Agam Greenhouse Energy Systems Ltd.

Similar documents
ARAVA RESEARCH AND DEVELOPMENT

27/11/2015. How does a greenhouse work: humidity. Energiezuinig ontvochtigen. Climate control, humidity

Energy Saving of Inverter Air Conditioner and R32 Refrigerant DAIKIN VIETNAM. 13 th May 2017

- Murdoch University, Western Australia.

Active Chitosan. 100 Natural. Biostimulant. With. For use in all type of crops. Developed at The University of Cambridge

Technology Transfer of Greenhouse Aeroponic Lettuce Production Information to Alberta Growers,

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

4. Use the Plant Cultivation Chart to look up whether or not the plant variety needs a heating mat to start the seeds, and type of plant hardiness.

Daikin Altherma Selection Report

2017 Sweet Potato Slip Production Research Update

Thermal Environment in a Space with Capillary Mats Large-Area Cooling and Heating

Maximizing Vine Crop production with Proper Environmental Control

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

Growmaster Procom Precision Control, Multiple Zone Capability, Easy Operation

Heat Pumps and Public Swimming Pools, a Perfect Match

ACTIVITY 1 IT ALL ADDS UP Part A. Discuss the sections on the sample electric bill and provide time for students to graph the

High Tunnel Temperature Observations 2000

Ann Hazelrigg NE Vegetable and Fruit Conference December 17, MOLD- Managing. Tomato Diseases in Tunnels

Fruit Size Management Guide Part 2

MICRO GROW GREENHOUSE SYSTEMS, INC ZEVO DR., SUITE B-1, TEMECULA, CA PHONE (951) FAX (951) Growmate Growmate Plus

AERECO DEMAND CONTROLLED VENTILATION COMBINING INDOOR AIR QUALITY AND ENERGY SAVINGS

Organic Vegetable Gardening Transplants

Use words from the list to complete the following sentences. Words may be used once, more than once, or not at all.

Use of Adapted Energy Screens in Tomato Production with Higher Water Vapour Transmission

Protecting Your Investment Has Never Been So Simple.

A Practical Guide for Natural Aeration Grain Drying

So far, we have covered the basic concepts of heat transfer and properties.

Open Cooling Tower. Equipment Layout Guide

2 Safety valve. 3 Pressure gauge. 4 Thermometer. 8 Ball valves

The Sunergy Greenhouse - One Year of Measurements in a Next Generation Greenhouse

Master Gardener Vegetable Specialist Training. Prepared by: Thomas LeRoy

Understanding Water Use by Plants in a Cloche System - Gardening

MIXING RATIO AND ABSOLUTE HUMIDITY

Vegetarian Newsletter

Performance Analysis of a Thin Tube Water Heater for Egerton University Using Comsol

Experimental Research on Monomial Cooling Measure of Greenhouse in Summer

(a) (i) Through which part of the house is most heat lost? How can the heat loss through the windows be reduced? ...

Instructor: Stephen L. Love Aberdeen R & E Center 1693 S 2700 W Aberdeen, ID Phone: Fax:

This supplemental label expires December 31, 2017 and must not be used or distributed after this date.

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Greenhouses. 4/25/2018 DUBI SEGAL

Cost of a Thanksgiving Meal

Performance Analysis of Solar Air Heater Using Three Wire Mesh

A/C Cooling Load calculation and measurement

GRAIN STORAGE AERATION PRESENTED BY: BRENT BLOEMENDAAL AERATION EXPERT

Dynamic performance of a novel dew point air conditioning for the UK buildings

BEDDING PLANTS are immensely popular and

Rust Update San Angelo April 2, Dr. David Drake, Texas A&M AgriLife Extension San Angelo

POINSETTLA PROPAGATION-CUTT 1KG.SIZEl

Household Carbon Footprint Calculator

Integrated Pest Management #4

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

Heat Pump Water Heaters: Laboratory and Field Evaluation of New Residential Products

CALU Nursery Stock Workshop Talgoed Nurseries, Conwy Valley 6 th February 2008

Lesson Plan Contest 2018 Growing Food for Our Classroom Animals: Exploring Hydroponics Grades PR-K 2 nd

