AVPTC Multi-Position, Internal Txv

Similar documents
AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

AVPTC Multi-Position, Internal Txv

AVPTC Multi-Position, Internal Txv

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

AVPTC. Air Handler 1½ to 5 Tons

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

AVPTC. Air Handlers 1½ to 5 Tons

MBR. Multi-Position. Modular Blower

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers

ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

PRODUCT SPECIFICATIONS

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Bosch BVA Series Air Handler

VERTICAL MOUNT AIR HANDLERS

ComfortNet -Compatible

TECHNICAL SPECIFICATIONS

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

WAHL A Product Specifications

FEM4X. Product Specifications FAN COILS /14/15

157 (71) 3-1/ (661) 49 5/8 x 21 1/8 x 22 1/16 (1261 x 537 x 560) 19 7/8 x 21 1/2 (505 x 546) FSM4P4200AL 156 (71) FEM4P4800AL

MERIT Series R-410A - Upflow / Horizontal

MBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

TECHNICAL SPECIFICATIONS

REM4P, REM4X. Product Specifications

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

Bosch BVA Series Air Handler

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

13 GEP A L P - 1 A

RGE 13 A T - 1 A

49 x 21 x 22. (1261 x 448 x 560) (1261 x 448 x 560) 59 x 24 x 22. (1357 x 537 x 560) (1261 x 537 x 560) (1261 x 537 x 560) (1357 x 627 x 560)

AR SERIES COMMERCIAL AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

INSTALLATION INSTRUCTION

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

MERIT Series R-410A - Upflow / Horizontal

AIR HANDLERS AIR HANDLERS

49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 49 5/8 x 17 5/8 x 22 1/16 (1261 x 448 x 560) 53 7/16 x 21 1/8 x 22 1/16 (1357 x 537 x 560)

GKS9 40" 90% Gas Furnaces

REPAIR PARTS. HKR / HKA/ HKP Heater Kits

TECHNICAL MANUAL. GMH8 39" 80% Gas Furnace 80% AFUE, 2-Stage (Convertible), Multi-Speed, Upflow/Horizontal

TECHNICAL SPECIFICATIONS B6VMMX

Product Data PF4MNB DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 019 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Product Data. Convertible Air Handlers 1 1/2 5Ton

Dimensions H x W x D in. (mm)

Wiring Diagrams Units Produced After April 20, 2009

FXM4X. Product Specifications FAN COILS FXM4X

Product Data PF4MNA DIRECT EXPANSION FAN COIL FOR R -410A REFRIGERANT SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES:

Variable Speed Convertible Air Handler 5 Ton

MBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

TECHNICAL MANUAL. AMS8 33-3/8" Gas Furnace Units 80% AFUE, Single Stage, Multi-Speed, Upflow Horizontal

MBVC INTRODUCTION CHECKING PRODUCT RECEIVED BLOWER CABINET INSTALLATION INSTRUCTIONS NOTICE IF A 1 FLASH ERROR CODE OR AN EC HTR TOO LARGE ERROR IS

AVPTC**14** AIR HANDLERS INSTALLATION & OPERATING INSTRUCTIONS

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

HIGH EFFICIENCY AIR HANDLER

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

MX Series Indoor Modular Blowers Electric Heat, Hot Water Heat, or No Heat

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

Wiring Diagrams. 38ARZ ARS ARD Air-Cooled Condensing Units 50/60 Hz

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

Installation Instructions

HIGH EFFICIENCY AIR HANDLER

Wiring Diagrams DIAGRAM INDEX

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

PRODUCT SPECIFICATIONS

Fan Coils & Air Handlers Product Catalog

Split System Cooling Product Data

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

Transcription:

Multi-Position, Internal Txv Variable-Speed ECM Based Comfortnet Compatible Air Handler 1½ to 5 Tons Contents Air Handler Nomenclature... Heater Kit Nomenclature......3 Dimensions...4 Airflow Data...5 Heat Kit Data... 7 Wiring Diagram...9 Accessories... 11 Product Features Internal factory-installed thermal expansion valves for cooling and heat pump applications Variable-speed ECM blower motor ComfortNet Communicating System compatible Auto configuration of the airflow and tonnage in communicating mode Provides constant CFM over a wide range of static pressure conditions independent of duct system CFM indicator Fault recall of six most recent faults Provides adjustable low CFM for efficient fan-only operation Improved humidity and comfort control Built-in compatibility with multi-stage heat pump and cooling applications All-aluminum evaporator coil Cabinet air leakage less than.0% at 1.0 inch HO when tested in accordance with ASHRAE standard 193 Cabinet air leakage less than 1.4% at 0.5 inch HO when tested in accordance with ASHRAE standard 193 3 kw 5 kw electric heater kits Horizontal or vertical configuration capabilities Rigid SmartFrame cabinet 1" depth for easier attic access DecaBDE-free thermoplastic drain pan with secondary drain connections Screw-less sides and back helps to reduce condensation when installed in humid locations Foil-faced insulation covers the internal casing to reduce cabinet condensation Galvanized, leather grain-embossed finish Glue-less cabinet insulation retention Tool-less filter access AHRI certified; ETL listed * Complete warranty details available from your local dealer or at www.goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in California or Quebec. SS-G www.goodmanmfg.com 1/14 Supersedes 7/14

