Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

Similar documents
Product Data. Split System Heat Pump

Product Data. Split System Heat Pump 4TWR4018G1000A 4TWR4024G1000A 4TWR4030G1000A 4TWR4036G1000A 4TWR4042G1000A 4TWR4048G1000A 4TWR4060G1000A

Product Data Split System Cooling

Product Data. Split System Cooling H-EN. January 2017

Product Data. Split System Cooling D-EN. August 2016

Product Data. Split System Cooling E-EN. November 2016

Product Data. Split System Heat Pump A-EN. March 2016

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Product Data. Split System Cooling A. November 2013

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Heat Pump Product & Performance Data

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Cooling Product Data

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

Split System Cooling Product Data

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Cooling Product & Performance Data

Split System Cooling Product Data

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

Split System Heat Pump Product Data

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Split System Cooling Product & Performance Data

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Appendix J Noise Appendix

7/8 NO NO NO PROPELLER DIRECT / /230/1/ SPINE FIN /8 8 LBS., 0 OZ. YES 7/8 3/8

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTB6-SF-3. Split System Cooling 4TTB6048A1000A, 4TTB6049A1000A CAUTION

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6024-SF-1B. Split System Cooling 4TTR6024A1000B CAUTION CAUTION WARNING

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Hyperion TM Split Systems

4TTR6036B1000A 208/230/1/ CLIMATUFF - SCROLL 3/4 3/4 3/4 3/4 3/4 208/230/1/ NO YES NO PROPELLER DIRECT

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTR6048-SF-1A. Split System Cooling 4TTR6048A1000A CAUTION CAUTION WARNING

4A6H5042G1000A 208/230/1/ DURATION - SCROLL 3/4 208/230/1/ NO (Use BAYKSKT263) YES YES PROPELLER DIRECT

4A6H5049E1000B 208/230/1/ /8 7/8 7/8 7/8 DURATION 208/230/1/ /230/1/ SPINE FIN 13 LBS., 10 OZ. YES

Illusion Split System

208/230/1/60 5/8 5/8 5/8 5/8 5/8 20 CLIMATUFF /230/1/

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

Split System Cooling Product Data XB 1000

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Service Facts. Split System Heat Pump 4A6H5019H-SF-1C-EN. August A6H5019H1000A

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

R4H4. Product Specifications

R4H4. Product Specifications

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

WCH5**4. Product Specifications

TruComfort Variable Speed Cooling Single Phase 2-5 Tons

Product Catalog Split System Air Conditioners Odyssey

Split System Heat Pump Product Data

TECHNICAL SPECIFICATIONS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

MACH N-407 Heat Pump Air-Cooled Chiller

N4H4. Product Specifications

MAC N-407 Air-Cooled Chiller

36,000-62,000 BTUH Nominal Capacity

TECHNICAL SPECIFICATIONS

Cooling/Heat Pump Convertible Air Handlers

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

N4A6. Product Specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

2 shp 13 lc 1 36 t - 1 a

Variable Speed Convertible Air Handler 2 1/2 Ton

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Commercial High-Efficiency Condensing Units

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Commercial High-Efficiency Condensing Units

Cooling/Heat Pump Convertible Air Handlers

Variable Speed Convertible Air Handler 4 Ton

Cooling/Heat Pump Convertible Air Handlers

Variable Speed Convertible Air Handler 5 Ton

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

Transcription:

Product Data Side Discharge AC Models For coastal applications where units are installed within one (1) mile of salt water, epoxy coated models are recommended. These models have an 8 week lead time after order. 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A EpoxyCoated Model 4TTL6018A1COTA 4TTL6024A1COTA 4TTL6030A1COTA 4TTL6036A1COTA 4TTL6042A1COTA 4TTL6048A1COTA 4TTL6060A1COTA Note: Graphics in this document are for representation only. Actual model may differ in appearance. January 2018 22-1931-1D-EN

Table of Contents OutlineDrawing... 3 SoundPowerLevel Table... 4 ProductSpecifications... 5 AccessoryDescriptionandUsage... 7 ModelNomenclature... 7 Wiring... 8 MechanicalSpecification Options... 12 2 22-1931-1D-EN

