Automax XCL Series UltraSwitch. Switch box

Similar documents
Automax PS/PM Series UltraSwitch. Switchbox

Worcester Controls PS/PM Series UltraSwitch. Switchbox

EP5 Electropneumatic positioner

PT700. Product Information

D3 Digital Positioner. Product Information

D3 Digital Positioner. Product Information

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump

Limitorque FR Shells Removable Intumescent Fireproof Coatings

Valtek Guardian II Metal Bellows Seal Valtek Guardian II

Guardian II Metal Bellows Seal. Valtek Guardian II Metal Bellows Seal Control Valves

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Enraf Servo Gauge 854 ATG

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Rosemount 752 Fieldbus Remote Indicator

Enraf Servo Gauge 854 XTG

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

Model 144H. Product Data Sheet , Rev DB February Content

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Explosion Proof Line Powered Telephone Ringer

Flowserve Logix. 420 Digital Positioner. Experience In Motion. Redefining low cost ownership for your enterprise

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ELECTRICAL EX EQUIPMENT

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

The Sub-Mini Hermet. OEM Pressure Switches Sub-Mini-Hermet and Omni

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Limit Switch Box YT-870/875 SERIES

your dust explosion protection experts

Dräger Polytron 8200 Stationary gas detector (CatEx)

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Ar-Mite TM Low Flow Armored Flowmeter

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

custom cabinets and junction boxes

Dräger Polytron 5720 IR Toxic Gas Detection

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

PROCESS AUTOMATION PEPPERL+FUCHS BEBCO EPS 6000 SERIES PURGE AND PRESSURIZATION SYSTEM

The SharpEye 40/40I (IR3) Flame Detection

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

UL HAZARDOUS LOCATIONS SERVICES

Certificate of Compliance

Dräger PIR 3000 Detection of flammable gases and vapours

WAGO-I/O-SYSTEM 750 Explosion Protection via Intrinsic Safety

Rosemount 2088 Absolute and Gage Pressure Transmitter

BDI-FLX B URST SY STE M BENEFITS BDI-FLX AVAILABLE FOR INDUSTRIAL AND SANITARY APPLICATIONS

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Dräger Polytron 5720 IR Detection of carbon dioxide

Rosemount 3100 Series Ultrasonic Level Transmitters

MT3750C Series. Metal Tube Variable Area Flowmeters. Ships in 5 days. Overview. Product Description. Features. Variable Area

Certificate of Compliance

Rosemount 2090P Pulp and Paper Pressure Transmitter

Annubar Flowmeter Series

PROCESS AUTOMATION PRECISE VALUES LEVEL MEASUREMENT TECHNOLOGY

INSTRUCTION & SERVICE MANUAL

How Limit Switches Can Stop Machines from Going Boom

Dräger Polytron 8310 Stationary gas detector (DSIR)

SYSTEMS PRODUCT OVERVIEW

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

MICRO SWITCH BX/BX2 Series

Ultrasonic Switches. Features & Benefits

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Level instruments. Continuous level measurement - Ultrasonic transmitters. SITRANS Probe LU. Overview. Configuration

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Rosemount 3051CFC Compact Flowmeter

Genie Heated Regulator Installation & Operation Instructions

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Logix Positioner Overview July 2015 Barrancabermeja. Ruben Izarra

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

The SharpEye 40/40R (IR) Flame Detection

Dräger Polytron 7000 Fixed gas detector

Integrated Solutions Low Voltage Systems

Dräger Flame 2500 Flame Detection

Continuous level measurement Ultrasonic transmitters

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Guide for hazardous areas

Technical Data. Sizes: ANSI Inches (DN) 2-1/2 (DN65), 3 (DN80), 4 (DN100), 5 (DN125), 6 (DN150), 8 (DN200), 10 (DN250)

PANELBOARD PROTECTION ON A GLOBAL SCALE

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8720 IR Detection of carbon dioxide

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Certificate of Compliance

Dräger Polytron 8700 IR Detection of flammable gases and vapors

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

Description. Applications

Trusting in experience. Relying on expertise. Focusing on solutions. Bebco EPS Purge+Pressurization Product Overview

Metal Tube Variable Area Flowmeter with Optional Electronics based on Smart Meter Manager Technology

WH EN IGH T T C LO SED

Quick Start Manual July pointek CLS100

The SharpEye 40/40M (Multi IR) Flame Detection

PILOT VALVE ENCLOSURES

Rosemount 248 Temperature Transmitter

Certificate of Compliance

Belt Conveyor Safety Monitoring Devices

Ultrasonic switch. Pointek ULS200. Quick Start Manual 03/2013. Milltronics

Rosemount 3100 Series Ultrasonic Level Transmitters

Transcription:

Automax XCL Series UltraSwitch Switch box TM

Featuers Approvals Materials Hazardous locations approvals The XCL Series UltraSwich has approvals to cover global needs. XCL/XML-Series Ultraswitch Description The XCL Series UltraSwich provides cost efficient, accurate and reliable position signaling for hazardous locations. The sturdy enclosure is offered in aluminum and is provided with multiple switch options. An external dome style indicator is available. The XCL is designed to be directly and easily mounted onto actuators for both rotary and linear indication. It may also be used as a junction box for direct connection of solenoid valves. Minimum two open terminals are always provided. Its compact housing has multiple mounting possibilities with two conduit entries and pre-wired switches to enable easy installation. It is designed to meet IP66 and NEMA Type 4X standards and is offered for general purpose/weather proof and for explosion proof hazardous locations. Features and Benefits Tool-free Quick-Set cams Multiple switch options Optional 4-20mA feedback signal Easily accessed pre-wired terminal strip Minimum two open terminals are provided All Switch Options Flame-proof ATEX(SIRA 06ATEX 3392X) II 2 G Ex d IIB T5 II 2 D Ex td A21 IP 65 T5 @ -20 C Tamb +55 C, EN 60079-0:2004 EN 60079-1:2004 EN 61241-0:2006 EN 61241-1:2004 IECEx Ex d IIB T5 Ex td A21 IP 65 T5 @ -20 C Tamb +55 C, IEC 60079-0:2004 (Ed.4) IEC 60079-1:2003 (Ed.5) IEC 61241-0:2004 (Ed.1) IEC 61241-1:2004 (Ed.1) InMetro BR Ex d IIB T5 T5 @ -20 C Tamb +55 C Mechanical Switch Options Explosion-Proof (CSA) Class I, Divisions 1, Groups C and D Class II, Divisions 1, Groups E, F and G Class II, Division 2, Groups F and G Class III (CSA only) FM U.S. Canada Intrinsically Safe Switch Options Switch Type: MG, PE, PT, P4, N8, NQ, NP Class I,II,II Division 1 Groups A, B, C, D, E, F, G T5 Proximity / Solid State Switch Options Explosion-Proof (CSA) Class I, Division 1, Groups C and D Class I, Division 2 Groups A, B, C and D T3 Class II, Divisions 1, Groups E, F and G Class II, Division 2, Groups F and G Class III (CSA only) NOTE: When using a sealed proximity switch (P4, P5, PP) in North American Division 2 applications, a sealing fitting is not required. Flame proof housing of aluminum Conduit entries (2x) 3/4 NPT or (2x) M25x1.5mm Materials Cam shaft: AISI 304 Housing: Aluminium, powder coated Screws, washers, springs, rings: AISI 303 Dome Indicator: Polycarbonate Label: Polyester

Switches Analog Feedback & Communication Switch Options Switch Option Manufacturer Part Number Load Capacity M1 - SPDT Mechanical Honeywell MicroSwitch V7-1C13D8-201 15 A (1/2 HP) at 125 V AC/ 0,5 A at 125 V DC MG - SPDT Gold Mechanical Honeywell MicroSwitch V7-1D11D8-201 1 A at 125 V AC/ 50 ma at 24 V DC M3 - DPDT Mechanical Cherry E19-00A 15 A (3/4 HP) at 125 V AC MB - DPDT Mechanical Licon 22-104 10 A (1/2 HP) at 125 V AC P4 - SPST Proximity Aleph PS-6132 0.35 A at 140 V AC / 1 A at 50 V DC (50 W Max.) P5 - SPDT Proximity Hamlin 59135-030 0.25 A at 120 V AC / 0.25 A at 28 V DC (3 W Max.) PE - SPDT Sabre Proximity Flowserve XA0199 1 A at 120 V AC / 1 A at 24 V DC (25 W Max.) Transmitter 4-20 ma The XCL offers a 4-20mA feedback signal for true non-local position indication. The built-in pcb and potentiometer uses proven and reliable technology, leaving you with a clear view of actual position. A complementary equipment to the top mounted dome indicator. PP - SPDT Phazer Proximity Flowserve XA0155 3 A at 120 V AC / 2 A at 24 V DC (100 W Max.) PT - SPST BRS Proximity Flowserve XA0157 3 A at 120 V AC / 0.5 A at 24 V DC N8 - Solid State Proximity Pepperl + Fuchs NJ2-V3-N NP- Solid State Proximity Pepperl + Fuchs SJ3.5-N NQ - Solid State Proximity Pepperl + Fuchs NJ4-12GK-N NAMUR Sensor Output / 5 25 V DC Supply Load Current <1 ma (w/target) / > 3 ma w/out Target NR - Solid State Proximity Pepperl + Fuchs NJ4-12GM40-E1 PNP Sinking / 200 ma max. Current / 10 60 V DC NS - Solid State Proximity Pepperl + Fuchs NJ4-12GM40-E2 NPN Sourcing / 200 ma max. Current / 10 60 V DC NJ - Solid State Proximity1 IFM Efector IN0097 20-250V AC/DC NO 2-Wire Communication through AS-Interface (AS-i) XCL series can be equiped with optional AS-i communication capabilities. This technology offers a very simple, flexible and cost effective network system.

