"HC" AIRFLO. In-duct firing line burner

Similar documents
V-Line. Nozzle-mix line burner

Series LV AIRFLO. In-duct firing line burner

DELTA-TE III. Nozzle-mix line burner

"NP" & "RG" AIRFLO. In-duct firing line burner

APX. Nozzle-mix line burner

Specifications of V-Line burners

INDITHERM. Low temperature gas burners

INDITHERM. Low temperature gas burners

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Specifications of MULTIFIRE burners

Lanemark Midco HMA2A Series Air Heating Burner and DB Duct Burner System Application Manual

RS /E-EV C01 SERIES

RIELLO 40 GS/M SERIES

Product Information. Model: HG, HL, HLG Burner Sizes: 10, 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

INDUSTRIAL MICRODIFFUSION OIL BURNERS

FLAT FLAME AND EXCESS AIR BURNERS

TUBE-O-THERM Low Temperature Gas Burners

We offer ceramic radiant heaters and infra-red radiant tubes.

RS /E-EV C01 SERIES

LOW NOx MODULATING GAS BURNERS

EXCESS AIR BURNERS XNM SERIES FEATURES APPLICATIONS DESCRIPTION. Bulletin E3502 rev05 31/01/00

1 - High-velocity gas burners

Trends for Radiant Tube Heated Strip Lines

Ecomax. Direct-Fired Self-Recuperative Metallic Gas Burner. Features

Bert Uneken, Field Engineering Manager Ruben Kranenburg, Technical Support

Madhu Honap HONEYWELL THERMAL SOLUTIONS INTRODUCTION

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

Eclipse AirHeat Burner

Eclipse AirHeat Burners

HAUCK STARJET BURNER SJ075 SJ980

Boiler Basics. Design and operation

Zeeco, Inc. Doc. No Tulsa, Ok Cover Page GLSF-14 Free-Jet and RWSF-4 Radiant Wall Burners. Range Fuels Soperton Plant, LLC

High Performance Diesel Fueled Cabin Heater. Abstract

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

Steam Fundamentals. (in heating & processing applications)

OPERATING AND MAINTENANCE MANUAL

PBG PACKAGED GAS BURNER

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

DESIGN PHILOSOPHY. Indirect bath heaters have a wide variety of successful applications in the oil and gas

Efficiency and Design Improvements in Multiple Hearth & Fluid Bed Incinerators

NMC Nozzle Mix Gas/Oil Combination Burners

Energy recovery from exhaust gases using Heat Pipe technology

Installation Instructions

Module 5: Combustion Technology. Lecture 38: Combustion Burners

BURNERS/ FLARES. VAREC BIOGAS 244W Series WASTE GAS BURNER & IGNITION SYSTEM

FGR. Installation, Operation and Startup Instruction Manual FOR FLUE GAS RECIRCULATION SYSTEM. FGR-8 through FGR-22 (25 HP to 1000 HP)

Eclipse AirHeat Burners AH Series version 2.00 (Patent Pending)

NMG NOZZLE MIX GAS BURNERS

Document code: 1 (10) Issuing date: Status:

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

The World s First Flameless Crude Heater

Products & Services. DISTRIBUTOR & FOREHEARTH SYSTEMS

TECHNICAL DATA MOBILE WASTE INCINERATOR

DESIGNING A COMBUSTION AIR/GAS PRE MIX SYSTEM FOR RED RAY INFRARED PROCESS BURNERS

Eclipse ER Indirect Air Heater

Self-recuperative burner for gas

25 Years IBS GmbH. Innovative and taylormade burner systems

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

Cata-Dyne LH Line Heater & Micro Line Heater

MULTIPLEX SELF RECUPERATIVE gas burner

STARJET BURNER SJ075 SJ980

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Design and Application Details

THE WORLD S FIRST FLAMELESS CRUDE HEATER

Yarway Narvik Steam Desuperheater Series 4300 TempLow

THE SIGNIFICANCE OF RELIABLE PRESSURE CONTROL IN OILFIELD BURNER SYSTEMS

FUEL-FIRED VERTICAL TUBELESS BOILERS

ECLIPSE INFORMATION GUIDE

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

Kolmetz Handbook Of Process Equipment Design BURNER MANAGEMENT SYSTEMS (ENGINEERING DESIGN GUIDELINE)

FLUIDIZED BED BOILERS

Mist eliminators for Flue Gas Desulphurization

Since 1983 Nuova COTERM has developed a wide range of water heaters.

