Inverter Room Air Conditioner Installation Manual KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC

Similar documents
Fixed Speed Split Room Air Conditioner Installation Manual KSE26CRC, KSE26HRC, KSE35CRC, KSE35HRC, KSE53HRC, KSE62HRC, KSE70CRC, KSE70HRC, KSE88CRC

Split Air Conditioner

Split Air Conditioner

ERR627SA ERR927SA. Rangehood Installation manual

USER MANUAL RANGE HOOD CG920FGS. User manual_cg920fgs 28/11/2012

INSTRUCTION MANUAL / INSTALLATION MANUAL. 7kg Vented Dryer MODEL: KA7VENTDRYA

ETLW7. Product: 7kg Top Load Washing Machine. User Manual

USER MANUAL COOKING. Model: WRG920FGS. Rangehood

REHR6* WRH605I* WRH608I* WRR614*A WRH908I* Retractable Rangehood User manual

Gas Continuous Flow Hot Water System User Manual

User Manual. Dishwasher DSF6106W DSF6106X

USER MANUAL REFRIGERATION WCM1400W D, WCM2000W D, WCM2900W D

User Manual. Dishwasher DSF6206W DSF6206X DSF6216X

USER MANUAL REFRIGERATION WCM1400WD, WCM2000WD, WCM2900WD, WCM5000WD & WCM7000WD

INVERTER SPLIT - TYPE

USER MANUAL ELECTRIC COOKTOP

Kelvinator Air Conditioning front/rear view 1

Ceramic Cooktops User and Installation Manual

ERCE9025BK ERCE9025BA

USER MANUAL CERAMIC HOBS WHC642BA, WHC742BA, WHC644SA, WHC942BA, WHC322BA

MODELS WHS642WA, WHS642SA CHS642WA, CHS642SA CHS942WA. SOLID ELEMENT COOKTOPS User and Installation Manual

Ceramic Cooktops User and Installation Manual

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

Window Wall (Manual) Room Air Conditioner User Manual KWH15CMB, KWH20CMB Refrigerant R410A

ROOM AIR CONDITIONER INSTALLATION MANUAL

Contour Gen 3 U4210 Mightymite Gen 3 U4214 Instruction Manual

Kind Regards, The Residentia Team

USER MANUAL CERAMIC COOKTOPS WHC644BA, WHC744BA, WHC944BA, WHC934BA

Installation & User manual Canopy cooker hood ERHC1238S ERHC938S

INSTALLATION & USER MANUAL CANOPY RANGEHOOD WRC613SB, WRC913SB

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

OWNER S GUIDE NZ: U2950 Series

Split Air Conditioner

EUF92W. Product: Bar Freezer. User Manual

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

USER MANUAL. Multi Door Refrigerator WME3600SA

Mega Gen 3 U5010 & Ultima Gen 3 U5011 Instruction Manual ULTIMA & MEGA IFU_V5.indd 1 3/10/08 2:40:58 PM

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Choosing the installation site. Installation. 07 Choosing the installation site

EUF92W EUF92S. Product: Bar Freezer. User Manual

2.9kW Portable Air Conditioner

2.9kW Portable Air Conditioner

User Manual\ Canopy Rangehood\ RH92G\RH92GB\RH62GB

EDC2086PDW EN TUMBLE DRYER USER MANUAL

Vortex U4015 Instruction Manual VORTEX U4015 IFU V3.indd 2 2/10/08 1:37:23 PM

ETLW55. Product: 5.5kg Top Load Washing Machine. User Manual

Sunbeam Tower Fan with Night Mode

User manual. Induction Hob EHC65 7U CHE654SC CHE655SC

R410A SPLIT SERIES DC INVERTER

CLUBMAN. Assembly and Operating Instructions AUSTRALIA / NEW ZEALAND FOR MODELS: 16440, 16540, FOR OUTDOOR USE ONLY

INSTALLATION & OPERATION INSTRUCTIONS

EE62T-NB. Product: 60cm Ceramic Cooktop. User Manual

CLASSIC 4 SLICE TOASTER 2 YEAR WARRANTY RHT14 SERIES RHT14_IB_FA_ Part No. T

SPLIT-TYPE ROOM AIR CONDITIONER

User manual Ceramic Glass Hob EHC644BA EHC944BA

MariGlo LED. Inspiring Excellence in Fish Keeping! 45 / 60 / 90 / 120.

