Contents Nomenclature... 2 Accessories... 2... 3 Dimensions... 4 Airflow Data... 5 Heat Kit Data... 6 Wiring Diagram... 8 Series Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Direct drive, multi-speed PSC blower motor All-aluminum evaporator coil Coil mounting track for quick repositioning Optimized for use with R-40A refrigerant Cabinet air leakage less than 2.0% at.0 inch H2O when tested in accordance with ASHRAE standard 93 Cabinet air leakage less than.4% at 0.5 inch H2O when tested in accordance with ASHRAE standard 93 3 kw 25 kw electric heater kits Horizontal or vertical configuration capabilities Rigid SmartFrame cabinet 2 depth for easier attic access DecaBDE-free thermoplastic drain pan with secondary drain connections Screw-less sides and back helps to reduce condensation when installed in humid locations Foil-faced insulation covers the internal casing to reduce cabinet condensation Galvanized, leather grain-embossed finish Glue-less cabinet insulation retention Tool-less filter access AHRI certified; ETL listed Multi-Position Internal TXV, Multi-Speed PSC Motor Air Handler ½ to 5 Tons * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 0-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-G www.goodmanmfg.com 4/4 Supersedes 3/3
Nomenclature A R P T 24 C 4 AA 2 3 4 5,6 7 8 9 0, Brand Engineering * A - Single- Piece Air Handler Major/ Minor Revisions Unit Application C - Ceiling Mount PSC Motor R - Multi- Position PSC Motor S - Multi- Position EEM Motor W - Wall Mount PSC Motor Cabinet Finish U - Unpainted P - Painted N - Uncased *Not used for inventory management Refrigerant Compatability 4 = R- 40A Electrical - 208/230 V, Phase, 60 Hz Nominal Width B - 7½ Wide C - 2 Wide D - 24½ Wide Expansion Device F - Flowrater Nominal Capacity Range T - Expansion Valve 8 = ½ Tons 42 = 3½ Tons 24 = 2 Tons 48 = 4 Tons 30 = 2½ Tons 60 = 5 Tons 36 = 3 Tons Accessories Downflow Insulation Kit DPI-B DPI-C DPI-D 8B4** 36C4** 36D4** 24B4** 30B4** 42D4** 48D4** 60D4** Filters Chassis Part # Size B ALFH620E 6.0 x 20.0 C ALFH9220E 9.5 x 20.0 D ALFH2023E 23.0 x 20.0 2 www.goodmanmfg.com SS-G
Specifications 8B4* 24B4* 30B4* 36C4* 36D4* 42D4* 48D4* 60D4* Nominal Ratings Cooling (Btu/h) 8,000 24,000 30,000 36,000 36,000 42,000 48,000 60000 Blower Diameter 9½" 9½" 9½" 0⅝" 0⅝" 0⅝" 5 / 6 " 5 / 6 " Width 6" 6" 6" 8" 0⅝" 0⅝" 0⅝" 0⅝" Coil Drain Connect FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Refrigerant Line Connection Size Liquid 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" 3/8" Suction 3/4" 3/4" 3/4" 7/8" 7/8" 7/8" 7/8" 7/8" Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Min Circuit Ampacity 3/3 3/3 3/3 5/5 5/5 6/6 Max. Overcurrent Device (amps) Min. / Max VAC 97/ 253 97/ 253 97/ 253 97/253 97/ 253 97/ 253 97/ 253 97/ 253 Blower Motor A/ HP.9/ ⅓.9/ ⅓.9/ ⅓ 3./ ⅓ 3.0/ ½ 3.5/ ½ 3.5/ ½ 4.6/ ¾ Ship Weight (lbs) 99 99 0 30 30 47 57 59 SS-G www.goodmanmfg.com 3
