Thermal Performance in Mid/ Large Buildings

Similar documents
Chapter 10. Passive Cooling Contents

AR/IA 241 LN 231 Lecture 6: Passive Cooling

Solar Heating and Cooling Systems

EXCELSIOR SINHGAD COLLEGE OF ENGINEERING, PUNE PAPER PRESENTATION

HME09 NATURAL VENTILATION

ABOUT THE SITE CITY PLAN LOCATION:NOIDA,SEC-59

August 15, 2013 Page 1 of 19

100% Outdoor Air Dehumidification Methods

Passive Solar Home Design

CHAPTER 4. HVAC DELIVERY SYSTEMS

Dehumidification Systems

maximize displacement ventilation Opportunities

AR/IA/UP 241 Lecture 5: Psychrometrics

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Benefits Offered by Passive Dehumidification Wheel Speed Control

Heat pump and energy recovery systems

ω = (1) Kirby S. Chapman Ph.D.

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Smart Green Roofs: Cooling with variable insulation

Fourth Edition HEAT TRANSFER AND CHANGE OF PHASE

Greenhouse Temperature Management

MECHANICAL SERVICES 101. Ian White

Chilled Beams. Getting a Warmer Reception

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

Heat Transfer: Conduction. Heat Transfer: Conduction

European Researcher, 2014, Vol.(75), 5-2

Analysis and Evaluation of a Passive Evaporative Cool Tower in conjunction with a Solar Chimney

Air Conditioning and process cooling Energy Components at a Glance

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Recent Advances in Energy, Environment and Economic Development

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

Comfort and health-indoor air quality

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

EFFECTS OF COMBINING SMART SHADING AND VENTILATION ON THERMAL COMFORT

Lesson #12 Home Cooling

In Search of Indoor Comfort

Solar Passive Architecture Cooling Techniques

So far, we have covered the basic concepts of heat transfer and properties.

K.F. Fong *, C.K. Lee, T.T. Chow

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

Adelaide Homes Design Guide 4 - Winter warming

How Much Energy is Really Being Wasted?

DRYING YELLOW-POPLAR IN A SOLAR-DEHUMIDIFIER KILN WITH HEAT STORAGE AND HEAT RECOVERY SYSTEMS

Physical Mechanism of Convection. Conduction and convection are similar in that both mechanisms require the presence of a material medium.

Dehumidification for Industrial Coating Applications. By: Jay Kranker Munters MCS

Impact of indirect evaporative air cooler type on the performance of desiccant systems

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning

A REVIEW ON GREEN TECHNOLOGY IN HVAC

Desiccant Cooling with Solar Energy

Museum of Bavarian History Regensburg, Germany

Appendix 13. Categories of Cooling and Heating systems

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

Evaporative cooling process adaptive for Baghdad city climate

Controlling Wrap-Around Heat Pipes for Systems with Strict Space Humidity Requirements. By Michael O. Davis, PE, August 2015

Raised Access Floor - (AE Breadth Area)

Liquid Desiccant Technology Delivers Energy Cost Reductions and Indoor Air Quality Improvements. White Paper

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

ACHEIVING COMFORT IN SUBTROPICAL CLIMATES: BUILDING A MICROCLIMATE IN THE GUANGZHOU SCIENCE MUSEUM

Air-Cooling Evaporators

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Energy Recovery Ventilation

GEOTHERMAL DESIGN GUIDE

Passive Cooling Systems

Feasibility study of the passive solar room dehumidifying system using the sorption property of a wooden attic space through field measurement

Displacement Ventilation

2013 ASHRAE. Standards & Guidelines CD. Contents

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

Reducing energy use, airstream heat gain, and condensate production

- Murdoch University, Western Australia.

AR/IA 241 LN 231 Lecture 7: Site Planning

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

CONTROL SYSTEM. How to design daylight into your building using electronically tintable glazing.

