Product Dimensions Page 1 of 7. DA Downdraft Ventilation Hood

Similar documents
36 Downdraft Hood Proud Mounting

Operating and Installation Instructions

ducted / recirculating separately 2.1 WS / 11.8 HS 3-stage Rear Yes (600 CFM options sold separately) 29 3/8" x 31" x 2 3/4" 6" or 8"

UCVM30FS 30-INCH DOWNDRAFT VENTILATION MASTERPIECE SERIES

UCVM36RS 36-INCH DOWNDRAFT VENTILATION MASTERPIECE SERIES. GENERAL PROPERTIES Operating Mode Convertible: Ducted / Recirculating

VIPR Professional Downdraft w/remote

Operating and Installation Instructions Downdraft

Over-the-Range Microwave professional series

Operating instructions for the DA 8-2 Extractor

Product and Cut-out Dimensions Page 1 of 5

Installation Instructions DAR 1150, DAR 1220 DAR 1230, DAR 1250

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

MODULES. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

Installation Instructions

Downdraft Ventilation

Over-the-Range Microwave

Operating and Installation Instructions

Installation Instructions Remote Blowers

ERV3015, ERV3615, ERV36-ER, ERV48, ERV48-ER, PRV30, PRV36, PRV48

Installation Instructions

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Operating and Installation Instructions Ventilation Hood

CATTURA TM DOWNDRAFT MODELS D49M30SB, D49M36SB, D49M48SB

Viking Installation Guide

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

Installation Instructions

Installation Instructions

Installation Instructions

RANGETOPS. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

Operating and Installation Instructions

Operating and Installation Instructions

Operating and Installation Instructions

TRUE INDUCTION GAS COMBO COOKTOP MANUAL

Who says you have to sacrifice the fun of grilling

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

SPECIFICATIONS - INDUCTION/RADIANT COOKTOP Description 30 W. VCCU 36 W. VCCU. SPECIFICATIONS - ALL INDUCTION COOKTOP Description 30 W. VICU 36 W.

READ AND SAVE THESE INSTRUCTIONS

Operating and Installation Instructions Range Wall / Insert Hood

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

Cooktop Chimney Ventilation Hoods

12,000 BTU Sealed Burner. For responsive cooking when using large pots and pans. Even Baking Technology

To round out your options for the ideal kitchen, you

Operating and Installation Instructions Ventilation System

Express-Select Controls Easily go from warm to boil.

NEW UNDER-CABINET HOOD INSERT DESIGN GUIDE

ERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down

Built-In Cooktops FGGC3665K S/W/B. 36" Gas. Signature Features. More Easy-To-Use Features. Product Dimensions

Operating and Installation Instructions Ventilation hood

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

WM-4510HZD Installation Instructions

Combination. IMPORTANT: Read and save. these instructions. Par-t No W / Rev. A

gas cooktops EW30GC55P S / B

Installation Instructions

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

Glass Canopy Wall-Mount Hood

Installation Instructions

INSTALLATION INSTRUCTIONS

Amana. Product Guide

Express-Select Controls Easily go from warm to boil.

Built-In Cooktops FGEC3067M S/B. 30" Electric. Signature Features. More Easy-To-Use Features. Product Dimensions

The D1000. Typical Specifications: activate the mechanical fire suppression system. (pressurized potassium citrate / potassium acetate mix)

Continuous Grates. Continuous grates make it easy to move heavy pots and pans between burners without lifting. Sealed Gas Burners

Fits-More Cooktop. The Fits-More cooktop features five burners so you can cook more at once. Sealed Gas Burners

INSTALLATION INSTRUCTIONS

Installation Instructions

12,000 BTU Sealed Burner. For responsive cooking when using large pots and pans. Black Matte Finish with Cast Iron Grates

Built-In Cooktops FGEC3645K S/W/B. 36" Electric. Signature Features. More Easy-To-Use Features. Product Dimensions. Hot Surface Indicators

PowerPlus FullRange Burner Go from a 500-BTU simmer to a 17,000-BTU boil quickly.

PowerPlus FullRange Burner Go from a 500-BTU simmer to a 17,000-BTU boil quickly.

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Induction cooking has been used in Europe for decades

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

Falcon Undercupboard Rangehoods Installation Instructions & User Guide

Installation Instructions

NEW CEILING-MOUNTED HOOD DESIGN GUIDE

INSTALLATION INSTRUCTIONS

Operating and Installation Instructions Ventilation Hood

Gas and Electric Convection Ovens

The D1000. Typical Specifications: Standard Options*: Model: D1036-F Spec & Submittal Version 2.2 D1000-F_ D1000-F_-NFPA101

University of Missouri St. Louis UMSL Project #S7628 Campus Police Building Building Modifications & Renovations R&B Project # Building Upgrades

INSTALLATION INSTRUCTION & OWNER S GUIDE

Signature Features. One-Touch Options. Multi-Stage Cooking. Sensor Cooking Options. Ready-Select Controls. More Easy-To-Use Features