INTEGRATED SIDE BURNER

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Heat Pump Hot Water System User Manual

2000 WATT CYCLONIC BAGLESS VACUUM CLEANER

RHT420_IB_FA_ Part No. T KINGSTON 2 SLICE TOASTER 2 YEAR WARRANTY RHT420 SERIES

FAVORIT W0P/AU FAVORIT M0P/AU. EN User manual

EDC2086GDW. EN Tumble Dryer User Manual

Reverse Cycle Inverter Split System Air Conditioner

LUCCI WHITEHAVEN DC CEILING FAN

BAKE EXPERT MINI TOASTER OVEN

SPLIT -TYPE ROOM AIR CONDITIONER

User Manual Freezer AGN81800C0

HK614010MB. EN User manual

YORK KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 20431AU 20431AU_IB_FA_190314

RHK112_IB_FA_ Part No. T INSPIRE KETTLE 2 YEAR WARRANTY RHK112 SERIES

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

EDH3786GDW. EN Tumble Dryer User Manual

User Manual Refrigerator SKD81800C0

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Convection Panel Heater

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

80cm Tower Fan With Remote Control

User Guide. Please read carefully before use. Your Hoover Guarantee. Your Hoover Guarantee. Contents. IMPORTANT Safety Reminders

SEVILLE KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 18152AU 18152AU_IB_FA_240712

WELCOME BLUE - NEUTRAL BROWN LIVE GREEN AND YELLOW - EARTH

VC10LPH with HEPA Filter & Disposable Dust Bag

ARTICA. 8000Btu. Room Air Conditioners Portable Range

Inverter Air Conditioner Installation Manual

INVERTER SPLIT - TYPE ROOM AIR CONDITIONER

OWNER S MANUAL. CoolTower CTF07. (English) (CTF07)

User Manual. Deep Cleaning Bagless Vacuum with Powerhead. Deep Clean W3000

60cm Electric Built-in Oven (5 Functions)

ESL 6610RO EN DISHWASHER USER MANUAL

Air Conditioner. user installation & manual manual. imagine the possibilities

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

USER MANUAL GHR16S, GHR16W, GHR17S, GHR17W, GHR765S, GHR775S, GHR95S, GHR95W, GHR795S GAS COOKTOPS

YEAR 2WARRANTY. Windsor Kettle MODEL RHK3 INSTRUCTIONS & WARRANTY RHK3_IB3_281011

RHK52_IB_FA_ Part No. T HERITAGE VOGUE KETTLE 2 YEAR WARRANTY RHK52 SERIES

user manual Ceramic glass hob PHN768U, PHN798U

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205

Instuction Booklet. 4 Slice Toaster - TA9400 / Slice Toaster - TA9200 / 9205

Transcription:

Inverter Room Air Conditioner Installation Manual KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC Refrigerant R410A