Gas-Fired Indoor and Outdoor Duct Furnaces

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

Gas Safety. Syllabus. For 120kW. Class B gas fitter. Certificate of qualification examination

SULPHUR RECOVERY UNIT

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

PYRO-LINE BURNERS 126LX 6LE 12LS DESCRIPTION MODEL: 3201

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

GAS ABSORPTION HEAT PUMP

Seasonal Efficiency Longevity Part-Load Efficiency Condensing Operation Fast ROI MODULEX BOILERS MLX-1060 MLX-909 MLX-757

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

Design Guide 111 9/25/2008. Eclipse Winnox Burners WX Series Version 1

Flue Dilution Fans. Specialists in Air Movement Technology. IMPROVED GBDF MK5 Now includes a Pressure Safety Switch and easier Electrical Connections

BALANCED FLOW METER PLATE APPLICATIONS

When you complete this module you will be able to: Describe various watertube boiler designs, including large generating units.

INFRA-RED BURNERS BR-70 SERIES FEATURES APPLICATIONS. Bulletin E3005 rev03 31/01/00

Solutions to Pollution

INSTRUCTION MANUAL FOR OIL BURNER MODELS

Waste/Multi Oil Boilers from Flexiheat

Energy saving and better heat control.

BG2000S PRE-MIX GAS BURNER

Efficient Steam System Design

MEGASTAR TM BURNER MS-25 MS-150

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

Transcription:

"HC" AIRFLO In-duct firing line burner -.- High heat release up to.5 MW per unit of burner length (05 mm) Clean combustion with low CO and NO x emission levels Minimal process air pressure drops locally across the burner as low as 0.5 mbar Operates in fresh air, preheated air (up to 600 C) or low oxygen turbine exhaust gases Fires on natural gas, H and all mixtures. Special versions for propane, butane, LPG and refinery gases are available 00 % stainless steel construction for long life performance No external combustion air required Plug mounted in duct wall insures low installation costs Burner capacity independent of back pressure variations and uniform heat distribution along burner length due to high gas pressure

-.- Product description MAXON Series HC AIRFLO burners consist of a stainless steel burner manifold which not only serves as a burner frame but also transports the fuel gas to the gas nozzles and supports the diverging Hastelloy mixing plates. 5 7 6 ) Gas inlet ) Manifold ) Mixing plate ) Plain end plate 5) Pilot end plate 6) Gas nozzle 7) Deflector plate 8) Pilot gas ports L: Burner length L 8 Principle of operation The burner is mounted directly into the process air stream being heated. Thanks to the unique design of the V-shaped mixing plates, the high velocity injected fuel and the process air are intensively mixed. The required oxygen for combustion is progressively drawn from the process air stream. The special designed aeration patterns in the mixing plates insure progressive mixing, superior cross ignition, reliable flame retention, clean combustion over the full capacity range and increased flammability on low O applications. A small part of the process air stream to be heated is forced through the burner mixing plate holes and is used as primary combustion air. This primary combustion air is mixed with the gas flow injected through the pilot gas ports. The flames retain on the inside of the mixing plates and serve to ignite the high velocity fuel jets injected through the gas nozzles. These jets create large recirculating areas in the flame. This thorough mixing guarantees high capacity clean combustion, avoiding hot spots in the flame and thus reducing thermal NO x formation. This unique principle of operation allows HC AIRFLO burners to operate with both low NO x and low CO, over the complete turndown.

-.- Complete burner assembly ) Mounting plug ) LVDT/HC pilot burner (see section -. for detailed information) ) Gas inlet ) Mixing plates 5) Mounting support 6) Test connection (upstream process air pressure) 7) Test connection on LVDT/HC pilot burner (downstream process air pressure) 8) UV scanner connection 9) Process air flow direction 6 8 7 9 5 All HC AIRFLO burners include a stainless steel mounting plug which not only supports the burner but also carries the pilot burners and accessories such as ignition transformers, UV scanners etc. A stainless steel mounting support to carry the weight of the burner is standard included. Thus the burner comes as a complete package, allowing easy installation on site.

