Fully Flat Cassette Design & Genius in one

Similar documents
Concealed ceiling unit with medium ESP

Concealed ceiling units

Air Conditioning Technical Data FFA-A > FFA25A2VEB > FFA35A2VEB > FFA50A2VEB > FFA60A2VEB

Sky Air. Product catalogue for installers Your business is our concern

Introducing the new Sky Air A-series with ultra-efficient Bluevolution R-32 technology. Our mission Achieve the lowest environmental impact

Sky Air. Product catalogue 2017 for professionals. Get ahead of the competition R-32 IS AN INDUSTRY REVOLUTION. BE PART OF IT.

Air conditioners Heating & Cooling

Heating & Cooling. Air conditioners. M u l t i m o d e l a p p l i c a t i o n. » SEER up to A ++ » Energy efficient heating & cooling

Europe s first light commercial cassette system using R-32 refrigerant. Our mission The lowest environmental impact

FCQH-D8 / RZQ-D3V1/D9V1

Air Conditioners Heating & Cooling

SUPERB TECHNOLOGY FOR SUPERB INTERIORS

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-C

technical data air conditioning systems Indoor Units FCQ-C8VEB

VRV IV heat recovery Best efficiency and comfort solution

Water cooled VRV IV W-series

VRV IV S-series heat pump

usiness concern our Sky air product range commercial catalogue Preliminary version

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Air Conditioners Heating & Cooling

usiness concern our SKY AIR PRODUCT RANGE COMMERCIAL CATALOGUE

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

usiness concern our Sky air product range commercial catalogue

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FDQ-B

VRV IV i-series heat pump

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioners Heating & Cooling

Air Conditioning Systems

Air conditioners Heating & Cooling

Daikin leads the way:

Air Conditioners Heating & Cooling

High temperature hydrobox for VRV

Keep looking you ll never find me. VRV IV heat pumps for indoor installation

Air Conditioners Heating & Cooling

Replacement VRV Quick & quality replacement for R-22 and R-407C systems

Air Conditioning. Technical Data. 4-way blow ceiling mounted cassette EEDEN ACQ-C

Heating High/Nom./Low dba 36/33/29 44/39/33 45/41/35 45/41/37 Refrigerant Type R-410A Piping

Air conditioners Heating & Cooling

Infrastructure cooling solution

where innovation meets creativity

Air Conditioners Heating & Cooling

Air conditioners Heating & Cooling

Designed. forcolder. climates. Residential & light commercial catalogue. Optimal climate control

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Daikin air conditioners for shops, restaurant and offices

Air Conditioning Technical Data FAA-A > FAA71AUVEB > FAA100AUVEB

Prices and technical information for Sky Air products. Pricelist Sky Air A-series

For Residential & Light Commercial Applications. 4 Ton 8 Zone Multi Split Heat Pump System

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

Air Conditioning. Technical Data. Concealed ceiling unit EEDEN FDXM-F

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Daikin Sensira. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data. Wall mounted unit EEDEN FTXG-JW

Daikin offers the widest range in DX ventilation in the market. With a variety of ventilation solutions from small heat recovery ventilation to large

Air Conditioning. Technical Data. Multi model application EEDEN MXS-E

VRV The total solution. Integrated Climate Control

Air conditioners, heating & cooling for shops,restaurants and offices

Just feel well. 2017/2018 Air conditioning

Air conditioners Heating & Cooling

Air Conditioners. Technical Data FBQ-C

Remote control infrared ARC433B76 ARC433A8 ARC433B69

Designed. colder climates. for AIR TO AIR HEAT PUMPS FTXS K FTXS-20-25K

Ventilation Product catalogue 2017 for professionals

Air Conditioning. Technical Data. Small concealed ceiling unit EEDEN FDBQ-B

Daikin Sensira R-32. Refreshingly new. Discreet wall mounted unit providing high efficiency and comfort

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Air Conditioners Technical Data

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data EEDEN RZQSG-L(8)Y1

OUTDOOR UNITS Air-Cooled VRV REYQ8-48P8Y1B 128 RXYQ5-54P7W1B(A) 130 RXYQ16-36P7W1B 132 RXYSQ4-6PA7Y1B 133 RXYSQ4-6PA7V1B 134 RXQ5-18P7W1B(A) 135

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data EEDEN AZQS-BV1

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

Ventilation. Product catalogue 2019 for professionals

Pure comfort & design

Air Conditioning. Technical Data. Flexi type unit EEDEN FLXS-B(9)

Including mounting plate. General Rating Nameplate. Terminal strip with earth terminal

USER MANUAL. Fan coil units FWC06B7TV1B FWC07B7TV1B FWC08B7TV1B FWC09B7TV1B FWC06B7FV1B FWC07B7FV1B FWC08B7FV1B FWC09B7FV1B. Cover Cover.