MICRO GROW. GREENHOUSE SYSTEMS, INC ZEVO DR., UNIT B-1, TEMECULA, CA PHONE (951) FAX (951)

Growing in Movable High Tunnels Reviewing five years of experience at Massaro Community Farm, Woodbridge, CT

High frequency irrigations as means for reduction of pollution hazards to soil and water resources and enhancement of nutrients uptake by plants

Ventilation and Cooling of Greenhouses NATURAL VENTILATION

RenewableEnergy. A Guide to Prepare for a Grain Dryer Energy Audit. Introduction. Fueling and Feeding America Through Renewable Resources

DRYING YELLOW-POPLAR IN A SOLAR-DEHUMIDIFIER KILN WITH HEAT STORAGE AND HEAT RECOVERY SYSTEMS

Storing excess daytime solar energy to heat greenhouse at night!

Hoop Houses. Beth LaShell Fort Lewis College February 2, 2012

Gardening Beyond the Frost

Thermal Performance Of Low Cost Solar Bamboo Dryer

Energy management in protected cropping: Humidity control

Energy Saving Fact Sheet Agriculture & Horticulture

Electric radiator tests

Environmental Control System

Cost of a Thanksgiving Meal

An Introduction of Below-Freezing and Humidity Environment Controlling Technology Equipped on Brake Test Equipment

Q1. The diagram shows an experiment to find out what happens to infrared waves when they strike different surfaces.

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

MORE POINSETTIAS are grown than any

MSP WRAP-AROUND MULTIPLE SMALL PLATE DEHUMIDIFICATION TECHNOLOGY VS. CONVENTIONAL DEHUMIDIFICATION IN DEDICATED OUTDOOR AIR SYSTEMS (DOAS)

Introduction. Institute of Food and Agricultural Sciences North Florida Research and Education Center Suwannee Valley

Like Us. Made in England. Assembly and Maintenance Instructions. Call:

Grafting Technologies and Their Trends

Greenhouse Temperature Management

Thermodynamics II Chapter 6 Mixtures & Psychrometry

STATION RISK PROFILE 2018 EWYAS HAROLD

Using super oxygenated water in high tunnel tomato and strawberry production

Space Conditioning Interactions with Heat Pump Water Heaters: A Test in the PNNL Side-by-Side Lab Homes

Procom Greenhouse Control System

Desiccant Cooling with Solar Energy

Reducing Energy Use in Grain Dryers

Heat Pump Water Heater Commercial Leaflet 2012

IN CASE OF EMERGENCY DUE TO A MAJOR SPILL, FIRE OR POISONING INVOLVING THIS PRODUCT CALL DAY OR NIGHT,

Crops: Selection & Cultivation

Growing Conditions and Crop Performance in High Tunnels

MOVEMENT OF WATER THROUGH PLANTS

Thick-Film Heater achieves Superior Performance in Thermal Response, Uniformity and Efficiency.

Cycling Refrigerated Air Dryers

Microirrigation of Young Blueberries in Florida 1

subwoofer instructions

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

Different energy sources can be used to generate electricity.

Optimizing Cherry Production: Physiology-Based Management. Gregory Lang Michigan State University

Evaluating Suitable Tomato Cultivars for Early Season High Tunnel Production in the Central Great Plains

MECHANICAL SCIENCE Module 2 Heat Exchangers

Transcription:

~1~ Test of Agam's VLHC (Ventilated Latent Heat Converter) machine in Arava R&D center Nov. 2008 Feb. 2009 16 Arlozorov St. Hod Hasharon 45203, Israel

