Implementation of Building Management System using Renewable Energy Source (Solar), PLC and SCADA

Similar documents
II. METHODS AND MATERIALS

Design & Control of an Elevator Control System using PLC

PLC Based Washing Machine

STUDY OF AUTOMATED HOME SECURITY SYSTEM USING FPGA.

Real Time Automation Applications Using Millenium Crouzet PLC

VEHICLE SAFETY WITH DIALLING SYSTEM AND AUTOMATED LOCATION TRACKER

Intelligent monitoring system for automobiles

Implementation of Auto Car Washing System Using Two Robotic Arms

Industrial and home safety Management using GSM

Design and Development of Industrial Pollution Monitoring System using LabVIEW and GSM

LPG GAS LEAKAGE DETECTION, MONITORING AND CONTROL USING LabVIEW

AUTOMATIC STREET LIGHT CONTROL SYSTEM USING MICROCONTROLLER

DRAGER MONITORING, DETECTION OF GAS HAZARDOUS AND AUTOMATIC BOOKING

XBee Based Industrial And Home Security System

MICANS INFOTECH

Pi Cam Based Smoke/Fire Alerting System

Cost Effective Home Automation System

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

D-TECT 2 IP. GJD230 IP Motion Detector

Characteristics of different sensors used for Distance Measurement

International Journal of Computer Engineering and Applications, Volume XII, Special Issue, March 18, ISSN

Laptop / PC Programming Manual

PLC Based Control and Monitoring in Ship

End To End Optical Beam Smoke Detector. Additional Information

Ontech GSM 9040/50. Reference Manual English -1 -

MICROCONTROLLER BASED HOME AUTOMATION SYSTEMS

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE STAND-ALONE FAAST LT MODELS FL0111E FL0112E FL0122E. 367 mm.

How to use the BTRM in Remote Enclosures

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

GORAKSHAK : AN AUTOMATED FARM VIA IOT

D-TECT 3 IP. GJD260 IP Motion Detector

[Patil* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Android Controlled Fire Fighting Robot

A REVIEW ON GREEN TECHNOLOGY IN HVAC

Wireless Notice Board using GSM with Fire Detector

PRODUCT LYNC IoT 37. PRODUCT: LYNC IoT

[ [ ADMIN PANEL USER GUIDE

Electronic Pellet Burner Controller NPBC-V3-1

Innovative EEE mini-projects list

Duct and Rough Service Carbon Monoxide Sensor

E N G L I S H FIRE ALARM ASPIRATION SENSING TECHNOLOGY QUICK INSTALLATION GUIDE ADDRESSABLE FAAST LT MODELS MI-FL2011EI, MI-FL2012EI AND MI-FL2022EI

Subject Description Form

Portable Fire Detector

PWM. Solar Charge controller with Ethernet. Solar Smart PWM 20Amp. Hardware Description : Release : 19 June 2014

Real Time Smart House Data Logging System Using LabVIEW

Hazardous Gas Detection using ARDUINO

Security System. User s Guide for the Text Command Center

Intelligent Fire Detection and Visual Guided Evacuation System Using Arduino and GSM

A Cost Effective Embedded Design for Security and Automation in Industries

Smart Home: Controlling and Monitoring Households Appliances Using Gsm Network

NU2 Smart Power Supply (SPS) Manual

ROBOT: HOME AUTOMATION SYSTEM USING RASPBERRY PI AND SENSORS

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

Implementation of Multivariable Self Tuning Temperature Controller and LIW Feeder for an Extruder Machine

Guillermo Alberto Pérez Guillen Automation Home

DCU 305 R2/R3. Troubleshooting Manual

Elderly Care Alarm System

EnvironmentalMonitoring

Smart Office Automation System for Energy Saving

Multi Security System

Construction of An Automatic Power Switch using Infrared Motion Sensor

RTO. User guide 05/

Added password for IP setup page : Password must be in IP format!

Fin-Fan Control System

Danfoss gas detection unit Type GD Heavy Duty

rvm4c Installation Guide Remote Video Module

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

3. Intended use. 4. Function. 1. Product characteristics. 2. Safety. Functional description. Channel A light. Motion detector

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Electronic Pellet Burner Controller NPBC-V3M

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Home Security and Safety System Using Arduino Mega 2560 Controller

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Design and Implementation of Wireless Gas Sensing Network for Preventing Industrial Calamity

LIQUEFIED PETROLEUM GAS DIFFUSER Home automation based fire security.