Congratulations Contents Congratulations and thank you for choosing our Inverter Speed Split room air conditioner. We are sure you will find your new air conditioner a pleasure to use. Before you use the air conditioner, we recommend that you read through the entire user manual, which provides the description of the air conditioner and its functions. To avoid the risks that are always present when you use an electrical appliance, it is important that the air conditioner is installed correctly and that you read the safety instructions carefully to avoid misuse and hazards. We recommend that you keep this instruction booklet for future reference and pass it on to any future owners. After unpacking the air conditioner please check it is not damaged. If in doubt, do not use the air conditioner but contact your local Electrolux Customer Care Centre. Contents... 2 Safety precautions... 3 Notice for installation... 3 Installation drawing... 5 Installation of indoor unit... 6 Refrigerant pipe connection... 8 Installation of outdoor unit... 9 Check after installation and operation test... 10 Installation and Maintenance of HEPA Filter... 10 Warranty... 11 environmental tip Information on disposal for users Most of the packing materials are recyclable. Please dispose of those materials through your local recycling depot or by placing them in appropriate collection containers. If you wish to discard this air conditioner, please contact your local authorities and ask for the correct method of disposal. caution The air conditioner is not intended for use by young children or infirmed persons without supervision. Young children should be supervised to ensure that they do not play with the air conditioner. Contact an authorised installer for installation of this unit. Contact an authorised service technician for repair or maintenance of this unit. If the power cord is to be replaced, replacement work shall be performed by authorised personnel only. Installation work must be performed in accordance with the national wiring Standards by authorised personnel only. Conditions of use This appliance is intended to be useed in household and similar applications such as: Staff kitchen areas in shops, offices and other working environments Farm houses By clients in hotels, motels, and other residential type environments Bed and breakfast type environments 2 Contents Kelvinator Air Conditioning

Important safety instructions Notice for installation Please read this installation manual and the user manual before installation and carefully store in a handy place for later reference. Inside you will find many helpful hints on how to install and test the air conditioner properly. Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed. Incorrect installation due to ignoring this instruction will cause harm or damage, and the seriousness is classified by the following indications. Meanings of symbols used in this manual are shown below: warning This symbol indicates information concerning your personal safety caution This symbol indicates information on how to avoid damaging the appliance tips and information This symbol indicates tips and information about use of the appliance environmental tip This symbol indicates tips and information about economical and ecological use of the appliance This symbol indicates never to do this This symbol indicates always do this caution 1 The unit must only be installed by a qualified refrigeration mechanic and electrical work carried out by a qualified electrician according to local or government regulations and in compliance with this manual. 2 Before installation, please contact a qualified air conditioner installer. If the unit is not installed by a qaulified air conditioner installer, the malfunction may not be solved due to faulty installation. 3 If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 4 The appliance must be positioned so that the plug is accessible. 5 The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube. 6 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 7 For appliances with type Y attachment,the instructions shall contain the substance of the following. If the supply cord is damaged,it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. warning Before obtaining access to terminals, all supply circuits must be disconnected. Kelvinator Air Conditioning Important safety instructions/notice for installation 3

Installation Site Instructions A proper installation site is vital for correct and efficient operation of the unit. Avoid the following sites where: strong heat sources, vapours, flammable gas or volatile liquids are emitted. high-frequency electro-magnetic waves are generated by radio equipment, welders or medical equipment. salt-laden air prevails (such as close to coastal areas). the air is contaminated with industrial vapours and oils. the air contains sulphurous gas such as in hot spring zones. corrosion or poor air quality exists. Installation Site of Indoor Unit 1 The air inlet and outlet should be away from the obstructions. Ensure the air can be blown through the whole room. 2 Select a site where the condensing water can be easily drained out, and where it is easily connected for the outdoor unit. 3 Select a place where it is out of reach of children. 4 Select the place where the wall is strong enough to withstand the full weight and vibration of the unit. 5 Be sure to leave enough space to allow access for routine maintenance. The installation site should be 2m or more above the floor. 6 Select a place about 1m or more away from a TV set or any other electric appliance. 7 Select a place where the filter can be easily taken out. 8 Make sure that the indoor unit is installed in accordance with installation dimension instructions (refer to page 5). 9 Do not use the unit in the laundry or by swimming pool etc. Installation Site of Outdoor Unit 1 Select a site where noise and outflow air emitted by unit will not annoy neighbors. 2 Select a site where there is sufficient ventilation. 3 Select a site where there is no obstruction blocking the inlet and outlet. 4 The site should be able to withstand the full weight and vibration of the unit. 5 Select a dry place, but do not expose the unit to direct sunlight or strong wind. 6 Make sure that the outdoor unit is installed in accordance with the installation instructions, and is convenient for maintenance and repair. 7 The height difference between indoor and outdoor units complies with the table on page 8. 8 Select a place where it is out of reach of children. Safety Precautions for Electric Appliances 1 A dedicated power supply circuit should be used for products not supplied with a service cord and plug in accordance with local electrical safety regulations. 3 The unit must be reliably earthed and connected to the special earth device by the qualified electrician. 4 The circuit breaker must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload. 5 The appliance shall be installed in accordance with national wiring regulations. 6 Including an circuit breaker with suitable capacity, please note the following table. Model Circuit Breaker (Amps) KSV26CRC 10 KSV26HRC 10 KSV35CRC 10 KSV35HRC 10 KSV53HRC 15 KSV62HRC 15 KSV70CRC 20 KSV70HRC 20 KSV80HRC 20 Note: Make sure the live wire, neutral wire and earth wire in the power socket are properly connected. Inadequate or incorrect electrical connections may cause electric shock or fire. Earthing Requirements 1 Air conditioner is type I electric appliance. Please ensure the unit is reliably earthed. 2 The yellow-green wire in air conditioner is the earthing wire which can not be used for other purposes. Improper earthing may cause electric shock. 3 The earth resistance should accord to the national wiring regulation. 4 The user's power must have reliable earthing terminal. Do not connect the earthing wire with the following: 1. Water pipe 2. Gas pipe 3. Contamination pipe 4 Notice for installation Kelvinator Air Conditioning

