MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

Similar documents
MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

2 shp 13 lc 1 36 t - 1 a

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

14 AC x

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

T P A 048 S 4 N 4 1 T

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

T S A 048 S 4 N 4 1 T

T P A 120 S 4 S N 1 Y

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

ELITE Series R-410A - Two-Stage Compressor

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

Visit us at For the latest technical information,

ELITE Series Variable Capacity

ELITE Series Variable Capacity

LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

MERIT Series R-410A - Upflow / Horizontal

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

MERIT Series R-410A - Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes August 2008

LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

T CLASS SPLIT SYSTEM UNITS Standard Efficiency R HZ Bulletin No March 2009 Supersedes April 2008

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

SSB. S CLASS SPLIT SYSTEM R 410A Two Stage Compressor 60 HZ A I R C O N D I T I O N E R S

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

13 GEP A L P - 1 A

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

T-Class AC and HP Units Up to SEER and 9.0 HSPF. Commercial Air Conditioners and Heat Pumps. True performance and rugged durability

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

CB X 32 mv

RGE 13 A T - 1 A

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

XC21. DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

True performance and rugged durability. Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 16.2 SEER

DAVE LENNOX SIGNATURE COLLECTION R-410A - Two-Stage Compressor - SilentComfort Technology

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Lennox 8 Series Single Zone - R-410A

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Commercial High-Efficiency Condensing Units

MACH N-407 Heat Pump Air-Cooled Chiller

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL SPECIFICATIONS

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

TECHNICAL SPECIFICATIONS

The most energy-efficient commercial split system* Commercial Air Conditioners and Heat Pumps SSB/SPB Models

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

C22FC Bulletin # October 1993 Supersedes May 1993

WCH5**4. Product Specifications

PRODUCT SPECIFICATIONS

Ruud Achiever Series Air Conditioners

R4H4. Product Specifications

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

C22 Bulletin # October 1993 Supersedes May 1993

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

R4H4. Product Specifications

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

PACKAGE AIR CONDITIONER

MERIT SERIES Downflow

DUAL ZONE CONTROL PANEL Zone Control For Residential Heating/Cooling Systems

TECHNICAL SPECIFICATIONS

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

PAJ3. Product Specifications

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

HSXA15 HSXB15. IMPORTANT Operating pressures of this R410A unit are higher than pressures in R22 units. Always use service equipment rated for R410A.

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

MAC N-407 Air-Cooled Chiller

Transcription:

PRODUCT SPECIFICATIONS HEAT PUMP OUTDOOR UNITS 4HPX MERIT Series R-40A Bulletin No. 20845 March 209 Supersedes February 209 MODEL NUMBER IDENTIFICATION SEER up to 6.00 HSPF up to 9.50.5 to 5 Tons Cooling Capacity - 8,000 to 6,000 Btuh Heating Capacity - 7,500 to 58,500 Btuh 4 HP x - 024-230 - 2 Nominal SEER Minor Revision Number Unit Type HP = Heat Pump Unit Voltage 230 = 208/230V-phase-60hz Refrigerant X = R-40A Nominal Cooling Capacity 08 =.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 042 = 3.5 tons 048 = 4 tons 060 = 5 tons

FEATURES CONTENTS Dimensions... 9 B Electrical Data... 7 Features... 2 Field Wiring... 0 Installation Clearances... 0 Model Number Identification... Optional Accessories... 7 C G H Sound Data... 0 Specifications... 7 TXV Usage... I D F WARRANTY Compressor - Limited warranty for five years in residential installations and five years in non-residential installations. All other covered components - Five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 20/240. For AHRI Certified system match-ups and expanded ratings, visit www.lennoxpros.com. Sound rated in Lennox reverberant sound test room in Accordance with test conditions included in AHRI Standard 270-2008. Tested in the Lennox Research Laboratory environmental test room. Rated According to U.S. Department of Energy (DOE) test procedures. Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. Units are ETL certified for the U.S. and Canada. ISO 900 Registered Manufacturing Quality System. Energy Star certified units are designed to use less energy, help save money on utility bills, and help protect the environment. Many Lennox home comfort systems meet Energy Star requirements when used with matching components. E APPLICATIONS.5 through 5 tons. Sound levels as low as 76 db. Single phase power supply. Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Designed for applications with remotely located indoor air handler units or gas furnaces with indoor add-on coils. When heat pumps are used with gas furnaces, a dual-fuel compatible thermostat or a zone control system with dual-fuel capabilities must be used (order separately). See Indoor Coils and Air Handlers sections for indoor unit data. Units shipped completely factory assembled, piped and wired. Each unit is test operated at the factory insuring proper operation. Installer must set outdoor unit, connect refrigerant lines and make electrical connections to complete job. 4HPX -.5 to 5 Ton Heat Pump / Page 2