Dimensions 3.08" (7.82 cm).63" (4.3 cm).45" (3.68 cm) 2" 4.50" (.43 cm) 2.9" (7.39 cm) 2.93" (7.44 cm) 7.5" (9. cm) 5.2" (3.3 cm) 9.2" DRAIN PORT DETAIL.55" (.40 cm) C B.55" (.40 cm) 3." (7.9 cm).4" (3.6 cm).3" (28.70 cm).55" (.40 cm) PLASTIC EAKER COVER.8" (4.6 cm) LOGO LOCATION 2.7" (5.5cm) SUCTION TUBE LIQUID LINE A G INLET TUBE SEE DRAIN PORT DETAIL H E D.73" (4.39 cm) F INLET (FRONT VIEW).73" (4.39 cm) " (2.54 cm) 9.5" (49.5 cm) INLET (RIGHT SIDE VIEW).55" (.40 cm) Model A" B" C" D" E" F" G" H" 8B4* 45 6⅜ 7½ 8 5 4³ ₁₆ 8¹³ ₁₆ ¹⁵ ₁₆ 24B4* 45 6⅜ 7½ 8 5 4³ ₁₆ 8¹³ ₁₆ ¹⁵ ₁₆ 30B4* 45 6⅜ 7½ 8 5 4³ ₁₆ 8¹³ ₁₆ ¹⁵ ₁₆ 36C4* 49 9¹⁵ ₁₆ 2 20 7 7¹¹ ₁₆ 0½ 2⅜ 36D4* 58 23⁵ ₁₆ 24½ 28³ ₁₆ 25³ ₁₆ 2³ ₁₆ 2⁵ ₁₆ 2⅜ 42D4* 58 23⁵ ₁₆ 24½ 28³ ₁₆ 25³ ₁₆ 2³ ₁₆ 2⁵ ₁₆ 2⅜ 48D4* 58 23⁵ ₁₆ 24½ 28³ ₁₆ 25³ ₁₆ 2³ ₁₆ 2⁵ ₁₆ 2⅜ 60D4* 58 23⁵ ₁₆ 24½ 28³ ₁₆ 25³ ₁₆ 2³ ₁₆ 2⁵ ₁₆ 2⅜ 4 www.goodmanmfg.com SS-G
Airflow Data Model 8B4 24B4 30B4 36C4 36D4 42D4 48D4 60D4 Blower Speed Static Pressure (in w.c) Airflow (CFM) 0. 0.2 0.3 0.4 0.5 0.6 0.7 High,85,25,065,00 985 90 780 Medium 900 850 825 785 75 670 60 Low 630 605 560 525 495 445 355 High,85,25,065,00 985 90 780 Medium 900 850 825 785 75 670 60 Low 630 605 560 525 495 445 355 High,45,085,020 950 900 845 765 Medium 870 820 775 745 705 655 580 Low 65 585 565 535 490 435 345 High,580,55,445,395,345,240,55 Medium,385,350,300,250,70,095,005 Low,260,205,75,05,040 975 865 High,85,770,705,640,555,450,355 Medium,580,525,485,420,350,275,65 Low,220,80,40,085,030 950 865 High,990,95,80,765,690,585,435 Medium,655,605,555,480,295,200,060 Low,480,420,350,290,85,00,045 High,960,905,845,780,75,645,570 Medium,600,545,495,435,360,290,25 Low,395,340,280,220,50,090,020 High 2,205 2,40 2,080 2,00,945,870,795 Medium,985,935,865,85,755,695,635 Low,600,555,505,455,405,345,295 Notes. Airflow data indicated is at 230V without air filter in place. 2. The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. The shaded area indicates ranges in excess of maximum recommended design external static pressure. 3. Use the CFM adjustment factors of 0.98 for horizontal left and 0.96 for horizontal right & downflow orientations SS-G www.goodmanmfg.com 5
6 www.goodmanmfg.com SS-G Heat Kit Data Models Circuit Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² 8B4AC 2.4/2.4 6/8 24/27 29/34 38/44 25/30 30/35 24B4AC 2.4/2.4 6/8 24/27 30/34 39/44 25/30 30/35 67/77 30B4AC 2.4/2.4 6/8 24/27 30/34 39/44 25/30 30/35 67/77 36C4AC HKSC9C#* 7/20 26/29 32/36 40/46 30/30 43/50 69/79 9/04
Heat Kit Data (cont.) Models Circuit Circuit 2 Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² 36D4AC HKSC20D#* 42D4AC HKSC20D#* 48D4AC HKSC20D#* 60D4AC HKSC20D#* HKSC25DC* 52/60 7/9 25/29 3/35 8/20 26/29 3/36 40/46 8/20 26/29 3/36 40/46 6/6 9/2 27/3 33/37 42/47 49/56 49/56 49/56 6/6 6/6 7/8 30/30 35/35 40/50 30/30 30/30 20/25 30/35 80/90 44/50 44/50 43/50 43/50 43/50 25/30 45/60 69/79 90/04 69/79 9/04 69/79 9/04 7/8 92/06 4/3 80/90 25/50 ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X.25 ² Maximum Overcurrent Protection = 2.25 X Motor Amps + Heater Amps * Revision level that may or may not be designated indicates Not Required SS-G www.goodmanmfg.com 7