Comparison Simulation between Ventilation and Recirculation of Solar Desiccant Cooling System by TRNSYS in Hot and Humid Area

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Passive building in Hot and Humid Climates

Steam humidification: Reducing energy use, airstream heat gain, and condensate production

Human response to thermal environment in rooms with chilled beams

How to ensure Thermal Comfort in buildings with CFD

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

SUSTAINABLE LANDSCAPE DESIGN

Simple Solar. Heating & Cooling

Thermal Energy Worksheets

People living in the desert need to wear special clothing in order for them to keep cool.

EqUIPMENT LAYOUT MANUAL

Dynamic performance of a novel dew point air conditioning for the UK buildings

8 5.11: Finned-Tube Coils and Heat Exchangers : Humidifiers and Water Spray Systems : Access for Inspection, Cleaning, and Maintenance

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

Carat. Chilled beams. Use. Worth noting. Installation. Key figures. lindab chilled beams

Desiccant Dehumidifier

SMART GREEN ROOFS: Cooling with Variable Insulation

Technical Assignment 3

SIMULATION ANALYSIS OF BUILDING HUMIDITY CONTROL AND ENERGY CONSUMPTION FOR DIFFERENT SYSTEM CONFIGURATIONS USA

Transcription:

Thermal Performance in Mid/ Large Buildings In Hot, Humid Climates Ross Galloway and Meredith Brown picture cover page minimum resolution 300 dpi width of the picture not wider than the text blocks height of http://upload.wikimedia.org/wikipedia/commons/6/69/icecreamsandwich.jpg the picture minimum 0.6 from last text block csd Center for Sustainable Development

UTSoA - Seminar in Sustainable Architecture Thermal / Humidity Performance in Large Buildings In a Hot and Humid Climate Ross Galloway Meredith Brown main picture of presentation Fig. 01 San Fransisco Federal Building by Morphosis The task of maintaining thermal comfort in large and mid-sized buildings is a complex problem. Since the advent of the modernist movement and the skyscraper, hermetically sealed buildings conditioned by Heating, Ventilating, and Air Conditioning (HVAC) systems have been the standard. This paper will present on overview of several vernacular and passive strategies as an alternative to the standard HVAC system. The paper will begin with a brief description of the performance demands of large buildings in Austin, Texas. Next the paper will address several potential methods for cooling and dehumidifying buildings, any of which can be used alone or in conjunction with other methods, including conventional HVAC systems. The seven main methods presented are: preventing solar heat gain, ventilation strategies, ground cooling, convection cooling, desiccant cooling, evaporative cooling, and use of multiple zones. It should be noted that none of the strategies mentioned in this paper are one size fits all solutions, they should be considered in conjunction with each other and the specific demands of the building. Temperature, Humidity and Comfort The requirements for a building to be heated, cooled, humidified, or dehumidified, will be largely determined by the climate of the building site. For a climate like Austin, Texas, which is hot and humid for most of the year, cooling and dehumidification is most important to ensure comfort and safety for the building s occupants. Comfort, as defined by the American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) in 2004, is that condition of mind which expresses satisfaction with the thermal environment. 1 Architects and engineers should 1