International Journal of Scientific & Engineering Research Volume 9, Issue 2, February-2018 ISSN

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Halton SAFE / 7.14 user guide and installation instructions

Toxic Gas and Radiation Detection Monitoring Using IOT

Installer Manual KNX Touchscreen Thermostat

Monitoring Solutions

AUTOMATIC ROOM LIGHT AND FAN CONTROLLER WITH BI- DIRECTIONAL VISITOR COUNTER

Paradox Integration Module Settings Guide

For Complete Fire and Gas Solutions

Module Features are-configurable, no module jumpers to set

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Development of a Sensing Module for Standing and Moving Human Body Using a Shutter and PIR Sensor

ENACTMENT OF SCADA SYSTEM FOR JUDICIOUS DWELLING

Single Story Enclosed Shopping Mall Smoke Control with FSCS Override - Metasys System Extended Architecture

Danfoss gas detection units

A Survey Paper on Design & Control of an Elevator for Smart City Application

WiFi GSM APP Smart Home Security System

BURGLAR ALARM USING ARDUINO AND PIR SENSOR WITH SMS ALERT Burgoji Santhosh Kumar 1, S.Ramesh 2 1

Frequently asked questions: Intelligent Transmitter Series

Model 17A00 Expansion Enclosure

Automations and ACLinks. Technical Support Engineering Rosslare Security NA For more information please see

MINERVA MZX125 Digital Addressable Fire Detection System

Smart Gas Booking and LPG Leakage Detection System

Total Connect Box. User manual

Configuration and Operation Manual for the Unipos

Transcription:

Implementation of Building Management System using Renewable Energy Source (Solar), PLC and SCADA Omkar Naik 1, Shreya Pomaje 2, Prof. S S Tamhane 3 1,2BE & Pune, 3Dept. of Electrical Engineering, NBNSSOE, Maharashtra, India ----------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - Automation is used to improve quality and quantity of desired work not to reduce manpower. There are growing expectations for comforts and services in commercial places/residencies, so Building Management System helps for fulfilling these expectations. Every day it is a challenge to manage multiple networks, systems and control components in buildings with maximum efficiency and comfort in future. A good building automation system can help to reduce operating cost. BMS is a controller used to manage and control the various applications in buildings, ensuring reduction in operating cost as well as energy conservation in building. In the current topic, control of various applications is done by using PLC and SCADA, for various applications like: 1. Window Shutter 2. Fire Alarm and Fire sprinkler 3. Lighting control (Internal & External) 4. Garden system 5. Smart underground Parking 6. Elevator 7. Electrification system (Solar) 8. Reuse of water 9. Segregation of Plastic waste Key Words: Building Management, PLC and SCADA, Renewable Energy Source, Solar 1. INTRODUCTION Automation is used to improve quality and quantity of desired work not to reduce manpower. There are growing expectations for comforts and service in commercial places/residencies, so Building Management System helps for fulfilling these expectations. Every day it is a challenge to manage multiple networks, systems and control components in buildings with maximum efficiency and comfort in future. A good building automation system can help to reduce operating costs. BMS is a controller used to manage and control the various applications in buildings, ensuring reduction in operating cost as well as energy conservation in building. Under this project title, there will be implementation of the proposed applications listed above in the prototype model of building. The working of each application depends on the particular sensor. 2. LITERATURE REVIEW: Building Management System Using PLC and SCADA by Suresh Kumar, Jitendra Prasad Rajwar, Abhay Kumar Thakur: The controlling unit in building management system automation is a PLC. Every device in an installation is connected to the PLC. When a user wants to interact with a system an operator terminal, which is attached to a cabinet where the PLC is installed, is used. With this solution the user needs to be in front of the cabinet to interact with the system. BUILDING MANAGEMENT SYSTEM USING PLC AND SCADA There are various technologies available nowadays that can help reduce energy consumption and cost of existing buildings The project Building Management System using PLC AND SCADA has the both advantages of SCADA & PLC. 3.1 WINDOW SHUTTER (SENSOR USED: GAS SENSOR MQ2) In this application the working of sensor is done when there is any leakage of gas is detected and then a closed shutter of window gets opened the exhaust fan beside the window shutter gets start automatic to throw out the leaked gas at faster rate. After particular time period shutter goes at its original position i.e. closed position. 3.2 FIRE ALARM SYSTEM AND FIRE SPRINKLER. (SENSOR USED: SMOKE DETECTOR, FIRE SPRINKLER) In this system, there is smoke detector which will alert when there is fire in building/ floor. When smoke detector detects the smoke, which is present at particular area before catching fire and the signal goes to fire alarm and after getting signal it indicates detection of fire. The fire sprinkler is used to extinguish this fire. It burst when the temperature goes above preset value and pressurized water sprinkled on that particular area only, (the minimum area of 10ft *10ft and maximum of 50m *100m is covered by one sprinkler) at that time the command goes to the water tank to keep continuous water supply. There are three pumps namely Jockey pump, Main pump, Diesel pump (Supportive pump). The operation of these pumps is according to the pressure of 2019, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 1261