Wiring Diagram HTR TL M R M2 2 3 4 5 6 7 8 9 HTR2 TL HTR TL M M3 R M2 M4 2 3 4 5 6 7 8 9 HTR TL HTR2 TL HTR3 TL YL YL M M3 M M2 M4 M2 R R2 YL 2 3 4 5 6 7 8 9 HTR TL HTR2 TL HTR3 TL YL HTR4 TL 2 3 M M3 M5 M7 YL 4 M2 M4 M6 M8 R R2 5 6 7 YL 8 9 L L2 L L2 L L2 L L2 ONE () ELEMENT ROWS TWO (2) ELEMENT ROWS THREE (3) ELEMENT ROWS FOUR (4) ELEMENT ROWS L L2 L L2 NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP IS NOT BELOW MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIR HANDLER/HEATER KIT COMBINATION ON THIS UNITS SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK A "X" IN THE PROVIDED ABOVE. MARK ACCOING TO THE NUMBER OF HEATER ELEMENT ROWS INSTALLED. NO MARK INDICATES NO HEAT KIT INSTALLED. 5 ELEMENT ROWS DATA SUPPLIED WITH HEATER KIT. SEE NOTE 2 TERMINAL OCK SHOWN FOR 50HZ MODELS ONLY L L2 EQUIPMENT GROUND USE COPPER WIRE 208/240 VOLTS GR SR 2 3 G 4 5 6 7 8 9 L L2 2 PLM 2 3 4 5 6 7 8 9 PLM 3 PLM 2 SEE NOTE 4 RC EM HI LO M M2 NC NO EBTDR COM 2 3 SEE NOTE TR GR SPEEDUP COPPER POWER SUPPLY (SEE RATING PLATE) USE MIN. 75 C FIELD WIRE G EBTDR R K XFMR-R XFMR-C C K M IF REPLACEMENT OF THE ORIGINAL WIRES SUPPLIED WITH THIS ASSEMY IS NECESSARY USE WIRE THAT CONFORMS TO THE NATIONAL ELECTRIC CODE. SEE NOTE 5 NO COM NC M2 SEE NOTE 3 THREE SPEED MOTOR WIRING (SELECT MODELS ONLY) SEE NOTE 3 (M2) (M) (TR ) RC (COM) LOW MEDIUM HIGH C 2 3 5 EM 3 SPEED 24V 4 SEE NOTE 240 TR RC EM NOTES: EBTDR R EM RC SR R EBTDR COLOR CODE YL ACK RED YELLOW GR GREEN RPLE OWN UE ITE COMPONENT CODE 4 24V 5 6 5 4 EVAPORATOR MOTOR RUN CAPACITOR STRAIN RELIEF RELAY ELECTRONIC OWER TIME DELAY RELAY FACTORY WIRING HIGH VOLTAGE LOW VOLTAGE FIELD WIRING HIGH VOLTAGE LOW VOLTAGE TR PLM TL HTR EBTDR WIRING CODE TRANSFORMER FEMALE PLUG CONNECTOR MALE PLUG CONNECTOR FUSE LINK THERMAL LIMIT HEAT ELEMENTS ) RED WIRES TO BE ON TRANSFORMER TERMINAL "3" FOR 240 VOLTS AND ON TERMINAL "2" FOR 208 VOLTS. 2) SEE COMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUCTIONS FOR PROPER LOW VOLTAGE WIRING CONNECTIONS. 3) CONFIRM SPEED TAP SELECTED IS APPROPRIATE FOR APPLICATION. IF SPEED TAP NEEDS TO BE CHANGED, CONNECT APPROPRIATE MOTOR WIRE (RED FOR LOW, UE FOR MEDIUM,AND ACK FOR HIGH SPEED) ON "COM" CONNECTION OF THE EBTDR. INACTIVE MOTOR WIRES SHOULD BE CONNECTED TO "M OR M2" ON EBTDR. 4) OWN AND ITE WIRES ARE USED WITH HEAT KITS ONLY. 5) EBTDR HAS A 7 SECOND ON DELAY EN "G" IS ENERGIZED AND A 65 SECOND OFF DELAY EN "G" IS DE-ENERGIZED. 040A00058-B C G GR NOTE: The five element, 25 kw heater kit is not shown above. Wiring is subject to change. Always refer to the wiring diagram or the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 204 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. 8 www.goodmanmfg.com SS-G