability, backed by DALI-2 certification 4

Key features of DALI-2 DALI-2 focuses on multivendor interoperability, backed by certification. DALI-2 includes input devices (e.g. sensors), application controllers, and bus power supplies for the first time. DALI-2 now extends to all devices in a lighting-control system. DALI-2 includes more features and clearer specifications. DALI-2 has much more detailed and comprehensive testing requirements. DALI-2 is designed for backwards-compatibility with older DALI systems. 5

DALI-2 Certification 6

DALI-2 certification: Overview DiiA operates the DALI-2 certification and logo-licensing program DiiA member companies can to show compliance of lighting devices with IEC 62386 The DALI-2 logo can only be used on certified products. All DALI-2 certified products are listed in the online DiiA product database. Only DiiA members can certify their DALI-2 products. DALI-2 certification involves verification of test results by DiiA. In contrast, DALI version-1 product compliance is based solely on self-declaration, which has led to interoperability issues in the market. 7

DALI version-1 vs. DALI-2 DALI version-1 registration Successful test for compliance Using latest DALI version-1 test sequences DALI-2 certification Register product with DiiA Only possible for control gear No verification step for DALI version-1 registration Product can display DALI version-1 logo Product listed in DiiA online database Successful test for compliance Submit results to DiiA Results verified by DiiA Success DALI-2 certification granted Product can display DALI-2 logo Using latest DALI-2 test sequences x Failure Inform member 8

DALI-2 vs. DALI version-1 DALI-2 certification brings the promise of significantly improved multi-vendor interoperability compared with DALI version-1 systems. Testing procedures for DALI-2 are much more detailed and comprehensive, and are reviewed and updated as required. DiiA organizes regular test events to enable validation and further improvement of test sequences. DALI version-1 registration only applies to control gear. All other product types are NOT eligible to carry the DALI version-1 logo. All registered DALI version-1 devices are listed in the Product Database Registration is compulsory for control gear carrying the DALI version-1 logo 9

DALI-2 vs. DALI version-1 Feature More-comprehensive Test Specifications that are focused on product interoperability? New and updated Test Sequences supplied by DiiA to members? Includes control devices (input devices, application controllers)? DALI-2 certification Yes Yes Yes DALI version-1 registration No No No Test results verified by DiiA? Yes No All products displayed on DiiA website? Yes Yes Fee for each product? Yes (except luminaires) No 10

DALI-2 certification: Key steps Step 1 DiiA creates and maintains DALI-2 Test Specifications 2 DiiA develops software Test Sequences on approved test equipment 3 Member companies execute the required tests for each product 4 If all tests pass, the member company submits the results via the DiiA website 5 DiiA verifies the results. If all data is OK, then DALI-2 certification is granted 6 Relevant data is displayed in the online DiiA Product Database Notes DALI-2 Test Specifications are based either on IEC 62386 or on new DiiA Specifications DiiA members can download the current Test Sequences from our website >> Link Members can also use the services of accredited DALI test houses >> Link Certification credits (one per product) must be prepurchased before products are submitted The member company may use the DALI-2 logo on the certified product Visibility of a product in the database confirms that the product is certified >> Link 11

DALI-2 certification: Detailed process Obtain latest test sequences From DiiA website Test for compliance Pass? No Analyze results Yes Credits visible on website Purchase certification credits From IEEE-ISTO Submit results Results verified by DiiA On DiiA website Products displayed in online database Certification granted Waiver? No Yes Verification by DiiA Certification Manager OK? Yes No Inform member 12

DALI-2 Specifications & Certified Products 13

DALI-2 specifications and certification DiiA specifications provided to IEC for inclusion in IEC 62386 IEC 62386 Standard (multiple Parts) DiiA Specifications (e.g. Parts 25x) DiiA feedback & amendments provided to IEC DALI-2 Test Procedure specifications Created & maintained by DiiA CERTIFICATION Third-party software provider (Lichtvision) DALI-2 Test Sequences (software) Test hardware (ProbitLab or ProbitLab2) DALI-2 testing (by DiiA member or Accredited Test House) Verification (by DiiA) DALI-2 Certification 14