UTSoA - Seminar in Sustainable Architecture Fig. 02 Psychometric Chart showing relationship between temperature, relative humitiy and comfort. by the amount of water vapor that would saturate the air at a given temperature. Relative humidity is used to define comfort rather than absolute humidity because it has a greater impact on perceive comfort. Lew Harriman notes that: Elevated humidity levels reduce comfort. At lower levels of humidity, thermal sensations are a good indicator of overall thermal comfort and acceptability. But, at high humidity levels... thermal sensation alone is not a reliable predictor of thermal comfort. 5 In Figure 1 you can see that comfort, temperature, and relative humidity are all related and the relative humidity at one temperature may feel comfortable, but not at another. design for all variables that affect thermal comfort... air temperature, mean radiant temperature, relative air velocity, water vapor pressure in ambient air, [and occupant] activity level. 2 Thermal conditions which are too extreme, i.e., too hot, too cold, too humid or too dry, can lead to a number of conditions that can affect the safety of a building s occupants, such as hypo- or hyperthermia, dry, itchy eyes and skin, or moist conditions which can lead to mold, mildew and mite or bacteria growth. 3 All of these conditions can be dealt with by the methods laid out in this paper instead of relying solely on a standard HVAC system. Standards Today, the standard method to cool and dehumidify a building is to use a conventional HVAC system with centrifugal chillers. According to the US Department of Energy (DOE), HVAC systems consume 40-60 percent of energy used in large buildings. 4 This high percentage illustrates the impact that innovative air conditioning systems can have. Architects and engineers have a number of tools and technological options at their disposal. By using new as well as traditional or vernacular principles of design, they can substantially reduce the energy consumption of buildings, while improving the comfort and health of the occupants. In the United States, ASHRAE provides the standards for the performance of HVAC systems, as well as guidelines for what is accepted as thermal comfort. According to ASHRAE s psychrometric charts, thermal comfort is defined to be a range of temperatures from 65-75 degrees Fahrenheit, with a relative humidity of 40-60 percent. (See Figure 1) Relative humidity is the amount of water vapor in the air divided Heat Sources and Sinks In large buildings heat is generated by many sources. Lights, people, and other equipment, such as computers, all add heat to the interior of the building. The most significant source of heat gain comes from the sun. Most of the radiation from the sun reaches the earth as light and is then absorbed by surfaces and reradiated as heat. Solar radiation that hits opaque surfaces of a building heats that surface and can add to the interior heat gain of the building if the heat is allowed to transfer through the material to the inside. However, proper insulation and minimal heat sinks in the building s cladding will mitigate solar heat gain through the building skin. Solar heat gain is most prominent through glazed surfaces because of a phenomenon known as the greenhouse effect (fig 2). The greenhouse effect occurs because 2

Thermal/Humidity Performance Fig. 03 The Greenhouse Effect typical glazing is transparent to visible light (short wave radiation) but opaque to heat (long wave radiation). Sunlight enters a building through glass windows as visible light and is absorbed by the surfaces within the building and re-emitted as heat, which cannot escape the building through the glazing. Expulsion of this heat can be achieved either by a mechanical HVAC system, natural ventilation, or a combination of the two. The heat gained by external factors, i.e., the climate, cannot be changed, only designed for, while heat gained from internal sources, such as lighting and mechanical equipment, can often be changed by design to lower the cooling load for a large building. Furthermore, because heat is transferred back and forth between the air and the surfaces by convection, designers often have the choice to cool either the air or the surfaces, such as walls, floors and ceilings. The choice to cool the air or the surfaces will depend on the costs and benefits of particular methods, so solutions should be tailored to each building to optimize efficiency. In addition to expelling heat, large buildings in climates, like Austin, Texas, must dehumidify the air in order to create comfort for the building s occupants.6 High relative humidity can cause people to experience temperatures more extremely. As mentioned before, people can feel hotter or colder in highly humid areas than they would if the relative humidity were lower. In a climate like Austin, for most of the year buildings will feel uncomfortable if the air is not dehumidified, even if the temperature is acceptable. Another important reason to dehumidify the air is because at high temperatures more water vapor is required to fully saturate the air than at lower temperatures. Thus, when hot and humid air is cooled, water vapor can no longer be stored in the air and is released as condensation. Without a system in place to collect that moisture, it can cause damage to mechanical equipment and the building itself, or create health and safety hazards to the building s occupants. Fig. 04 vertical Sunshading limits heat gain on an all glazed face of the San Fransisco Federal Building by Morphosis. Preventing Solar Heat Gain Window Shading In an area like Austin, which receives a lot of sunlight, shading to windows which receive direct sunlight can significantly decrease cooling loads in a building. Design of window orientation and shading should take into account the path of the sun, and an understanding of the times of during the day or year when solar gain is desired to naturally heat a building. Sun shades can be horizontal, louvered, vertical or egg crate shaped, depending on the orientation of the window to reduce direct sunlight and glare. In addition to minimizing solar heat gain when cooling is required, maximizing the use of natural, diffused daylight can cut down the quantity of artificial lights needed in the space, and minimize the heat gain from such light fixtures. 3

