Parallelization of an Urban Microscale Flow Model (urbanstream)

Similar documents
CATSI EDM A MILITARIZED SENSOR FOR PASSIVE STANDOFF DETECTION OF CWA

Computer Models For Fire and Smoke

State Machine Modeling of TPED and TPPU. Mr. Ron Funk (DRDC) Mr. Rick Sorensen (Vitech Corp.) NDIA 8 th Sys Engr Conference, San Diego 27 October 2005

Comparison of Thermal Comfort by Radiant Heating and Convective Heating

Study of Hot-air Recirculation around Off-road Tier-4 Diesel Engine Unit Using CFD Abbreviations Keywords Abstract Introduction and Background

MD and Its Impact on Lab Facilities

Modeling and Simulation of Axial Fan Using CFD Hemant Kumawat

Free and Open Source Software Overview and Preliminary Guidelines for the Canadian Forces

Modeling water-mist based suppression of 34 GJ car-deck fires using FDS

INTERNATIONAL STANDARD

Improving Single-Sided Room Ventilation by Using a Ceiling Fan

Official Journal of the European Union. (Non-legislative acts) REGULATIONS

Project Report 6 REFRIGERATION ENERGY USE IN THE FOOD CHAIN PROJECT REFERENCE (TBA) CONTRACT REFERENCE (TBA)

Modeling of Ceiling Fan Based on Velocity Measurement for CFD Simulation of Airflow in Large Room

AS/NZS :2016

Safety by Design. Phone: Fax: Box 2398, RR2, Collingwood, ON L9Y 3Z1

NEW CD WARP CONTROL SYSTEM FOR THE CORRUGATING INDUSTRY

Command approach: Problem bounding vs problem solving in mission command. Keith Stewart DRDC Toronto

COMMISSION DELEGATED REGULATION (EU) /... of

UL Test Methods for Determining the Combustibility Characteristics of Plastics Used in Semiconductor Tool Construction. General Information

Thermal comfort investigation on a naturally ventilated two- storey residential house in Malaysia

Performance Evaluation and Design Optimization of Refrigerated Display Cabinets Through Fluid Dynamic Analysis

Direct measurement of the aerosol absorption and extinction cross section for a variety of chemical and biological simulants in the LWIR

IAFF DIVISION OF OCCUPATIONAL HEALTH, SAFETY AND MEDICINE

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Provläsningsexemplar / Preview TECHNICAL REPORT

Advantages and Disadvantages of Fire Modelling

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

Characterization of a Heat Sink with Embedded Heat Pipe with Variable Heat Dissipating Source Placement for Power Electronics Applications

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Monitoring for Ecological Integrity and State of the Parks Reporting

CEE:3371 Principles of Hydraulics and Hydrology Project #2 Flow Measurement with a Weir

EXTINGUISHMENT AND BURNBACK TESTING OF FIRE FIGHTING AGENTS

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Strengthening Science-Policy-Industry links in the CBRN-E sector. Brussels, 30 th January 2014 Janet Martha Blatny

Domestic Nuclear Detection Office (DNDO)

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

Leak Detection. Ron Threlfall Manager, Leak Detection, Maintenance and Integration

11 th Annual Sucker Rod Pumping Workshop Renaissance Hotel Oklahoma City, Oklahoma September 15-18, 2015

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Användning tak för att minska risken för översvämning orsakade av skyfall

Section d'informatique Section de Systèmes de Communication

MINISTRY OF THE INTERIOR CHIEF-DIRECTORATE FIRE SAFETY AND CIVIL PROTECTION DISASTERS RESPONSE AND UNIFIED RESCUE SYSTEM

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

Virtual Household Refrigerators at Steady-State and Transient Conditions. Numerical Model and Experimental Validation.

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Provläsningsexemplar / Preview TECHNICAL REPORT. Nuclear medicine instrumentation Routine tests

HALON FLIGHTLINE EXTINGUISHER EVALUATION: DATA SUPPORTING STANDARD DEVELOPMENT [INCLUDES NOVEMBER 2007 ADDENDUM]

INTERNATIONAL STANDARD

The French experience on nuclear detection architectures and related reachback Laurent OLMEDO

1.1. SYSTEM MODELING

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

BUSINESS PLAN. CEN/TC 137 Assessment of workplace exposure to chemical and biological agents EXECUTIVE SUMMARY

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

COMMISSION DELEGATED REGULATION (EU) No /.. of

English version. Management Centre: Avenue Marnix 17, B Brussels

Guidance Document Design, Testing and Performance of Exposure Devices RD/GD-352

The Research of Performance Comparison of Displacement and Mixing Ventilation System in Catering Kitchen *

REFRIGERATING SYSTEMS AND HEAT

Radar technology in surveillance

INTERNATIONAL STANDARD

Implementation and testing of a model for the calculation of equilibrium between components of a refrigeration installation

Occasional Paper #15 September, 2002

INTERNATIONAL STANDARD

ISO/TS TECHNICAL SPECIFICATION

Developing OALCF Apprenticeship Tasks for the Competency Use Digital Tasks (2014/2015)

