PASCOE S PTY LTD. EMERGENCY RESPONSE MANUAL & P.I.R.M.P (Public) SOP 529 (Public) Site Address:

Similar documents
PASCOE S PTY LTD EMERGENCY RESPONSE MANUAL. (Public Version) SOP 517. July 2015

PASCOE S PTY LTD EMERGENCY RESPONSE MANUAL. (Public Version) SOP 531. July 2015

PASCOE S PTY LTD EMERGENCY PLAN JULY 2015

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

Steritech Pty Ltd. Pollution Incident Response Management Plan (PIRMP) WETHERILL PARK Environment Protection Licence No

Pollution Incident Response Management Plan

Steritech Wetherill Park Pollution Incident Response Management Plan (PIRMP) Steritech Pty Ltd. Pollution Incident Response Management Plan (PIRMP)

Pollution Incident Response Management Plan

Sydney Ship Repair & Engineering Pty Ltd. Emergency Pollution Incident Response Management Plan

Emergency. Management. Emergency. Readiness Checklist

POLLUTION INCIDENT RESPOSE MANAGEMENT PLAN MIROTONE CHIPPING NORTON UPDATED 28 th MARCH 2018 BY JOHN DAVEY

University of Maryland FIRE EVACUATION PLAN Columbus Center POLICE FIRE MEDICAL EMERGENCY - 911

Mulch fires, trash can fires, or other fire outside a building should be reported by the following methods:

IYRS School of Technology & Trades RCRA CONTINGENCY PLAN Bristol Facility 40 CFR 265 Subpart D 29 CFR Emergency Evacuation

ABN Solveco Pty Ltd 38 Links Road, St. Marys NSW 2760 Telephone: (02) Fax: (02)

FIRE AND EVACUATION PLAN

University of Maryland FIRE EVACUATION PLAN NATIONAL DENTAL MUSEUM POLICE FIRE MEDICAL EMERGENCY Anyone discovering excessive heat,

Emergency Control Procedure Coffs Harbour Site

FIRE EVACUATION PLAN PRATT STREET PARKING GARAGE AND ATHLETIC CENTER POLICE FIRE MEDICAL EMERGENCY

Date Issued: December 14, 2017 Revision: 2.1

Fire Safety Procedures and Associated Training

Emergency Management Plan

El Segundo Fire Department. Unified Program (UP) Form CONSOLIDATED CONTINGENCY PLAN I. FACILITY IDENTIFICATION

CONTRACTOR GUIDELINES

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

LESSEE EMERGENCY RESPONSE PLAN AFAS Live

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

KVP Policy QA2.6 Quality Area 2 Issue date: July 2017

5.0 CONTINGENCY PLAN. It is necessary to amend the plan if:

FIRE SAFETY MANAGEMENT PLANS DEVELOPMENT GUIDE A GUIDE TO DEVELOPING

Banff Mineral Springs Hospital EMERGENCY RESPONSE CODE RED Fire

5 Key Stages to Risk Assessment

EMERGENCY PREPAREDNESS & RESPONSE PROCEDURE

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM

H&S Forum. Fire Safety Policy Glascote Academy

University of Maryland FIRE EVACUATION PLAN

FIRE SAFETY POLICY and FIRE SAFETY ARRANGMENTS

Fire Safety Policy & Fire Safety Management System Version October 2013 Emergency Evacuation Procedures

Fire Safety Management

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM

WARDEN TRAINING AT QUT

WORKPLACE INSPECTION CHECKLIST FOR LABORATORY ENVIRONMENTS

Fire Safety Policy. Signed Date September on behalf of the Management Committee. on behalf of The Woodlands

Bishopstone Village Hall Health and Safety and Fire Evacuation Policy

CURTIN UNIVERSITY PROJECT DELIVERY GUIDELINES

HAZARDOUS MATERIALS/WASTE EMERGENCY CONTINGENCY PLAN University of Southern Maine Portland Campus

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

NATIONAL COMPETENCY STANDARD

Sir Christopher Hatton Academy A Member of Hatton Academies Trust

FACILITY OF EMERGENCY PLAN. (Template)