water in the pipe. The operating range of pressure for each pump is, 1) Jockey pump - Pressure - 5kg to 7kg 2) Main pump - Pressure - 3kg 3) Diesel pump - Pressure - 2kg 3.3 LIGHTING CONTROL (SENSOR USED: LDR, MOTION SENSOR) LDR (Light dependent resistor) used here is to control the intensity of the light in the room. According to the intensity of sunrays in the day time the intensity of light in the room is controlled. When water supply is given to the tank A, after filling the particular percentage of tank water is pumped into storage tank. The storage tank always remains full. When fire system is working the supply of water is from storage tank and for the garden system also water from storage tank is used. 3.7 SEGREGATION OF PLASTIC WASTE: Pyrolysis is a technique is used for segregation of plastic waste. Pyro means heat and lysis means break down. In this process plastic waste is not burned, but instead plastic is chemically broken down into Pyrolysis oil, the hydrocarbon gas and carbon black. Plastic to oil is environment friendly technology for disposal of plastic waste. The motion sensor is used for the staircase lighting. If there is presence of human being on stairs, the lights become turned ON until a person reaches on the last step. Also, there is timer used to turn off the light after particular time e.g. 15-20 seconds. 3.4 UNDERGROUND PARKING SYSTEM (SENSOR USED: MOTION SENSOR) When car/bike comes near the entrance gate the inductive sensor which is used to detect the metal things, senses the car and gate gets opened automatically. After passing the car from the gate it gets closed. Entrance of underground parking consists of speed breaker which acts as a sensor in the parking. When car touches the speed breaker the lights in the route of car turned on, and after some time lights become off. When car gets parked the indication on the entrance gate blink Red indicating the parking is full, it become Green when there is space to park. 3.5 ELEVATOR (SENSOR USED: MOTION SENSOR) The elevator is mainly used for transportation purpose (like goods transportation) in any commercial/residential buildings. In this project, the special use of elevator is for medical emergency. Consider on second floor there is a medical emergency and there are some persons wanted to go on first floor, pressing the medical emergency switch in the elevator it directly goes to second floor at the first time indicating medical emergency. Then it attends other floor applications. Figure 1: A block diagram of BMS using PLC and SCADA 4. WORKING PRINCIPLE Under this project title, there will be implementation of the proposed applications listed above in the prototype model of building. The working of each application depends on the particular sensor. The control of the system is done by using PLC and SCADA. The electrical power required for the controlling system is by using solar. 4.1 HARDWARE Gas sensor: The use of motion sensor is for opening and closing of the door of the elevator as the person detects by the sensor. 3.6 REUSE OF WATER: The building consists of water tanks. Here, there are two tanks, tank A and storage tank. The water from these tanks is also used for fire sprinkler system and garden system. Figure 2. Gas sensor MQ2 Analog gas sensor MQ2 is used here for window shutter application. It is used in gas leakage like smoke methane and liquefied flammable gas. It has wide detecting scope, fast 2019, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 1262

response and high sensitivity, simple drive circuit, stable and long life. The sensitivity can be adjusted using the potentiometer. The sensor detects the concentrations of combustible gas in the air and output is analog voltage. It consumes less than 150 M Amp at 5 V (only sensor current consumption). A digital output is also provided which is useful to trigger an external module when the threshold is crossed. For example, a relay can be triggered when gas or smoke threshold crosses a certain level. Sensitivity can be adjusted by the potentiometer. 4.2 FIRE ALARM SYSTEM AND FIRE SPRINKLER 4.3 LDR (LIGHT DEPENDANT RESISTOR): LDR is special type resistor used to sense the light. They can be connected in any direction. When the light intensity increases the resistance decreases and according to that the output is obtained. The output here is lamp and the light intensity is of sunrays. The operating voltage is 5 volts and current is in milliamps. The resistance is varied from kilo ohms to mega ohms. 4.4. PYROELECTRIC INFRARED (PIR) MOTION SENSOR: PIR infrared sensor module based on infrared technology, Figure 3. Fire alarm In fire alarm system there is fire detector which will alert when there is fire in building/ floor. When fire detector detects the fire, the signal goes to fire sprinkler, and it burst and pressurized water sprinkled on that particular area only, at that time the command goes to the water tank to keep continuous water supply. To maintain pressurized water flow jockey pump can be used. The temperature of agent used in the sprinkler is set at particular value (normally it is 58 deg Celsius), which will burst out when temperature goes above the set value. Figure 5. PIR sensor automatic control products. It has high sensitivity, high reliability, low power consumption, low voltage operation mode. In this project, this sensor is mainly used for garden system, light control (staircase light), elevator application. PIR sensors are used to detect motion from pets or humanoids from about 20 feet away. Operating Voltage Range: DC 4.5-20V Quiescent Current: <50uA Level Output: High 3.3 V or low 0V Wide operating voltage range: default voltage DC 3.6V - 20v. 4.5 INDUCTIVE SENSOR: The inductive sensor used here is for detecting the cars which comes in the parking section. Using the output of the sensor the lighting control in parking area is done. The indication about parking condition i.e. is it full or vacant is also taken from this sensor output which is obtained after car gets parked. Figure 4. Fire Sprinkler 2019, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 1263