Installation drawing Space to the ceiling 15cm Above Space to the wall 15cm Above 15cm Above Space to the wall 300cm 200 Above cm Above Air outlet side Space to the floor The dimensions of the minimum in between space necessary for properinstallation of the unit include the minimumpermissible distances to adjacent parts. Space to the obstruction 50cm Above Air inlet side 30cm Above Space to the wall 200cm Above 30cm Above Space to the wall 50cm Above Air outlet side If these dimensions are not adhered to the air conditioner will not perform to specification, may not be able to be serviced and the warranty may be voided. the installation must allow for reasonable access Kelvinator Air Conditioning installation drawing 5

Installation of indoor unit Installation of Mounting Plate 1 The mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of condenser water. 2 Fix the mounting plate on the wall with screws. 3 Be sure that the mounting plate has been fixed firmly enough to withstand about 60kg. Meanwhile, the weight should be evenly shared by every screw. Note: All dimensions are in mm. 2.6kW UNIT: 2 Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole. Indoor Wall pipe Installation of Drain Hose Outdoor Seal pad Ø55/ Ø65 1 Connect the drain hose to the outlet pipe of the indoor unit. Bind the joint with rubber belt. 34.5 3.5kW UNIT: outlet pipe of indoor unit rubber belt outlet pipe of indoor unit drain hose Ø55 Ø55 316 2 Put the drain hose into insulating tube. 34.5 outlet pipe of indoor unit drain hose 5.2kW UNIT: rubber belt insulating tube 3 Wrap the insulating tube with wide rubber belt to prevent the shift of insulating tube. Slant the drain hose downward slightly for smooth drainage of condensing water. 6.2 kw, 7.0 kw and 8 kw UNITS: rubber belt outlet pipe of indoor unit connected insulating tube Drill Piping Hole 1 Slant the piping hole on the wall slightly downward to the outdoor side. Piping hole Units ( 55) 2.6 kw, 3.5 kw and 5.3kW ( 65) 6.2 kw, 7.0 kw and 8 kw Note: The insulating tube should be connected reliably with the sleeve outside the outlet pipe. The drain hose should be slanted downward slightly, without distortion, bulge or fluctuation. Do not put the outlet in the water. bulge distortion Flooded 6 Installation instructions Kelvinator Air Conditioning

