LogTag TICT - is0 Tag

Similar documents
PRODUCT SPECIFICATION

LogTag Recorders TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

LogTag Recorders Ltd TRED30-16R. Temperature Recorder with Display and 30 Day Statistics Memory. Product User Guide

USRIC-8(M) USB PDF Temperature Recorder. Product User Guide. LogTag Recorders Ltd

UTRED day Logger with display

UTRED30-WiFi. 30 day WiFi Logger with display

What's new in LogTag Analyzer 2.8

What's new in LogTag Analyzer 2.8

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

EL-USB-1-LCD Temperature Data Logger with LCD

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

iminiplus PDF User Guide Version 2.0

WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

Step-by-step interpretation of 10-day electronic temperature monitoring devices for international vaccine shipments

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

IMR IX176 Portable Gas Detector User Manual

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

2014, TempSen Electronics Company

Specifications Minimum Typical Maximum Unit

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

Introduction. OM-THA2

CSP-204 CSP-208 CSP-104 CSP-108

WIRELESS 868 MHz TEMPERATURE STATION Instruction Manual

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

GasAlertMicroClip X3 Specifications

DataSheet. Thermocouple Logger

WHO PQS-Code E006/016. Q-tag CLm doc USB Multi- Limit Temperature Indicator

EL-USB-1-LCD Temperature Data Logger with LCD

Fridge-tag 2 L. with external sensor OPERATION MANUAL

ECOLOG TN2, TN3-P, TN4, TN4-L, TP2, TP4-L,TH1, TH2

OPERATING INSTRUCTIONS. G214 Software - Version 4

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

SCHMIDT LED Measured Value Display MD Instructions for Use

ELMTEC. Kattreppeln Königslutter / /

2. Safety instructions

EasyLog Data Logger Series

FEATURES AND SPECIFICATIONS

Fridge-tag 2 L OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Danfoss gas detection units

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

OPERATION MANUAL. ComfortSense 3000 Series Model No. L3011C Non-Programmable Thermostat. Table of Contents. L3011C Thermostat

Ambient Weather WS-28 Indoor/Outdoor Thermometer with Daily Min/Max Display User Manual

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

USER MANUAL USB Multi-Function Datalogger Model RHT35

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

Danfoss gas detection unit Type GD Heavy Duty

HIn3550 Magnetic Field Monitor User's Manual

DataSheet. Thermocouple Logger

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

Dual Probe Vaccine Temperature Data Logger w/ Software-Less Reporting

Fixed Life Single Gas Monitor

MOONPHASE WALL CLOCK Instruction Manual

TV2 Clean Room Monitor

Dual Point General Purpose Heat Trace Control TRACON MODEL GPT 230 Installation and Operation Manual

QUICK USER GUIDE. Alarm Control Panel

EL-USB-TC Thermocouple Data Logger with USB Interface

High Temperature InfraRed Thermometer with Laser Pointer

Ambient Weather WS-26 Indoor Thermo-Hygrometer with Daily Min/Max Display User Manual

HOBO U14 Data Logger User Manual

Tachometer/Hourmeter/Trip. Installation and Operation Manual

EXPERT TRI-STAR. Temperature controller. User s Manual

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-34 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Wireless Keypad GKP-S8M

DOCUMENTATION IPS640

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

EasyLog Data Logger Series

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

Section 9 System Operation

DOCUMENTATION IPS640

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

InTemp CX Temperature Logger (CX40x) Manual

Professional Wireless Rain Guage with 4" LCD

Atomic Alarm Clock Instruction Manual

64 Max IR Thermometer

User's Guide. Pinless Moisture Meter. Model MO257

OPERATING MANUAL. EchoTherm PROGRAMMABLE DIGITAL CHILLING INCUBATOR MODELS IN35, IN45 and IN55-12VDC. DOCUMENT NUMBER IN35-03 Revised 15 May 2015

Section 8 System Operation

WIRELESS COLOR FORECAST STATION

RSMFM-2R MULTIFUNCTIONAL

JA-63 Profi User manual

LONG-RANGE WIRELESS WEATHER STATION WITH IN-OUT THERMO-HYGROMETER AND RF CLOCK

No. Icon Name Function

SENSIT HXG-2d. SENSIT TECHNOLOGIES 851 Transport Drive Valparaiso, IN Phone: (219) Fax: (219)

E1000 Portable gas detector

aura-t TP536/EU ventilation systems

Transcription:

TICT - is0 Tag Freeze Indicator with display DOCUMENT REVISION 1.0, 4 March 2014 Copyright 2014, LogTag Recorders Limited

Contents Contents... 2 Document revision history... 2 Description... 3 Alerts... 3 Stored Statistics... 3 Display Overview... 4 Operation... 5 TICT is0 Tag Factory Pre-sets... 8 Product Specifications... 8 Document revision history Ver Date Author Details 0.1 8/8/13 MJ Initial 0.2 21/10/13 MJ Added Start Delay and Stop with Button. 0.3 23/10/13 SL Minor changes to improve readability, added picture 0.4 18/11/2013 SL Spec change for battery life, start delay, added TICT into product name 0.5 29/11/2013 SL Amended specs for 2 day only log buffer 1.0 4/03/2014 SL Release version Copyright 2014, LogTag Recorders Limited page 2 of 9

Description The TICT is0 Tag is a single-use, low cost electronic freeze indicator for monitoring temperature as well as recording statistics during the transportation and storage of chilled products, such as vaccines, food or specialty chemical products. The product is made from durable polycarbonate plastic and features an LCD display and a START/MARK button. The LogTag TICT is0 Tag can monitor and record statistics against one lower and one additional upper, factory pre-set temperature limit for up to 3 years, showing OK if environmental conditions remain within. If, however, temperatures exceed either the high temperature alarm limit or go below the low temperature alarm limit, the LCD shows a REJECT symbol, indicating the goods require further checking. In this case the indicator stops and cannot be reset, so an irreversible record is generated. An inspection mark can be recorded once each day to show the indicator has been checked. An interface cradle is available so trip statistics can be downloaded and saved for analysis in the freely available companion software LogTag Analyzer, including trip duration, minimum and maximum temperatures, inspection marks and exposure to levels outside the alarm limits. Up to three days of real time logged temperature data before and after the alarm trigger are available for further analysis [1]. Alerts Once the TICT is0 Tag is started, the indicator provides a visual status on the display, indicating OK () or Reject () throughout transport and storage. The indicator stops once any of the two alarms are triggered. Detailed information regarding temperature and time exposure during transportation and storage is made available via download in LogTag Analyzer. The two alarm limits are factory pre-set. Custom configurations can be ordered, allowing clients to select different alarm limit values (one upper and one lower) and alert event options such as instant or delayed reject alerts. Note the lower alarm cannot be disabled. Stored Statistics Statistics are collected and stored on a daily basis and can be downloaded using LogTag Analyzer. Run time for the trip (days, hours, minutes). Each day represents a period of 24 hours from 0:00:00 to 23:59:59. Day 1 begins when the Indicator starts monitoring. A new day starts when the internal clock advances from 23:59:59 to 0:00:00. Maximum temperature reached for each day the indicator was running. Minimum temperature reached for each day the indicator was running. The total accumulative time above/below for each of the two alarms on each day the indicator was running. Up to three days of logged readings (at the sample interval) are stored each before and after the Alarm has triggered. [1] Copyright 2014, LogTag Recorders Limited page 3 of 9

Display Overview Battery Low Operating State Alarm Event Types Alert Icons OK or Reject Display item Description Alert Indicators OK icon (). No alarms events have been generated; load has not been subjected to temperatures outside specified limits. Reject alert icon (). Alarm event has been generated, as temperatures have been outside specified temperature limits; load needs to be checked. Alarm Event Types (High Temperature) (Low Temperature) Each of the alarm event types are factory pre-set. If an alarm event is enabled and the temperatures monitored generate an alarm, the alert will change from OK to Reject and the alarm type will be displayed. When an Alarm has trigged the Reject icon will be displayed and the indicator will continue to run collecting statistics for 1 more day. Battery Condition Displayed when the battery test reports low, the unit will stop monitoring. Operation Waiting to be started:- Press and hold the START button will quickly flash the RUN icon (no other segments will be displayed). Releasing the button once the RUN icon stops flashing will start the indicator. Running:- The Indicator is running and temperature readings are taken. The display shows the alert indicators (OK or Reject ) and the statistical information is updated every sampling interval and stored every 24 hours. The RUN icon will briefly flash every 2 seconds (heart beat) while running. Stopped:- The indicator has been stopped; stored statistics can now be downloaded. Indicator stopped due to low battery ( & ). Indicator stopped due to a Lower Alarm trigger (). Copyright 2014, LogTag Recorders Limited page 4 of 9

