KVF - Capture Jet canopy with Supply Air and Side-Jet Technology KVF. Capture Jet Canopy with Supply Air and Side-Jet Technology

Similar documents
UVF - Capture Jet canopy combined with Capture Ray TM technology and low velocity supply air UVF

KCJ - Closed kitchen ceiling with Capture Jet system KCJ. Closed kitchen ceiling with Capture Jet system

KSR - Backshelf Capture Jet TM hood with or without Side Jets KSR. Backshelf Capture Jet TM hood with or without Side Jets

KWF - Capture Jet TM hood combined with Water Wash technology and Supply Air KWF

Halton. Capture Jet technology and service systems. Enabling Wellbeing

JSI-UV canopy - Ultraviolet and cyclonic filters, and supply air JSI-UV hoods Product Description Lights and filters

TURBO HOODS. Product Brochure

UV-TURBO HOODS. Product Brochure

M.A.R.V.E.L. Intelligent Demand Controlled Ventilation System for Professional Galleys. Enabling Wellbeing

NORDcanopy Kitchen ventilation

MEGA YACHTS CRUISE SHIPS CARGO FERRIES OIL RIGS

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

VENTILATED CEILINGS PLENUM SPANTILE COMBINED ADVANTAGES

Halton - Meeting the Kitchen Ventilation challenges of multiple venues in Hotels, Casinos and Resorts

Halton MobiChef Unleashed Business Opportunities! INNOVATION 2014 Patent Pending

for commercial kitchen ventilation

The swirl comfort unit is a compact air-conditioning unit providing swirl jet air supply.

Capture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING

Units for suspended ceilings

LABGARD NU-602 CLASS II TYPE A2 ANIMAL HANDLING BIOLOGICAL SAFETY CABINET

Electrostatic Precipitator

REQUIREMENTS FOR HOOD PLANS

JSKI Installation-, adjustment and user guide

Units for suspended cei lings

Air Handling Units. T F E.

Equipment guide for local exhaust ventilation (LEV)

Excellent Ventilation for Professional Kitchens

KCW - CLEAN closed ventilated ceiling with water wash and Capture Jet technologies KCW

Clean Air Laminar Flow Ceiling CG 3 A CLEAN AIR WORLD. Draft-free, comfortable room climate. Minimal, undisruptive noise level

Type VDW WITH LOW SOUND POWER LEVEL FOR COMFORT ZONES, WITH INDIVIDUALLY MANUALLY ADJUSTABLE AIR CONTROL BLADES

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

SKV, TPV Ventilation and extraction ceilings for industrial kitchens

Are Your Kitchen Hood Filters Compliant?

KITCHEN EXTRACTORS K Series

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

GOLDEN TEMPLE AMRITSAR SPECIFICATIONS FOR KITCHEN EQUIPMENT

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Design ceiling swirl diffusers > Type ADD. Type ADD

DOWNDRAFT BENCH SERIES

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

CBC - Active Chilled Beam. Halton CBC. Active Chilled Beam

Introduction to the Exhaust Fan Interceptor Commercial Exhaust Fans from a Service Perspective

PRESENTATION SUMMARY

(INDUSTRIAL) KITCHEN VENTILATION MODERN (INDUSTRIAL) KITCHEN VENTILATION SYSTEMS REFERENCES

MSYS 4490 AC Systems

Laboratory Fume Cupboards

Secomak. Air at Work. Air Knife Solutions for Every Industry

Ceiling swirl diffusers

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

Swegon PACIFIC. Integrated chilled beam PACIFIC CHILLED BEAM KEY FIGURES

KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

SECTION KITCHEN HOOD AND DUCT FIRE SUPPRESSION SYSTEM

Halton Rex 600 Basic R6B - Active chilled beam

AN ANALYSIS OF THE ACTUAL THERMAL PLUMES OF KITCHEN APPLIANCES DURING COOKING MODE

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

FT900SDBD DUAL RINSE FLIGHT-TYPE DISHWASHER

Halton Rex for Vario R6O - Variable air volume chilled beam

The Enviro-Clean Air Scrubber keeps the Atmosphere Clear and Creates Clean Air

Operating Room Diffuser System with Integrated LED Lighting

A new range of professional combi and convection ovens.