UTSoA - Seminar in Sustainable Architecture Roofing Installing a light colored roof will decrease the amount of heat absorbed by reflecting more light than a dark roof, 7 however, the heat reflected off the building by a lightly colored roof can increase the outside temperature, which may actually increase the cooling load for the building. Green roofs are also good insulators and can lower the temperature around the building produced when buildings absorb heat and radiate it back into the atmosphere to increase the temperature, also called the heat island effect. Ventilation Natural Ventilation Natural ventilation is a vernacular strategy that can be used to cool the interior spaces of buildings. The effectiveness of natural ventilation is climate and location dependent because the cooling capacity of natural ventilation is not very high and depends mainly upon the temperature of the outside air. Therefore, for much of the year in Austin, natural ventilation alone cannot cope with the internal heat gains, especially in dense urban areas, where outside temperatures are higher than in rural areas because of the urban heat island effect. 8 Even when natural ventilation alone is insufficient to create comfort, buildings can still be designed to use natural ventilation in conjunction with mechanical HVAC systems. There are several ways to deal with the outside, or supply, air. It can be taken directly into the building s cooling and dehumidification system, or it can be pretreated before fully conditioning it to the desired temperature and humidity. By pretreating supply air, less energy is required to fully condition it, thereby lowering operating costs and improving sustainability. Cross Ventilation A simple and effective form of ventilation, cross ventilation, requires two openings so that air can flow in from one opening and out through another. Cross ventilation occurs naturally when there is a pressure differential between two sides of the building, and is most effective when the intake opening is smaller than the exhaust opening. Pressure differentials occur most commonly because buildings block wind flow, creating positive pressure on the windward side, and negative pressure on the leeward side. In order to maximize the effectiveness of cross ventilation, certain design criteria must be met such as those Fig. 05 Illustration of the multiple forms of natural ventilation. discussed by Dejan Mumovich and Mat Santamouris in A Handbook of Sustainable Building Design and Engineering. The most important key aspect in natural ventilation is the building layout which can enhance airflow. 9 This enhanced layout is a narrow bar with openings along the long sides. Mumovich and Santamouris continue that as a rule of thumb, the limiting depth for effective ventilation is about five times the floor to ceiling height, typically up to 15 m. 10 These design criteria are limiting for many building types and functions that require larger floor plans, but other natural ventilation options are also available. Stack Ventilation If a building is unable to use crossventilation effectively, ventilation can be enhanced by utilizing the physical principle that cold air, which is more dense than hot air, will sink towards the ground, pushing hot air up 4

Thermal/Humidity Performance towards the ceiling. This is called the stack effect. [Stack ventilation] may occur via purposefully built vertical ducts or via an internal atrium or other type of vertical spacial continuity within the building. Stack ventilation is buoyancy driven and relies on density differences to draw cooler, denser outdoor air into a building via low level vents and to exhaust warmer, less dense indoor air via high level vents. 11 The technique eliminates the need for a narrow building because heat can escape at predetermined intervals in the roof and does not require external differentials like cross-ventilation. By venting hot air through a small aperture in the ceiling, a pressure differential will be created which will increase the velocity of the air as it exits the building, creating an updraft which will further improve airflow. Displacement Ventilation Displacement ventilation is another form of ventilation which uses the principles of air buoyancy, and can be used with either natural ventilation or a combination of natural and mechanical ventilation. If outside air is cool and clean enough it can be supplied to the spaces as is, in an area like Austin, this would only be practical in the cooler, less humid months such as early spring or late autumn. During the summer, when the air is hot and humid, air can be pre-cooled and mechanically cooled and then: supplied at low velocities and at a lower level, usually through a raised floor This air is heated only when it comes into contact with an internal heat source, rises up and is extracted through upper levels outlets, usually mounted in the ceiling. 12 This cooling technique is particularly effective because it supplies cold air to lower parts of the room, where people are working and living and allows the higher levels of the building where which are people free to be hotter, much like the stack effect. Night Ventilation Night ventilation can be used in an area like Austin in the late autumn and early spring when night-time temperatures are lower than daytime comfort temperatures. The purpose of night ventilation is to store the cooler night time temperatures in a thermal mass, a material with a high heat capacity whose temperature will not change quickly, which will then absorb heat from the room during the day. The process is described by Mumovich and Santamouris: During the daytime, the exposed thermal mass, usually the slab, provides radiant cooling by absorbing internal heat gains. When night time comes, the absorbed heat gains are spread out of the building by cooling the exposed thermal mass using ventilation. The following day, the thermal mass is able to absorb more heat than it would otherwise. Significantly reducing the need for mechanical cooling. 13 In order for night ventilation to work effectively, the building needs to be designed specifically with Fig. 06 Narrow Floorplan and section to induce cross ventilation. San Fransisco Federal Building by Morphosis. Fig. 07 Application of stack effect to draw heat out of a large volume space. Exhibition Hall in Hanover by Herzog and Partner. 5