National Certificate in Fire and Rescue Services Airport (Level 3)

power-saving period in summer, in which one of the indoor units was forced to change from a cooling mode to a fan mode, was introduced, and the effect

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

TECHNICAL REPORT. Safety of laser products. Part 10: Application guidelines and explanatory notes to IEC Sécurité des appareils à laser

THE PREMIER EVENT IN FIRE & LIFE SAFETY SAN ANTONIO, TX JUNE HENRY B. GONZALEZ CONVENTION CENTER. June Mon Thurs. June

T22 - Arc Flash Hazards and Arc Resistant Equipment- Understanding the Standards

INTERNATIONAL STANDARD

Cool, calm and collected No cause for alarm on the Grane oil rig

U.S. DEPARTMENT OF ENERGY (DOE) WALK-IN COOLER & FREEZER ENERGY EFFICIENCY RULEMAKING SUMMARY & FREQUENTLY ASKED QUESTIONS. Rulemaking History

infrared inspections efficient solutions. focused results.

AN ANALYSIS OF THE PERFORMANCE OF RESIDENTIAL SMOKE DETECTION TECHNOLOGIES UTILIZING THE CONCEPT OF RELATIVE TIME

ICS Supersedes CLC/TS 62046:2005. English version

This document is a preview generated by EVS

Samsung SDS BMS Ver.2.0. Technical Specification

SVENSK STANDARD SS-EN 26/A2:2005. Gasutrustningar Varmvattenberedare av genomströmningstyp med atmosfärbrännare

Deliverable D9.5. Dissemination Material

This document is a preview generated by EVS

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

API MANUAL OF PETROLEUM MEASUREMENT STANDARDS

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

Electromagnetic Compatibility of Alarm Systems

This document is a preview generated by EVS

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

Resolution XII NOTING also that with the increasingly rapid urbanization, wetlands are being threatened in two principle ways:

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Using FDS Modelling to Establish Performance Criteria for Water Mist Systems on Very Large Fires in Tunnels

ILNAS-EN 61649:2008. Weibull analysis. Analyse de Weibull. Weibull-Analyse

Impact of heat load distribution and strength on airflow pattern in rooms with exposed chilled beams

Marc Genest. Kevin Williams. Orlando, USA. June 2018 CAN UNCLASSIFIE

Smoke and heat control systems Part 1: Specification for smoke barriers

EEENE. AD-AIII 4"- AIR FORCE OCCUPATIONAL AND ENVIRONMENTAL HEAL.TH LAS --ETC F/S 13/11 r

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Simulation innovation in the CBRN training environment UNITED KINGDOM CBRNe UPDATE AND OVERVIEW

Transcription:

Defence Research and Development Canada Recherche et développement pour la défense Canada Parallelization of an Urban Microscale Flow Model (urbanstream) Component 1 of CRTI Project 02-0093RD Fue-Sang Lien and Kun-Jung Hsieh Waterloo CFD Engineering Consulting, Inc. Contract Scientific Authority: E. Yee, DRDC Suffield The scientific or technical validity of this Contract Report is entirely the responsibility of the contractor and the contents do not necessarily have the approval or endorsement of Defence R&D Canada. Defence R&D Canada Contract Report DRDC Suffield CR 2008-024 December 2007

Parallelization of an Urban Microscale Flow Model (urbanstream) Component 1 of CRTI Project 02-0093RD Fue-Sang Lien and Kun-Jung Hsieh Waterloo CFD Engineering Consulting, Inc. 200 University Avenue West Waterloo ON N2L 3G1 Contract Number: W7702-03R966 Contract Scientific Authority: E. Yee (403-544-4605) The scientific or technical validity of this Contract Report is entirely the responsibility of the contractor and the contents do not necessarily have the approval or endorsement of Defence R&D Canada. Defence R&D Canada Suffield Contract Report DRDC Suffield CR 2008-024 December 2007

Her Majesty the Queen as represented by the Minister of National Defence, 2007 Sa majesté la reine, représentée par le ministre de la Défense nationale, 2007