B C D FEATURES REFRIGERATION SYSTEM R-40A Refrigerant Non-chlorine, ozone friendly, R-40A. Unit is factory pre-charged with refrigerant. Total system refrigerant charge is dependant on outdoor unit size, indoor unit size and refrigerant line length. Refer to the unit-mounted charging sticker to determine correct amount of charge required. Coil Fan Direct drive fan moves large air volumes uniformly through entire outdoor coil for high refrigerant cooling and heating capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has ball bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Louvered steel top fan guard furnished as standard. Fan service access accomplished by removal of top panel. Copper Tube/Enhanced Fin Coil Lennox designed and fabricated coil. Ripple-edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections/silver soldering construction. Coil is factory tested under high pressure to ensure leakproof construction. Steel louvered panels provide complete coil protection. Panels can be completely removed for servicing. Expansion Valve - Unit Designed and sized specifically for use in heat pump system. Sensing bulb is located on the suction line between the reversing valve and the compressor to sense evaporator suction temperature in the heat cycle. E F High Capacity Liquid Line Drier Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 00% molecular-sieve, bead type bi-flow drier. Reversing Valve 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. Valve operates on pressure differential between outdoor unit and indoor unit of the system. Factory installed. Optional Accessories Check/Expansion Valve Kits Must be ordered extra and field installed on certain indoor units. See TXV Usage table. Chatleff-style fitting. Loss of Charge Kit Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally-closed switch, automatic reset switch. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. High Pressure Switch Protects the system from high pressure conditions that can be a result of fan failure or a blocked/dirty coil. Automatic reset. Low Pressure Switch Shuts off unit if suction pressure falls below setting. Provides loss of charge and freeze-up protection. Automatic reset. 4HPX -.5 to 5 Ton Heat Pump / Page 3

G FEATURES COMPRESSOR Scroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Muffler in discharge line reduces operating sound levels. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Compressor Crankcase Heater (Factory installed on -036-042-048-060 models) Protects against refrigerant migration that can occur during low ambient operation. Optional Accessories Compressor Crankcase Heater (Optional for -08-024-030 models) Protects against refrigerant migration that can occur during low ambient operation. Compressor Sound Cover A reinforced vinyl compressor cover containing a -/2 inch thick batt of fiberglass insulation. All open edges are sealed with a one-inch wide hook and loop fastening tape. 4HPX -.5 to 5 Ton Heat Pump / Page 4

H FEATURES CONTROLS Defrost Control Time/temperature defrost control is furnished as standard equipment. Control initiates a defrost cycle every 30, 60 or 90 minutes of compressor on time at outdoor coil temperatures below 42 F. Factory setting is 90 minutes. Anti-short cycle, timed-off control (5 minutes). Compressor delay (30 seconds, field selectable) for cycling the compressor in and out of the defrost mode. High and low pressure switch monitoring with five-trip lockout. Two diagnostic LEDs furnished as an aid in troubleshooting. Conveniently located in control box. Optional Accessories icomfort M30 Smart Wi-Fi Thermostat Wi-Fi-enabled, electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/2 Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy to read 4.3 in. color touchscreen (measured diagonally). LCD display with backlight shows the current and set temperature, time, inside relative humidity, system status (operating mode and schedules) and outside temperature (optional outdoor sensor required). Smooth Setback Recovery starts system early to achieve setpoint at start of program period. Compressor short-cycle protection (5 minutes). Up to four separate schedules are available plus Schedule IQ. One-Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away. Smart Away - Uses geo-fencing technology to determine when the homeowner is within a predetermined distance from the home to operate the system when leaving, away and arriving. Amazon Alexa-enabled, smart-home-compatible. It works with Amazon Echo, Echo Dot and Tap devices. Wi-Fi remote monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. See the icomfort M30 Smart Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. Remote Temperature Sensor Used with the icomfort M30 Smart Thermostat. When installed outdoors, sensor allows thermostat to display outdoor temperature. Sensor is auto-detected when connected to thermostat. NOTE - Sensor is required for the Enhanced Dehumidification Accessory (EDA). Thermostat Thermostat (programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally doesn t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Low Ambient Cut-Off Non-adjustable switch (low ambient cut-out) prevents compressor operation in cooling mode, when outdoor temperature is below 35 F. Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it s setpoint. Opens at 29 F and closes at 58 F. Indoor Blower Off Delay Relay Kit Delays the indoor blower-off time during the cooling cycle. See AHRI System Matches for usage. Low Ambient Kit Heat pump units will operate satisfactorily in the cooling mode down to 45 F outdoor air temperature without any additional controls. Kit can be added in the field enabling unit to operate properly down to 30 F in the cooling mode. Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit. A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions. 4HPX -.5 to 5 Ton Heat Pump / Page 5