UTSoA - Seminar in Sustainable Architecture or cool a space using convection. Jane Wiens explains that, warm air rises and is cooled by the chilled beam; once it s cooled, the air falls back to the floor, where the cycle starts over. 15 This system can be used without forcing air through the beams, but may not always be sufficient to heat or cool the entire space. Chilled Slabs Fig. 08 Diagram of airflow over slab for night cooling. San Fransisco Federal Building by Morphosis. an exposed thermal mass and a ventilation scheme that moves air over or through the mass. Furthermore, in areas with extreme highs and extreme lows, the thermal mass may become Ground Cooling Supply air can also be pretreated by using the thermal properties of the ground before entering the mechanical system of the building. The temperature of the earth only a few meters below the surface is far less variable than the air temperatures at the surface because the earth has a high heat capacity. One common way to use ground cooling is to pump supply air through pipes in the ground to lower the temperature of the air before it enters the building, which will lighten the cooling load on the mechanical system. (fig. 09) A similar system can use water rather than air. In this case, water is pumped deep into the ground and is then used to cool 6 supply air as it enters the building. Buildings close to bodies of water can use the thermal qualities of the those bodies of water in the same way by passing that water through a heat exchanger.14 Another way to pre-treat the air is to send the exhaust air and the incoming supply air through a heat exchanger to pretreat the supply air using the exhaust air before the supply air enters the mechanical system. This way some of the energy that went into conditioning the exhaust air can be recovered. Similar to chilled beams are chilled slabs, where cool air or water is injected through a slab that has been cooled, often by night cooling, to pre-cool the air in order to condition the space.16 Air close to the ground is cooled by radiating its heat to the slab, and rises as it is heated by people and equipment. Radiant cooling can supply the same cooling capacity as other systems but at levels of energy consumption that are typically about 75 percent of those for air-based systems. 17 The same system can be used to heat the space by running heated water through the slab and radiating heat instead of absorbing it. Desiccant Cooling Convection Cooling Chilled Beams and Ceilings Chilled beams and chilled ceilings use similar physical principles as ground cooling, but instead of supplying cool air at the ground, chilled or hot water is run through pipes embedded in long beams at the ceiling, which will then heat Fig. 09 Ground cooling.