Nomenclature A V P T C 18 B 1 4 AA 1 3 4 5 6,7 8 9 10 11,1 Brand Engineering* A Single- Piece Major/Minor Revisions Airhandler *Not used for inventory management Unit Application Refrigerant Charge R Multi Position PSC Motor 4 = R- 410A S Multi Position EEM Motor V Multi Position Variable- Speed Electrical Motor- Commuminacating 1 08/30V, 1 Phase, 60 Hz Cabinet Finish Cabinet Width U Unpainted B = 17½" P Painted C = 1" D = 4½" Expansion Device F Flowrator Nominal Capacity @ 13SEER T Expansion Device 18 = 1½ Tons 4 = 3½ Tons 4 = Tons 48 = 4 Tons 30 = ½ Tons 60 = 5 Tons Communications 36 = 3 Tons C = ComfortNet TM Compatible HKS X 03 X A AA Unit Type Major & Minor Revisions HKS - AH Heater Kit Phase Circuit Breaker A - - 08 VAC / 1 Ø D - - 08 VAC / 3 Ø X - - No circuit breaker B - - 40 VAC / 1 Ø E - - 40 VAC / 3 Ø C - - Circuit Breaker C - - 08/40 VAC / 1 Ø F - - 08/40 VAC / 3 Ø G - - 460 VAC / 3 Ø kw 03 - - 3.0 kw 15 - - 14.4 kw Cabinet Size (MAX) 05 - - 4.8 kw 19 - - 19.kW w/150f limit C - - C Cabinet 06 - - 6.0kW 0 - - 19.kW w/170f limit D - - D Cabinet 08 - - 8.0kW 5 - - 5.0 kw X - - All Cabinet Sizes 10 - - 9.6 kw Heating kw Correction Factor Supply Voltage 40 30 0 10 08 Correction Factor 1.00 0.9 0.84 0.77 0.75 Multiply the 40-volt heating capacity by correction factors. www.goodmanmfg.com SS-G

Specifications Nominal Ratings 4B14A* 30C14A* 36C14A* 4C14A* 48C14A* 48D14A* 60D14A* Cooling (BTU/h) 4,000 30,000 36,000 4,000 48,000 48,000 60,000 Blower Diameter 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" 11⅝" Width 6" 8" 10⅝" 10⅝" 10⅝" 10⅝" 10⅝" Coil Connections Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ⅞" ⅞" ⅞" ⅞" ⅞" ⅞" Coil Drain Connection (FPT) ¾" ¾" ¾" ¾" ¾" ¾" ¾" Electrical Data Voltage 08/30 08/30 08/30 08/30 08/30 08/30 08/30 Min Circuit Ampacity 4.9/4.9 4.9/4.9 8.6/8.6 Max. Overcurrent Device (Amps) Minimum VAC 197 197 197 197 197 197 197 Maximum VAC 53 53 53 53 53 53 53 Blower Motor Full Load Amps (FLA) 3.9 3.9 5. 5. 5. 5. 6.9 Horsepower (HP) ½ ½ ¾ ¾ ¾ ¾ 1 Ship Weight (Lbs.) 100 118 118 155 15 167 167 Note: Minimum Circuit Ampacity (MCA) and Maximum Overcurrent Protection (MOP) for blower without supplemental heat installed. Refer to unit nameplate and/or Heat Kit Data for specification with approved accessory heaters installed SS-G www.goodmanmfg.com 3