Outline Drawing FIGURE 2 3/4 P02 = 26.75 (Base 3.3) P03 = 32.75 (Base 4.3) P04 = 32.75 (Base 4.4) 7.5 2.75 DWG. D159818_rev a Model Base A B C D E F G H J 4TTL6018A 3.3 4TTL6024A 3.3 4TTL6030A 3.3 4TTL6036A 4.3 4TTL6042A 4.3 4TTL6048A 4.3 4TTL6060A 4.4 934 (36 3/4) 934 (36 3/4) 934 (36 3/4) 934 (36 3/4) 934 (36 3/4) 934 (36 3/4) 1086 (42 3/4) 1016 (40) 1016 (40) 1016 (40) 1194 (47) 1194 (47) 1194 (47) 1194 (47) 368 (14 1/2) 368 (14 1/2) 368 (14 1/2) 445 (17 1/2) 445 (17 1/2) 445 (17 1/2) 445 (17 1/2) 19 (3/4) 19 (3/4) 19 (3/4) 22 (7/8) 22 (7/8) 22 (7/8) 22 (7/8) 10 (3/8) 10 (3/8) 10 (3/8) 10 (3/8) 10 (3/8) 10 (3/8) 10 (3/8) 53 (2 1/16) 53 (2 1/16) 53 (2 1/16) 53 (2 1/16) 53 (2 1/16) 53 (2 1/16) 60 (2 3/8) 142 (5 19/32) 142 (5 19/32) 142 (5 19/32) 187 (7 11/32) 187 (7 11/32) 187 (7 11/32) 187 (7 11/32) 101 (3 31/32) 101 (3 31/32) 101 (3 31/32) 101 (3 31/32) 101 (3 31/32) 101 (3 31/32) 101 (3 31/32) 120 (4 23/32) 120 (4 23/32) 120 (4 23/32) 159 (6 1/4) 159 (6 1/4) 159 (6 1/4) 159 (6 1/4) 22-1931-1D-EN 3

Sound Power Level Table MODEL A-Weighted Sound Power Level [db(a)] Full Octave Sound Power(dB) 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TTL6018A1 70 55 77 71 66 67 61 53 43 4TTL6024A1 70 55 77 71 66 67 61 53 43 4TTL6030A1 71 55 77 72 66 67 62 54 45 4TTL6036A1 72 56 76 76 70 66 62 55 48 4TTL6042A1 73 56 77 76 71 67 62 56 48 4TTL6048A1 73 56 77 76 71 67 62 56 48 4TTL6060A1 73 59 78 77 69 67 62 57 52 Note: Rated in accordance with AHRI Standard 270 *For Reference Only MODEL Sound Pressure [db(a)] 3 ft 5 ft 10 ft 15 ft 4TTL6018A1 63 58 52 49 4TTL6024A1 63 58 52 49 4TTL6030A1 64 59 53 50 4TTL6036A1 65 60 54 51 4TTL6042A1 66 61 55 52 4TTL6048A1 66 61 55 52 4TTL6060A1 66 61 55 52 Note: Rated in accordance with AHRI Standard 275 4 22-1931-1D-EN