Compact. Efficient. TROX.

Supply air hood JSI-UV Installation-, adjustment and user guide

It is critical to maintain the Beech Oven and associated equipment on a regular basis, to avoid the possibility of a serious fire or malfunction.

Glossary of Terms Laboratory & Fume Exhaust Fans

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Research Document Type: PROCEDURE. Effective Date: January 01,2015 Author Steven Hayes

FT900BD FLIGHT-TYPE DISHWASHER

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

Drying. and cleaning. systems. Secomak... the cutting edge

AIR HANDLING UNITS MANDÍK

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

EvaPack SERIES EVAPORATIVE PAD ADIABATIC HUMIDIFIERS

GreenJet Transfer Fans

Systemair product news - Fans NEWS

Ceiling swirl diffusers

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Compact Filter Unit Type CFU

ATC Heating Devices. P. 1 ATC Heating Devices

MECHANICAL VENTILATION

CONDOR. Supply air ceiling QUICK FACTS

FOUNDATIONS OF MODERN KITCHEN VENTILATION (CKV) DESIGN HANDBOOK

All the products you need for. Engineered Kitchen Ventilation Systems.

Use of energy recovery systems in air conditioning, ventilation or screening

User s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel.

gaps between walls or ceilings and cornices fixed air conditioners and heaters construction joints between wall materials

Smart air handling unit for swimming pools IN CONFORMITY WITH THE REQUIREMENTS OF

Displacement Ventilation

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Ceiling diffusers. Type DLQL

FT900 FLIGHT-TYPE DISHWASHER

CBH - Active Chilled Beam. Halton CBH. Active Chilled Beam

our technology Electrostatic Precipitators esp plus maintenance features Electrostatic Precipitators

InspirAIR Compact Heat and Energy Recovery. Multi-Family HRV/ERV

Additional operating instructions according to ATEX 2014/34/EU Ceiling Impulse Diffuser Model PIL

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Electrostatic Air Cleaners for Commercial and Industrial Applications

Transcription:

KVF Capture Jet Canopy with Supply Air and Side-Jet Technology ALLIED EBER R LISTED HACCP* certified (PE-567-H01I). 30 to 40% reduction in exhaust airflow rates thanks to the Capture Jet technology. High-efficiency KSA multi-cyclone filters (UL, SF and LPS 1263 classified). Prevention of the build-up of grease deposits, which pose a serious hygiene and fire hazard. Draught-free integrated supply air system for enhanced smoke capture and comfort. Performance tested independently in accordance with the AST 1704 standard. Exhaust airflow rates based on AST performance and a calculation method of the real heat loads. Equipped with Accuflow monitoring device, ensuring the canopies are running at designed airflows. Accurate and effective commissioning due to ready to install standard delivery packages. Stainless steel construction with seamless design for improved hygiene and fire safety. The KVF canopy with the new generation of peripheral, vertical and horizontal Capture Jet technology is a highly efficient kitchen ventilation canopy that removes contaminated air and excess heat emitted by cooking equipment, while delivering compensation air to the kitchen at low velocity. Overall, the system requires 30% to 40% less exhaust air volume than traditional canopies do to remove an equal heat load. KVF canopies are equipped of displacement units integrated on their front face. Compensation air is delivered at a low velocity thus further improving canopy efficiency and providing a comfortable and clean environment for the chef. The filtration is ensured by high-efficiency KSA multicyclone filters, UL and SF classified. KSA filters remove up to 95% of particles with a size of 10 microns or above thus reducing grease deposits and cleaning costs while improving hygiene and safety. Capture Jet canopies are delivered ready to install allowing accurate and effective installation and commissioning. Standard delivery includes lighting, integrated Capture Jet fan, Testing and Balancing taps and balancing dampers. * Hazard Analysis Critical Control Point 1