Dimensions 1.63" (4.13 cm) 1.45" (3.68 cm) 3.08" (7.8 cm) 1" 4.50" (11.43 cm).91" (7.39 cm).93" (7.44 cm) 7.5" (19.1 cm) 5." (13.3 cm) 9.1" DRAIN PORT DETAIL.55" (1.40 cm) C B.55" (1.40 cm) 3.1" (7.9 cm) 1.4" (3.6 cm) 11.3" (8.70 cm).55" (1.40 cm) PLASTIC BREAKER COVER 1.8" (4.6 cm) LOGO LOCATION.17" (5.51cm) SUCTION TUBE LIQUID LINE A G INLET TUBE SEE DRAIN PORT DETAIL H E D 1.73" (4.39 cm) F INLET (FRONT VIEW) 1.73" (4.39 cm) 1" (.54 cm) 19.5" (49.5 cm) INLET (RIGHT SIDE VIEW).55" (1.40 cm) Model A B C D E F G H 4B14A* 45 16⅜ 17½ 18 15 14¼ 8⅞ 1 30C14A* 49 0 1 0 17 17¾ 10½ 1⅜ 36C14A* 49 0 1 0 17 17¾ 10½ 1⅜ 4D14A* 58 3⅜ 4½ 8¼ 5¼ 1¼ 1⅜ 1⅜ 48C14A* 49 0 1 0 17 17¾ 10½ 1⅜ 48D14A* 58 3⅜ 4½ 8¼ 5¼ 1¼ 1⅜ 1⅜ 60D14A* 58 3⅜ 4½ 8¼ 5¼ 1¼ 1⅜ 1⅜ 4 www.goodmanmfg.com SS-G

Airflow Data Cooling / Heat Pump Airflow 4B A Low 415 415 410 410 405 405 400 400 400 B Low 575 570 565 560 560 555 555 550 550 C Low 685 670 660 650 645 635 630 65 60 D Low 795 780 765 755 745 735 75 70 715 A High 60 615 610 605 600 600 595 590 590 B High 865 850 835 85 815 805 795 790 785 C High 1005 990 970 960 945 935 90 915 910 D High 1165 1145 115 1110 1100 1085 1070 1065 1055 30C A Low 465 455 440 430 45 415 405 400 395 B Low 615 610 605 600 595 595 590 585 585 C Low 755 745 740 735 730 75 70 70 715 D Low 900 890 885 880 875 870 865 865 860 A High 60 615 610 610 605 605 600 600 600 B High 850 840 835 830 85 80 815 815 810 C High 1030 105 100 1015 1010 1010 1005 1000 1000 D High 145 135 15 10 110 105 100 1195 1195 36C A Low 515 505 500 485 465 460 450 45 410 B Low 715 705 700 685 675 670 660 640 630 C Low 950 935 930 910 895 890 875 855 835 D Low 1135 115 110 1105 1090 1085 1075 1055 1040 A High 740 730 75 710 695 690 680 660 645 B High 1015 1005 1000 985 965 960 950 95 910 C High 1345 1335 1330 1315 1300 195 190 170 155 D High 1615 1605 1600 1585 1570 1565 1555 1535 150 4D A Low 600 580 560 545 535 50 505 500 490 B Low 795 780 765 750 740 730 70 715 710 C Low 105 1010 995 985 970 960 950 945 940 D Low 150 135 15 115 110 100 1195 1190 1185 A High 835 815 800 790 780 765 755 750 745 B High 1115 1105 1090 1080 1070 1065 1055 1050 1045 C High 1445 1430 140 1410 1405 1395 1390 1385 1380 D High 1775 1760 1750 1740 1735 175 170 1715 1710 48C A Low 510 505 500 490 485 480 475 465 455 B Low 710 705 700 690 680 680 670 660 650 C Low 940 935 930 90 910 910 905 890 880 D Low 1165 1160 1160 1155 1150 1145 1140 1135 115 A High 735 730 75 715 705 700 695 685 675 B High 1010 1005 1000 990 985 980 975 965 955 C High 1340 1335 1330 130 1310 1310 1305 190 180 D High 1675 1665 1660 1645 1635 1630 160 1605 1590 SS-G www.goodmanmfg.com 5

