Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

Similar documents
SECTION AIR DUCT ACCESSORIES

AIR DISTRIBUTION DEVICES & DUCT ACCESSORIES EXPERTS OF AIR TECHNOLOGY

SECTION AIR OUTLETS AND INLETS

FIRE & SMOKE DAMPERS. Meeting tomorrow's requirements for fire and smoke protection today.

D. Fabrication: Steel or Aluminum with baked enamel off-white finish. B. Type: Square and rectangular, adjustable pattern, multi-louvered diffuser.

SECTION (15820) - AIR DUCT ACCESSORIES

AIR DUCT ACCESSORIES

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION DUCTWORK

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

lindab we simplify construction LindabIndoorClimateSolutions Product overview Grilles

Life Safety Dampers Selection and Application Manual

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

SECTION (15833) - HVAC POWER VENTILATORS

INSTALLATION DO S AND DON TS

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

SECTION DUCTWORK

Displacement Ventilation

CONTENTS. B. System Design and Performance Requirements

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

B. System Design and Performance Requirements

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Basic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives

Double Skin Air Handling Units

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Centeral Station Air Handling Unit

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

INSTALLATION INSTRUCTIONS WALL MOUNT LINER INSERT

Cabinet Unit Heaters Steam / Hot Water

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

SECTION AIR HANDLING UNIT

DIVISION 15 MECHANICAL

set 2 i) For meeting room on ninth floor, - Cooling capacity = 6.4Kw (2 pieces to 1 outdoor unit)

Linear Floor Heaters

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Ceiling diffusers. Type DLQL

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

Tunnel Transit Dampers Heavy Duty Tunnel Transit Life Safety

GUIDELINES FOR HIGHRISE BUILDING CONSTRUCTION PROJECTS (MECHANICAL VENTILATION)

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

PDH & Professional Training

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

EXHAUST FAN SCHEDULE

A. General: Refer to paragraph entitled "SUBMITTAL" in Section Include the following data:

VentZone Systems VentZone Zoned IAQ with Heat Recovery Kits

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

Engineering Guide VAV Diffusers. Please refer to the Price Engineer s HVAC Handbook for more information on VAV Diffusers.

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

VentZone Systems VentZone Zoned IAQ with Energy Recovery Kits

1.1 This section applies to air handling units for HVAC Systems.

Convectors Steam / Hot Water November, 2009

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

ENVIRO UNIT ENGINEERING MANUAL KES SERIES

Tunnel Transit Dampers. Heavy Duty Tunnel Transit Life Safety

Double Skin Air Handling Units

Fire dampers. For diverse applications

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

DACC Health Sciences Building Air Handler Assessment/Study

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

VERSO Air Handling Units

Technical Selection. elevent ceiling diffusers. Swirl, Jet, Louvred and Curved ceiling diffusers

VERTICAL FAN COIL UNITS

Lenntech. Tel Fax

Type FKS-EU COMPACT DIMENSIONS, IDEAL FOR RESTRICTED SPACES. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FKS-EU

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

AIR HANDLING. B. Section Building Automation and Control System Guidelines. C. Section Air Cleaning Devices and Filters

Bulletin C6200 MAY Buffalo. Big Buffalo. Air Handling. Custom Applications

AIR TERMINALS & DUCT HEATERS.

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Prodotti > Protezione dal fuoco e dal fumo > Serranda tagliafuoco > Type FK-EU

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Modular Supply Make-Up Air Unit

Chore-Time Fan Guide For Tunnel and Other Applications

The Corona air inlet TECHNICAL SPECIFICATIONS

INDUSTRIAL BLOWERS. With over 70 years of experience and expertise our fans will ensure your projects are a success.

The PV100x fans feature Class F motor insulation. 5 year fan housing and motor warranty

BES-TECH TECHNOLOGY & SYSTEM INTEGRATION


Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

CONDOR. Supply air ceiling QUICK FACTS

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Twin City Fan & Blower

and SHUTTERS Made to Work. Built to Last.

A. This Section includes air-handling units with coils for indoor installations.

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

ATC Heating Devices. P. 1 ATC Heating Devices

Modular Heating & Ventilating Unit Model IGX-HV

Agitation and Mixing

Gravity and Pneumatic Waste and Linen Handling Systems NFPA 82 Inspection Form

Transcription:

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and rectangular type with one, two, three or four way patterns. MODELS: SCD: Supply ceiling diffuser. RCD: Return ceiling diffuser.