Background ~2~ Arava valley is the largest export oriented center for winter growing crops with 1400 Hectare of pepper greenhouses and 600 Hectare of tomatoes and other vegetable. Agam VLHC dehumidifier was introduced to a 1000 square meter Pepper greenhouse No. 3 (GH3) at the R&D Arava tests center (see Picture in page 1) Water heater provided the heat to Agam unit. Identical 1000 square meter of pepper greenhouse No 9 (GH9) (orange in the graph) used as a reference to Agam's. The reference GH was heated by hot water pipes with separate hot water heater. The tests run from Nov. 2008. In Feb. 14 2009 two calorimeter introduced into the two GH where hot water temperature and flow rate recorded in a 10 minutes intervals (see Excel table Heating profile.) Temperature and humidity probes were located at the center of each GH at a 2m height. The climate conditions recorded at 20 minutes intervals (see Excel table below). Ambient temperature and humidity conditions were measured in a meteorological station near the tested greenhouses. Additional greenhouse (GH 5) kept without heating and without screen (colored yellow In the graphs) The walls in greenhouses 3, 9, and 5 were ventilated due to gaps left between the moving curtains and the stationary walls. Tests procedure At mid Feb., two calorimeters recorded the heat introduces into GH 3 and GH 9 in 10 minutes intervals. In the table bellow, we compared 5 nights where the thermal screens and wall curtains (see picture above) where closed in the two greenhouses from 17:00 in the evening to 07:00 in the next mornings. Temperature and humidity recorded in 20 min. intervals at GH 3 (Agam), GH 9 (Hot water pipes) and ambient meteorological units. 16 Arlozorov St. Hod Hasharon 45203, Israel

%RH Humidity ~3~ The average and maximum humidity are given in the two charts + tables bellow. In greenhouse 3- average humidity in the 5 nights was 78% and maximum humidity was 82%. In greenhouse 9- average humidity was 83.2% and maximum humidity 88%. In GH 5 yellow charts (no heating) humidity follow the outside humidity, which farther indicate the roll of ventilation in reducing humidity. Agam units keep the humidity level 5% bellow greenhouse 9 with hot water heating. The maximum humidity in greenhouse 9 is close to the limit above which humidity prompted condensation and plant disease. Therefore the ventilation in greenhouse 9 is important to keep humidity at the design value. The basic data collection of humidity is given in the attached excel table Humidity profiles. The night's averages and maximum humidity are given in the tables bellow. Average %RH in Greenhouses 100 90 80 70 60 50 16.2.09 20.2.09 23.2.09 24.2.09 27.2.09 G3-Agam 77 79.7 78.3 77.9 77.1 G9 H-W 80.8 84.1 84.2 83.3 83.2 G5A- No Screen 77.8 71 74.1 74.6 73.7 Outside 59 48.9 46.7 50.2 53.7 Dates 40 16 Arlozorov St. Hod Hasharon 45203, Israel

%RH ~4~ Max %RH Iin Greenhouse 100 95 90 85 80 75 Energy used The inside air temperature tables are given in the attached excel table "Temperature profiles" in greenhouses 3 (Agam), 9 (Hot water) and 16.2.09 20.2.09 23.2.09 G3- Agam 80.1 85.1 83 82.1 80.8 G9- H-W 85 88.6 88.8 88.2 89 G5A- No Screen 92.5 75.3 86.7 90.2 92.2 Outside 64.5 59 59.7 64.5 87.2 Date 24.2.09 27.2.09 70 65 60 55 50 16 Arlozorov St. Hod Hasharon 45203, Israel

Energy used ~5~ The inside air temperature tables are given in the attached excel table "Temperature profiles" in greenhouses 3 (Agam), 9 (Hot water) and ambient. The calorimeter data is given in Excel table "Heating profiles". Applying the calorimeters recorded data for the 2 greenhouses we obtain heating energy in kwh. Thermal gradient (Degree-Hours) was calculated for each greenhouse and each night. The energy dissipation was calculated by divided the heating energy by the greenhouse area (1000 square meter) and by degree-hours to yield the heat conductivity (W/m 2 * 0 C). The results are given bellow: 16 Arlozorov St. Hod Hasharon 45203, Israel

~6~ The energy saving of Agam systems is given bellow: Summary Agam unit kept the average greenhouse humidity at 78% compared with 82% in the greenhouse heated by hot water pipes. The maximum humidity was 83% in Agam's green house as compared with 88% at the hot water heating greenhouse. The average energy saving in Agam's greenhouse was 60%. Thus Agam's unit keeps plant diseases induces by humidity away, and reduces fuel consumption to 40% of its present use. 16 Arlozorov St. Hod Hasharon 45203, Israel