Installation of indoor and outdoor electric wires 1 Open the front panel. 2 Remove the wiring cover connect and fix power connection cord to the terminal board as shown in Fig 6. 3 Make the power connection cord pass through the hole at the back of indoor unit. 4 Reinstall the cord anchorage and wiring cover. 5 Reinstall the front panel. For 2.6kW and 3.5kW units: Wiring Cover N(1) 2 3 blue black brown yellow- green outdoor unit connection 2 Take out the piping from body case, wrap the piping, power cords, drain hose with the tape and then make them pass through the piping hole. (As shown in Fig.2) 3 Hang the mounting slots of the indoor unit on the upper hooks of the mounting plate and check if it is firm enough. (As shown in Fig.3) 4 The installation site should be 2m or more above the floor. Fig.1 Fig.2 Tailing 2 Tailing 1 Gas side pipe Gas side piping insulation Finally wrap it with tape External connection electric wire Liquid side piping Liquid side Piping insulation Water drainage pipe For 5.3kW, 6.2kW, 7.0kW and 8kW units: Left Wiring Cover N(1) 2 3 blue black brown yellow- green outdoor unit connection Fig.3 Right Right rear Fixing hook Mounting plate Left rear Mounting plate Note: All wires between indoor and outdoor units must be connected by a qualified electric contractor. Electric wires must be connected correctly. Improper connection may cause malfunction. Tighten the terminal screws tightly. After tightening the screws, pull the wire slightly to confirm whether it's firm or not. Make sure that the electric connections are earthed properly to prevent electric shock. Make sure that all wiring connections are secure and the cover plates are reinstalled properly. Poor installation may cause fire or electric shock. Installation of Indoor Unit The piping can be output from right, right rear, left or left rear. 1 When routing the piping and wiring from the left or right side of indoor unit, cut off the tailings from the chassis when necessary (As shown in Fig.1) a. Cut off the tailings 1 when routing the wiring only; b. Cut off the tailings 1 and tailings 2 when routing both the wiring and piping. Installation of Connection Pipe Align the center of the piping flare with the related valve. Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench by referring to the following: Hex nut diameter Tightening torque (N m) 6 15~20 9.52 30~40 12 45~55 16 60~65 19 70~75 For installations with connecting pipes greater than 5m, additional refrigerant is required at the following rates per extra metre of pipe. 2.6 kw & 3.5 kw Reverse cycle 20g/m 2.6 kw & 3.5kW Cooling only 15g/m 5.3 kw & 6.2 kw Reverse cycle 50g/m 7.0 kw Cooling only, 7.0 kw & 8.0 kw Reverse cycle 50g/m Kelvinator Air Conditioning Installation instructions 7

Refrigerant pipe connection 1 Flaring work Main cause for refrigerant leakage is due to defects in the flaring work. Carry out correct flaring work using the following procedure: 90 C Oblique Roughness Burr A: Cut the pipes and the cable. 1 Use the piping kit accessory (if applicable) or pipes purchased locally. 2 Measure the distance between the indoor and the outdoor unit. 3 Cut the pipes a little longer than the measured distance. 4 Cut the cable 1.5m longer than the pipe length. B: Burr removal 1 Completely remove all burrs from the cut cross section of pipe/tube. 2 Face the end of the copper pipe/tube in a downward direction as you remove burrs in order to avoid burrs dropping into the tubing. Outer diam. (mm) Bar Max. A(mm) Min. φ6.35 1.3 0.7 φ9.53 1.6 1.0 φ12.7 1.8 1.0 φ16.0 2.4 2.2 "A" Copper pipe Bar Clamp handle Handle Yoke Cone Red arrow mark Tightening Connection Align the center of the pipes. Sufficiently tighten the flare nut with fingers, and then tighten it with a spanner and torque wrench as shown below. Pipe Reamer Indoor unit tubing Flare nut Pipings Face down Outer diam. Tightening torque (Kg.m) Additional Tightening Torque (Kg.m) φ6.35 1.6 2.0 caution C: Putting flare nut on Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal Note: It is not possible to put them on after flaring work. Copper tube Flare nut φ9.53 3.0 3.5 φ12.7 5.0 5.5 φ16.0 7.5 8.0 caution Excessive torque can break nut depending on installation conditions. E: Check Compare the flared work with the adjacent diagram. If flare is found to be defective, cut off the flared section and do flaring work again. D: Flaring work Carry out flaring work using flaring tool as shown below. Firmly hold copper pipe in a die according to the dimension shown in the table below. Smooth all round Improper flaring Even length all round 8 installation instructions Kelvinator Air Conditioning

