Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Similar documents
ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

ZIP VARIPOINT II Direct unvented water heaters.

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

T550i power shower pump Installation and operating instructions

Unvented Electric Water Heater 10/15 litre Undersink

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

MEGAFLO HE Iss 1

ZIP Aquapoint III. Direct unvented water heaters Models: AP3/05, AP3/05/OB, AP3/10, AP3/10/OB, AP3/15, AP3/15/OB.

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Zip Chillmaster Floor Mounted Chiller

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Hotflo. Unvented point of use hot water

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Installation Instructions Flute Tap Range

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Installation Instructions and User Guide Thermostatic Recessed Dual Control Shower Valve

OPERATING & MAINTENANCE INSTRUCTIONS FOR EXHEAT RFA-OS TYPE FLAMEPROOF OVERSINK WATER HEATER

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Unvented Direct & Indirect Hot Water Cylinders (400L L)

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

HOTFLO 10 / 15. Fitting Instructions and User Guide

PERFORMANCE SHOWER PRODUCTS

HEAVY DUTY BRASS SHOWER PUMPS

SEALED THERMAL STORE

Thermostatic Concealed Shower Valve

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Installation and User Instructions HS10U, HS15U.

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Manual / Handbuch Spare parts list / Ersatzteilliste

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Beeline Monobloc Kitchen Mixer Tap

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Unvented Direct & Indirect Hot Water Cylinders (400L L)

SUPREME 140, 155, 170

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

SPEEDIBOIL Installation and User Instructions. Models: SP2.5, SP5.0, SP7.5

Installation, Operating and Servicing Instructions

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Installation & User Instructions

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

Unvented water heating

Pear Kitchen Sink Tap

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

CROMO manual mixer shower

SPEEDIBOIL Installation and User Instructions

SMART SHOWERS ELITE SP P0985 READ ME THIS IS A HIGH PERFORMANCE HIGH SPECIFICATION PUMP AND HAS PRECISE INSTALLATION REQUIREMENTS

THERMOSTATIC SHOWER VALVE

User and Installation Instructions. Electric Auto-Fill Water Boilers EB3F, EB4F, EB6F, EB6TF IS339 ECN3539

Bath Shower Mixer

NENE. Installation and Operating Instructions. Thermostatic bar mixer shower PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Speedflow Undersink Unvented Water Heater. Models SF05K, SF10K and SF15K. Instruction Manual

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Streamline Undersink. Fitting Instructions and User Guide

Thermostatic Shower Tower Installation and Operating Instructions

Dene Bath Shower Mixer

ADVANCE ECB ELECTRIC COMBINATION BOILER

The Professional s Choice

METRO BASIN MONO MIXER CHR

HOTFLO 10 / 15. Fitting Instructions and User Guide

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

X62 Tap Range. Please keep these instructions for future reference

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Thermostatic bar mixer shower. Installation and Operating Instructions. Installers please note these instructions are to be left with the user

TYNE. Installation and Operating Instructions. Thermostatic bar mixer shower. Installers please note these instructions are to be left with the user

AIRE. Thermostatic bath shower mixer. Installation and Operating Instructions INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

Cistern-fed water heating

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

Sema thermostatic bar mixer Installation and operating instructions

Oltis thermostatic bar mixer

Aquatap (Boil only) Installation and user manual

Dual Control Concealed & Exposed Thermostatic Shower Valve

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve with Integral Diverter

Zip Autoboil Installation and Operating Instructions

INSTANTANEOUS ELECTRIC SHOWER

Target Monobloc Kitchen Mixer Chrome

PACK CONTENTS WARNING. This water heater must only be installed by qualified persons.

Alpha CombiMax 350 and 600

ADVANCE ELECTRIC THERMAL STORE

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

WC2 & WC3 Installation & Maintenance Instructions

Transcription:

Contents Product Description 2 Approvals 2 Warranty 2 Warnings 2 Technical Specification 3 Installation 4 Location 4 Plumbing Connection 4 Electrical connection 5 Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9 These instructions should be read carefully and understood before commencing the installation. Do not proceed if any part is unclear or if requirements cannot be fully met. Please leave these instructions with the users after installation. Zip RCH Water Heater Installation and User Instructions 1