4 4 3 3 2 2 1 1 Operation and Description Cooking equipment generates large plumes of hot air, loaded with grease particles, grease vapours, water, and odours. These plumes or convective flows (1) naturally rise toward the kitchen ceiling. The combination of the peripheral, horizontal and vertical Capture Jets (2) with the low velocity air supply (3) allows convective flows to rise freely and be removed by the extraction plenum (4) as quickly as possible. The profile of the inside of the canopy in association with the action of the Capture Jets allows effective containment of both regular and sudden outputs of smoke or steam. The Capture Jet technology, the low velocity supply and the internal shape of the canopy ensure the best capture and containment capacity thus reducing the exhaust airflows by 30% to 40%. The KVF kitchen canopy comprises a supply fascia unit (3) with control damper type S, a Capture Jet unit with front and side jets, a Capture Jet centrifugal fan, an IP65 light fitting, adjustable exhaust dampers, airflow measurement taps and KSA grease filters. All visible parts of the canopy are manufactured from polished stainless steel AISI 304. Joints on the lower edge are fully welded. Testing And Balancing (T.A.B. T ) taps for flow measurement are fitted to the exhaust, supply and Capture Jet supply air plenums. 2

Double and Peripheral Capture Jet Technology Reduces exhaust airflows and energy consumption by 30% to 40% due to higher capture and containment efficiency. Better indoor air quality and comfort. The Capture Jet technology consists of two sets of nozzles, one vertical and one horizontal. - The horizontal nozzles push vapours back towards the filters. - The vertical nozzles increase the containment volume and prevents vapours escaping from cooking areas. The bottom edge of the exhaust plenum is aerodynamically designed not to disturb the rising up of the thermal plumes, thus further improving the Capture Jets action. KSA Cyclonic Filters inimisation of grease deposits in the ducts Enhanced hygiene and safety The KSA cyclonic filters are composed of honeycomb profiles, which forces the air to swirl inside the profiles. The centrifugal effect is significant and, above all, continuous especially in comparison to the action of traditional filters. Particles are thus pushed against the profiles. The collected condensation flows naturally towards the extraction plenum drains. The KSA filters are 95% efficient in removal of 10 µm particles. They are UL-accredited as flame-resistant and have SF hygiene and safety approval. Constructed from AISI 304 (1.4301) polished stainless steel. 100 Efficinecy @ 120 Pa [%] 80 60 40 20 0 1 2 3 4 5 6 7 8 9 10 Particle size [μm] WITHOUT Capture Jets Heat spilling WITH Capture Jets Capture & containment Efficiency curve of the KSA cyclonic filters based on the VDI 2052 method (part 1) «Ventilation Equipment for kitchens. Determination of Capture Efficiency of Aerosol Separators in Kitchen Exhaust» 3

C Front Face Low Velocity Air Compensation Draught-free compensation control High comfort levels for users The KVF front faces are designed to spread fresh air through the kitchen with the displacement principle, at a very low velocity. The absence of draughts not only helps to avoid dispersing convective flows from the cooking equipment but also guarantees comfort to the chef. The capture air plenum is thermally insulated using non-fibre-releasing material to prevent vapours from condensing on the inner face of the canopy above the cooking equipment. Individual supply nozzles are adjustable to produce punctual small fresh air curtains near the cooking equipment, which helps to reduce the effect of the radiant heat given off by the cooking equipment. Comfort Limit Height Total control of air quality in the work area Wellbeing and productivity The front face low velocity supply allows the kitchen air to be renewed on the principle of air displacement. Fresh air naturally falls to the ground and fills the working area from that level. The absence of flow disturbances prevents this fresh air from spreading the convective flows generated by the cooking equipment. A comfort limit naturally appears in the kitchen s air levels through stratification. Below the limit height, air quality is optimal. 4