Thermal/Humidity Performance In a climate like Austin, pure natural ventilation is often not sufficient in and of itself to cool a building without lowering the moisture content in the air. Therefore, desiccant cooling, using a chemical compound to absorb moisture from the air, can be an effective solution that doesn t use an HVAC system. For desiccant cooling: the introduced air passes through a desiccant wheel and [the] moisture is removed by [transferring it] to the heated extract air. After the desiccant wheel, the incoming air is cooled by a heat recovery device; this cooling load stems from the extract air. 18 (Fig. 10) Desiccant cooling works very well in Fig. 10 Dessicant Cooling Process Fig. 11 Indirect Evaporative Cooling Process hot and humid climates but requires a large amount of infrastructure in order to channel all the supply air through the desiccant wheel. Evaporative Cooling Perhaps counter-intuitively, evaporative cooling, which uses water to cool the air, can also work in a hot and humid climate. Direct evaporative cooling, which cools the supply air by spraying water on it directly, is not an effective method in a climate like Austin where the relative humidity in warms months is high. However, indirect evaporative cooling can be effectively used in an area like Austin. An Energy Star publication describes indirect evaporative cooling thus: indirect systems cool one air stream that in turn cools the supply air stream through a heat exchanger. Although indirect systems are more costly, they avoid increasing the humidity of supply air. Evaporative cooling can also be used to precool air to reduce the load on a mechanical refrigeration system. 19 (fig. 10) By not allowing the humidified air to mix with the air supply, the benefits of the cooling process can be used indirectly. The publication goes on to note that: compared with standard unitary air-conditioning equipment, indirect evaporative coolers have been shown to use 70 percent less electricity seasonally. 20 Multiple Zones In large buildings multiple zones are often created to better serve the heating and cooling needs of different parts and uses of the buildings. These zones can be used to maximize the possibility of natural thermal control in buildings that as a while would be unsuitable. In addition to zoning buildings, automated building controls and systems can regulate interior and exterior temperatures, and adjust building components accordingly by opening windows, turning off lights, rotating louvers, etc. Systems like this are often quite complex, but are often necessary in large buildings where large numbers of users cannot be counted on to manually alter the system s components. In the case of a large building such as a train station, different zones need to be created to deal with many different uses served. Platforms and other exposed area will need 7

UTSoA - Seminar in Sustainable Architecture distinct cooling strategies from more enclosed areas, such as offices, ticket counters and commercial spaces. In the same way, building systems that can react to exterior conditions could be very beneficial in creating a comfortable semi-exposed platform. Using Multiple Cooling Methods As well as developing natural ventilation and thermal comfort strategies, selecting an efficient mechanical HVAC system is very important. When designing with the intent to use natural cooling and heating methods, it is important that HVAC systems be as flexible as possible to meet peak demand when necessary, but also serve a supporting role when conditions are right for natural methods. In hot and humid climates that means the cooling component, or chiller, needs to be able to run efficiently at many different output levels, and needs to be integrated with other building systems so that it only runs when it needs to. 21 Conclusion In Austin, Texas, where the climate is a hot and humid most of the year, large buildings need to be dehumidified and cooled to ensure the comfort of the building s occupants. In order to use methods of temperature and humidity control that do not rely solely on HVAC systems, it is important to understand the physical principles and technical methods used in vernacular and natural ventilation strategies. An understanding of physical principles, such as heat transfers and flows, pressure differentials, etc., enables designers to make smart decisions about building systems. The methods described in this paper; sun shading, natural ventilation techniques, ground cooling, chilled beams or walls, desiccant cooling and evaporative cooling all have their times and places when best used. Some of them can and should be used simultaneously. Striking a balance between mechanical and natural systems is critical when designing with both sustainability and user comfort in mind, and it is often site and building specific. Hopefully, with this overview of a number of the possible ways to condition a large building, this paper will help designers more effectively understand what their options are when creating a sustainable and comfortable building. Figures 1. Source: Moe, Kiel. Integrated Design in Contemporary Architecture. 2. http://www.ent.ohiou.edu/~thermo/applied/ Chapt.7_11/Psychro_chart/comfort_zone.gif (accessed dec. 10th 2009) 3. Source: Herzog, Krippner, Lang. Façade Construction Manual. Basel: Birkhauser 2004. p. 25 4. Source: Moe, Kiel. Integrated Design in Contemporary Architecture. New York: Princeton Architectural Press, 2008. 5. Source: A Handbook of Sustainable Building Design and Enginneering: An Integrated Approach to Energy, Health and Operational Performance (Buildings, Energy and Solar Technology Series). London: Earthscan Publications Ltd., 2009. 6. Source: Moe, Kiel. Integrated Design in Contemporary Architecture. New York: Princeton Architectural Press, 2008. 7. Source: Herzog. Thomas (ed.). Hall 26. München: Prestel 1996, p. 28 8. Source: A Handbook of Sustainable Building Design and Enginneering: An Integrated Approach to Energy, Health and Operational Performance (Buildings, Energy and Solar Technology Series). London: Earthscan Publications Ltd., 2009. 9. Source: Moe, Kiel. Integrated Design in Contemporary Architecture. New York: Princeton Architectural Press, 2008. 10. Source: A Handbook of Sustainable Building Design and Enginneering: An Integrated Approach to Energy, Health and Operational Performance (Buildings, Energy and Solar Technology Series). London: Earthscan Publications Ltd., 2009. 11. Source: A Handbook of Sustainable Building Design and Enginneering: An Integrated Approach to Energy, Health and Operational Performance (Buildings, Energy and Solar Technology Series). London: Earthscan Publications Ltd., 2009. 8