Product Specifications Model No. (a) 4TTL6018A1XXXA 4TTL6024A1XXXA 4TTL6030A1XXXA 4TTL6036A1XXXA HIGH SPEED COOLING CAPACITY@ 80/67-95 (Btuh) 18000 24000 28200 35000 POWER CONNS. V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 12 13 17 19 BR. CIR. PROT. RTG. MAX. (AMPS) 20 20 25 30 COMPRESSOR CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL AMPS LR AMPS 9 48 10.1 52 12.8 67.8 14.7 75 Outdoor Fan FL AMPS 0.54 0.54.64.67 Fan HP 1/12 1/12 1/8 1/8 Fan Dia (inches) 23.5 23.5 23.5 27.0 Coil PLATE FIN PLATE FIN PLATE FIN PLATE FIN Refrigerant R-410A 4 LBS., 10 OZ 4 LBS., 8 OZ 5 LBS., 9 OZ 6 LBS., 7 OZ LINE SIZE IN. O.D. GAS (c) 3/4 3/4 3/4 3/4 LINE SIZE IN. O.D. LIQ. 3/8 3/8 3/8 3/8 Charge Spec. Subcooling 10 F 10 F 10 F 10 F Dimensions H x W X D Crated (IN.) 40.75 x 47.5 x 20.0 40.75 x 47.5 x 20.0 40.75 x 47.5 x 20.0 40.88 x 54.5 x 23.0 Weight Shipping (lbs.) 165 165 180 242 Weight Net (lbs.) 145 145 160 215 Optional Accessories: Evaporator Defrost Control AY28X079 AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT302RES BAYCCHT302RES BAYCCHT302RES BAYCCHT302RES Snow Leg Kit 4 BAYLEGS004 BAYLEGS004 BAYLEGS004 BAYLEGS004 Snow Leg Kit 7 BAYLEGS007 BAYLEGS007 BAYLEGS007 BAYLEGS007 Scroll Compressor Enclosure BAYSDEN003 BAYSDEN003 BAYSDEN003 BAYSDEN003 Low Ambient Kit BAYLOAM107A BAYLOAM107A BAYLOAM107A BAYLOAM107A Wall Mount Kit BRK05033 (d) BRK05033 (d) BRK05033 (d) BRK05033 (d) Wind Baffle Kit BAYWIND100 BAYWIND100 BAYWIND100 BAYWIND101 Refrigerant Lineset (e) TAYREFLN7* TAYREFLN7* TAYREFLN7* TAYREFLN7* (a) (b) (c) (d) (e) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Standard line lengths 150, Standard lift 50 Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32 3312 0* (* denotes latest revision).. Available from Trane Parts * = 15, 20, 25, 30, 40 and 50 foot lineset available. 22-1931-1D-EN 5

Product Specifications Model No. (a) 4TTL6042A1XXXA 4TTL6048A1XXXA 4TTL6060A1XXXA HIGH SPEED COOLING CAPACITY@ 80/67-95 (Btuh) 41000 46500 56000 POWER CONNS. V/PH/HZ (b) 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 22 24 31 BR. CIR. PROT. RTG. MAX. (AMPS) 35 40 50 COMPRESSOR CLIMATUFF - SCROLL CLIMATUFF - SCROLL CLIMATUFF - SCROLL RL AMPS LR AMPS 16.7 109 18.5 124 23.7 152.5 Outdoor Fan FL AMPS 1.18 1.18 1.05 Fan HP 1/5 1/5 1/5 Fan Dia (inches) 27 27 27 Coil PLATE FIN PLATE FIN PLATE FIN Refrigerant R-410A 6 LBS., 14 OZ 6 LBS., 14 OZ 7 LBS., 4 OZ LINE SIZE IN. O.D. GAS (c) 7/8 7/8 1 1/8 LINE SIZE IN. O.D. LIQ. 3/8 3/8 3/8 Charge Spec. Subcooling 10 F 10 F 10 F Dimensions H x W X D Crated (IN.) 40.88 x 54.5 x 23.0 40.88 x 54.5 x 23.0 46.88 x 54.5 x 23.0 Weight Shipping (lbs.) 243 243 263 Weight Net (lbs.) 216 216 236 Optional Accessories: Evaporator Defrost Control AY28X079 AY28X079 AY28X079 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 Crankcase Heater Kit BAYCCHT301RES BAYCCHT301RES BAYCCHT301RES Snow Leg Kit 4 BAYLEGS004 BAYLEGS004 BAYLEGS004 Snow Leg Kit 7 BAYLEGS007A BAYLEGS007A BAYLEGS007A Scroll Compressor Enclosure BAYSDEN004 BAYSDEN004 BAYSDEN004 Low Ambient Kit BAYLOAM107A BAYLOAM107A BAYLOAM107A Wall Mount Kit BRK05033 (d) BRK05033 (d) BRK05033 (d) Wind Baffle Kit BAYWIND101 BAYWIND101 BAYWIND101 Refrigerant Lineset (e) TAYREFLN7* TAYREFLN7* TAYREFLN7* (a) (b) (c) (d) (e) Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240. Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. Standard line lengths 150, Standard lift 50 Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32 3312 0* (* denotes latest revision).. Available from Trane Parts * = 15, 20, 25, 30, 40 and 50 foot lineset available. 6 22-1931-1D-EN