AccuFlow monitoring device Prevents the canopies to operate under abnormal conditions without the staff noticing it Simple and cost effective system against degradation of the energy consumprion, air quality, safety and hygiene in commercial kitchen. Warn the users when the exhaust airflow rate of each Capture Jet T canopy section is higher or lower than the designed one Pre-installed and programmed from factory in all Capture-Jet T canopies. Halton s AccuFlow console monitors exhaust airflow rates and informs operators of high or low air values ensuring the canopies are running at designed air flows. It prevents therefore the Capture Jet T canopies to operate under abnormal conditions without the staff noticing it. aintenance operations or corrective actions can be carried out without any delay.the energy savings achieved with the Capture Jet T technology as well as the air quality, safety and hygiene levels are then maintained almost permanently. Commissioning, Safety and aintenance Components are easy to access and clean aximum hygiene and maintenance The Capture Jet canopies are designed to reduce the number of external stainless steel components thus reducing the number of joints to be cleaned for maximum hygiene. The joints of the lower edge are fully welded to be liquid-tight, avoiding harmful dripping of condensation. The bottom edge of the exhaust plenum is aerodynamically designed to limit the condensation risk and also improve the canopy efficiency. The hinged light lens allows for access above the canopy. Halton' Accuflow is a simple and cost effective prevention tool ensuring a good operation of the canopies through the whole life cycle of the kitchen. 5

KVF DESCRIPTIO 2 4 3 10 9 11 1 8 7 6 5 CODE DESCRIPTIO 1 Outer casing visible parts in stainless steel AISI 304 2 Exhaust air connection and adjustment damper 3 Supply air connection and adjustment damper (type S) 4 Light fixture with electrical junction box 5 Capture Jet nozzles 6 KSA grease filter CODE DESCRIPTIO 7 Grease collection tray or drain tap 8 Personal supply air nozzles 9 Capture Jet fan 10 Capture Jet fan air inlet plenum 11 Perforated front face QUICK SELECTIO DATA L1 (active length) L (section Recommended Exhaust air volume* Recommended make up air volume Capture Jet air volume (with width = 1300) length) l/s m 3 /h H = H = l/s m 3 /h 1500 1600 420 654 1515 2358 200 l/s or 720 m 3 /h 157 l/s or 565 m 3 /h 27 97 2000 2100 560 872 2020... 3144 per linear meter per linear meter 31 112 2500 2600 700 1090 2525 3930 of section of section 35 127 5000 5100 1 2180 5050 7860 S 100% open S 100% open 56 202 7500 7600 2100 3270 7575 11790 Pst = 48 to 52 Pa Pst = 45 to 70 Pa 77 277 10000 10100 2800 4360 10100 15720 98 352 * inimum at a T.A.B. T reading of 50 Pa (505 m 3 /h or 140 l/s per filter)... maximum at a T.A.B. T reading of 120 Pa (786 m 3 /h or 218 l/s per filter) ASSEBLY OF ODULAR SECTIOS KVF One open end KVF One open end KVF Two open ends 6

DIESIOS KVF (2 closed ends) 205 250 170 250 I 315 L = 1100..3100 L1 = 1000..3000 25 ote: The dimensions above are for modular sections only; larger canopies are assembled using a combination of separate modules, which makes transportation and site handling easier. 1200..1900 LOCATIO OF COECTIOS (mm) For typical sizes Exhaust Supply Capture Jet Light 1 Ø315 2 Ø315 2Ø250 Ø160 L I* 1600 L/2 375 375 L/2 720 2100 L/2 500 500 L/2 1320 2600 L/2 500 500 L/2 1320 3100 L/2 500 500 L/2 1320 * 720 (L1<=1500, 2x18W), 1320 ( L1>1500, 2x36W) WEIGHT (h= mm, kg) L/B 1100 1300 1500 1700 1900 1100 86 91 97 107 113 50 1600 114 119 125 136 141 2100 141 147 152 164 170 2600 169 174 180 193 199 3100 196 202 207 222 228 450 175 50 7