Operation 1. Starting the Indicator The TICT is0 Tag Indicator is shipped in a state of low energy consumption (hibernation) to maximise battery life. Pressing the START/MARK button will wake up the Indicator. It will either briefly display the RUN symbol, if the battery is OK, or the Battery Low symbol for 30 seconds, if the battery is low. If the button is not pressed again during that time, the display will turn off and the Indicator will re-enter hibernation. An Indicator with a low battery cannot be started. To start the Indicator, press and hold the START/MARK button for 4 seconds RUN will flash. When RUN is permanently lit, release the button within 2 seconds. The Indicator will start taking temperatures immediately, unless a Start Delay is configured. The display will briefly turn off and on. 2. Start Delay The indicator can be configured so it does not start taking temperatures immediately, but only after a start delay time has passed. This delay allows the indicator to acclimatise to the temperature of the load, so it does not trigger an Alert too early. This is particularly important if a High Alarm has been configured The display will show alternating and symbols during this Start Delay period. The speed at which the symbols change is dependent on how much time is left until the indicator starts: More than 5 minutes left to indicator start - slow change Less than 5 minutes, but more than 1 minute to indicator start fast change Less than 1 minute left very fast change If the selected factory pre-set profile does not have a start delay enabled, the Indicator will start taking temperatures immediately. Copyright 2014, LogTag Recorders Limited page 5 of 9

3. Indicator running As soon as the Indicator starts, temperature readings are taken according to the sample interval defined in the factory pre-set profile. As long as the temperature readings stay within the limits defined by the two pre-set alarm events, the OK Alert () is displayed. The RUN symbol will flash approx. every 4 seconds. If an alarm event is generated, the Reject Symbol () is displayed. Depending on the factory pre-set profile, a lower only, or lower and upper alarm event types are enabled. Upper alarm event was generated Lower alarm event was generated Upper or lower alarm events are generated when recorded temperatures exceed the limit for a specified number of readings. Alarm events can be generated for example by a single temperature above (below) the limit, or by a number of sequential or accumulated readings above (below) the temperature limit. The alarm event types are independent of each other and are defined in the factory pre-set profile. 4. Placing a MARK in the Indicator statistics table The TICT is0 Tag can store a MARK in the statistic table for each day; this can be used to indicate the start of another trip or that a visual check of the indicator has been conducted. It will be displayed in LogTag Analyzer software once downloaded. Although only one mark per day is possible in the statistics table, each real time reading can be marked individually, once the indicator has registered an alarm. To place a MARK in the Indicator statistics table, press and hold the START/MARK button for 2 seconds and will flash together. When and are permanently on, release the button within 2 seconds. A MARK will now be placed into the statistics table. Copyright 2014, LogTag Recorders Limited page 6 of 9

The MARK will not be placed if you continue to hold the button after and are permanently on, until both arrows turn off. This is useful if you have started to press the button, but do not want to proceed with placing the MARK. In either case the display will revert to showing the RUN symbol. NOTE: The RUN may flash if STOP button is enabled, releasing the button while RUN is flashing will place a MARK into the statistic table. 5. Stopping the Indicator The Indicator will automatically stop: after one of the pre-defined alarm events has triggered an alarm or a period of three years has elapsed 30 days before the end of the 3 year period the low battery symbol will light, signalling that the Indicator requires replacing. 30 days after a battery test has recorded low The battery voltage is measured every 2 hours. The low battery symbol will light once the battery test reads a low battery, and the indicator will stop recording after 30 days, signalling that the Indicator requires replacing when the summary statistics are downloaded with LogTag Analyzer. After that, no additional readings will be taken or processed, and it is not possible to start the indicator again. The Indicator can also be configured so it can be manually stopped via the Button:- If this feature is enabled, stop the Indicator by pressing and holding the START/MARK button for 4 seconds: and will flash together for 2 seconds followed by RUN will flash for another 2 seconds. Release the button once RUN stops flashing. The Indicator will now stop and no further readings will be taken. Copyright 2014, LogTag Recorders Limited page 7 of 9

