Extreme 4000 Duct Kit

Similar documents
HEPAir. Installation, Operation and Maintenance Manual. (Model shown may not be reflective of your model) Manufactured by:

Booster Fan Ducting Kit Installation Instruction for Hybrid Electric Heat Pump Water Heaters

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Easy installation in both new construction and retrofit. READ AND SAVE THESE INSTRUCTIONS Installer: leave this guide with homeowner.

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

Easy installation. EZ80N EZ Fit Ventilation Fan INSTALLATION GUIDE READ AND SAVE THESE INSTRUCTIONS. Table of Contents

Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer

ENERGY STAR Qualified Homes

SAFETY AND INSTALLATION MANUAL MODEL 8100

Duct Leakage, Sealing & Testing

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Installation Guide. Model: IC15- MF Model: IC15- MFSilent Model: IC30- MF Model: IC30- MFSilent

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Ducted Split Wine Cellar Cooling Systems

Installation Electric Dryers Instructions 01

Ducted Split Wine Cellar Cooling Systems

WM-4510HZD Installation Instructions

Ducted Split 50Hz Wine Cellar Cooling Systems Installation, Operation and Maintenance Guide WGS40, WGS75, WGS100, WGS175 Part No.

Ducted Split Wine Cellar Cooling Systems

EXTREME SERIES OWNER S MANUAL

EXTREME 5000 / & 8000 / OWNER S MANUAL

WhisperKOOL EXTREME OWNER S MANUAL

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

PLATINUM SPLIT TWIN TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option. The Coolest Thing In Wine Storage

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Ducted Split Wine Cellar Cooling Systems

Platinum Split TECH MANUAL

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

SPLIT System Cooling Systems

SECTION DUCTWORK

INSTALLATION MANUAL AND USER GUIDE

Ducted Split Wine Cellar Cooling Systems

SECTION (15820) - AIR DUCT ACCESSORIES

Ducted Split Wine Cellar Cooling Systems

EXTREME SERIES OWNER S MANUAL. Extreme 3500tiR Extreme 5000tiR Extreme 8000tiR Extreme 3500tiR FD Extreme 5000tiR FD Extreme 8000tiR FD

EXTREME SERIES OWNER S MANUAL. Extreme 3500tiR Extreme 5000tiR Extreme 8000tiR Extreme 3500tiR FD Extreme 5000tiR FD Extreme 8000tiR FD

INSTALLATION MANUAL AND USER GUIDE

PHANTOM SERIES OWNER S MANUAL. 24V Thermostat Conversion Kit. Phantom 3500 Phantom 5000 Phantom The Coolest Thing In Wine Storage

Residential HVAC System Design

breeze easytm model # F100-1W

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Pellet Stove. Flex Pipe. Appliance Connector

SER Series. Installation Manual. Energy Recovery Ventilators SER 1504 SER 2004 SER 3204D

e Bath Fan with Light User s Guide

SER Series. fantech. Installation Manual. Energy Recovery Ventilators. ser 1504 ser 1504n ser 2004 ser 2004n ser 3204d ser 3204n

OVEN PARTS For Model: KEHU309SSS06 (Stainless)

Installation Instructions Remote Blowers

INSTALLATION AND OPERATION MANUAL 90-Series

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Installation instructions for the T 9820 Gas Dryer

Platinum Split 4000 & Platinum Split 4000 Fully Ducted COLD WEATHER START KIT Installation Manual

QUANTUM SERIES VERSION 4 TECHNICIAN S MANUAL. 24V Thermostat Conversion Kit Option. Quantum SS9000 Quantum SS The Coolest Thing In Wine Storage

Easy installation in both new construction and retrofit. ZB90C ZB110C X2 Multi-Speed Ventilation Fan INSTALLATION GUIDE

COMMERCIAL GAS AND ELECTRIC STACKED WASHER/ DRYER INSTALLATION INSTRUCTIONS

e Bath Fan with Light User s Guide

DRYER INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

INSTALLATION GUIDE. Horizontal series. HRV MODEL 8160 and MODEL 8220 ERV MODEL 3160 and MODEL 3220

Snohomish County PUD #1 HEAT PUMP SYSTEM INSTALLATION STANDARDS

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP

DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Vertical Termination Part No: 3CGRVT 16 7/8" 18 Vent Pipe Extension Part No: 3CG18 9 7/8" Wall Hanger Part No: 3CGWH 7 7/8" 7 3/8"

PHANTOM SERIES OWNER S MANUAL. Phantom 3500 Phantom 5000 Phantom The Coolest Thing In Wine Storage

Dryer. User manual DV22K6800** DV22K A-00_EN (US)_ indd :15:41

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION AND OPERATION MANUAL Model BR70/BR130