QUALITAIR PACKAGED SYSTEMS & APPLIED CHILLED WATER PRODUCTS. Fan Coil Units. QCeiling Cassettes. Floor Standing Units

LV Series. SEER 15+ Concealed Built in Heat Pump

Innovative air conditioning

Daikin MXS SERIES MULTI-ZONE HEATING & COOLING SYSTEMS

technical data air conditioning systems Indoor Units FBQ-C7VEB

EDUS D Engineering Data. Design Manual RWEQ-TATJU, 208 / 230 V RWEQ-TAYDU, 460 V RWEQ-TAYCU, 575 V. Heat Pump 60 Hz Heat Recovery 60 Hz

Daikin air conditioners for your home, shops, restaurants and offices

MULTI SYSTEM SHOPS RESTAURANTS SMALL OFFICES COMMERCIAL MULTI SYSTEM.

MOV75984_EPCE02-18 Page 1 8-OCT-02 S Y S T E M S

DX AIR CURTAIN. SensAir

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

Air Conditioners. Technical Data FTXS-G

Air Conditioning. Technical Data EEDEN RXS-F8

Ceiling suspended unit. Indoor units * FHQG71C * FHQG100C * FHQG125C * FHQG140C Cooling capacity Min./Nom./Max. kw

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

Condensing Units CUS 15-60

Transcription:

ARGUE CARDS Fully Flat Cassette Design & Genius in one Why choose fully flat cassette Unique design in the market that integrates fully flat into the ceiling Advanced technology and top efficiency combined Most quiet cassette available on the market Benefits for the installer Unique product in the market! Most quiet unit (25dBA) The user-friendly remote control, available in several languages, enables the easy set-up of sensor option and control of the individual flap position Meeting European design taste. FFQ-C / FXZQ-A Benefits for the consultant Unique product in the market! Blends seamlessly in any modern office interior design Ideal product to improve BREEAM score/epbd in combination with Sky Air Seasonal Smart (FFQ-C) or VRV IV heat pump units (FXZQ-A). Benefits for the end user Engineering excellence and unique design in one Most quiet unit (25dBA) Perfect working conditions: no more cold draughts Save up to 27% on your energy bill thanks to the optional sensors Flexible usage of space and suits any room configuration thanks to individual flap control User-friendly remote control, available in several languages. Choice between grey or white panel 136

Unique design Designed by a European design office to fully meet the European taste. Fully flat into the ceiling, leaving only 8mm. Fully integrated in the one ceiling tile, enabling lights, speakers and sprinklers to be installed in adjoining ceiling tiles. Decoration panel available in 2 colours (white and white-silver). Differentiating in technology Optional presence sensor When the room is empty, it can adjust the set temperature or switch off the unit saving energy. When people are detected, the direction of the airflow is adapted to avoid cold draughts being directed towards occupants. Optional floor sensor Detects the temperature difference and re-directs the airflow to ensure even temperature distribution. Top efficiency * Seasonal labels up to A + + When the room is empty, the sensor option can adjust the set temperature or switch off the unit saving up to 27% energy. * for FFQ25,35C in combination with RXS25,35L3 Other benefits Individual flap control: easily control one or more flaps via the wired remote controller (BRC1E*) when rearranging the room. When fully closing or blocking the flaps, the option Sealing member of air discharge outlet is needed. Most silent cassette in the market (25dBA), important for office applications. Marketing tools www.daikineurope.com/fullyflat www.youtube.com/daikineurope 137

138 FULLY FLAT CASSETTE INTEGRATES FULLY FLAT INTO THE CEILING

FXZQ-A Fully flat cassette Unique design in the market that integrates fully flat into the ceiling Fully flat integration in standard architectural ceiling tiles, leaving only 8mm Remarkable blend of iconic design and engineering excellence with an elegant finish in white or a combination of silver and white Two optional intelligent sensors improve energy efficiency and comfort. 15 class unit especially developed for small or well-insulated rooms, such as hotel bedrooms, small offices, etc. Individual flap control: flexibility to suit every room layout without changing the location of the unit! FXZQ-A BRC1E53A-B-C BRC7F530W-S Reduced energy consumption thanks to specially developed small tube heat exchanger, DC fan motor and drain pump Optional fresh air intake Standard drain pump with 630mm lift increases flexibility and installation speed 500 mm Indoor unit FXZQ 15A 20A 25A 32A 40A 50A Cooling capacity Nom. kw 1.7 2.2 2.8 3.6 4.5 5.6 Heating capacity Nom. kw 1.9 2.5 3.2 4.0 5.0 6.3 Power input - 50Hz Cooling Nom. kw 0.043 0.045 0.059 0.092 Heating Nom. kw 0.036 0.038 0.053 0.086 Dimensions Unit Height mm 260 Width mm 575 Depth mm 575 Weight Unit kg 15.5 16.5 18.5 Casing Material Galvanised steel plate Decoration panel Model BYFQ60CW White (N9.5) Dimensions HeightxWidthxDepth mm 46x620x620 Weight kg 2.8 Decoration panel 2 Model BYFQ60CS White (N9.5) + Silver Dimensions HeightxWidthxDepth mm 46x620x620 Weight kg 2.8 Decoration panel 3 Model BYFQ60B3W1 White (RAL9010) Dimensions HeightxWidthxDepth mm 55x700x700 Weight kg 2.7 Fan-Air flow rate - 50Hz Cooling High/Nom./Low m³/min 8.5/7/6.5 8.7/7.5/6.5 9/8/6.5 10/8.5/7 11.5/9.5/8 14.5/12.5/10 Heating High/Nom./Low m³/min 8.5/7/6.5 8.7/7.5/6.5 9/8/6.5 10/8.5/7 11.5/9.5/8 14.5/12.5/10 Air filter Type Resin net with mold resistance Sound power level Cooling High/Nom. dba 49/- 50/- 51/- 54/- 60/- Sound pressure level Cooling High/Nom./Low dba 31.5/28/25.5 32/29.5/25.5 33/30/25.5 33.5/30/26 37/32/28 43/40/33 Heating High/Nom./Low dba 31.5/28/25.5 32/29.5/25.5 33/30/25.5 33.5/30/26 37/32/28 43/40/33 Refrigerant Type R-410A GWP 2,087.5 Piping connections Liquid OD mm 6.35 Gas OD mm 12.7 Drain VP20 (I.D. 20/O.D. 26) Power supply Phase/Frequency/Voltage Hz/V 1~/50/220-240 Current - 50Hz Maximum fuse amps (MFA) A 16 Control systems Infrared remote control BRC7F530W (white panel) / BRC7F530S (grey panel) / BRC7EB530W (standard panel) Wired remote control BRC1E53A / BRC1E53B / BRC1E53C / BRC1D52 Simplified wired remote control for hotel applications BRC2E52C (heat recovery type) / BRC3E52C (heat pump type) (1) Dimensions do not include control box 139