Accessory Description and Usage Evaporation Defrost Control SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30 F with TXV. Rubber Isolators Six (6) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start Kit Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Model Nomenclature AHRIStandard Capacity Rating Conditions AHRI Standard 210/240 Rating Conditions 1. Cooling80 F DB,67 FWB air enteringindoor coil,95 FDB airentering outdoor coil. AHRI Standard 270 Rating Conditions (Noise rating numbers are determined with the unit in cooling operations.) Standard Noise Rating number is at 95 F outdoor air. Outdoor Units 4 T W V 0 0 3 6 A 1 0 0 0 A A Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family V = Variable Speed Z = Leadership Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial L = Side Discharge Family SEER 3 = 13 6 = 16 0 = 20 4 = 14 8 = 18 5 = 15 9 = 19 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier 22-1931-1D-EN 7

Wiring Schematic: 1.5 4 Ton Models NOTES: 1. IF ODT-B IS NOT USED, ADD JUMPER BETWEEN W2 & W3 AT AIR HANDLER. IF USED, ODT-B MUST BE MOUNTED REMOTE OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. 2. IF ODT-A IS NOT USED, ADD JUMPER BETWEEN W1& W2 AT AIR HANDLER. 3. LOW VOLTAGE (24V) FIELD SIRING MUST BE 18 AWG MIN. 4. USE COPPER CONDUCTORS ONLY! Dwg. D159847P01 8 22-1931-1D-EN

Wiring Wiring:1.5 4Ton Models 22-1931-1D-EN 9

Wiring Schematic: 5 Ton Models NOTES: 1. IF ODT-B IS NOT USED, ADD JUMPER BETWEEN W2 & W3 AT AIR HANDLER. IF USED, ODT-B MUST BE MOUNTED REMOTE OF CONTROL BOX IN AN APPROVED WEATHER PROOF ENCLOSURE. 2. IF ODT-A IS NOT USED, ADD JUMPER BETWEEN W1& W2 AT AIR HANDLER. 3. LOW VOLTAGE (24V) FIELD SIRING MUST BE 18 AWG MIN. 4. USE COPPER CONDUCTORS ONLY! 10 22-1931-1D-EN

Wiring Wiring: 5 Ton Models 22-1931-1D-EN 11

Mechanical Specification Options General The OutdoorUnits are fully chargedfrom the factory forup to 15feet of piping. This unitis designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities are matched withawideselection of air handlers andfurnace coils thatare AHRIcertified. The unitis certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish. The corner panels are prepainted. All panels are subjected to our 1,000 hour saltspray test. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and low and high pressure switches. A factory supplied, field installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection. Other features include: Centrifugal oil pump and low vibration and noise. Condenser Coil The aluminum plate fin, copper tube outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected with a corrosion resistant mesh coil guard. Low Ambient Cooling As manufactured, this system has a cooling capacity to 55 F. The addition of an evaporator defrost control permits operation to 40 F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30 F. The addition of the BAYLOAM107A low ambient kit permits ambient cooling to 20 F. Thermostats Cooling only and heat/cooling(manual and automatic change over). Sub-base to match thermostat and locking thermostat cover. 12 22-1931-1D-EN

Notes 22-1931-1D-EN 13

Notes 14 22-1931-1D-EN

Notes 22-1931-1D-EN 15

Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands including Club Car, Ingersoll Rand, Thermo King and Trane work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. ingersollrand.com The AHRI Certified mark indicates Ingersoll Rand participation in the AHRI Certification program. For verification of individual certified products, go to www.ahridirectory.org. Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 22-1931-1D-EN 05 Jan 2018 Supersedes 22-1931-1C-EN (December 2017) 2017 Ingersoll Rand