FEATURES CONTROLS (continued) Optional Accessories (continued) Low Pressure Switch Bypass Thermostat For use in applications where the heat pump is operated in outdoor ambient temperatures below 5 F. Prevents nuisance trips from the low pressure switch. Wired in parallel with the low pressure switch. Mild Weather Kit Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75 F. Mild Weather Kit can be field installed, allowing heating operation above 75 F. Monitor Kit - Service Light Contains ambient compensating thermistor and service light thermostat. For use with thermostats requiring input for indicator lights. Refrigerant Line Connections, Electrical Inlets, Service Valves Sweat connection vapor and liquid lines are located on corner of unit cabinet. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Vapor valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing. Optional Accessories Unit Stand-Off Kit Black high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture. Four feet are furnished per order number. I Thermostat Kit An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where two stage control is applicable. thermostat maintains the heating load on the low power input as long as possible before allowing the full power load to come on the line. Thermostat kit and mounting box must be ordered separately. CABINET Heavy gauge steel cabinet with five station metal wash process. Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil. Powder paint finish provides superior rust and corrosion protection. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. PermaGuard Unit Base Durable zinc-coated base section resists rust and corrosion. 4HPX -.5 to 5 Ton Heat Pump / Page 6

SPECIFICATIONS General Model No. 4HPX-08 4HPX-024 4HPX-030 4HPX-036 Data Nominal Tonnage.5 2 2.5 3 Sound Rating Number 76 76 76 79 Connections Liquid line o.d. - in. 3/8 3/8 3/8 3/8 (sweat) Vapor line o.d. - in. 3/4 3/4 3/4 7/8 2 Refrigerant R-40A charge furnished 5 lbs. oz. 5 lbs. 4 oz. 5 lbs. 0 oz. 9 lbs. 6 oz. Coil Fan Net face area - sq. ft. Outer coil 2.00 2.00 2.00 8.67 Inner coil - - - - - - - - - 8.0 Tube diameter - in. 5/6 5/6 5/6 5/6 No. of rows 2 Fins per inch 22 22 22 22 Diameter - in. 22 22 22 22 No. of Blades 3 3 3 3 Motor hp /6 /6 /6 /6 Cfm 2670 2670 2890 2870 Rpm 867 867 847 839 Watts 68 77 200 205 Shipping Data - lbs. package 77 77 77 202 ELECTRICAL DATA Line voltage data - 60 hz - ph 208/230V 208/230V 208/230V 208/230V 3 Maximum overcurrent protection (amps) 20 30 25 30 4 Minimum circuit ampacity 2.2 7.9 7. 8.7 Compressor Rated Load Amps 8.96 3.5 2.8 4. Locked Rotor Amps 48 58 64 77 Power Factor 0.98 0.98 0.98 0.99 Fan Motor Full Load Amps.0... Locked Rotor Amps.9.9.9.9 CONTROLS icomfort M30 Smart Wi-Fi Thermostat 5Z69 Remote Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater 93M04 Factory Compressor Hard Copeland 0J42 Start Kit LG 88M9 Compressor Low Ambient Cut-Off 45F08 Compressor Sound Cover 69J03 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M8 Loss of Charge Kit 84M23 5 Low Ambient Kit 54M89 Low Pressure Switch Bypass Thermostat 3W07 Mild Weather Kit 33M07 Monitor Kit - Service Light 76F53 Thermostat 56A87 Thermostat Kit Mounting Box 346 Refrigerant Line L5-4-20 L5-4-40 Sets L5-4-30 L5-4-50 L5-65-30 L5-65-40 L5-65-50 Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 0% and minus 5% of line voltage. Sound Rating Number rated in accordance with test conditions included in AHRI Standard 270. 2 Refrigerant charge sufficient for 5 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and additional refrigerant charge required. 3 HACR type circuit breaker or fuse. 4 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 5 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 4HPX -.5 to 5 Ton Heat Pump / Page 7