Airflow Data (cont.) Cooling / Heat Pump Airflow (cont.) 48D A Low 910 910 900 895 885 880 875 870 850 B Low 1050 1045 1035 1030 105 100 1015 1010 1010 C Low 1155 1145 1140 1135 1130 115 110 110 1115 D Low 115 110 100 1195 1190 1185 1180 1175 1170 A High 1370 1360 1350 1345 1340 1330 135 135 130 B High 1570 1560 1550 1545 1535 1530 155 150 1515 C High 170 1710 1700 1695 1685 1680 1670 1670 1665 D High 1840 180 1800 1785 1775 1760 1745 1740 1735 60D A Low 105 105 110 105 105 100 1195 1195 1195 B Low 1375 1370 1365 1360 1360 1355 1355 1350 1350 C Low 1445 1445 1450 1445 1445 1440 1440 1440 1435 D Low 1535 1530 155 150 150 1515 1510 1510 1510 A High 1615 1615 1610 1610 1605 1605 1600 1600 1600 B High 185 180 1815 1810 1810 1805 1805 1805 1800 C High 1930 195 190 1915 1915 1910 1905 1905 1900 D High 040 030 05 00 015 010 005 005 000 Note: The chart is for information only. For satisfactory operation, external static pressure must not exceed value shown on rating plate. Use the CFM adjustment factors of.98 for horizontal left,.95 for horizontal right &.96 for downflow orientations. Airflow data indicated is at 30V without air filter in place. Electric Heat Airflow HTR kw 9 10 11 4B14A* 30C14A* 36C14A* 4D14A 48C14A* 48D14A 60D14A 3 ON ON ON 730 730 NR 850** NR NR NR 5 ON ON OFF 780 780 850 150 850 150 150 6 ON OFF ON 850 850 900 1300 900 1300 1300 8 ON OFF OFF 950 950 1000 1500 1000 1500 1500 10 OFF ON ON 105 105 100 1550 100 1550 1550 15 OFF ON OFF NR NR 1440 170 1440 170 1780 19* NR NR 1500 NR 1500 NR NR OFF OFF ON 0 NR NR NR 1800 1500 1815 1850 1 or 5* OFF OFF OFF NR NR NR NR NR 1850 1850 Note: Airflow data shown applies to the electric heat only in either legacy mode or communicating mode operation NR - Not Rated * Within thermostat user menu, CTK0* communicating thermostat will display 0kW for OFF- OFF- ON dipswitch selection, 1kW for OFF-OFF-OFF dipswitch selection. For match up with a ton outdoor unit: Heater kit application shall not exceed 10 kw. Airflow for 5 kw up to 10 kw heater kits shall be set to 850 cfm speed tap of ON-ON-ON. For match up with a 3 ton outdoor unit: Heater kit application shall not exceed 15 kw. Airflow for 5 kw up to 15 kw heater kits shall be set to 1300 cfm speed tap of ON-OFF-ON. For match up with a 3.5 ton outdoor unit: Heater kit application shall not exceed 0 kw. Airflow for 5 kw up to 0 kw heater kits shall be set to 1500 cfm speed tap of ON-OFF-OFF ** 3 kw heater kit is not applicable for this indoor application. 6 www.goodmanmfg.com SS-G

Heat Kit Data Models 4B14A* 30C14A* 36C14A* HKSX15XF* HKSX0XF* HKSC15*#* HKSC19C#* HKSC15XF* 48C14AA HKSX15XF* HKSX0XF* HKSC15*#* HKSC19C#* HKSC15XF* 4D14A* HKSX15XF* HKSX0XF* HKSC15*#* HKSC0D#* HKSC15XF* HKSC0XF* Circuit 1 Circuit Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² 4.9/4.9 10.8/1.5 18/1 0/5 7/30 30/30 1.7/5.0 3/36 8.9/33.3 41/47 48/55 10.8/1.5 1.7/5.0 8.9/33.3 10.8/1.5 1.7/5.0 8.9/33.3 10.8/1.5 1.7/5.0 8.9/33.3 10.8/1.5 1.7/5.0 8.9/33.3 4.9/4.9 18/1 7/30 3/36 41/47 48/55 0/ 8/3 34/38 43/48 0/ 8/3 34/38 43/48 0/ 8/3 34/38 43/48 0/5 30/30 0/5 30/35 0/5 30/35 0/5 30/35 All ampacities noted above include air handler motor amps Circuit 1: Single-phase for Air Handlers / Circuit : Three-phase for HKR3 Heater Kits ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.5 ² Maximum Overcurrent Protection =.5 X Motor Amps + Heater Amps * Revision level that may or may not be designated 37.5/43.3 34.7/40 37.5/43.3 34.7/40 37.5/43.3 34.7/40 37.5/43.3 47/54 /5 43/50 47/54 /5 43/50 47/54 /5 43/50 47/54 5/5 5/5 5/5 7/8 93/107 7/8 93/107 7/8 93/107 C = Circuit Breaker Option indicates Not Required HKA meets the new U995 requirements for 15 and 0KW heaters Only applicable when HKA kits are included in table MBVC and MBR models 80/90 100/110 80/90 100/110 80/90 100/110 SS-G www.goodmanmfg.com 7