Health and Safety Services. Safety Guide 5. Fire drills

EMERGENCY RESPONSE GUIDELINES

Policy Statement Emergencies Emergency Equipment and Facilities

EMERGENCY ACTION PLAN GOLDEN CITY CASINO HIGHWAY 162 OROVILLE, CALIFORNIA

EMERGENCY EVACUATION PROCEDURE Temporary Instructions w.e.f 5 th September 2018

Emergency Action Plan

Driver Resource Manual Unit 6 Emergency Evacuation

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Emergency Response Plan

SAGU AMERICAN INDIAN COLLEGE 2018 ANNUAL FIRE SAFETY REPORT INCLUDING STATISTICS FOR THE 2017 CALENDAR YEAR PREPARED BY:

These telephone numbers are provided as a general aid to emergency notification. Be advised that additional agencies may be required to be notified.

Contractor Worksheet Underground Fires Major Hazard Standard

GREAT DENHAM PRIMARY SCHOOL FIRE SAFETY POLICY September 2017

Excel English. Health & Safety Policy

HORNCASTLE ARENA 55 JACK HINTON DRIVE CHRISTCHURCH

Venue Emergency Response Plan (VERP)

Emergency Evacuation or Lockdown

NARNIA CHRISTIAN PRE-SCHOOL AND EARLY CHILDHOOD CENTRE

HUDSON VALLEY COMMUNITY COLLEGE BUILDING EMERGENCY ACTION PLAN FOR OUTSIDE EMERGENCY ASSISTANCE: DIAL 911 TO REACH THE SARATOGA CTY POLICE & FIRE

Upon activation of the building fire alarm system or verbal command to evacuate a building: All personnel shall evacuate the building immediately.

Evacuation and Lockdown Plan

Fire Safety Policy. Billy Hanafin H & S and Operations Officer. Fife Cultural Trust. Version 1.0 October 2013 Page 1

Fire Safety and Emergency Evacuation. Herne Bay Junior School. Compassion Courage Hope Integrity Justice Respect Responsibility - Wisdom

7 Hazard assessment 8 Worker participation 9 Hazard elimination and control

Fire Safety Plan Training 2017

Fire Safety Policy and Procedures

Grossmont Cuyamaca Community College District Fire Report 2014

Event Management CHECKLIST

Cowal Gold Operations Emergency Response Plan

NOTTINGHAM CITY HOMES

Kaufert Laboratory Building Emergency Plan

This plan, its contents, and emergency notification procedures shall be made available to all appropriate university employees.

TULANE UNIVERSITY EMERGENCY ACTION PLAN

Department of Biological Sciences National University of Singapore. 4. Procedures: ACTIONS TO BE TAKEN IN THE EVENT OF FIRE DURING OFFICE HOURS

Local Rules: Fire Safety

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va

Ref : NTU/OHS/SOP/06.2 Date of issue : 24 July Updated by : Wong Zhi Hao Next review date : 23 July 2014

Project: Location: Date Prepared: Last Reviewed:

South Australian Regulatory Requirements

Universiti Tunku Abdul Rahman STANDARD OPERATING PROCEDURES

Stationers Crown Woods Academy. Evacuation Chair. Policy

Fire and Evacuation Guide

SEQMS Procedure. Pollution Incident Reponse Plan Bituminous Products Revesby Plant BP REV PL_PIRMP

HAZARDOUS WASTE CONTINGENCY PLAN

FIRE SAFETY PLAN Revised December

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

Evacuation Procedures For

CLYST ST. MARY VILLAGE HALL

Fire and Bomb. Evacuation Policy

EMERGENCY PLAN FOR: REDOX PTY LTD 2 SWETTENHAM ROAD MINTO NSW 2566

Transcription:

PASCOE S PTY LTD EMERGENCY RESPONSE MANUAL & P.I.R.M.P (Public) (Incorporating) Pollution Incident Response Management Plan SOP 529 (Public) Revision Date: October 2014 Site Address: 14 GARLING ROAD KINGS PARK, NSW 2148 TELEPHONE: 02 8774 4700 FACSIMILE: 02 9632 1924 Web Address: www.pascoes.com.au Page 1 of 10