UNCLASSIFIED SECURITY CLASSIFICATION OF FORM (highest classification of Title, Abstract, Keywords) DOCUMENT CONTROL DATA (Security classification of title, body of abstract and indexing annotation must be entered when the overall document is classified) 1. ORIGINATOR (the name and address of the organization preparing the document. Organizations for who the document was prepared, e.g. Establishment sponsoring a contractor's report, or tasking agency, are entered in Section 8.) Waterloo CFD Engineering Consulting, Inc. 200 University Avenue West Waterloo, ON N2L 3G1 2. SECURITY CLASSIFICATION (overall security classification of the document, including special warning terms if applicable) Unclassified 3. TITLE (the complete document title as indicated on the title page. Its classification should be indicated by the appropriate abbreviation (S, C or U) in parentheses after the title). Parallelization of an Urban Microscale Flow Model (urbanstream): Component 1 of CRTI Project 02-0093RD 4. AUTHORS (Last name, first name, middle initial. If military, show rank, e.g. Doe, Maj. John E.) Lien, F.-S. and Hsieh, K.-J. 5. DATE OF PUBLICATION (month and year of publication of document) December 2007 6a. NO. OF PAGES (total containing information, include Annexes, Appendices, etc) 31 6b. NO. OF REFS (total cited in document) 16 7. DESCRIPTIVE NOTES (the category of the document, e.g. technical report, technical note or memorandum. If appropriate, enter the type of report, e.g. interim, progress, summary, annual or final. Give the inclusive dates when a specific reporting period is covered.) Final contract report 8. SPONSORING ACTIVITY (the name of the department project office or laboratory sponsoring the research and development. Include the address.) Defence R&D Canada Suffield, PO Box 4000, Station Main, Medicine Hat, AB T1A 8K6 9a. PROJECT OR GRANT NO. (If appropriate, the applicable research and development project or grant number under which the document was written. Please specify whether project or grant.) CRTI-02-0093RD 10a. ORIGINATOR'S DOCUMENT NUMBER (the official document number by which the document is identified by the originating activity. This number must be unique to this document.) DRDC Suffield CR 2008-024 9b. CONTRACT NO. (If appropriate, the applicable number under which the document was written.) W7702-03-R966 10b. OTHER DOCUMENT NOs. (Any other numbers which may be assigned this document either by the originator or by the sponsor.) WatCFD Report WD001/07 11. DOCUMENT AVAILABILITY (any limitations on further dissemination of the document, other than those imposed by security classification) ( x ) Unlimited distribution ( ) Distribution limited to defence departments and defence contractors; further distribution only as approved ( ) Distribution limited to defence departments and Canadian defence contractors; further distribution only as approved ( ) Distribution limited to government departments and agencies; further distribution only as approved ( ) Distribution limited to defence departments; further distribution only as approved ( ) Other (please specify): 12. DOCUMENT ANNOUNCEMENT (any limitation to the bibliographic announcement of this document. This will normally corresponded to the Document Availability (11). However, where further distribution (beyond the audience specified in 11) is possible, a wider announcement audience may be selected). No limitation on document announcement UNCLASSIFIED SECURITY CLASSIFICATION OF FORM

UNCLASSIFIED SECURITY CLASSIFICATION OF FORM 13. ABSTRACT (a brief and factual summary of the document. It may also appear elsewhere in the body of the document itself. It is highly desirable that the abstract of classified documents be unclassified. Each paragraph of the abstract shall begin with an indication of the security classification of the information in the paragraph (unless the document itself is unclassified) represented as (S), (C) or (U). It is not necessary to include here abstracts in both official languages unless the text is bilingual). The provision of an efficient and accurate Computational Fluid Dynamics (CFD) solver for simulating flows within an urban complex on the microscale (with characteristic length scale extending to about 1-2 km) is required to support the development of an advanced atmospheric transport and diffusion multiscale modeling system for hazard assessment of chemical, biological, radiological or nuclear (CBRN) agents released within cities. The ultimate goal of this supporting effort is to construct a virtual test facility (VTF) that could eventually be used to develop guidelines and procedures for operating in the urban complex after a CBRN incident. Details of the numerical algorithms used for the "stand-alone" microscale CFD solver urbanstream executing on serial computers have been described in the report entitled "Technical Description of Urban Microscale Modeling System: Component 1 of CRTI Project 02-0093RD" by E. Yee, F.-S. Lien and H. Ji (DRDC Suffield TR 2007-067). The objectives of this report are twofold. The first objective is to provide a description of the coupling of urbanstream with an "urbanized" meso-gamma scale flow model (Global Environmental Multi-scale Local Area Model, or GEM LAM, developed by Canadian Meteorological Centre). A ''one-way interaction" scheme is adopted, which allows for the matching of velocity and turbulence field in any overlap region in a physically and mathematically consistent manner that preserves the physical conservation laws, mutually satisfies mathematical boundary conditions, and preserves numerical accuracy. The second objective is to provide implementation details about how urbanstream is parallelized for use on PC clusters and the IBM massively parallel supercomputing platform to give a problem-solving environment for full 3-D parallel simulation. Validation of this fully-coupled mesoscale-to-microscale system is achieved by detailed comparison of model predictions with comprehensive, high-quality full-scale urban measurements in a real cityscape the Joint Urban 2003 (JU2003) conducted in Oklahoma City in the US. 14. KEYWORDS, DESCRIPTORS or IDENTIFIERS (technically meaningful terms or short phrases that characterize a document and could be helpful in cataloguing the document. They should be selected so that no security classification is required. Identifies, such as equipment model designation, trade name, military project code name, geographic location may also be included. If possible keywords should be selected from a published thesaurus, e.g. Thesaurus of Engineering and Scientific Terms (TEST) and that thesaurusidentified. If it is not possible to select indexing terms which are Unclassified, the classification of each should be indicated as with the title.) Computational Fluid Dynamics MPI parallelization Urban Flow simulation UNCLASSIFIED SECURITY CLASSIFICATION OF FORM

Defence R&D Canada Canada's Leader in Defence and National Security Science and Technology R & D pour la défense Canada Chef de file au Canada en matière de science et de technologie pour la défense et la sécurité nationale www.drdc-rddc.gc.ca