REPORT 58 COMMERCENTRE DRIVE, LAKE FOREST, CA 963 Project No. G119188 Date: March 13, REPORT NO. 119188LAX-4 TEST OF ONE LED WASH MODEL NO. COLOUR CHORUS 4 RENDERED TO ELATION PROFESSIONAL 61 S. EASTERN AVE COMMERCE, CA 94 USA TEST: Electrical and Photometric tests as required to the IESNA test standard. STATEMENT OF LIMITATION: AUTHORIZATION: STANDARDS USED: This report must not be used by the client to claim product certification, approval, or endorsement by ALA, NIST, or any agency of the federal government. The testing performed was authorized by signed quote number Q551956. The following American National Standards or Illuminating Engineering Society of North America Test Guides were used in part or totally to test each specimen: IESNA LM-79-8: Electrical and Photometric Measurements of Solid State Lighting DESCRIPTION OF SAMPLE: DATES OF TESTS: The client submitted one production sample of model number COLOUR CHORUS 4. The sample was received by Intertek on March 1,, in undamaged condition and one sample was tested as received. The sample designation was LAN31119-4. March 11, This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
SUMMARY Model No.: Description: COLOUR CHORUS 4 LED Wash Criteria Total Lumen Output (Lumens) Total Power (W) Luminaire Efficacy (LPW) Power Factor Result 3919. 133. 9.4.98 EQUIPMENT LIST Equipment Used LSI High Speed Mirror Goniometer Elgar Power Supply Yokogawa Power Analyzer Temp. & RH Meter Extech Instruments Stop Watch Tape Measure Model Number 644T CW151 WT1 971 36551 33-43 Control Last Date Calibration Number Calibrated Due Date 943 /5/ 3/5/ 944 VBU VBU 9 11/6/14 11/6/ 1178 1//14 1// 139 1/8/14 1/8/ 1491 1/8/14 1/8/ TEST METHODS Seasoning in Sample Orientation LED Products No seasoning was performed in accordance with IESNA LM-79. Photometric and Electrical Measurements Distribution Method A LSI Type C High Speed Model 644 Mirror Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to stabilize for at least thirty minutes before measurements were made. Electrical measurements including voltage, current, and power were measured using the Yokogawa Power Analyzer. Some graphics were created with Photometrics Plus software. Report No. 119188LAX-4 of 5 Date: March 13,
RESULTS OF TEST Photometric and Electrical Measurements at Ambient Temperature (5 C +/- 1 C) Distribution Method Intertek Sample No. LAN31119-4 Base Orientation UP Voltage {Vac} 1. Current (ma) 1183 Power (Watts) 133. Power Factor.98 Absolute Luminous Flux (Lumens) 3919. Lumen Efficacy (Lumens Per Watt) 9.4 Intensity (Candlepower) Summary at 5 C - Candelas Maximum Candela Value: 9,737.7 Angle 5 1 5 3 35 4 5 55 6 65 7 75 8 85 9 754 1655 5187 318 114 618 348 194 1 87 5 49 65 14 8.5 19965 1397 4998 181 171 596 319 161 1 9 44 4 3 9 5 6 19748 1395 491 95 996 534 84 5 89 75 58 5 9 1 6 67.5 1931 1169 4811 9 941 5 51 133 89 58 38 18 11 3 9 18537 988 463 1919 889 46 3 143 85 64 5 19 Report No. 119188LAX-4 3 of 5 Date: March 13,
RESULTS OF TEST (cont'd) Illumination Plots Illuminance - Cone of Light Mounting Height: 1 ft. Isoillumination Plot Zonal Lumen Summary and Percentages at 5 C Zonal Lumens and Percentages at 5 C Zone Lumens -3 353-4 3739-6 387 6-9 48.4-9 3918.7 9-18.5-18 3919. % Luminaire 9.1% 95.4% 98.8% 1.%.5%.% 1.% Zone -1 1- -3 3-4 4-5 5-6 6-7 7-8 8-9 9-1 Lumens 7 145 535.4 9. 83.6 47.4 8.3 13.5 6.7.5 % Luminaire 4.% 36.4% 13.7% 5.3%.1% 1.%.7%.3%.%.% Report No. 119188LAX-4 4 of 5 Date: March 13,
PICTURE (not to scale) X CONCLUSION The results tabulated in this report are representative of the actual test samples submitted for this report only. The data is provided to the client for further evaluation. Compliance to the referenced specification requirements was not determined in this report. In Charge Of Tests: Report Reviewed By: Ameet Alawi Technician Lighting Division Kenda Branch Lighting Performance Team Lead Lighting Division Attachment: None Report No. 119188LAX-4 5 of 5 Date: March 13,