4.6 SOLAR PANEL: 20W Solar Panel can be used for variety of functions. Then Choose the Ladder Diagram Mode: (after the ladder diagram is edited, convert the ladder diagram to the command mode and the SFC diagram through compiling) Aluminium body makes the panel Robust. Rated Power (Pmax) - 20W+- 3% Open Circuit Voltage (Voc) - 21.5V Short Circuit Current (Isc) - 1.30 A Voltage at maximum power (Vmp) - 17.7 V Current at maximum power (Imp) - 1.13 A Maximum system voltage - 600V. Dimension520 X 350 X 22 mm. Click on New under File, and the following image will show up; there will be some other selections listed on the function panel: Edit (E), Compile (P), Comment (L), Search (S), View (V), and we are to introduce these selections in order Figure 6. Solar Panel 5. SOFTWARE IMPLEMENTATION: The Software used for the PLC here is WPLSoft and For SCADA it is DIA view. The steps in operating WPLSoft are listed shortly below. After WPLSoft is activated, we are to undertake the creating of new documents, the step numbers (please refer to the program capacity of the MPU in use) of the designated programs, and the initial setup of the subject labeling within the program. 1. Create new files 2019, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 1264

Click on the Normally Open icon, or press the F1 function key 6. ADVANTAGES & DISADVANTAGES: There are growing expectations for comforts and service in commercial places/residencies, so Building Management System helps for fulfilling these expectations. 7. Advantages Many applications can manage at a time. 1. Energy conservation. 2. Less operating cost. 3. Use of PLC is more flexible as compared to other controllers. 4. Real time monitoring and controlling. What appears consequently are the device name and the comment dialog box, simply select a proper device name, device number and the comment, then press OK to complete the process. Click on the output coil icon, or press the F7 function key and repeat the above-mentioned procedure. 5. On the SCADA screen we can see the exact location of fault in the building monitored by PLC. 8. CONCLUSION In this present automated world, building management system can also be used for completing expectations of middle-class people regarding the building services and comforts, as it is having less operating cost and more beneficial from their point of view. 9. FUTURE SCOPE Use of PAC (Programmable automation controller) instead of PLC as it geared more towards complex automation system. These are better able to handle analog I/O and related control function, also it tends to provide larger memory capacity and more feature. IOT based building management system Remote controlling and monitoring Auto dialer system for security purpose. REFERENCES Click on the application command icon,, or press the F6 function key; click on All application or Other commands under the Function Type, then click on END command under Application or key in END directly, and finally, press Enter, then OK to complete the process. Click on the icon, and convert the edited ladder diagram into the command program through compiling, and after the compiling is completed, the number of Steps will show up on the left side of the Origin. If the graph of the ladder diagram appeared to be incorrect, the message dialog box would show up and point out the exact erroneous rows. Then Run the Program. [1] Building Management System Using PLC and SCADA by Suresh Kumar, Jitendra Prasad Rajwar, Abhay Kumar Thakur: The controlling unit in building management system automation is a PLC. [2] BUILDING MANAGEMENT SYSTEM USING PLC AND SCADA by P.Shunmugakani, A.Anbu selvan, R.Vivek ananth, K.Antony jerome Jeppiaar Engineering College, Rajiv Gandhi Salai [3] Effect of Building Management System on Energy Saving by Saeed Kamali1, a, Golrokh Khakzar2, b Soolmaz Abdali HajiAbadi3 [4] Research Methodology for Building Automation Performance Index Shariar Makarechi, Ph.D. yar@spsu.edu Roozbeh Kangari, Ph.D. roozbeh.kangari@coa.gatech.edu 2019, IRJET Impact Factor value: 7.211 ISO 9001:2008 Certified Journal Page 1265