DIESIOS KVF (1 closed end) 25 ote: The dimensions above are for modular sections only; larger canopies are assembled using a combination of separate modules, which makes transportation and site handling easier. 1200..1900 LOCATIO OF COECTIOS (mm) For typical sizes Exhaust Supply Capture Jet Light 1 Ø315 2 Ø315 2 Ø250 Ø160 L2 1 1 1 I* 1550 L2/2+25 L2/2-25 375 325 375 325 L2/2+25 720 2050 L2/2+25 L2/2-25 500 450 500 450 L2/2+25 1320 2550 L2/2+25 L2/2-25 500 450 500 450 L2/2+25 1320 3050 L2/2+25 L2/2-25 500 450 500 450 L2/2+25 1320 * 720 (L1<=1500, 2x18W), 1320 ( L1>1500, 2x36W) 205 250 170 250 315 1 1 1 1 I L2 = 1050..3050 L1 = 1000..3000 WEIGHT (h= mm, kg) L/B 1100 1300 1500 1700 1900 1100 86 91 97 107 113 50 1600 114 119 125 136 141 2100 141 147 152 164 170 2600 169 174 180 193 199 3100 196 202 207 222 228 450 175 8

DIESIOS KVF (2 opened ends) 25 ote: The dimensions above are for modular sections only; larger canopies are assembled using a combination of separate modules, which makes transportation and site handling easier. 1200..1900 205 250 1 170 250 1 1 I 1 315 1 1 1 1 LOCATIO OF COECTIOS (mm) For typical sizes Exhaust Supply Capture Jet Light 1 Ø315 2 Ø315 2Ø250 Ø160 L1 1 1 1 1 I* 1500 L1/2 325 325 L1/2 720 2000 L1/2 450 450 L1/2 1320 2500 L1/2 450 450 L1/2 1320 3000 L1/2 450 450 L1/2 1320 * 720 (L1<=1500, 2x18W), 1320 ( L1>1500, 2x36W) WEIGHT (h= mm, kg) L/B 1100 1300 1500 1700 1900 L1 = 1000..3000 1100 86 91 97 107 113 1600 114 119 125 136 141 2100 141 147 152 164 170 2600 169 174 180 193 199 3100 196 202 207 222 228 450 175 9

KVF- DESCRIPTIO 10 3 4 2 4 10 3 11 9 9 11 6 6 1 8 5 7 CODE DESCRIPTIO 1 Outer casing visible parts in stainless steel AISI 304 2 Exhaust air connection and adjustment damper 3 Supply air connection and adjustment damper (type S) 4 Light fixture with electrical junction box 5 Capture Jet nozzles 6 KSA grease filter CODE DESCRIPTIO 7 Grease collection tray or drain tap 8 Personal supply air nozzles 9 Capture Jet fan 10 Capture Jet fan air inlet plenum 11 Perforated front face QUICK SELECTIO DATA L1 (active length) L (section Recommended Exhaust air volume* Recommended make up air volume Capture Jet air volume (with width = 1700) length) l/s m 3 /h H = H = l/s m 3 /h 1500 1600 840 1308 3030 4716 200 l/s or 720 m 3 /h 157 l/s or 565 m 3 /h 44 158 2000 2100 1120 1744 4040... 6288 per linear meter per linear meter 52 188 2500 2600 1 2180 5050 7860 of front face of front face 61 218 5000 5100 2800 4360 10100 15720 S 100% open S 100% open 102 368 7500 7600 4200 6540 15150 23580 Pst = 48 to 52 Pa Pst = 45 to 70 Pa 144 518 10000 10100 5600 8720 20200 31440 186 668 * inimum at a T.A.B. T reading of 50 Pa (505 m 3 /h or 140 l/s per filter)... maximum at a T.A.B. T reading of 120 Pa (786 m 3 /h or 218 l/s per filter) ASSEBLY OF ODULAR SECTIOS KVF- One open end KVF- Two open ends KVF- One open end 10

