PCH Heating Condensing Module for Air Handling and Roof Top Units

Similar documents
PCH/new Series. High performance, total flexibility

Rapid. Suspended Warm Air Heater. Caring for the environment!

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

AquaKond Split. Caring for the environment! New Condensation Boilers. Efficiency up to 109% 4 Stars. AquaKond 70 kw Standard I.S.P.E.S.L.

Heat Exchanger Module for Industrial Applications

APEN GROUP SPA is a leading manufacturer of heating systems, who is active both in national and international ambits.

C Tahiti. condensing

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

Ciao Green Condensing Wall-Hung Boilers

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

Mynute Green Condensing Wall-Hung Boilers

User, Installation, and Maintenance Manual

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

INSTALLATION AND OPERATION MANUAL

PK-N Floor Standing Heater

CAST IRON ATMOSPHERIC BOILERS

Flue gas condensation...

The mechatronics of EVE 05

RK 50. High Efficiency Condensing Wall Hung Boiler Heating Only. Suitable for Cascade Systems SEDBUK BAND A CE 0694 TA01E011.A0405 TA05E011.

CAMUS. two-pass counter flow fire tube commercial boilers. for hydronic heating and hot water supply TURNDOWN RATIO! HYDRONICS LTD. Rev.

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

Condensing, pre-mixed, wall-hung gas boilers with water tank

VICTRIX 50 1 SPECIFICATIONS. Wall mounted condensing boilers

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

The iqe Boiler Range. Combination and System T Boilers.

ENERGY TOP. Condensing boiler solutions

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Typical Specifications For: ADVANTUS TM DOMESTIC HOT WATER SUPPLY Models AV(W)0500 AV(W)4000

Floor standing boilers. RMG Mk.II RS Mk.II

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

Exclusive Green E Condensing Wall-Hung Boilers

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Power X High Power Condensing Wall-Hung Boilers

white blue cobalt bordeaux light oak (rovere)

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

RIELLO 40 GS/M SERIES

Air curtains. 114 MRX condensing gas air curtain. 118 MRA-H gas air curtain. 121 MRA-A ventilation only air curtain

New Features RIELLO ARRAY. v2.0. High Efficiency Condensing Boiler MBH.

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Condensing Hydronic Boilers 2,000,000-6,000,000 BTU/HR

Power X High Power Condensing Wall-Hung Boilers

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

Wall hung combination

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Eco Angus Wood Pellet Boilers

advanced : technology

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Light oil - kerosene burner

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Max-3 Steel Shell Boiler

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

1 VICTRIX ZEUS Superior kw I features

CONDEXA PRO EXCELLENCE AND VERSATILITY

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

High quality... SEALED PRE-MIXED MODULATING FAN SPECIAL METAL FIBRE BURNER FLAME DETECTION ELECTRODE IGNITION ELECTRODE FLUE OUTLET

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Operating, Installation and Maintenance Manual PRH Warm Air Heater Module 2 stages

Bosch Buderus SSB1000TL/TL2/TL3/TL4 Stainless Steel Condensing Boiler

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 110 ECO RANGE FEATURES AND BENEFITS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

TopGas Wall Hung Condensing Gas Boiler

Warmth, efficiency, and total peace of mind.

Super high efficiency heating and hot water boilers for every type of home and commercial property.

The world s standard in efficiency. CBEX FIRETUBE

Up to 94.6% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL CONDENSING BOILERS OPERATING CONTROL FEATURING A BUILT-IN CASCADING SEQUENCER

Forced draught gas burner

MADE IN ITALY. Quality makes the difference. For 50 years. Product Guide

HIGH EFFICIENCY COMMERCIAL BOILERS

SPECIFICATIONS - NIKE

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

K18 PLANT MANUAL. Heating and DHW

KDE. PRESSURIZED STAINLESS STEEL CONDENSING BOILER FROM 124 kw TO 2160 kw

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

HYDRONIC SOLUTIONS. More than just hydronic boilers, we offer the most efficient integrated hydronic solutions on the market.