Heat Kit Data (cont.) Models 48D14A* HKSX15XF* HKSX0XF* HKSC15*#* HKSC0D#* HKSC15XF* HKSC0XF* HKSC5DC* 60D14A* HKSX15XF* HKSX0XF* HKSC15*#* HKSC0D#* HKSC15XF* HKSC0XF* HKSC5DC* Circuit 1 Circuit Single-Point Kit Amps MCA¹ MOP² Amps MCA¹ MOP² MCA¹ MOP² 10.8/1.5 0/ 0/5 8/3 30/35 1.7/5.0 34/38 8.9/33.3 43/48 37.5/43.3 47/54 /5 5/5 7/8 80/90 34.7/40 43/50 93/107 100/110 37.5/43.3 47/54 5.0/60.0 7/8 80/90 43/50 115/13 15/150 10.8/1.5 1.7/5.0 8.9/33.3 5.0/60.0 8.6/8.6 /4 30/34 36/40 5/59 8.6/8.6 8.6/8.6 5/59 5/59 8.6/8.6 8.6/8.6 74/84 5/5 35/35 40/40 45/60 60/60 60/60 60/60 80/90 37.5/43.3 17.3/0 37.5/43.3 47/54 /5 43/50 47/54 43/50 5/5 74/84 95/109 117/134 80/90 100/110 15/150 All ampacities noted above include air handler motor amps Circuit 1: Single-phase for Air Handlers / Circuit : Three-phase for HKR3 Heater Kits ¹ Minimum Circuit Ampacity (Heater Amps + Motor Amps) X 1.5 ² Maximum Overcurrent Protection =.5 X Motor Amps + Heater Amps * Revision level that may or may not be designated C = Circuit Breaker Option indicates Not Required HKA meets the new U995 requirements for 15 and 0KW heaters Only applicable when HKA kits are included in table MBVC and MBR models 8 www.goodmanmfg.com SS-G

Wiring Diagram Air Handler P P 3 3 40 VA TRANSFORMER, SEE NOTE 1 30 VAC 3 08 VAC 4 VAC GRND GN GRND 1 1 6 6 5 5 4 4 7 7 8 8 9 9 SEE NOTE 7 COM 1 BR C W W1 TH TR 4 CIRCUIT HEATER CONNECTOR LEARN COM 4 V 3 A FUSE SEE NOTE 5 FAULT SEE NOTE 6 RECALL CAS SEE NOTE 6 STATUS LED 7 SEGMENT SEE NOTE 8 DIAGNOSTIC DEHUM DISPLAY 4 CFM LED SEE NOTE 6 O 3 RX LED Y Y1 W 1 W1 GY G C R S1 S S3 S4 S5 S6 S7 S8 S9 S10 S11 S1 S13 DIP SWITCHES TWO-STAGE INTEGRATED CONTROL MODULE 1 4 3 4 CIRCUIT MOTOR CONNECTOR AF SELECT ECM MOTOR HARNESS 1 TRIM % COOL AF PROFILE DEHUM ENAE TRIM ENAE HTR KIT(KW) CONT FAN CIRCULATOR OWER 4 3 1 1 3 4 5 GN 4 V THERMOSTAT CONNECTIONS GRND 4V THERMOSTAT CONNECTIONS R W1 W Y1 Y O DISCONNECT DEHUM C FUSE 3 A TO MICRO INDOOR AIR CIRCULATOR WR GRND 08/30 VAC 40 VA TH TRANSFORMER 4 VAC W1 (1) HEAT 1 COIL/R1 W () HEAT COIL/ R CAS (1) CONDENSATE SWITCH CAS () +VDC (1) RX () INDOOR AIR CIRCULATOR WR GRND (4) TR COM INTEGRATED CONTROL MODULE GRND INTEGRATED CONTROL NOTES: 1. PLACE RED WIRES ON TRANSFORMER TERMINAL FOR 08 VAC OPERATION.. MANUFACTURER'S SPECIFIED REPLACEMENT PARTS MUST BE USED EN SERVICING. 3. IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THIS UNIT MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 C. USE COPPER CONDUCTORS ONLY. 4. UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N.E.C AND LOCAL CODES. 5. TO RECALL THE LAST 6 FAULTS, MOST RECENT TO LEAST RECENT, DEPRESS SWITCH FOR MORE THAN SECONDS ILE IN STANDBY (NO THERMOSTAT INPUTS) 6. RED STATUS LED PROVIDES NETWORK STATUS. GREEN RX LED INDICATES NETWORK TRAFFIC. USE LEARN BUTTON TO RESET NETWORK. 7. DISCA CONNECTOR P EN INSTALLING OPTIONAL HEAT KIT. 8. THE CONDENSATE ALARM SWITCH (CAS) TERMINALS CAN ONLY BE UTILIZED WITH COMMUNICATING MODE SETUPS AND MUST BE ENAED WITH A COMMUNICATING THERMOSTAT. THIS FEATURE IS NOT OPERATIONAL WITH LEGACY SYSTEMS. USE N.E.C CLASS WIRE. LOW VOLTAGE (4V) LOW VOLTAGE FIELD HI VOLTAGE (30V) HI VOLTAGE FIELD JUNCTION TERMINAL INTERNAL TO EQUIPMENT GRND FIELD GRND FIELD SPLICE RESISTOR OVERCURRENT PROT. DEVICE PLUG CONNECTION COLOR CODES: PK - PINK BR - BROWN - ITE - UE GY - GRAY - RED YL - YELLOW OR - ORANGE PU - PURPLE GN - GREEN - ACK 0140A0044-B Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. Warning High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. SS-G www.goodmanmfg.com 9