TICT is0 Tag Factory Pre-sets TICT is0 Tag Indicators cannot be client configured, but instead are purchased with one of a number of different factory configuration profiles pre-installed. If a default configuration does not suit, customers can compile their own profile by specifying the parameters in the table below when ordering. Please note that minimum order quantities apply for TICT is0 Tag units with profiles not stocked by. The default configuration profile is called Profile 0002 ; each custom configuration is assigned a different profile number which can be used for ordering. Description Profile 0002 (default) Range / Option Requirement Maximum Days (Maximum number of days to monitor) 1096 (3 years) 30-1096 days Start Delay 0 minutes 0 to 255 minutes Sampling interval 5 minutes 5 to 15 minutes* Allow stop via Stop button Disabled Enabled or disabled (High Temperature) Monitor this alarm Disabled Enabled or disabled Temperature limit value N/A -5 C to 60 C (-13 F to 140 F) Alarm activation N/A instant, accumulated or consecutive ** Activation delay time *** N/A 5 minutes to 45 days Monitor this alarm enabled enabled enabled (Low Temperature) Temperature limit value -0.5 C -5 C to 60 C (31.1 F to 140 F) Alarm activation Consecutive instant, accumulated or consecutive ** Activation delay time *** 1 hour 5 minutes to 12 hours * Preferred intervals are 5, 6, 10, 12 and 15 minutes ** Instant = one temperature reading is above/below limit; consecutive = temperature readings are above/below limit for the time defined in the activation delay time without interruption (single event); accumulative = temperature readings above/below limit for a total of time defined in the Activation delay time, but may not necessarily be sequential. *** Delay times for alarm activations must be in multiples of the sampling interval. Copyright 2014, LogTag Recorders Limited page 8 of 9

Product Specifications Part Code Operating Temperature Range Ambient humidity range during transport and use Resolution TICT is0 Tag -xxxx (xxxx = factory pre-set profile number) -25.0 C to +60.0 C (-13.0 F to +140.0 F) 0% to 95%RH 0.1 C or better in range of -25 C to +60 C (temperature shown after download) Accuracy Capacity Memory type ±0.5 C (±1.5 F) or better for -10 C to +25 C (+14 F to +77 F). ±1.0 C (±2.0 F) or better for range of -25 C to -10 C (-13 F to +14 F). ±1.0 C (±2.0 F) or better for range of +25 C to +60 C (+77 F to +140 F). Minimum & Maximum temperature for each day up to 3 years, the total accumulative time in excursion for each day plus one MARK button press per day. 540 real time temperature readings [1]. Please note the TICT is0 Tag does not store each individual temperature reading taken over the whole trip. Non volatile. Sampling Interval Factory pre-set between 5 and 15 minutes; 5 minute interval for profile 0002 Recordings Start delay Sensor Sensor Reaction time Vibration Shock Environmental Resistance to Electrical Storms Power source Up to 1096 day statistics, min/max temperature/time and accumulated excursion duration for each alarm for each day. One mark entry per day. Up to 540 real time readings are stored on an alarm activation [1]. 0-255 minutes (value of zero disables the start delay). Precision electronic thermistor T90 less than 7 minutes by method detailed in EN12830:1999 Withstands vibration specification as detailed in EN12830:1999 Withstands shock specification as detailed in EN12830:1999 Withstand 5 drops 1m to smooth concrete floor without loss of function or calibration. IEC 60529: IP64 Designed to resist the effects of intense electrical storms. Internal 3V Lithium Li-Mg non replaceable Battery life 3 years (includes storage, operating time and minimum accessibility period after stop ). Size Weight 19g. Case Material Warranty Calibration 71.5mm(W) x 33.0mm(H) x 8.6mm(T) Polycarbonate One year replaceable warranty against defects in materials and workmanship from the date of purchase. Excludes misuse or abuse of the product or as a result of unauthorized alteration or repairs. Certificate of Traceability and Calibration to ISO/IEC17025 available on request. EMC compliance Alarm events EC EMC directives (EN 61000-6-1:2005 & EN 61000-6-3:2006) Including electrostatic discharge as prescribed in EN 61000-4-2. Complies with FCC Part 15 Subparts A and B. Two factory pre-set alarm events, one over temperature (optional) and one under temperature (always enabled). Each alarm event can be instant reject or accumulative/consecutive reject. Alert indication OK = Temperature has remained within the alarm limits. Reject = Alarm event has been generated [1] up to 270 readings before and up to 270 readings after an alarm event are stored at the sample interval. For 270 readings to be stored before the alarm was triggered, the is0 Tag has to be running at least for the time covered by [270 x sample interval] before the alarm was triggered. For 270 readings to be stored after alarm activation, the is0 Tag must not be stopped by downloading or using the START/MARK button. Copyright 2014, LogTag Recorders Limited page 9 of 9