Product Description The Zip RCH series is a range of cistern fed rectangular water storage heaters. They can be connected directly to the cold water main and can supply more than one outlet without the need for special taps. Approvals The RHC series has been examined, tested and found, when correctly installed, to comply with the requirements of the United Kingdom Water Regulations/Bylaws (Scotland). The product, therefore, is listed under the WRAS (Water Regulations Advisory Scheme) Water Fitting and Materials Directory - Certificate No. 0007085. The RCH series is CE endorsed. Warranty Your RCH is precision built from the finest materials and should give many years of trouble free service. Zip heaters (UK) Ltd. warrants that should any part of the heater fail within one (1) calendar year of installation, that part will be repaired or replaced by Zip Heaters (UK) Ltd. free of charge, except as set out below, provided that the failure is not due to accident, misuse, abuse, condition of the water, frost, or failure to follow installation instructions or service requirements. The only charges payable by the customer are the cost of removal, re-installation and cartage, should any component need to be returned for repair. This warranty does not cover damage resulting from nonoperation or consequential damage to any goods, furnishings or property. This warranty does not displace any statutory warranty in relation to the RHC. Zip Heaters (UK) Ltd s. liability under any statutory warranty will be limited to replacement or repair at the option of Zip Heaters (UK) Ltd. Warnings The unit MUST NOT be used if it is suspected of being frozen. If water ceases to flow, switch off the electricity supply immediately at the isolating switch. If the unit is to be serviced or drained, disconnect the electricity supply before commencing the operation. 2 Zip RCH Water Heater Installation and User Instructions

Specification Product: Type: Capacity: Loading: RCH Rectangular cistern-type heater 25ltr. 50ltr. 75ltr. 100ltr. 3.0 kw, 6kW option available on 100ltr. model. Heating Element: Embedded rod type. Thermostat: Water Tank: Case: Insulation: Safety Cutout: Approvals: Adjustable rod type, range 5 C to 65 C. Hot water tank and cold water feed cistern are both manufactured from copper sheet with brazed seams. White enamelled corrosion proofed steel. Fully fire retardant foiled urethane core slab. Resettable rod type thermostat factory set at 80 C. CE endorsed - WRAS approved. Dimensions Product Capacity (litres) Dimensions (mm) Weight (kg s) Ref Hot Cold A B C D E F Empty Full RCH25 25 8 705 470 735 210 670 320 20 53 RCH50 50 24 750 600 760 320 715 450 32 106 RCH75 75 24 925 600 950 320 890 450 37 136 RCH100 100 24 1080 600 1110 320 1045 450 40 164 Fig.1 Zip RCH Water Heater Installation and User Instructions 3

Installation 1. Location The unit must be wall mounted allowing at least one metre above the highest draw off point. This will ensure good flow. Sufficient clearance must be allowed to ensure access to the ball valve assembly, through the top of the heater. The wall fixing points are designed to accept 8mm bolts, which should not be less than 50mm in length. Always ensure that the wall is strong enough to carry the weight of the unit when full of water. You will need mains cold water supply via 15mm pipe. The overflow system will accept 21.5mm ( 3 /4 ) pipe. 240v 13amp electrical supply should be available. 2. Pipework Connections (Refer to Fig. 2) The installation must conform to any local authority byelaws. The cold water supply and overflow pipe assembly can be connected to either side of the unit. The respective apertures are pre-formed in the outer case and should be used as guides for cutting through the cold water tank. A 22mm hole saw is required for the inlet and a 27mm hole saw for the overflow. An isolating valve must be fitted to the cold water mains supply to allow for servicing. Diagram Fig.2 Filter & Breather assembly Vent Pipe Inlet Elbow Warning Pipe Screen Overflow Dip Tube Mains cold water in Hot water out 3. Fitting to the Cold Water Tank The Zip RCH series of water heaters are supplied with all the components that are required to comply with the WRAS byelaw 30. The arrangement of these should conform to fig. 2. The filter and breather assembly is a push-fit connection and should be fitted to the lid in the aperture provided. 4 Zip RCH Water Heater Installation and User Instructions