XCL Series Coding Dimensions (mm) Brand sticker Blank Automax Shaft N Namur VDI/VDE 3845 Connections (cable entry) XCL 2 x 3/4 NPT XML 2 x M25 x 1,5 157 Indicator option 1 Flat cover without indicator U Dome, Red/Green 68 68 Qty of switches 0 0 switches 1 1 switch 2 2 switches 4 4 switches 135 Switch options M1 SPDT Mechanical switches 250VAC 10A MG SPDT Mechanical switches gold plated M3 DPDT Mechanical Cherry MB DPDT Mechanical Licon P4 SPST proximity P5 SPDT proximity PE Sabre SPDT proximity PP Phazer II SPDT proximity PT BRS SPST Phazer II proximity N8 P+F NJ2 V3 N (Namur) NQ P+F NJ4-12GK-N (Namur) NR P+F 12GM40-E1 (3 wire NPN NO) NS P+F 12GM40-E2 (3 wire PNP NO) NP P+F SJ 3,5-N (Namur) NJ IFM IN -2002-ABOA FZ AS-i controller card 2,0 incl. 2 proximity switches 19 19 (2) PLACES 3/4" NPT OR M25-1.5 CONDUIT ENTRY (BOTH SIDES) 76 92 54 148 231 MINIMUM CLEARANCE FOR ADJUSTMENTS AND INSPECTION 29 Certificate 14 General Purpose 18 ccsaus Cl.I, Div1, Gr.CD / Cl.II, Div1, Gr.EFG, Cl.III. ATEX II 2G, Ex d IIB/Ex td 19 ATEX II 2 G EEx d IIB T4-T6, II 2 D Ex td A21 IP65 25 IEC Ex approval Ex d IIB T4-T6, II 2 D Ex td A21 IP65 26 Inmetro BR Ex d IIB T5 27 ccsaus IS class I, II, III Div1, Gr.ABCDEFG T5 28 ccsaus Cl.I, Div2, Gr. A,BC&D. 30 Kosha Ex d IIB T5 M1 Metal plate ccsaus Cl.I, Div2, Gr. A,BC&D. M2 Metal plate ccsaus Cl.I, Div1, Gr.CD / Cl.II, Div1, Gr.EFG, Cl.III. Analog Output 0 None T 4-20 ma transmitter M6-1 X 9 DEEP (4) PLACES SIDE MOUNTING SURFACE (4) PLACES 42 EXTERNAL GROUND SCREW LOCATION (BOTH SIDES) 23 10 25 4 FLATS (NAMUR SHAFT) Wiring options 0 None Minimun extra terminals 2 2 (standard) 4 4 (Optional) 6 6 (Optional, not possible for all switch options) Acessories 0 None L Cover bolts lubricated with grease P 180 Pot ( for analog options: A, B, C) V Viton O-rings 87 127 MINIMUM CLEARANCE FOR ADJUSTMENTS AND INSPECTION Housing/Surface treatment 0 Black polyester powder coat Example NXCLU2M1-18-00200

Flowserve Corporation Flow Control Division 1978 Foreman Drive Cookeville, Tennessee 38501 USA Phone: +931 432 4021 Fax: +931 432 5518 Flowserve Flow Control GmbH Rudolf-Plank Strasse 2 D-76275 Ettlingen GERMANY Tel: +49 (0) 7243 103 0 Fax: +49 (0) 7243 103 222 E-mail: argus@flowserve.com Flowserve Flow Control (UK) Ltd. Burrell Road Haywards Heath West Sussex United Kingdom RH16 1TL Phone: +44 1444 314400 Fax: +44 1444 314401 Flowserve Flow Control Benelux Rechtzaad 17 4703 RC Roosendaal THE NETHERLANDS Tel: +31 (0) 30 6771946 Fax: +27 (0) 30 6772471 E-mail: fcbinfo@flowserve.com p/n: FCD AXENBR0010-04 Flowserve Spa Via Prealpi, 30 20032 Cormano (Milano) ITALY Tel: +39 (0) 2 663 251 Fax: +39 (0) 2 615 18 63 E-mail: infoitaly@flowserve.com Hazardous Locations Flame proof / Explosion proof Intrinsically safe Non-Incendive Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation and Maintenance (I & M) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2015 Flowserve Corporation, Irving, Texas, USA. Flowserve and PMV are registered trademarks of Flowserve Corporation. Flowserve Ahaus GmbH von-braun-str. 19a 48683 Ahaus Phone: +49 2561 686-119 Fax: +49 2561 686-109 Flowserve Corporation No. 35, Baiyu Road Suzhou Industrial Park Suzhou 215021, Jiangsu Province, PRC Phone: +86-512-6288-1688 Fax: +86-512-6288-8737 Flowserve Australia Pty Ltd Flow Control Division 14 Dalmore Drive Scoresby, Victoria 3179 Austrialia Phone: +61 3 9759 3300 Fax: +61 3 9759 3301 Flowserve Pte Ltd No. 12 Tuas Avenue 20 Singapore 638824 Phone: +65 6879 8900 Fax: +65 6862 4940 Flowserve do Brasil Ltda Rua Tocantins, 128 - Bairro Nova Gerti São Caetano do Sul, São Paulo 09580-130 Brazil Phone: +5511 4231 6300 Fax: +5511 4231 6329-423 flowserve.com