SPECIFICATIONS General Model No. 4HPX-042 4HPX-048 4HPX-060 Data Nominal Tonnage 3.5 4 5 Sound Rating Number 79 80 80 Connections Liquid line o.d. - in. 3/8 3/8 3/8 (sweat) Vapor line o.d. - in. 7/8 7/8 7/8 2 Refrigerant R-40A charge furnished lbs. 4 oz. 0 lbs. 7 oz. 2 lbs. oz. Coil Fan Net face area - sq. ft. Outer coil 24.93 24.93 29.09 Inner coil 24.3 24.3 28.6 Tube diameter - in. 5/6 5/6 5/6 No. of rows 2 2 2 Fins per inch 22 22 22 Diameter - in. 22 22 22 No. of Blades 4 4 4 Motor hp /3 /3 /3 Cfm 4347 4347 4500 Rpm 843 843 830 Watts 299 299 307 Shipping Data - lbs. package 272 273 295 ELECTRICAL DATA Line voltage data - 60 hz - ph 208/230V 208/230V 208/230V 3 Maximum overcurrent protection (amps) 40 50 50 4 Minimum circuit ampacity 24.2 29.0 29.4 Compressor Rated Load Amps 7.92 2.76 22.0 Locked Rotor Amps 2 7 25 Power Factor 0.99 0.99 0.99 Fan Motor Full Load Amps.8.8.8 Locked Rotor Amps 2.9 2.9 2.9 CONTROLS icomfort M30 Smart Wi-Fi Thermostat 5Z69 Remote Temperature Sensor X2658 OPTIONAL ACCESSORIES - ORDER SEPARATELY Compressor Crankcase Heater Factory Compressor Hard Start Kit Copeland 0J42 LG 88M9 Compressor Low Ambient Cut-Off 45F08 Compressor Sound Cover 69J03 Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 Indoor Blower Off Delay Relay 58M8 Loss of Charge Kit 84M23 5 Low Ambient Kit 54M89 Low Pressure Switch Bypass Thermostat 3W07 Mild Weather Kit 33M07 Monitor Kit - Service Light 76F53 Thermostat 56A87 Thermostat Kit Mounting Box 346 Refrigerant Line L5-65-30 L5-65-40 Sets L5-65-50 Unit Stand-Off Kit 94J45 NOTE - Extremes of operating range are plus 0% and minus 5% of line voltage. Sound Rating Number rated in accordance with test conditions included in AHRI Standard 270. 2 Refrigerant charge sufficient for 5 ft. length of refrigerant lines. 3 HACR type circuit breaker or fuse. 4 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. 5 Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 4HPX -.5 to 5 Ton Heat Pump / Page 8

DIMENSIONS INLET AIR 4-3/8 4-3/8 () () 4-3/8 4-3/8 () () INLET INLET OPTIONAL UNIT STAND-OFF KIT (4) (Field Installed) COMPRESSOR AIR AIR COIL DRAIN OUTLETS (Around perimeter of base) SUCTION LINE CONNECTION 6-3/8 (62) 4-3/8 () INLET AIR TOP VIEW LIQUID LINE CONNECTION 6-3/8 (62) 4-3/8 () TOP VIEW BASE SECTION A OUTDOOR COIL FAN A DISCHARGE AIR COMPRESSOR C B ELECTRICAL INLETS SUCTION AND LIQUID LINE CONNECTION 2-3/4 (70) 2 (5) SIDE VIEW 3/4 (9) OPTIONAL UNIT STANDOFF KIT (4) (FIELD INSTALLED) SIDE VIEW Model No. A B C inches mm inches mm inches mm 4HPX-08-230 28-/4 78 37-/4 946 36-/2 927 4HPX-024-230 28-/4 78 37-/4 946 36-/2 927 4HPX-030-230 28-/4 78 37-/4 946 36-/2 927 4HPX-036-230 28-/4 78 33-/4 845 32-/2 826 4HPX-042-230 32-/4 89 37-/4 946 36-/2 927 4HPX-048-230 32-/4 89 37-/4 946 36-/2 927 4HPX-060-230 32-/4 89 43-/4 099 42-/4 073 4HPX -.5 to 5 Ton Heat Pump / Page 9