The overflow assembly comprises three components. 1. The threaded elbow (tank connector) is inserted through the hole that has been cut, and tightened with the nut and sealing washer on the inside of the tank. 2. The 90 internal dip tube is pushed firmly into the connector facing downwards.the overflow is located securely into the downwards external connection of the connector. 3. The ball valve assembly is fitted as required, adjusting the float to ensure that the water level in the tank does not exceed the water level line. NOTE: After installation, replace the lid and secure with the retaining screw supplied. 4. Electrical Connection The installation should be carried out by a suitably qualified person in accordance with BS7671 (lee) wiring regulations. A double pole isolation switch, having a contact separation of greater than 3mm, should be fitted to allow for servicing. The Zip RCH II series of water heaters are all fitted with a 3 kw heating element. (6kw available for 100 ltr.) The heating element is located beneath the element housing cover at the base of the unit. The heating element assembly incorporates dual thermostats that are linked to act as a control thermostat with an over-temperature safety cut-out. The thermostats are factory fitted set to 60 C for the control thermostat and 80 C for the cut-out thermostat. The control thermostat should NOT exceed 60 C and the 20 C differential between the control and the cut-out thermostat MUST be maintained. The supply cable should be securely clamped before replacing the heating unit s own cover AND as it passes through the gland in the element housing cover. Schematic Wiring Diagram Note: Do not switch on until the unit is full of water and ready for commissioning Zip RCH Water Heater Installation and User Instructions 5

Commissioning IMPORTANT To ensure that sufficient water is covering the element before switching on, the unit MUST have water flowing from the taps. After the plumbing connections are made and before making the connection to the electrical mains supply, fill the unit with water and check each joint thoroughly for leaks. Also check the element and drain connections as these may have become loosened in transit. Once you are satisfied that all the joints are secure connection may be made to the mains electrical supply. Operation The cold water supply to the integral cistern is controlled by the ball valve. When one or more hot taps are opened the hot water drawn off from the unit is replaced from the contents of the cold-water cistern that is refilled automatically. Routine Preventative Maintenance The ZIP RCH is fitted with a mechanical ball valve and it is recommended that this should be checked on a regular basis. The following checks should be made: a) That the ball valve mechanism is free from obstruction i.e. scale. b) That the ball valve is moving freely up & down with the water level. c) That the plastic float has not taken on any water. d) That the ball valve is shutting off when the water is at the correct level. If there is evidence of scale within the cistern tank this should be cleared to ensure continued safe operation of the ball valve mechanism. In the event that the main tank requires de-scaling the unit should be drained, the element assembly removed, the scale can now be manually removed. In the event of an element failure ensure that the unit is completely drained before attempting to remove the old element. Before carrying out any work on the thermostat or the element please ensure that the elecricity supply is switched off. 6 Zip RCH Water Heater Installation and User Instructions

Fault Finding Fault No Hot Water N.B.* these could be linked - in the event of control stat failure cutout will activate. Water too hot No water from taps. Leaking Diagnosis Incorrect control thermostat setting. *Over temperature safety cutout tripped. *Control thermostat faulty. Element failure. Incorrect control thermostat setting. Thermostat wired incorrectly Faulty thermostat. Ball valve malfunction. Outlet blocked by scale. Tap/s faulty. Poor seal around the element. Poor seal around the drain cock. Drain cock not fully closed. Poor inlet/overflow connection to cistern tank. Inlet elbow on the ball valve is not positioned so that the water flows directly into the tank. Condensation forming on underside of the lid and dripping down between the inner vessel and outer case. Cylinder holed. Action Check setting and adjust as required. Reset and check operation of the thermostat. Replace thermostat. Replace element. Check setting and adjust as required. Check wiring and correct if necessary. Replace thermostat. Check operation and replace if necessary. Disconnect outlet and clear blockage. Check operation of tap, if faulty contact the tap manufacturer for spares. Remove and re-seal. Remove and re-seal. Tighten drain cock until fully closed. Remove and re-seal. Turn elbow so that the water flows directly into the tank. Check for water droplets forming on the underside of lid, if present then apply a sealant around the top of the unit. Contact Zip on 0870 608 8888 Zip RCH Water Heater Installation and User Instructions 7

Spare Parts Zip RCH Item Part No. Description 1 RC0400 Element 3kW C/W Gasket & Two Thermostats 2 RC0403 Control Thermostat 11 3 RC0404 Resettable Thermostat 11 4 RC0405 Element Gasket 5 RC0406 Outlet Nut & Olive 6 RC0410 Ball Valve 7 RC0411 Float 8 RC0400/2 Element 2kW C/W Gasket & Two Thermostats 9 RC0400/6 Element 6kW C/W Gasket & Two Thermostats Technical Support Should technical assistance be required, please contact the Customer Care Centre on- Tel: 0870 608 8888 Fax: 01362 692448 e-mail: service@zipheaters.co.uk with the details of the problem and stating the information in the box below. *Model No. *Serial No. Date of Installation *To be found on the data label on the underside of the unit. Please complete this box at the time of installation. For claims under guarantee you may be asked to provide proof of purchase 8 Zip RCH Water Heater Installation and User Instructions