Document Control Authorised By Position Date Mark Keith Technical Manager 1/11/2014 Mark Williams Sydney Operations Manager 1/11/2014 Record of Revisions Revision no. Date Revised by Description 1 1a 2 3 4. 5. 6 7 8 Nov 2013 Mar 2014 Oct 2014 M Keith M Keith K Baker New Issue Add Public version v1public Pascoes Kings Park facility imminent closure Page 2 of 10

TABLE OF CONTENTS 1.0 FACILITY DETAILS and OBJECTIVES... 3 2.0 DEFINITIONS... 4 3.0 EMERGENCY RESPONSE... 4 3.1 INTERNAL EMERGENCY CONTACT NUMBER... 4 3.2 EXTERNAL EMERGENCY CONTACT NUMBERS... 4 3.3 NEIGHBOUR CONTACT NUMBERS... 5 3.4 FACILITY OPERATIONS CENTRE (FOC)... 5 3.5 ALTERNATIVE FACILITY OPERATIONS CENTRE (FOC)... 5 3.6 ALARM INITIATION... 6 3.7 WASTE WATERS, STORM WATER AND FIRE DELUGE RUN OFF... 6 3.8 NOTIFICATION OF AUTHORITIES... 6 4.0 TERMINATION OF EMERGENCY & DEBRIEF... 7 5.0 INCIDENT REPORTING & INVESTIGATION... 7 6.0 EXERCISES, TRAINING AND REVIEW... 7 6.1 TRAINING PROGRAM... 7 6.2 EXERCISES... 7 6.3 REVIEW OF EMERGENCY PLAN... 7 APPENDIX 3a SITE MAP... 8 APPENDIX 3b LOCATION MAP Pascoe s / Pascom... 9 APPENDIX 4: FLOW CHART - RESPOSE TO MAJOR SPILL... 10 1.0 FACILITY DETAILS and OBJECTIVES This plan provides for the Emergency Responses and the management of pollution incidents that may occur at Pascoe's Pty Ltd at 14 Garling Road, Kings Park, NSW 2148. The objectives of this plan, in the event of an emergency, are: 1. To protect people, including, neighbours and emergency response crews. 2. To stabilise any emergency situations. 3. To minimise damage to people, property and the environment. 4. To make available an emergency plan for Dangerous Goods as detailed in Schedule 5 of the OH&S Regulations 5. To provide a mechanism to notify key personnel, neighbours, and emergency services 6. To make available adequate information to emergency services 7. To deploy evacuation procedures. 8. To help prevent future emergencies. 9. To enable Emergency staff to deal safely with identified emergencies. Page 3 of 10

2.0 DEFINITIONS SES State Emergency Services PPE Personnel Protective Equipment EPA Environmental Protection Authority NSW POELA Protection of the Environment Legislation Amendment Act 2011 POEO Protection of the Environment Operations Act DG s Dangerous Goods as per DG License NDG 023198 DECCW Department Environment, Climate Change & Water (now OEH) OEH Office of Environment & Heritage FOC Facility Operations Centre 3.0 EMERGENCY RESPONSE Various classes of dangerous and harmful (to the environment) goods are stored on site. Different hazards are associated with storage and handling of the various classes of dangerous goods. 3.1 INTERNAL EMERGENCY CONTACT NUMBER Operations Manager Fairfield Plant (FACILITY EMERGENCY CONTROLLER) Maintenance Supervisor Fairfield Plant (FACILITY EMERGENCY CONTROLLER ALTERNATE) Mark Williams Bus (02) 8774 4716 Mobile 0401 345 393 Chris Cause Bus (02) 8774 4729 Mobile 0421 835 879 3.2 EXTERNAL EMERGENCY CONTACT NUMBERS Fire and Rescue 000 - Blacktown 02 9622 8932 Ambulance 000 Police 000 - Blacktown 02 9671 9199 Pollution Incident Follow order listed (as per notification protocol Environment & Heritage 22 March 2012) Waste Removal Company The Hungry Giant a) Dial 000 if major incident b) EPA NSW 131 555 c) Blacktown Council 02 9839 6000 d) Work Cover Authority 13 10 50 e) Fire and Rescue NSW 000 1300 101 522 Page 4 of 10