For 5.3kW, 6.2kW, 7.0kW and 8kW units: Handle Indoor unit piping Taper nut Piping N(1) 2 3 yellow- green blue black brown Spanner Torque wrench indoor unit connection Model Discharge (mm) Suction (mm) Maximum lenght Maximum Height KSV26CRC 6.4 (1/4") 9.5 (3/8") 15 10 KSV26HRC 6.4 (1/4") 9.5 (3/8") 15 10 KSV35CRC 6.4 (1/4") 9.5 (3/8") 20 10 KSV35HRC 6.4 (1/4") 9.5 (3/8") 20 10 KSV53HRC 6.4 (1/4") 16.0 (5/8") 25 10 KSV62HRC 6.4 (1/4") 16.0 (5/8") 20 10 KSV70CRC 6.4 (1/4") 16.0 (5/8") 25 10 KSV70HRC 6.4 (1/4") 16.0 (5/8") 25 10 KSV80HRC 6.4 (1/4") 16.0 (5/8") 25 10 Note: Connect the connection pipe to indoor unit at first and then to outdoor unit. Handle piping bending with care. Do not damage the connection pipe. Ensure that the joint nut is tightened firmly, otherwise, it may cause leakage. Installation of outdoor unit Electric wiring 1 Remove the handle on the right side plate of outdoor unit. 2 Take off wire cord anchorage. Connect and fix power connection cord to the terminal board. Wiring should fit that of indoor unit. 3 Fix the power connection cord with wire clamps and then connect the corresponding connector. 4 Confirm if the wire has been fixed properly. 5 Reinstall the handle. For 2.6kW and 3.5kW units: Handle N(1) 2 3 yellow- green blue black brown indoor unit connection Air Purging and Leakage Test 1 Connect charging hose of manifold valve to charge end of low pressure valve (both high/low pressure valves must be tightly shut). 2 Connect joint of charging hose to vacuum pump. 3 Fully open the handle of Lo manifold valve. 4 Open the vacuum pump for vacuumization. At the beginning, slightly loosen joint nut of low pressure valve to check if there is air coming inside. (If noise of vacuum pump has been changed, the reading of multimeter is 0) Then tighten the nut. 5 Keep vacuuming for more than 15mins and make sure the reading of multi-meter is -1.0 10 5 pa (-76cmHg). 6 Fully open high/low pressure valves. 7 Remove charging hose from charging end of low pressure valve. 8 Tighten lid of low pressure valve. (As shown in below) Multimeter -76cmHg Lo Handle Charging hose Low pressure valve Vacuum pump Manifold Valve Hi handle Charging hose Outdoor Condensate Drainage (only for Heat pump unit) During heating operation, the condensate and defrosting water should be drained out reliably through the drain hose. Install the outdoor drain connector in a 25mm hole on the base plate and attach the drain hose to the connector so that the waste water formed in the outdoor unit can be drained out. The hole diameter 25mm must be plugged. Whether to plug other holes will be determined by the installer according to actual conditions. Drain-water hole Bottom frame Drain plug Drain connecter Hose (available commercially, inner diameter 16mm) Kelvinator Air Conditioning installation instructions 9