DESIGNER WALL CANOPY

From a temperature of 140 F (60 C) to boil, you can

Cooking. Models Shown: ARS2464BW, ACO1860AW And ACF3355AW 17

Model Serial Number and Product Rating Guide

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. RXID-AW90A Whole House Dehumidifier

For more information on the MARR program or any questions on the product list, please refer to or contact MARR at

Even Baking Technology. Our latest technology ensures even baking every time. Hi /Lo Broil Option

READ AND SAVE THESE INSTRUCTIONS Page 1

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

READ AND SAVE THESE INSTRUCTIONS

MIST MAX MODEL MM800. Important: Installation and Operation Manual

Operating and Installation Instructions Ventilation System

Transcription:

Product Dimensions Page 1 of 7 Location Codes 1 DAG 500 Internal blower The blower box can be mounted in such a way that the vent collar is aligned to the left, the right, downwards or towards the rear, as desired. 2 Connection plate when using the DAG 1000 external blower. The blower or the connection plate can also be mounted in the same position on the rear of the Appliance. X = Distance to the rear of the cabinet or wall. Must be a minimum of ½ (13 mm). Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with external blower DAG 500 Internal Blower - 6 Ø (150 mm) DAG 1000 External Blower- 10 Ø (254 mm) Item 28648050USA DA 6480 Shipping weight 44 lbs (20 kg) Shipping dimensions 31 5/16 (795 mm) L x 8 1/4 (210 mm) W x 33 1/16 (840 mm) H Item 28649050USA DA 6490 Shipping weight 50.7 lbs (23 kg) Shipping dimensions 37 (940 mm) L x 8 1/4 (210 mm) W x 33 1/16 (840 mm) H The hood requires a 120 VAC, 60 Hz, 15 A hard wire connection to the terminal. All electrical work should be performed by a qualified electrician.

Cut-out Dimensions Page 2 of 7 Location Codes A Cooktop Overhang B Cooktop Minimum Width DA6480: 28 (711 mm) DA6490: 34 (864 mm) C Vented rear D Feed the power cord and control cable when using an external blower downwards or to the rear. Exhaust duct connection diameters DA 6480, DA 6490 with internal blower DA 6480, DA 6490 with external blower DAG 500 Internal Blower - 6 Ø (150 mm) DAG 1000 External Blower- 10 Ø (254 mm) Notes: Not to be used with Miele CombiSet units The specified dimensions minimum cut-out dimensions must be observed. If an oven is installed in front of the ventilation system, ensure that all installation dimensions and guidelines regarding ventilations systems. Be aware of kitchen cabinets, back splashes and/or racks in the area of the ventilation system and the cooktop. Ensure that the area where the vent rises is free of obstacles. Make sure that any required minimum distance between the front edge of the countertop and the front edge of the cooktop is maintained.

Product and Cut-out Dimensions Page 3 of 7 Exhaust air ducting using the DAG 500 internal blower, installed on the front of the appliance [vent duct 6 ø (150 mm)] A to the left or right B downwards C to the rear If the blower is being installed at the rear of the appliance, a cut-out must be made in the rear of the cabinet or wall where it can be mounted and appropriate clearances must be maintained behind the cabinet.

Product and Cut-out Dimensions Page 4 of 7 DAG 500 Internal Blower Shown with interior mounted DAG 500 vent motor DAG 500 mounted in front of the exhaust system. DAG 500 Internal Blower exhaust diameter- 6 Ø (150 mm) Maximum load with interior-mounted DAG 500 vent motor 420 W DAG 500 mounted behind the exhaust system. Note that the blower must be accessible to install the venting ductwork Item 28996319USA DAG 500 Shipping weight 23 lbs (10.5 kg) Shipping dimensions 24 (610 mm) L x 18 5/16 (465 mm) W x 18 1/8 (460 mm) H

Product and Cut-out Dimensions Page 5 of 7 DAG 1000 External Blower Installation using the DAG 1000 external blower connection plate Exhaust air ducting to the front. Exhaust air ducting to the rear. Note that the back must be accessible for installation of the venting ductwork If using the external blower, install a connection cable between the ventilation system and the external blower. DAG 1000 External Blower exhaust diameter- 10 Ø (254 mm) Maximum Load with exterior-mounted DAG 1000 vent motor.210 W

Product Dimensions Page 6 of 7 DAG 1000 External Blower ¾ Conduit Size 10 ø DAG 1000 External Blower exhaust diameter- 10 Ø (254 mm) Item 28996291USA DAG 1000 Shipping weight 55 lbs (25 kg) Shipping dimensions 36 1/4 (920 mm) L x 13 1/4 (336 mm) W x 30 (762 mm) H

Product and Cut-out Dimensions Page 7 of 7 Downdraft Recirculation Kit DUU 2900 2 1 3 Details Item 09162160 Cabinet cut-out 15 7/16 x 8 13/16 (392 mm x 224 mm) To be vented out the sides or base of cabinet. 5 7/8 Vent port can be mounted in 3 positions Discharge Grill exhaust is 180 Two - Item number 09162160 - DKF 18-1 Charcoal filters included