SOUND DATA Unit Model Octave Band Linear Sound Power Levels db, re 0-2 Watts Center Frequency - HZ Sound Rating Number (db) ² Estimated Sound Pressure Level at Distance From Unit (db at distance in ft.) 25 250 500 000 2000 4000 8000 3 5 0 5 50 08 72 70.5 68.5 68 65 59.5 53.5 76 69 64 58 55 44 024 7 74.5 72.5 7.5 68 62.5 56.5 76 69 64 58 55 44 030 70.5 70.5 7.5 7.5 66 62.5 59 76 69 64 58 55 44 036 78.5 77 77.5 74.5 69.5 63.5 6.5 79 72 67 6 58 47 042 76.5 78 78.5 73.5 69.5 63.5 58.5 79 72 67 6 58 47 048 75.5 78 78.5 75 70 63.5 58.5 80 73 68 62 59 48 060 75 77.5 77.5 75.5 70 65 65 80 73 68 62 59 48 NOTE - the octave sound power data does not include tonal correction. Tested according to AHRI Standard 270-2008 test conditions. 2 Estimated sound pressure level at distance based on AHRI Standard 275-200 method for equipment located on the ground, roof, or on side of building wall with no adjacent reflective surface within 9.8 feet. Sound pressure levels will increase based on changes to assumptions. For other applications, refer to AHRI Standard 275. FIELD WIRING INSTALLATION CLEARANCES A DISCONNECT SWITCH (By Others) OPTIONAL OUTDOOR THERMOSTAT LENNOX OUTDOOR UNIT D OPTIONAL ELECTRIC HEAT LENNOX INDOOR UNIT B DISCONNECT SWITCH (By Others) THERMOSTAT (Optional) C See NOTES See NOTES See NOTES See NOTES CONTROL BOX A - Two Wire Power (see Electrical Data) B - Two or Three Wire Power (size to heater capacity) C - Twelve Wire Low Voltage 8 ga. minimum Fourteen Wire Low Voltage with Optional Thermostat D - Eight Wire Low Voltage 8 ga. minimum Ten Wire Low Voltage with Optional Thermostat NOTE - Field Wiring Not Furnished All wiring must conform to NEC or CEC and local electrical codes. NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (94 mm) Clearance to one of the remaining two sides may be 2 in. (305 mm) and the final side may be 6 in. (52 mm). A clearance of 24 in. must be maintained between two units. 48 in. (29 mm) clearance required on top of unit. 4HPX -.5 to 5 Ton Heat Pump / Page 0

TXV USAGE Use this table for C33, CH23, CH33 and CR33 Field Installed TXV Match-Ups. Model No. Order No. 4HPX-08 2J8 4HPX-024 2J8 4HPX-030 2J8 4HPX-036 2J9 4HPX-042 2J20 4HPX-048 2J20 4HPX-060 2J20 CX34 and CX38 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed. C33 and CH33 coils - Replace the factory installed orifice with the expansion valve listed. CR33 and CH23 - Use the expansion valve listed. *TXV SUBSTITUTIONS Use this table to determine if the factory installed TXV in the indoor unit needs to be replaced. Model No. Indoor Coil Factory TXV Replacement TXV 4HPX-030 CX34-44/48 2J20 2J8 4HPX-030 CX38-44/48 2J20 2J8 * CX34 and CX38 coils - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used. MOST POPULAR MATCHES Unit Model No. 4HPX-08 4HPX-024 4HPX-030 4HPX-036 4HPX-042 4HPX-048 4HPX-060 Indoor Unit Model No CBX25UH-08 CBX25UH-024 CBX25UH-030 CBX25UH-036 CBX25UH-042 CBX25UH-048 CBX25UH-060 AHRI STANDARD 20/240 Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation. Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 250 Btu/h per,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per,000 cfm of indoor air circulated. 4HPX -.5 to 5 Ton Heat Pump / Page

REVISIONS Sections Optional Accessories Added icomfort M30 Smart Thermostat. Description of Change Visit us at www.lennox.com For the latest technical information, www.lennoxpros.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 209 Lennox Industries, Inc.