3.3 NEIGHBOUR CONTACT NUMBERS Name / Organisation Address / Location Telephone Number Ultimate Flooring Systems 42/24 Garling Road 9676 8360 HPA Hydraulic Pumps Australia 40/24 Garling Road 9676 7355 GPD Gear Pump Distributers 41/24 Garling Road 9676 7311 / 9676 7322 The Blind Factory (NSW) 38/24 Garling Road 9680 2152 Australian Urethane & Styrene 25 Garling Road 9676 8444 Freight Refrigerated Transport 16/12 Garling Road 8809 3855 Accord Engineering 5/16 Garling Road 9621 5999 Inala Industries 1/16 Garling Road (downstairs) Peter Burger 1/16 Garling Road (upstairs) VB s Tile Decors 6/12 Garling Road 9676 2244 Sydney Drive Shaft 5/12 Garling Road 0404 050 766 Motac Fab & Maintenance 5/12 Garling Road 0433 154 253 Brightweld 31-32/24 Garling Road 9676 7719 All Style Joinery 29/24 Garling Road 0402 417 383 Walkerden Golf 28/24 Garling Road 9621 8186 Office National 24/24 Garling Road 9674 2999 Judd Trucks 3/22 Garling Road 9622 1074 Stanvic Engineering 1/22 Garling Road 9671 5255 ACT Refrigeration 2/20 Garling Road 0418 236 452 Aussie Forklift Repairs 1/20 Garling Road 9679 8992 Sydney Towbars 1/12 Garling Road 9671 2330 Peter s Lunch Shop 20 Garling Road 9621 5819 3.4 FACILITY OPERATIONS CENTRE (FOC) The Garling Road nature strip adjacent to office entrance area is designated as the FOC (Facility Operations Centre) for co-ordinating the emergency response activities, though the ALTERNATE FOC is the best suitable under the current circumstances. 3.5 ALTERNATIVE FACILITY OPERATIONS CENTRE (AFOC) If the primary FOC is unavailable, a mobile phone set up is prescribed from the Facility Emergency Controller s vehicle, which is to be located in a safe area upwind and at least 20-30 metres from the main gate. A copy of the Emergency Plan is to be kept in the Facility Emergency Controller & alternate s vehicle at all times. Page 5 of 10

3.6 ALARM INITIATION The alarm is initiated by any employee/contractor/person at the site upon witnessing an event, that would result in Harm to PEOPLE, PROPERTY or the ENVIRONMENT or the activation of the automatic Alarm System. Manual alarm activation can be initiated by activating one of the 4x SITE EMERGENCY ALARMS In the front office corridor adjacent to the vacated laboratory External site on wall in the old Processing area, behind the disused Gassing Room No.3 Outside the vacated Production Office/First Aid Room & at the centre of the Production area, on the end of the 4 th Packaging storage rack. The person who initiates the alarm shall notify the Facility Emergency Controller or alternate stating: 1. What is the nature of the emergency 2. Where is the incident occurring 3. What immediate assistance is required, e.g. Spill response, first aid, ambulance, etc. Note: Initial Actions Are Extremely Important. Eg a small fire that can become a major blaze, may readily be put out by IMMEDIATE action, if considered safe to do so. At ALL times though, personal safety outweighing property loss, MUST be considered. 3.7 WASTE WATERS, STORM WATER AND FIRE DELUGE RUN OFF Though the site is shutting down it can generate waste waters from the following areas that need to be contained as routine wastewaters and exceptional event run offs that could result in pollutants entering the stormwater or sewerage systems. Internally generated waste for treatment or disposal Storm water contaminated Fire deluge system containment On site waste for Licensed Contractor removal Note: in case of any major spill- the Storm Water Isolation Valves must be closed - as a first action 3.8 NOTIFICATION OF AUTHORITIES The Facility Emergency Controller or alternate, is to contact Emergency Services and advise the following details - Nature of emergency - spill, fire, etc. - Chemicals, if any, involved in the incident - The location on site, of the incident, ensuring a Site & Emergency Plan is available. - Seek advice on evacuation, closing roads, etc. Page 6 of 10

