Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Similar documents
Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Illuminated Stopper Station Push Button

EPO STATION. EPO Station with push to activate, turn to reset button complete with a clear cover to help

Stopper II Heated Enclosure

SPECIFICATIONS. Contents List

Stopper II SERIES ADA. We protect the things that protect you

Exit Stopper. STI-6400 Series

Exit Stopper. STI-6400 Series

Addendum for STI-6406 with Dual Access Control

Protective Cabinet STI-7534, STI-7535 and STI-7535AED

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

Installation Instructions

200i User s information manual

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

Installation and ZONES: Operation Manual. Model: ON STI-34108

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions

FES - Series Portable Electric Heaters

Installation Instructions If you have questions, call or visit our website at:

QAA 142 Termination instructions Self-regulating trace heaters type ELSR-NA and -HA in Div1 with heater entry kit EL-HAZELECT Kit part No: 09CA051

GARAGE DOOR OPENER KIT

Installation Instructions If you have questions, call or visit our website at:

INSTALLATION INSTRUCTION In-Ground Color Changing

SOLA SM II Light Engine Instruction Manual

Lumination TM Volumetric Retrofit Kit

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

INSTALLATION INSTRUCTION In-Ground

Installation Instructions If you have questions, call or visit our website at:

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

Installation Instructions

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Occupancy Sensor OCS 100W Setup Guide

Lumination TM Controls Accessory LPL Series Controller Box

Instruction Manual Advanced Mini Block Heaters Advanced Mini Block Heater with Heated Lid

Operating Instruction Manual

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

SERIES PSCII GAS BOILERS

GE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900

AGA TOTAL CONTROL. Model No. - TC3

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Installation Instructions

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

Operating Instruction Manual

Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation

Operation & Care Instructions Save For Future Reference ABOUT THE MACHINE

BruteTM. User s Manual for. Modulating Boiler Model BNTH Sizes MBTU/h. Water Heater Model BNTV Sizes MBTU/h. with Touchscreen Display

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

User s Manual for FT SERIES THE

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

Installation, Operation and Maintenance Manual

Wireless Outdoor Air Reset Adaptor PN:

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

Instruction Manual Standard Dry Block Heaters Advanced Dry Block Heaters U L

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1

Installation Instructions

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780

Installation, Operation and Maintenance Manual

Mascot LX. User s Information for. Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH

Operating Instruction Manual

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

MICROWAVE OVEN UNDER-THE-CABINET INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION FOUR À MICRO-ONDES SOUS PLACARD MURAL

Wi-Fi DOOR/WINDOW SENSOR

Instruction Manual Round Top Hotplate-Stirrers. Advanced Unit

520 Series. AngleMix Thermostatic mixing valve NA Function

PH:

Kit Instructions COMMON VENT KIT (PVC AND DURAVENT)

Aquatron 4, 8, /95 Form Number Instructions For Use. Advance Models , , , ,

PH:

Design Guide with Installation Instructions

Concerning the use of GP4000 Series Graphic Operator Interface for applications in potentially explosive atmospheres (Zones 2/22)

Technical Manual for the Strobe - SM87 HXB

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

PDD-FT-3. Fire Panel Interface With EOL Trigger. Installation and Specifications Manual

Vulcan Fire Module WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

Installation Instructions

SOLA SM and SOLA SM 365 Light Engine Instruction Manual

Switching power supply. Additional Information on page 2 Input rating: Vac, 50-60Hz, 2.5A Output rating: 24Vdc, 8.33A max., 200W max.

Location Requirements

Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

GE Monogram. Installation. Instructions. Stainless Steel Built-In Refrigerators. Models ZISS36D SS, ZISS36N SS ZISS42D SS, ZISS42N SS

Installation Instructions

1752 Pond Vac D A B A E G C H I J F

Installation Instruction Danfoss RX-C Roof and Gutter De-Icing System

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

GBX GAS BOILERS USER S INFORMATION MANUAL

LED Dusk to Down Fixture

Draft - develop and review

INNCOM e7 Thermostat Installation Instructions FOR ALL UNITS IN CARTON. DO NOT THROW AWAY!

Service Procedures for the Model SL31-31 Dryer

520 Series. TankMixer water heater tank mixing valve NA Function

Escape Series Walk-in Bathtub Models 5128 and 5332 (soaker, water, air and microbubble jet models)

SPREMIAGRUMI MANUALE D USO E MANUTENZIONE

Transcription:

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button ADA for operation Pneumatic Timer Models SS-2008 Red SS-2108 Green SS-2208 Yellow SS-2308 White SS-2408 Blue ALL MODELS COME WITH A COLOR MATCHED SURFACE MOUNT BACKBOX We protect the things that protect you.

This push button has been tested according to UL38 and UL2017. Manual fire alarm stations are listed in UL category UNIU and non-fire alarm initiating devices are listed in UL category UEHX. It is important to read, understand and follow all instructions provided with this product. It is the installer s responsibility to comply with NFPA72 and 101, NEC, mounting specifications according to ADA and other applicable fire and electrical codes. After installation and testing are complete, provide a copy of this manual to all personnel responsible for testing and maintenance of this product. To avoid electrical shock, DO NOT attempt to install this product when power is on. * For access control installations, power for the SS-2008 must be supplied by a power source Listed to UL294. When used for access control, this device shall be used as a part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security installations, lower time limits should be used. L essai de ce bouton-poussoir a été réalisé selon UL38 et UL2017. Les avertisseurs d alerte d incendie manuels sont répertoriés sous la catégorie UL UNIU tandis que les dispositifs de déclenchement d alertes non incendie sont répertoriés sous la catégorie UL UEHX. Il est important de lire, de comprendre et de suivre toutes les instructions fournies avec ce produit. Il incombe à l installateur de se conformer aux normes NFPA72 et 101, NEC, aux spécifications de montage selon l ADA et aux autres codes de prévention des incendies et de l électricité en vigueur. Pour éviter un choc électrique, NE tentez PAS d installer ce produit lorsqu il est sous tension. Une fois l installation et les essais terminés, vous devez fournir une copie de ce manuel à l ensemble du personnel chargé de l essai et de l entretien de ce produit. * Pour les installations de contrôle d accès, l alimentation SS-2008 doit être fournie par une source homologuée UL294. Lorsque cet appareil est utilisé aux fins de contrôle d accès, il doit faire partie d un système de porte de sortie à accès contrôlé. Il incombe donc à l AHJ local d autoriser l utilisation de cet appareil au lieu d un capteur automatique. Pour les installations de sécurité plus renforcée, des délais inférieurs doivent être utilisés. - 2 -