Bosch Buderus SSB800/1000/1000TL Stainless Steel Condensing Boiler

Trinity Tft High Efficiency Gas Condensing Boiler & Water Heater

Model FS GTB

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

RTC. Stainless Steel Condensing Floor Standing Boilers Technical data sheet. High efficiency commercial heating

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

The WCGH High Efficiency Commercial Water Heater with Storage Tank

PROPOSED October 15, 2013

VICTRIX Superior kw Export VICTRIX Superior kw X Export

POWERS 24 / 28 / 34 KW

Transcription:

40 Years Caring for Environment PCH Heating Condensing Module for Air Handling and Roof Top Units Efficiency as high as 105% Saving Up to 50% on Consumptions Environmentally friendly

Efficiency as high as 105%? You can! Apen Group has designed and developed PCH heating modules for installation in air handling and roof-top units. PCH modules leverage on pre-mix and modulation technology to exploit condensation and reach efficiency levels as high as 105% according to lower heating value (LHV - Hi). Efficiency % (Hi) 105 102 99 96 93 105,0 % 90 87 PCH Module 89,0 % PCH module is built with environment-friendly, totally recyclable materials, such as steel and aluminium. The heat produced using PCH module's "clean combustion" is earth-friendly and convenient: the burner completely pre-mixes air and gas while the system constantly and logically adapts heat output to changing ambient heating requirements. A microprocessor-based device controls continuous modulation of thermal power output and adjusts it to heat requirements. When modulation of heat output is enabled, an advanced regulating device installed on the main burner monitors and adjusts flow rates of combustion air and gas. Why choosing PCH? CLEAN COMBUSTION Traditional Exchanger PCH condensation modules are equipped with burners that fully premix air and gas. Moreover, a regulating device of heat output is installed. This results in: - No emissions of carbon monoxide (CO = 0). - Very low emission of nitrogen oxides, below 30 parts per million (NOx < 30 ppm). - Low emission of carbon dioxide, due to high combustion efficiency (105%) and to reduction of fuel consumption arising from heat output modulation. SAVINGS UP TO 50% ON FUEL CONSUMPTION! High combustion efficiency, up to 105% (referred to LHV), continuous modulation of heat output, and minimized layering of warm air allow fuel savings ranging from 30% to 50% with comparison to traditional heat exchangers. In addition NO NEED FOR A HEAT PLANT savings on plant building cost (boiler, burner, pumps, safety and regulation devices, masonry work); less space is required (units are smaller and require less clearance); no need for plant certification (our PCH module is already fully certified). NO HYDRAULIC CIRCUIT - NO INTERMEDIATE FLUID: DIRECT HEAT EXCHANGE The heat produced by the heater is directly transferred to ambient air through direct exchange with combustion products. These products flow inside a sealed system, totally separated from the heated environment. No intermediate fluid is required, so the hydraulic circuit is unnecessary and water freezing becomes an out-of-date issue. A few minutes are enough for the environment to warm up thanks to the absence of thermal inertia.

Construction Features Every part of our PCH modules has been attentively designed and carefully tested in Apen Group's R&D Centre to develop and obtain a top-quality, highlyreliable product. ELECTRONIC CARD The microprocessor-based electronic card regulates continuous modulation of heat output and controls both the electrical fan for air/gas mixing and the gas valve. FURNACE Furnace and air/flue exchanger are entirely built with mild stainless steel (with low carbon content) which assures maximum reliability and long life cycle. The drop-shaped furnace and the air/flue exchanger, whose tube bundle is custom designed, guarantee performance that place PCH modules among the leading units for heat efficiency, with an outstanding value of 105%. Drop-shaped furnace 3 5 PREMIX BURNER 6 4 2 The burner is entirely made of AISI 430 steel and undergoes specific engineering processing that guarantee top reliability and high thermal-mechanical performance. 4 1 Control input (0-10 volts) AIR/GAS MIXING: GUARANTEED SAFETY An advanced technique of air/gas mixing guarantees total safety. The gas valve delivers gas according to the air:gas ratio set at the premises. If combustion air fails, the gas valve shuts up. If combustion air decreases, the valve automatically reduces gas flow while maintaining optimal combustion parameters. Working Principles Modulating electronic card PCH modules are designed to serve as heating units into air handling and roof-top systems. They are built to be installed in standalone air handling units: you only need to connect power and gas supplies. Air is heated by contact with furnace and exchanger tube walls. The furnace (1) is fabricated with AISI 430 steel while tube bundle (2) and flue gas hood (3) are made of AISI steel with low carbon content, so as to resist condensate corrosion. Premix gas burner (4) guarantees carbon monoxidefree emissions and a level of nitrogen oxide below 30 parts per million. The electronic card (5) controls the burner and continuously modulates heat output in between min and max capacity. This modulation is based on the regulation parameters set and on the values detected by the unit regulation system. The electronic card includes a 0-10 VDC input and works as a real 3-way valve for water regulation. SAFETY AND CONTROL DEVICES The following devices are installed on PCH modules: 1. Safety thermostat with manual reset and positive safety 2. Electronic ignition device for the burner and ionisation flame control device 3. Ignition and flame detection electrodes