Check after installation and operation test Installation and maintenance of HEPA filter Check after installation Items to be checked Has the unit been fixed firmly? Have you done the refrigerant leakage test? Is thermal insulation sufficient? Is water drainage satisfactory? Is the voltage in accordance with the rated voltage marked on the nameplate? Is the electric wiring or piping connection installed correctly and securely? Has the unit been securely earthed? Is the power cord specified? Is the inlet or outlet blocked? Is the length of connection pipes and refrigerant capacity recorded? Possible malfunction The unit may drop, shake or emit noise. It may cause insufficient cooling (heating) It may cause condensation. It may cause water leakage. It may cause electric malfunction or damage the unit. It may cause electric malfunction or damage the parts. It may cause electrical leakage. It may cause electric malfunction or damage the parts. It may cause insufficient cooling (heating) The refrigerant capacity is not accurate. Installation of HEPA Filter 1 Lift up the front panel from the two ends of it, as shown by the arrow direction, and then remove the air filter 2 Attach the HEPA filter onto the air filter Air filter HEPA Air filter filter HEPA filter Air filter 3 Install the air filter properly along the arrow direction in the diagram below, and then close the panel Operation Test 1 Before Operation Test a. Do not switch on power before installation is finished completely. b. Electric wiring must be connected correctly and securely. c. Cut-off valves of the connection pipes should be opened. d. All the impurities such as scraps and waste must be cleared from the unit. 2 Operation Test Method a. Switch on power and press "ON/OFF" button on the remote controller to start the operation. b. Press MODE button to select the COOL, HEAT (Not available with Cooling Only models), FAN to check whether the operation is normal or not. HEPA filter Cleaning and Maintenance Remove the HEPA filter and reinstall it after cleaning according to the installation instruction. Don't use brush or hard things to clean the filter. After cleaning, be sure to dry it in the shade. Service Life The general service life for the HEPA filter is about one year under normal conditions. 10 Kelvinator Air Conditioning installation instructions