Installation and Service Instructions STOPPER STATION SERIES SS-2008 PUSH BUTTON PNEUMATIC TIMER SAFETY NOTICE TO INSTALLERS AND USERS I. GENERAL Product Dimensions See page 3 Contact Rating One set NO and one set NC Rated at 10 AMP @ 240 VAC Recognized component listing is 1,000,000 cycles UL File #UL57255 Operating Temperature of button 15-120 F (-9 to +49 C II. CONTENTS LIST QTY. DESCRIPTION 1 Push Button Housing Assembly 1 19001 Allen Head Screw #8-32 x 3/8 in. 1 19015 Allen Wrench 3/32 in. 4 19068 #6 x 5/8 in. hi-low screw 2 19060 Screw #6-32 x 1 in. 1 19021 Ground Screw 4 19039 #6 x 1 1/4 in. SS SMS 4 19018 Plastic Screw Anchor 1 71100A Surface Backbox III. INSTRUCTIONS Product Dimensions... Page 3 Front Housing Removal... Page 3 Backbox Preparation... Page 4 Switch Contact Diagram... Page 5 Switch Data... Page 5 Installation... Page 6 Warranty... Page 7-3 -

PRODUCT DIMENSIONS 3.25 in. (82mm) 1.62 in. (41mm) 1.58 in. (40mm) PUSH 4.87 in. (124mm) 1.375 in. (35mm) VIEW SHOWING FRONT HOUSING REMOVAL BUTTON AND SWITCH ASSEMBLY 10271 SWITCH HOUSING RED, GREEN, YELLOW, WHITE AND BLUE 19011 SCREW ALLEN HEAD #8-32 x 3/8 (1) PROVIDED 19015 WRENCH (1) PROVIDED - 4 -

BACKBOX PREPARATION (NOT INCLUDED WITH FLUSH MOUNT COVERS) DRILL POINT LOCATIONS PROVIDED TOP AND BOTTOM FOR 1/2 in. CONDUIT FITTINGS. DRILL AS NEEDED FIELD DRILLING FOR CONDUIT ENTRY IS REQUIRED. LOCATIONS SHOWN ALSO APPLY TO OPPOSITE, PARALLEL SIDES. J J H SWITCH BACKPLATE MOUNTING HOLES J BOX MUST BE INSTALLED WITH ARROWS POINTING UPWARD H THESE HOLES MUST BE J DRILLED OUT USING A 5/32 in. DRILL BIT - 5 -

CONTACT DIAGRAM (BLACK) NC (RED) NO NC (GREEN) NO (WHITE) LEAD WIRE COLORS IN PARENTHESIS. CONTACTS One set NO and one set NC NC NO NC NO SWITCH INFORMATION COUNTERCLOCKWISE CLOCKWISE TIMER RANGE ADJUSTMENT SCREW ADJUSTMENT RANGE - 2 TO 60 SECONDS TIMER FACTORY SET TO MINIMUM TIME SETTING. TO INCREASE TIME, TURN SCREW CLOCKWISE IN 1/4 TURN INCREMENTS. WHEN CLOSE TO DESIRED TIME, TURN SCREW IN VERY FINE INCREMENTS TO DESIRED SETTING. CAUTION: OVER-TIGHTENING MAY CAUSE DAMAGE TO TIMER. - 6 -

INSTALLATION 19018 ANCHOR (4) PROVIDED 71100A-COLOR SURFACE BOX WITH PROVIDED SURFACE BACKBOX DRILL (4) 3/16 in. DIA HOLES 19039 SCREW #6 x 1-1/4 in. (4) PROVIDED 19060 SCREW #6-32 x 1 in. (2) PROVIDED 19021 GROUND SCREW BUTTON AND SWITCH ASSEMBLY CAN BE INSTALLED ON ANY EXISTING SINGLE GANG BOX TYPICAL FLUSH MOUNT GANG BOX 19021 GROUND LUG (2) PROVIDED WITHOUT PROVIDED SURFACE BACKBOX INSTALLATION NOTE ADA mounting compliance requires the operable part of the initiating device shall not be less than 1.1m (3 1/2 ft.) or greater than 1.37m (4 1/2 ft.) above finished floor service. 19060 SCREW #6-32 X 1 (2) PROVIDED BUTTON AND SWITCH ASSEMBLY - 7 -

Warranty Three year guarantee against breakage of polycarbonate in normal use (one year on electro mechanical and electronic components). Electronic warranty form at www.sti-usa.com/wc14. 2306 Airport Rd Waterford, MI 48327 Phone: 248-673-9898 Fax: 248-673-1246 800-888-4STI (4784) www.sti-usa.com Safety Technology International (Europe) Ltd. Unit 49G Pipers Road Park Farm Industrial Estate Redditch Worcestershire B98 0HU England Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 E-mail: info@sti-europe.com Web: www.sti-europe.com 2008 A-IS 02/04