IEC 62386 standard Purchase standards via the IEC website More details on IEC 62386: DiiA website Red text = DALI-2 versions published Part 101: General requirements System components Part 102: General requirements Control gear Parts 2xx: Particular requirements for control gear Part 104: General requirements Wireless and alternative wired systems In progress Part 105: General requirements Firmware update In progress Part 103: General requirements Control devices Parts 3xx: Particular requirements for control / input devices Published: Part 201: Fluorescent lamps Part 202: Self-contained emergency lighting Part 203: Discharge lamps (excluding fluorescent lamps) Part 204: Low voltage halogen lamps Part 205: Supply voltage controller for incandescent lamps Part 206: Conversion from digital signal into DC voltage Part 207: LED modules Part 208: Switching function Part 209: Colour control For Parts 207, 209 and others, DiiA adapts DALI version-1 test specifications for use with DALI-2. Published: Part 216: Load referencing Part 217: Thermal gear protection Part 218: Dimming curve selection Part 220: Centrally-supplied DC emergency operation Part 221: Load shedding Part 222: Thermal lamp protection Part 224: Integrated light source In progress: Part 219: Power measurement Part 223: Light-output compensation over lifetime Part 225: Colour Tc Part 226: Colour xy Published: Part 301: Push buttons Part 302: Absolute input devices Part 303: Occupancy sensors Part 304: Light sensors Part 332: Input control devices - Feedback Part 333: Manual configuration In progress: Part 307: Relative input devices Future part: Part 305: Colour sensor Updated: Dec 2018 15

DiiA specifications (Parts 25x and Aux) DiiA published a set of five new specifications in 2018 Integrated DALI power supplies, auxiliary power supplies, and data storage/retrieval for asset management, energy reporting and diagnostics >> More details Specification Name (notes) Specification Name (notes) DALI Part 250 AUX Power Supply Integrated Bus Power Supply (Does not involve DALI memory banks) DALI Part 251 DALI Part 252 DALI Part 253 MB1 Extension (Luminaire data for asset management) Energy Reporting Diagnostics & Maintenance DiiA is currently developing a new name and logo to indicate products with the features and functions defined in these new specifications. 16

DALI-2 certification: Product types DALI-2 certification has already been achieved for the following product types: LED drivers (control gear for LED modules) Single-master application controllers (control devices) Multi-master application controllers (control devices) Standalone bus power supplies Bus power supplies integrated with control gear or control devices DALI-2 certified products can carry the DALI-2 logo DALI-2 certified products are traceable via the online, public database 17

DALI-2 certification Bus power supply DALI bus Application controller* LED driver Input device* Control gear LEDs * Application controllers and input devices are two different types of control device = certification possible Diagram shows one possible example of a DALI system 18

DALI-2 certification: Next steps Further product types, features and functions will be added to the DALI-2 program. DiiA is writing test procedures for the following Parts: Specifications Parts 301 to 304 Part 209 Parts 25x Part 202 Subject Input devices (push buttons, occupancy sensors, light sensors) Colour control gear New DiiA specifications for data storage/reporting and power-supply Self-contained emergency lighting See our Timeline for updates. 19

DALI-2 LED drivers Many DiiA members have certified DALI-2 control gear (LED drivers) 20

DALI-2 control devices & bus power supplies DALI-2 standalone bus power supply DALI-2 single-master application controllers, with integrated bus power supplies DALI-2 multi-master application controller 21

Community members and DALI-2 luminaires Luminaire makers are eligible for Community registration No fee for Community registration, and no fee to use the DiiA Trademarks (including DALI logos) according to DiiA s rules. See DALI for luminaire makers DALI-2 luminaires contain DALI-2 certified components Listing of DALI-2 luminaires is open to Community members, as well as registered brands of Regular and Associate members 22

DALI trademarks and logos DiiA has the rights to registered Trademarks relating to DALI lighting products DALI and DALI-2 wordmarks DALI and DALI-2 logos DALI Trademarks can be used only by DiiA members Subject to the DiiA Trademark Guidelines DALI-2 logo: DALI logo: Used by DiiA members on their certified products only Products must be listed in the online Database May not be used for general marketing Used by DiiA members on their DALI version-1 registered products Products must be listed in the online Database May also be used for general marketing e.g. to show that companies are a DiiA member 23

DiiA Organization and Membership 24

DiiA member benefits There are two membership classes: Regular & Associate All DiiA members (Regular & Associate): Can certify DALI-2 products and register DALI version-1 products Receive updated DALI-2 Test Sequences Can use the DALI & DALI-2 Trademarks, according to DiiA rules Have access to the DiiA member website Can participate in the DiiA General Assembly In addition, Regular members: Can participate in Work Groups Can participate in interoperability test events (plugfests) Have access to draft DiiA deliverables e.g. new specifications Are eligible for Board of Directors membership 25

DiiA contact information Website www.digitalilluminationinterface.org Ruud van Bokhorst General Manager GM@digitalilluminationinterface.org E-mail info@digitalilluminationinterface.org 26

27