Technical Features CONDENSING exchanger module The AISI 430 steel, drop-shaped furnace maximizes heat exchange and reduces pressure drops CAD DRAWINGS When ordering a PCH module, ask for its size drawings. We supply drawings in CAD format to ease your assembling work of the PCH module into your installation! AISI steel with low carbon content heat exchanger Sealed combustion circuit Efficiency over 105% Hi of LHV Pre-mix gas burner (Class 5), with NOx emissions below 30 ppm and CO rate = 0 Electronic card for continuous capacity modulation. It is controlled by a microprocessor and includes a 0-10 Vdc input. An advanced technique of air/gas mixing guarantees total safety. The gas valve delivers fuel according to the air: gas ratio set at the premises. Safety and control device Safety thermostat and air pressure switch 230V/1ph/50Hz power supply Compliant with all EC existing regulations (EC 0694BM3433 approval) STANDARD ACCESSORIES Conversion kit to LP (Propane) gas. Remote control with lock/reset signals and parameter setting features. Standard PCH module PCH module with installed front panel A Certified System Technical features of PCH module have been thoroughly checked and tested, then they been approved and certified by KIWA GASTEC, the respected and renowned Body for European Certification. By assigning to PCH module the approval number 0694BM3433, KIWA GASTEC has certified that this modules comply with the following Directives: - 90/396/EEC - Directory on appliances burning gaseous fuels 90/392/EEC - Machinery Directive - 72/23/EEC - Low Voltage Directive - 89/336/EEC - Directive on Electromagnetic Compatibility

Fields of application PCH modules can be modularly assembled in order to reach very high thermal outputs. Actually, modules can be assembled in series or parallel installation, according to project requirements. For instance, four PCH092 modules can reach a maximum power output of 368 kw with a modulation field ranging from 368 kw down to a minimum power of 31.5 kw, according to specific needs. The units can be controlled in three ways: Proportionally, by means of an external 0-10 Vdc By means of an ON-OFF switch Incrementally, when more units are installed. PCH modules can also be installed outdoor without any protection. PCH modules are suitable for installations with C- and B-type layout of flue gas exhaust system. Installation Applicazione of more del PCH modulo modules: PCH: one un solo single modulo module con with potenza max output max ranging scelta all interno del seguente from 32 intervallo to 200 kw32 kw - 200kW Installation Applicazione of more del PCH modulo modules: PCH: two due modules moduli in (92 serie kw ciascuno each) installed di 92 in kw, series con potenza with total max max complessiva power of 184 di 184 kw. kw Applicazione Installation del of modulo more PCH: modules: quattro moduli four modules in parallelo/serie (92 kw each) di installed 92 kw ciascuno, in parallel/series con potenza with max total complessiva max power di of 368 368 kwkw.