4.0 TERMINATION OF EMERGENCY & DEBRIEF To be conducted by the Facility Emergency Controller, or alternate, when the incident is considered under control, at which time the Emergency Alarm is turned off, to indicate the all is clear. Debrief with involved Emergency response parties, is to include: 1. Investigating the lead up to the incident 2. Discussion on effectiveness of emergency actions 3. Discussion on any possible contamination 4. Discussion on allocation of costs and funding coverage 5. Recommendations to be put in place 5.0 INCIDENT REPORTING & INVESTIGATION All incidents must be reported to the Facility Emergency Controller or alternate, who shall conduct an incident investigation. Outcome of the investigation shall be communicated, as required by the relevant authorities & to the Business. For major incidents, the Facility Emergency Controller or alternate shall inform the Duty officer of the EPA, who may request a written report. 6.0 EXERCISES, TRAINING AND REVIEW 6.1 TRAINING PROGRAM Pascoe s will ensure that Operation s Management personnel are accustomed to their responsibilities of the Emergency Response Plan, including their appointed Contractors/sub-contractors, employed for specific on-site tasks by: 1. Being issued with a copy of the Emergency Plan and subsequent updates. 2. Acknowledging any identified Risks associated with the site 3. Being familiar with the location of telephones, fire hoses, portable extinguishers and the Storm Water isolation valves as required. 4. Participating in at least in 1x yearly & random Emergency drill. 5. Having training records kept by the QA Manager and to include: o The manner in which testing was conducted and maintained o The dates on which they have been conducted & o The names of staff members who participated &/or carried out the testing 6.2 EXERCISES Note: Plans must be retested within one month of any incident Documented training exercises to be carried out on a suitable day, as decided by the Facility Emergency Controller, or alternate at a MINIMUM annually. Training records are kept by the QA Manager in the training log. 6.3 REVIEW OF EMERGENCY PLAN Once a year, plus when requested if & when circumstances change.. Page 7 of 10

APPENDIX 3a SITE MAP Pascoes Kings Park Emergency Evacuation Plan Finished Goods Storage Sprinkler Booster System effluent tank chemical storage drums - bunded area treatment capacity = 26,000 lt capacity = 40,000 capacity = 20,000 lt lt propellant gas storage tanks capacity = 95,000 lt dispensing underground storage tanks capacity = 120,000 lt Hot rooms mixing mixing Gas Gas Gas Rm 2 Rm 3 Rm 4 Aerosol Fill Area BUILDING 16 boiler Prod. office Finished Goods Storage Packaging Storage Office hall way 1 2 3 4 packaging storage racks packaging storage office hall way reception Emergency Assembly point GARLING ROAD Work shop Legend Fire Extinguisher Emergency evacuation route First Aid cabinet Stretcher Emergency Alarm activation button Stairway Hydrant Fire hose LPG emergency shutoff button lab LPG cylinders Liquid Fill Area Air Compressors x 2 Gas Rm 5 Upon hearing the Evacuation alarm 1. Switch off any operating electrical, heating or gas equipment, provided it safe to do so. 2. Make your way to the Emergency Assembly point in front of #16 Garling Rd main entry doors via the nearest evacuation route & exit. 3. Inform the Facility Emergency Controller or alternate (Operations Manager Fairfield or the Maintenance Supervisor Fairfield). with any information you may have regarding the emergency including whether anyone is trapped. 4. Remain at the emergency assembly point until otherwise directed by the Facility Emergency Controller or a member of the Emergency services. This Site Plan is not drawn to scale Page 8 of 10

Emergency Plan Issue/Revision Date: Oct 2014 APPENDIX 3b LOCATION MAP Pascoe s Address: Pascoe s 14 Garling Road, KINGS PARK NSW 2148 Marked as X in map centre Storm Water Discharge Location: Eastern Creek Page 9 of 10

Emergency Plan Issue/Revision Date: Oct 2014 APPENDIX 4: FLOW CHART: RESPONSE TO MAJOR SPILL Page 10 of 10