Warranty FOR SALES IN AUSTRALIA AND NEW ZEALAND APPLIANCE: kelvinator SPLIT SYSTEM AIR CONDITIONER This document sets out the terms and conditions of the product warranties for Electrolux Appliances. It is an important document. Please keep it with your proof of purchase documents in a safe place for future reference should you require service for your Appliance. 1. In this warranty: (a) acceptable quality as referred to in clause 10 of this warranty has the same meaning referred to in the ACL; (b) ACL means Schedule 2 to the Competition and Consumer Act 2010; (c) Appliance means any Electrolux product purchased by you and accompanied by this document; (d) ASC means Electrolux authorised service centres; (e) Electrolux means Electrolux Home Products Pty Ltd of 163 O Riordan Street, Mascot NSW 2020, ABN 51 004 762 341 in respect of Appliances purchased in Australia and Electrolux (NZ) Limited (collectively Electrolux ) of 3-5 Niall Burgess Road, Mount Wellington, in respect of Appliances purchased in New Zealand; (f) major failure as referred to in clause 10 of this warranty has the same meaning referred to in the ACL and includes a situation when an Appliance cannot be repaired or it is uneconomic for Electrolux, at its discretion, to repair an Appliance during the Warranty Period; (g) Warranty Period means the Appliance is warranted against manufacturing defects in Australia and New Zealand for the period of 60 months, subject to this warranty and to the customer meeting the Warranty Condition. (h) Warranty Condition means: (i) evidence by the customer that the Appliance was installed by a licensed air conditioner installer in Australia and in accordance with Electrolux installation guidelines as set out in the installation manual; (ii) the Appliance rating is correct for the size and thermal characteristics of the room; (iii) the Appliance has been regularly maintained in accordance with Electrolux guidelines set out in the user manual; (iv) the Appliance is designed for providing human comfort and should be used under ambient conditions as set out in the product specifications and general air quality conditions. (i) you means the purchaser of the Appliance not having purchased the Appliance for re-sale, and your has a corresponding meaning. 2. This warranty only applies to Appliances purchased and used in Australia or New Zealand in normal domestic appliactions and is in addition to (and does not exclude, restrict, or modify in any way) any non-excludable statutory warranties in Australia or New Zealand. 3. During the Warranty Period Electrolux or its ASC will, at no extra charge if your Appliance is readily accessible for service, without special equipment and subject to these terms and conditions, repair or replace any parts which it considers to be defective. Electrolux or its ASC may use remanufactured parts to repair your Appliance. You agree that any replaced Appliances or parts become the property of Electrolux. This warranty does not apply to light globes, batteries, filters or similar perishable parts. 4. Parts and Appliances not supplied by Electrolux are not covered by this warranty. 5. To the extent permitted by law, you will bear the cost of transportation, travel and delivery of the Appliance to and from Electrolux or its ASC. If you reside outside of the service area, you will bear the cost of: (a) travel of an authorised representative; (b) transportation and delivery of the Appliance to and from Electrolux or its ASC. In all instances, unless the Appliance is transported by Electrolux or an Electrolux authorised representative, the Appliance is transported at the owner s cost and risk while in transit to and from Electrolux or its ASC. 6. Proof of purchase is required before you can make a claim under this warranty. 7. You may not make a claim under this warranty unless the defect claimed is due to faulty or defective parts or workmanship. Electrolux is not liable in the following situations (which are not exhaustive): (a) the Appliance is damaged by: (i) accident (ii) misuse or abuse, including failure to properly maintain or service (iii) normal wear and tear (iv) power surges, electrical storm damage or incorrect power supply (v) incomplete or improper installation (vi) incorrect, improper or inappropriate operation (vii) insect or vermin infestation (viii) failure to comply with any additional instructions supplied with the Appliance; (b) the Appliance is modified without authority from Electrolux in writing; (c) the Appliance s serial number or warranty seal has been removed or defaced; (d) the Appliance was serviced or repaired by anyone other than Electrolux, an authorised repairer or ASC. 8. This warranty, the contract to which it relates and the relationship between you and Electrolux are governed by the law applicable where the Appliance was purchased. Where the Appliance was purchased in New Zealand for commercial purposes the Consumer Guarantee Act does not apply. 9. To the extent permitted by law and subject to your non-excludable statutory rights and warranties, Electrolux excludes all warranties and liabilities (other than as contained in this document) including liability for any loss or damage whether direct or indirect arising from your purchase, use or non use of the Appliance. 10. For Appliances and services provided by Electrolux in Australia, the Appliances come with a guarantee by Electrolux that cannot be excluded under the ACL. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the Appliance repaired or replaced if the Appliance fails to be of acceptable quality and the failure does not amount to a major failure. The benefits to you given by this warranty are in addition to your other rights and remedies under a law in relation to the Appliances or services to which the warranty relates. 11. At all times during the Warranty Period, Electrolux shall, at its discretion, determine whether repair, replacement or refund will apply if an Appliance has a valid warranty claim applicable to it. 12. For Appliances and services provided by Electrolux in New Zealand, the Appliances come with a guarantee by Electrolux pursuant to the provisions of the Consumer Guarantees Act, the Sale of Goods Act and the Fair Trading Act. 13. To enquire about claiming under this warranty, please follow these steps: (a) carefully check the operating instructions, user manual and the terms of this warranty; (b) have the model and serial number of the Appliance available; (c) have the proof of purchase (e.g. an invoice) available; (d) telephone the numbers shown below. 14. You accept that if you make a warranty claim, Electrolux and its ASC may exchange information in relation to you to enable Electrolux to meet its obligations under this warranty. Important Notice Before calling for service, please ensure that the steps listed in clause 13 above have been followed. FOR SERVICE or to find the address of your nearest state service centre in Australia PlEASE CAll 13 13 49 For the cost of a local call (Australia only) SERVICE AUSTRAlIA ELECTROLUX HOME PRODUCTS www.electrolux.com.au FOR SPARE PARTS or to find the address of your nearest state spare parts centre in Australia PlEASE CAll 13 13 50 For the cost of a local call (Australia only) FOR SERVICE or to find the address of your nearest authorised service centre in New Zealand FREE CAll 0800 10 66 10 (New Zealand only) kssac_warr_aug13 SERVICE NEW ZEAlAND ELECTROLUX (NZ) Limited www.electrolux.co.nz FOR SPARE PARTS or to find the address of your nearest state spare parts centre in New Zealand FREE CAll 0800 10 66 20 (New Zealand only) Kelvinator Air Conditioning warranty 11

If you d like further information about Kelvinator appliances, please visit your retailer, phone or email our Customer Care team or visit our website. telephone: 1300 363 640 fax: 1800 350 067 email: customercare@electrolux.com.au web: kelvinator.com.au Kelvinator. We are part of the Electrolux family. Share more of our thinking at electrolux.com.au 2015 Electrolux Home Products Pty Ltd ABN 51 004 762 341 Print code: Airwave_IM_May15