DIESIOS KVF- (2 closed ends) 25 ote: The dimensions below are for modular sections only; larger canopies are assembled using a combination of separate modules, which makes transportation and site handling easier. W = 1700*..2800 LOCATIO OF COECTIOS (mm) For typical sizes Exhaust Supply Capture Jet Light W = 1700*..2800 1 Ø315 2 Ø315 2Ø250 Ø160 L G I** 1600 L/2 375 W/2 375 L/2 720 2100 L/2 500 W/2 500 L/2 1320 2600 L/2 500 W/2 500 L/2 1320 3100 L/2 500 W/2 500 L/2 1320 ** 720 (L1<=1500, 2x18W), 1320 ( L1>1500, 2x36W) 205 G 50 WEIGHT (h= mm, kg) I L = 1100..3100 L1 = 1000..3000 L/B 1700 1900 2100 2200 2 2600 2800 1100 149 154 159 164 169 174 179 1600 200 205 210 215 220 225 230 2100 251 256 261 266 271 276 281 170 2600 302 307 312 317 322 327 332 3100 353 358 363 368 373 378 383 455 175 50 * Light in the supply plenum from 1700 to 2100 mm 11

DIESIOS KVF- (1 closed end) 1 1 25 ote: The dimensions below are for modular sections only; larger canopies are assembled using a combination of separate modules, which makes transportation and site handling easier. W = 1700*..2800 W = 1700*..2800 I L2 = 1050..3050 L = 1000..3000 LOCATIO OF COECTIOS (mm) For typical sizes Exhaust Supply Capture Jet Light 1 Ø315 2 Ø315 2 Ø250 Ø160 L2 1 1 1 I** 1550 L2/2+25 L2/2-25 375 325 375 325 L2/2+25 720 2050 L2/2+25 L2/2-25 500 450 500 450 L2/2+25 1320 2550 L2/2+25 L2/2-25 500 450 500 450 L2/2+25 1320 3050 L2/2+25 L2/2-25 500 450 500 450 L2/2+25 1320 ** 720 (L1<=1500, 2x18W), 1320 ( L1>1500, 2x36W) 205 W/2 50 WEIGHT (h= mm, kg) L/B 1700 1900 2100 2200 2 2600 2800 1100 149 154 159 164 169 174 179 1600 200 205 210 215 220 225 230 2100 251 256 261 266 271 276 281 170 2600 302 307 312 317 322 327 332 3100 353 358 363 368 373 378 383 455 175 1 * Without light, width can be reduced to 1700 mm 12

DIESIOS KVF- (2 opened ends) 1 1 I 1 1 L1 = 1000..3000 1 25 ote: The dimensions below are for modular sections only; larger canopies are assembled using a combination of separate modules, which makes transportation and site handling easier. W = 1700*..2800 W = 1700*..2800 LOCATIO OF COECTIOS (mm) For typical sizes Exhaust Supply Capture Jet Light 1 Ø315 2 Ø315 2Ø250 Ø160 L1 1 1 G 1 1 I** 1500 L1/2 325 W/2 325 L1/2 720 2000 L1/2 450 W/2 450 L1/2 1320 2500 L1/2 450 W/2 450 L1/2 1320 3000 L1/2 450 W/2 450 L1/2 1320 ** 720 (L1<=1500, 2x18W), 1320 ( L1>1500, 2x36W) 205 G WEIGHT (h= mm, kg) L/B 1700 1900 2100 2200 2 2600 2800 1100 149 154 159 164 169 174 179 170 1600 200 205 210 215 220 225 230 2100 251 256 261 266 271 276 281 2600 302 307 312 317 322 327 332 3100 353 358 363 368 373 378 383 455 175 1 * Without light, width can be reduced to 1700 mm 13