Detailed technical drawings VIEW ALL FXZQ-A TECHNICAL DRAWINGS ON MY.DAIKIN.EU FXZQ-A NEW PANEL BYFQ60C2W1W BYFQ60C2W1S Fresh white N9.5 Daikin Silver 300 or less 585-595 (Ceiling opening space) 533 (Suspension position) Pipe connection side Service access panel 450x450mm or more Drain connection side A Arrow view Note) 2. 533 (Suspension position) 585-595 (Ceiling opening space) 4-M4 Hole Outdoor air intake (direct connection) B Arrow view Required space C Arrow view Adjustable (0-630) When the discharge grill is closed, the required space is 200mm or more 1 Liquid piping connection ø 6.4 Flare connection Suspension bolt 10 or less Notes: 1. Sticking locations for manufacturer`s label Manufacturer`s label for indoor unit: on the bell mouth inside suction grille. Manufacturer`s label for decoration panel: on the inner frame inside suction grille. 2. In case of using infrared remote controller, this position will be a signal receiver. Refer tot the drawing of infrared remote controller in detail. 3. When the temperature and humidity in the ceiling exceed 30ºC and RH 80%, or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more, Glasswool or polyethylene foam) is required. 4. Though the installation is acceptable up to maximum of 595mm square ceiling opening, keep the clearance of 10mm or less between the main unit and the ceiling opening so that the panel overlap allowance can be ensured. 10 or less Note ) 4. 300 mm or more Required space From the floor 2500 or more For height installation 2 Gas piping connection ø 12.7 Flare connection 3 Drain piping connection VP20 (O.D. ø 26) 4 Power supply connection 5 Remote control code and wiring connection 6 Air discharge grille 7 Suction grill 8 Drain hose (accessory) I.D. ø 25 Outlet 3D082052 FXZQ-A OLD PANEL Decoration panel 300 or less 585-660 (Ceiling opening space) 533 (Suspension posotion) Pipe connection side Service access panel 450x450mm or more Drain connection side Note) 2. A Arrow view 533 (Suspension posotion) 585-660 (Ceiling opening space) 4-M4 Hole Outdoor air intake (direct connection) B Arrow view Required space C Arrow view Adjustable (0-645) 295 mm or more When the discharge grill is closed, the required space is 200mm or more 1 Liquid piping connection ø 6.4 Flare connection 2 Gas piping connection ø 12.7 Flare connection 3 Drain piping connection VP20 (O.D. ø 26) 4 Power supply connection 5 Remote control code and wiring connection 6 Air discharge grille 7 Suction grill 8 Drain hose (accessory) I.D. ø 25 Outlet Suspension bolt 45 or less 45 or less Note ) 4. Notes: 1. Sticking locations for manufacturer s label Manufacturer s label for indoor unit: on the bell mouth inside suction grille. Manufacturer s label for decoration panel: on the inner frame inside suction grille. 2. In case of using infrared remote controller, this position will be a signal receiver. Refer tot the drawing of infrared remote controller in detail. 3. When the temperature and humidity in the ceiling exceed 30ºC and RH 80%, or the fresh air is inducted into the ceiling or the unit continues 24 hour operation, an additional insulation (thickness 10mm or more, Glasswool or polyethylene foam) is required. 4. Though the installation is acceptable up to maximum of 660mm square ceiling opening, keep the clearance of 45 mm or less between the main unit and the ceiling opening so that the panel overlap allowance can be ensured. Required space From the floor 2500 or more For height installation 3D082161A 140