Linear Slot Diffusers : Frame and Curved deflection blades are made of extruded aluminum alloy 6063 to T6 heat treatment. Available with GI sheet to control air flow patterns. MODELS: SLD: Supply Linear diffuser. RLD: Return Linear diffuser

Linear Bar Grills : SAMA Linear bar grille " single deflection " is wall mounted grille, used as supply or return grille in cooling, heating or ventilation applications. The single deflections linear grille is composed of a set of fixed horizontal straight bars attached to frame, both manufactured from extruded aluminum sections. MODELS: SLBG: Supply linear bar grille. RLBG: Return linear bar grille. SLRG: Supply linear Register. RLRG: Return linear Register

Supply Air Grille & Registers : The single deflection air grill is composed of a set of deflecting blades mounted on a rectangular shaped frames. The double deflection air grille is composed two sets of deflecting blades mounted in two adjacent planes. The two sets of deflecting blades are mounted in such a way that one set is vertically mounted and the other set is horizontally mounted. The single and double deflection air grille are used for cooling, heating or air ventilation. MODELS: SAG D/D ( With Damper ) SAG S/D ( With Damper ) SAG D/D ( Without Damper ) SAG S/D (Without Damper )

Fixed Blade: SAMA fixed blade is composed of a set of horizontally mounted fixed blades that are made of extruded aluminum. MODELS: FBH FBV FBRV

Round Diffuser : Fully adjustable air discharge pattern horizontal vertical, for spot cooling, heating and ventilating application. Removable inner core assembly for easy installation. Aluminum construction. Standard color RAL9016. MODELS : SRCD: Supply Round Ceiling diffuser. RRCD: Return Round Ceiling diffuser.

Jet Diffuser : Aluminum construction with extruded aluminum frame. Adjustable core provide air discharge up to 30 degree from the mid position in any plane. Single element provide direct connection to round duct system. MODEL : JD: Jet diffuser.

Disc Valve : Air flow rate can be controlled by rotating the central disc. Central disc is fixed by locking nut. Face galvanized steel. Spindle and locking nut galvanized steel. MODELS : DV: Disc Valve.

Door Grille : SAMA Door grille composed of a set of horizontally V-shape blades mounted with fixed spacing to a frame called the fixed frame. MODELS : DG: Door Grille.

Egg Crate : SAMA Egg Crate frame made of extruded aluminum and core of square aluminum sheet standard color white powder coating to ( RAL 9016 or 9010 ). MODELS: EC: Egg Crate.

Fresh Air Intake & Exhaust Louvers: Air louvers is composed of a set of horizontal mounted fixed blades and inclined down 45 Spaced 35 mm or 50mm on center, blades and frame are manufactured from extruded aluminum Alloy ( 6063-t6 ) designed for both intake and exhaust opening.

Sand Trap Louver: SAMA sand trap louver manufactured for fresh air intake in HVAC systems, which are designed To separated large size sand particles at low air velocities thus avoiding excessive dust Loading performance for air filtration and moderate pressure drops at low air velocities.

Access Door Grilles : The frames are made of extorted aluminum alloy, access door grille core can be fabricate from fixed blade, egg crate and perforated sheets. standard color is white powder coating ( RAL 9016).

Access Door Duct SAMA manufactures Access Doors Duct that are designed for use in central air conditioning ductwork systems to provide access for resetting of Fire Dampers, Heaters, Filters or other maintenance works. The strong and robust construction of the access door guarantees low leakage of air even with high duct pressures. Double walled door panel with mineral wool insulation will act as better resistance for transfer of heat..

Volume Control Damper : Volume control damper is made of multi blades, parallel, and frame is flange type of Galvanized steel construction, hand locking quadrant is provided manual operation, Extended shaft and motor base is provided for motorized operation. the blades are mounted on nylon bushing and operated by external linkage.

Fire Dampers : Fire damper are made of 20 gauge galvanized steel blades are curtain type of gravity shutter without negatron closure spring for static operation or with stainless steel negatron spring for dynamic operation

Fire & Smoke Dampers : Combination fire & smoke damper meet the requirement of safety in HVAC system. FSD consist of a fire damper and smoke damper together as a single damper. FSD is used in HVAC system where a wall, floor or ceiling is celling is required to have both a fire and smoke damper. FSD close up on the detection of heat ( via duct temperature ) or smoke via ( via smoke detector ). FSD is available with electric heat devices instead of fusible links in regular fire damper.

Back Draft Damper : From light operations to heavy-duty industrial applications, SAMA provides the perfect back draft damper. Commercial dampers provide low-pressure openings with excellent pressure-drop performance. The industrial grade back draft dampers offer rugged construction & heavy gage materials to with stand the high velocities & back pressure associated with heavy duty installations. SAMA has developed three types of Back Draft Dampers as following : 1. Light Back Draft Damper. 2. Back Draft Damper. 3. Pressure Relief Damper.

Variable Air Volume (VAV) * Variable Air Volume (VAV) is a type of heating, ventilating, and/or air-conditioning (HVAC) system. Unlike constant air volume systems, which supply a constant airflow at a variable temperature, VAV systems vary the airflow at a constant temperature. * Variable Air Volume Systems are the best way to zone especially in large buildings. A VAV system with the proper controls and set-up will help the building owner realize large savings in energy usage.

Sound Attenuators : Sound attenuators are constructed to the relevant of HVAC ducting work. Casing is 20 gauge galvanized steel. Baffle are made of 20 gauge galvanized steel perforated galvanized steel filled with sound obsorbing material. Flange from steel angle.