Installation Instructions

A HEATER KIT With Diesel Engine Connection Fittings

INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR: ISLAND RANGE HOODS Models covered by this instructions: SU900, SUT900, SUE900, SU901, SU902, SU903

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

Gas and Electric Dryer user manual

INSTALLATION INSTRUCTIONS

REFRIGERATION SYSTEMS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation Instructions Exhaust Fan With Light

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

INSTALLATION MANUAL UN-CASED A COILS UPFLOW FOR COOLING/HEAT PUMPS FLEX COILS FOR FIELD INSTALLED TXV MODELS: UC LIST OF SECTIONS LIST OF FIGURES

Installation Instructions

e Bath Fan with Light User s Guide

READ AND SAVE THESE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS John Deere One Series; 1023E, 1025R and 1026R Models A HEATER KIT. Figure 1 (General Layout and Parts I.D.

Venting of Gas Fired Equipment RV

COLD WEATHER START KIT Ceiling Mount 4000

Bathroom Exhaust Fan/Fluorescent Light Combination

REFLECTOR PANS FOR HINGED ELEMENTS CONNECTOR BLOCK KIT TRIM RINGS FOR ABOVE PANS CONNECTOR BLOCK RANGE CORD REFLECTOR PANS FOR PLUG-IN ELEMENTS

INSTALLATION MANUAL LIST OF SECTIONS LIST OF FIGURES LIST OF TABLES SECTION I: SAFETY UIM-C-0214

ENGLISH. Dometic Environmental Corporation. Rev L-2484

Arctica Solar 1500 Series Heater Installation Manual

SECTION AIR OUTLETS AND INLETS

INSTALLATION MANUAL G*FD SERIES FULL-CASED A COILS UPFLOW/COUNTERFLOW/HORIZONTAL COOLING/HEAT PUMP MODELS: TABLE OF CONTENTS LIST OF FIGURES

Heat or Energy Recovery Ventilation System

Transcription:

Extreme 4000 Duct Kit by Vinothèque and WhisperKOOL Protecting Your Investment in Fine Wines

Extreme Duct Kit Parts List DuctingAdapter x 1 or 2 15 inches 15 inches 54 inches

Installation Step 1: Remove the grill from the unit by unscrewing the four screws that hold it in place. Step 2: Move the Ducting Adapter into place 2

Installation Step 3: Screw the Duct Kit into place using the same screws that held the grill in place.

Ducted Installation Use ductwork to connect the unit to the supply and return outlets in the wine cellar. Use only insulated ductwork to minimize cooling losses, prevent sweating, and reduce noise. Use ductwork on the condenser section to redirect or absorb sound, bring in outside air to the unit inlet, and/or exhaust the hot air out of the ambient space. Note: Do not exceed a total of 25 for each length of ductwork run and a total of 50 combined for both the supply and return lengths. Avoid crimping the flexible ducts. This chokes down the inside area and reduces the airflow causing the unit to operate erratically. Be sure all ducts and surfaces in contact with the airflow are insulated and have a vapor barrier on the outside. Uninsulated ducts and surfaces cause bare, exposed metal surfaces to sweat, further degrading the insulation and equipment cooling capacity. General Duct Recommendation Provide support for the flexible duct to prevent sags and bends. Stretch out the duct to make a smoother interior, which reduces air resistance. For 90 bends, use a 90 adjustable elbow (Ell). Do not squeeze or reduce the inside diameter of the ducts which reduces airflow. Use short and straight ductwork where possible. Remove the grilles and panels from the openings to connect the ductwork. Check that all fan blades move freely. Keep air paths free of loose foreign objects and debris. Connect the round flexible ducts to the WhisperKOOL Extreme using the duct collars provided with the duct accessory kit. Pull the outer plastic wrapping and insulation away from the end of the duct to expose the reinforced inside duct liner. Fasten the duct collar using tie straps or clamps around the inside liner. Secure the duct collar to the unit using the screws provided. Take care to not damage or bend the gasket. Use approved duct tape to seal all joints. Do not clamp around the outside insulation. It compresses and loosens over time. 23

Using Ductwork Cold Air to/from Wine Cellar Remove supply air grille to install ductwork between WhisperKOOL Extreme unit and the cellar. Connect the supply air ductwork from the cellar to the supply air outlet adapter flange at the WhisperKOOL Extreme unit. Connect the return air ductwork from the cellar to the return air inlet adapter flange at the WhisperKOOL Extreme unit. Warm Air to/from Wine Cellar Connect ductwork on the condenser to direct heat and air noise away from occupants. Connect ductwork to another space within the basement or out of the building if exhausted heat is undesirable. 24

Dual Outlet Duct Standard Ducted Installation Outside through the Wall 25

Remote Mount on Floor Outside Remote Mount 26

Attic Mounted System

WhisperKOOL