Technical Data Model PCH032 PCH035 PCH043 PCH054 EC Approval PIN 0694BM3433 0694BM3433 0694BM3433 0694BM3433 Rated Heat Input kw min 10,1 11,3 14,8 15,5 max 34,8 38,8 47,5 58,0 Rated Heat Output kw min 10,2 11,7 15,5 16,3 max 32,8 36,5 44,8 54,0 Efficiency (on Hi) max 101,0% 103,5% 105,0% 105,0% min 94,1% 94,1% 94,3% 93,1% Air Flow Rate m 3 /h (*) min 1900 2100 2600 3100 max 6000 6700 8200 10100 Max Applicable Pressure Pa 1200 1200 1200 1200 Ø of Inlet Air/Flue Exhaust Pipe mm 80/80 80/80 80/80 80/80 Available Pressure on Flue Exhaust Pa 70 80 120 120 Supply Voltage V/hz 230/50 230/50 230/50 230/50 IP Protection Level IP4xD IP4xD IP4xD IP4xD Limit ambient temperature C -15 + 60-15 + 60-15 + 60-15 + 60 Modello PCH072 PCH092 PCH150 PCH200 EC Approval PIN 0694BM3433 0694BM3433 0694BM3433 0694BM3433 Rated Heat Input kw min 22,0 30,0 44,0 53,0 max 78,0 98,0 155,0 215,0 Rated Heat Output kw min 23,1 31,5 46,3 55,7 max 73,2 93,4 145,0 197,0 Efficiency (on Hi) max 105,0% 105,0% 105,2% 105,1% min 93,8% 95,3% 93,5% 91,6% Air Flow Rate m 3 /h (*) min 4200 5400 8500 11500 max 13700 17200 27700 37600 Max Applicable Pressure Pa 1200 1200 1200 1200 Ø of Inlet Air/Flue Exhaust Pipe mm 100/100 100/100 130/130 130/130 Available Pressure on Flue Exhaust Pa 120 120 100 140 Supply Voltage V/hz 230/50 230/50 230/50 230/50 IP Protection Level IP4xD IP4xD IP4xD IP4xD Limit ambient temperature C -15 + 60-15 + 60-15 + 60-15 + 60 (*) Max. air flow calculated on approximate value of T=15 C. Min. air flow calculated on approximate value of T=50 C.

Dimensions Model L(2) B(3) H(3) B1(2) H1(2) L1(1) L2(1) L3(3) H2(1) H3(2) H4(3) H5(3) B2(3) PCH032 900 713 833 650 722 505 335 25 530 95 32 79 32 PCH035 900 713 833 650 722 505 335 25 530 95 32 79 32 PCH043 1230 713 833 650 722 860 335 25 530 95 32 79 32 PCH054 1230 713 833 650 722 860 335 25 530 95 32 79 32 PCH072 1370 798 898 735 788 1050 310 25 610 90 32 79 32 PCH092 1950 798 898 735 788 1590 310 25 610 90 32 79 32 PCH150 1970 978 1108 920 1012 1568 377 25 870 71 29 68 29 PCH200 1970 978 1108 920 1012 1568 377 25 870 71 29 68 29 (1) Fixed dimensions. (2) Minimum dimensions. They can be increased by installing spacers or panels. (3) Minimum dimensions. They can change upon client request. B H3 L1 L2 H4 H H1 H2 H5 Front view H3 Side view L Note: Heat flow can be leftward or rightward oriented without changing PCH exchanger position. B1 B2 B2 L3

40 Years Caring for Environment Energy Savings: a Must in our History The wealth of expertise gained by APEN GROUP over the past forty years in the field of heating and air handling has won the Company its design and engineering leadership. Our mission is to constantly focus on designing, manufacturing and marketing top-quality products for heating and air handling. We are therefore paying the utmost attention to environmental issues, by developing products that guarantee low polluting emissions, high efficiency levels and reduce energy consumption. Certified Quality In February 2003, Apen Group's quality standards have been certified according to UNI EN ISO 9001:2000 standards as regards to design, manufacturing, marketing, and service of warm air heaters, condensing heaters and exchangers, gas convectors, air handling units, burners, and boilers." This certification is another important goal reached by the Company, whose compliance to ISO registration standards dates back to 1991, on its path to fulfilling its mission: Quality, Safety, and Care for the Environment. Technology applied to Research and Manufacturing A highly trained team of skilled designers and researchers follows each step of product design and implements leading-edge technical and manufacturing solutions. The manufacturing of our products takes advantage of ultimate, state-of-the-art planning and organization methods, which include: digital control equipment, welding robots, computer-assisted machinery, and high automation in order to deliver top quality, manufacturing flexibility and timely deliveries. Innovation, reliability, and originality are built-in features of each of our products. Customer Service 350 Customer Service Centres are dedicated to support the client and solve as quickly as possible any problem that may arise with APEN GROUP products. Our skilled technicians guarantee professional support and full assistance for the management and maintenance of our equipment. A 40-year-long experience in the field of air heating and handling technology Visit our website: www.apengroup.com APEN GROUP s.p.a. 20060 Pessano con Bornago (MI) - Italy - Via Provinciale, 85 Tel. +39-02-95.96.93.1 Fax +39-02-95.74.27.58 www.apengroup.com apen@apengroup.com Cod. X00851IT ed 07/02 - APENGROUP si riserva eventuali variazioni senza obbligo di preavviso.