Wiring Diagram 3 Phase Heater Kit NOTE: EN INSTALLING HEATER KIT, ENSURE SPEED TAP MUST EXCEED OR EQUAL THE MINIMUM OWER SPEED (MBS) SPECIFIED FOR THE AIRHANDLER/HEATER KIT COMBINATION ON THIS UNIT'S SERIAL PLATE. AFTER INSTALLING OPTIONAL HEAT KIT, MARK AN "X" IN THE PROVIDED BELOW. NO MARK INDICATES NO HEAT KIT INSTALLED. PC TB CIRCUIT 1 1 PH 08-40V FL HTR3 TL 1 TR 1 4 3 5 FL HTR TL PU 3 PU L3 GND L3 CIRCUIT 3 PH. 08-40V CC R T1 T T3 FL HTR1 TL M1 PU M PU RS M3 M4 BR 4 5 6 7 8 9 BR GR PK EBTDR GR K1 XFMR-R XFMR-C K1 C SPEEDUP M1 SR RC BR BR NO COM NC EM PU PU NOTE:- THIS LABEL MUST BE ATTACHED ON THE AIRHANDLER IN A PROMINENT LOCATION PK RC AR POWER SUPPLY (CIRCUIT 1) TR EM 1 3 4 4 VOLT 5 08/40 VOLTS LOW M1 HIGH C NC NO EBTDR COM GR GR EBTDR PC 1 3 4 5 6 7 8 9 BR W W W1 HKR POWER SUPPLY (CIRCUIT ) L3 T1 T T3 FL HTR3 TL FL HTR TL FL M M4 HTR1 M1 M3 CC RS TL HEATER CONTROL COMPONENT CODE HTR HEAT ELEMENT EM EVAPORATOR MOTOR EBTDR ELEC. OWER TIME DELAY RELAY RS RELAY/SEQUENCER RC RUN CAPACITOR TL THERMAL LIMIT TR TRANSFORMER TB TERMINAL OCK CC CONTACTOR PC 9-PIN CONNECTOR SR STRAIN RELIEF FL FUSE LINK CB CIRCUIT BREAKER WIRING CODE HIGH VOLTAGE LOW VOLTAGE COLOR CODE ACK UE BR BROWN GR GREEN OR ORANGE PK PINK PU PURPLE RED ITE YL YELLOW 0140M0073-A 10 www.goodmanmfg.com SS-G

Accessories Downflow Kits Filters DFK-B DFK-C DFK-D 4B14A* 30C14A* 4D14** 36C14A* 48D14** 48C14A* 60D14** Chassis Part# Size B ALFH1601E 16.0" x 0.0" C ALFH19101E 19.5 x 0.0 D ALFH031E 3.0 x 0.0 Single Point Kit ** Model HKR-15C HKR-0C HKR-1C SPW-01 X X X ** Must be installed along with any of the above compatible heat kits. This kit will fit any air handler as long as a compatible heat kit is installed in the unit. SS-G www.goodmanmfg.com 11

Notes Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 014 Goodman Manufacturing Company, L.P. Houston, Texas Printed in the USA. 1 www.goodmanmfg.com SS-G