Thermal/Humidity Performance References 1. Benjamin Stein, et al., Mechanical and Electrical Equipment for Buildings, 10 th Edition (New Jersey: John Wiley and Sons, Inc., 2006), 86 2. Dejan Mumovich and Mat Santamouris, A Handbook of Sustainable Building Design and Engineering (London:Earthscan Publications, 2009), 181 3 Lew Harriman et al., Humidity Control Design Guide for Commercial and Institutional Building (Georgia: American Society of Heating, Refrigerating, and Air Conditioning Engineers, 2001), 100-137 4 U.S. Department of Energy, Energy Efficiency and Renewable Energy, Building Technologies Program., Commercial Buildings, Heating, Ventilating and Air Conditioning, U.S. Department of Energy, http://www1.eere.energy.gov/buildings/ commercial/hvac.html (accessed October 21, 2009) 5 Lew Harriman et al., Humidity Control Design Guide for Commercial and Institutional Building (Georgia: American Society of Heating, Refrigerating, and Air Conditioning Engineers, 2001), 74 6 Ibid. 7 Energy Star Products. Reflective Roof Products: for Consumers. Energy Star. http:// www.energystar.gov/index.cfm?c=roof_prods. pr_roof_products (accessed December 4, 2009). 8 Dejan Mumovich and Mat Santamouris, A Handbook of Sustainable Building Design and Engineering (London: Earthscan Publications, 2009), 235 9 Ibid. 272 10 Ibid. 232 11 Ibid. 233 12 Ibid. 277 13 Ibid. 272 14 Ibid. 275-276 15 Weins, Janet. 1) Chilled Beam System. Buildings: Facilities Management, Commercial Buildings, Institutional Buildings, Government Buildings. http://www.buildings. com/articledetails/tabid/3321/articleid/6087/ Default.aspx (accessed October 21, 2009). 16 Dejan Mumovich and Mat Santamouris, A Handbook of Sustainable Building Design and Engineering (London: Earthscan Publications, 2009), 279 17 Agency, U.S. Environmental Protection. Energy Star Buildings manual : Energy Star Buildings Program (SuDoc EP 1.8:B 86). New York: U.S. Environmental Protection Agency, Global Change Division, 2008. 23 18 Dejan Mumovich and Mat Santamouris, A Handbook of Sustainable Building Design and Engineering (London: Earthscan Publications, 2009), 279 19 Agency, U.S. Environmental Protection. Energy Star Buildings manual : Energy Star Buildings Program (SuDoc EP 1.8:B 86). New York: U.S. Environmental Protection Agency, Global Change Division, 2008. 25 20 Ibid. 21 Ben Erpelding Real Efficiencies of Central Chilled-Water Plants, HPAC Engineering - News and Articles for Heating, Piping and Air-Conditioning Professionals, http://hpac. com/mag/real_efficiencies_central/ (accessed October 20, 2009) 9