DC inverter all in one Model KP 5A KP 7A KP 9A KP 12A KP 15A KP 21A Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw 4.5 6.5 8.5 11 13.5 19 COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 Temperature range heating ºC 2 55 2 55 2 55 2 55 2 55 2 55 Temperature range cooling ºC 7 2 7 2 7 2 7 2 7 2 7 2 outdoor unit compressor quantity 1 1 1 1 1 1 compressor type twin rotary twin rotary twin rotary twin rotary scroll scroll Dimensions (W x H x D) mm 84x59x29 84x7x315 88x78x36 83x123x31 93x127x39 93x127x39 1. test condition: heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 3ºC / 35ºC cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC 2. function: house heating. Optional function: house cooling electrical heater backup: add USD45 3 way water valve for sanitary hot water: add USD55 3. all in one design outdoor unit: DC inverter compressor, 3 heater for defrosting, circulation pump, water flow switch optional compoments: electrical heater backup, 3 way water valve the connection between outdoor unit and indoor applications are anti freeze no water freeze on outdoor unit. 4. Fuzzy defrosting
DC inverter compressor DC inverter all in one installation
DC inverter split Model KP 5D KP 7D KP 9D KP 12D KP 15D KP 21D Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw 4.5 6.5 8.5 11 13.5 19 COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 Temperature range heating ºC 2 55 2 55 2 55 2 55 2 55 2 55 Temperature range cooling ºC 7 2 7 2 7 2 7 2 7 2 7 2 Indoor unit Electrical heater backup kw 2 3 3 3 2+2+2 3+3+3 Dimensions (W x H x D) mm 45x55x255 45x55x255 45x55x255 45x55x255 45x55x255 45x55x255 outdoor unit compressor quantity 1 1 1 1 1 1 compressor type twin rotary twin rotary twin rotary twin rotary scroll scroll Dimensions (W x H x D) mm 84x59x29 84x7x315 88x78x36 83x123x31 93x127x39 93x127x39 1. test condition: heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 3ºC / 35ºC cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC 2. function: house heating. Optional function: house cooling electrical heater backup: add USD45 3 way water valve for sanitary hot water: add USD55 3. split design outdoor unit: DC inverter compressor, 3 heater for defrosting indoor square tank: circulation pump, water flow switch, electrical heater backup the connection between outdoor unit and indoor square tank is refrigerant R41a, copper connective piping. no water freeze on outdoor unit. 4. Fuzzy defrosting
DC inverter compressor DC inverter split installation 1
DC inverter split installation 1
DC inverter split installation 2
DC inverter split combo Model KP 5 KP 7 KP 9 KP 12 KP 15 KP 21 Power supply V/Hz/Ph 23/5/1 23/5/1 23/5/1 23/5/1 38/5/3 38/5/3 Nominal heating capacity kw 5 7 9 12 15 21 Nominal cooling capacity kw 4.5 6.5 8.5 11 13.5 19 COP 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 3.9~4.2 EER 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 2.1~2.8 Temperature range heating ºC 2 55 2 55 2 55 2 55 2 55 2 55 Temperature range cooling ºC 7 2 7 2 7 2 7 2 7 2 7 2 Indoor unit buffer tank built in liter 18 18 18 18 18 18 Electrical heater backup kw 2 3 3 3 2+2+2 3+3+3 Dimensions (W x H x D) mm 6x18x64 6x18x64 6x18x64 6x18x64 6x18x64 6x18x64 outdoor unit compressor quantity 1 1 1 1 1 1 compressor type twin rotary twin rotary twin rotary twin rotary scroll scroll Dimensions (W x H x D) mm 84x59x29 84x7x315 88x78x36 83x123x31 93x127x39 93x127x39 1. test condition: heating: ambient temperature ( DB/WB ): 7ºC / 6ºC, water temperature ( in/out ): 3ºC / 35ºC cooling: ambient temperature ( DB/WB ): 35ºC / 24ºC, water temperature (in/out): 12ºC / 7ºC 2. function: sanitary hot water, house heating. Optional function: house cooling, solar panel 3. split design outdoor unit: evaporator, fan, 3 heater for defrosting indoor square tank: compressor, circulation pump, heat exchanger, 18 liter tank, electrical heater backup the connection between outdoor unit and indoor square tank is refrigerant R41a, copper connective piping. no water freeze on outdoor unit. No heat loss on outdoor unit 4. Fuzzy defrosting DC inverter split combo Installation Plan
DC inverter split with tank Application
DC inverter split combo with 18L tank inside refrigerant part install a module. This module can remove or install quickly. It is good for after service and maintaince.