-.- Available "HC"-AIRFLO sizes "HC" AIRFLO burners are always supplied as slide-in-units with a mounting plug which can be easily flanged onto the duct. They are custom-built to fit into your duct, with a flame-spread (= burner length) starting from ft going up to ft in steps of 0.5 ft. ( ft = 05 mm) Three types are available, depending on burner length and duct width: "HC" AIRFLO Type Burner length Max. duct width (mm) [] Type S ft to 7.5 ft 000 Type M ft to 0 ft 6000 [] [] Type L 8 ft to ft 6000 [] [] [] valid for upstream temperatures up to 600 C. [] can be increased to 8000 mm when inlet temperature does not exceed 550 C. [] can be increased to 8000 mm with max inlet temperatures up to 650 C when higher grade materials are used for burner supports. Contact MAXON for larger duct widths, and/or burner lengths. Typical burner data The data given in this table apply for nominal burner capacities of 500 kw per foot. In some specific applications the actual maximum capacities can be considerably higher (up to 500 kw per foot). Refer to specifications for further details. Typical burner data Fuel : natural gas with 0.9 kwh/nm³ HHV) - sg = 0.6 [] Stated pressures are indicative. Actual pressures are a function of air humidity, altitude, type of fuel and gas quality Application Boiler firing TEG-Firing [] AUX-Firing [] High temp. (T in >00 C) Process Firing Low temp. (T in < 00 C) Nominal capacity per foot [][8] kw HHV 500 500 500 500 Min. capacity per foot [8] kw HHV 00 00 00 50 Max. upstream temperature [5] C 600 0 600 00 Max. downstream temperature C 950 750 [5] 950 950 Fuel pressure at nominal capacity [6] bar Flame length at 50 % capacity or up [7] m.5 5.5.5.5 5.5.5 [] sg (specific gravity) = relative density to air (density air =.9 kg/nm³ ). [] TEG = turbine exhaust gas [] AUX = auxilary firing [] Maximum capacity will depend on application boundary conditions such as acceptable flame length, required emissions, available oxygen, up/downstream temperatures, duct lay-out, process air differential pressure, ). Therefore, the actual maximum capacity might be lower than 500 kw per foot or could be up to and even above 500 kw per foot in specific applications. [5] Upstream temperatures up to 650 C are possible with higher grade materials (contact MAXON). Limitation on downstream temperature from 950 C down to 750 C is due to possible risk of higher NO x emissions when this limit is crossed. [6] The stated pressures are valid for burner sizes up to ft. For larger burners, the gas inlet pressures will be higher. Refer to specifications for detailed information. Stated pressures are measured at burner gas inlet tube. [7] Flame length is only given as a guideline. Actual flame length depends on a number of parameters such as process air oxygen level, process air pressure drop across burner. (contact MAXON for specific information). [8] ft = 05 mm.

-.-5 Applications MAXON Series "HC" AIRFLO burners are designed for fresh and recirculating process air heating applications. It is possible to operate the "HC" AIRFLO burner in a process air stream with vol% or less O content, provided adequate inlet temperatures are available. The burner design ensures that requirements of space, capacity and low pressure drops of any application are met. Typical applications Turbine exhaust gas (TEG) reheat applications, where low process air pressure drops, high capacities and high quality combustion are required. TEG/AUX installations where clean reheating of TEG is combined with high capacity fresh air firing operation. Start-up burners for fluidized bed combustion. Large incinerators. Processes where (recirculating) air has to be heated, with oxygen levels down to % if sufficiently preheated. High capacity fresh air heating. Application example MAXON "HC" AIRFLO burner installed in an upwards inclined duct: supplementary firing of turbine exhaust gases in a co-generation installation. ) HC-S 5.5 ft burner ) SMARTLINK fuel control valve ) Series 8000 pneumatic safety shut-off valves ) Control panel 5) Gas pipe-train 6) Cooling air skid 6 5

-.-6 Dimensions and weights "HC" AIRFLO type S ( ft 7.5 ft) D E L F W ) Mounting plug ) Gas inlet ) LVDT/HC pilot burner ) Scanner connection Rp A B [] Valid when duct has internal insulation (without cladding). In case of sheet metal wall, E and F should be at least 500 mm "HC" AIRFLO type M ( ft 0 ft) Dimensions in mm unless stated otherwise A B D E [] L F [] W weight (kg) 560 0 00(min) to 600(max) 00(min) burner length 00(min) 000(max) 65 + (5 x burner length in ft) W D E L F ) Mounting plug ) Gas inlet ) LVDT/HC pilot burner ) Scanner connection Rp A C B Dimensions in mm unless stated otherwise A B C D E [] L F [] W weight (kg) 560 666 706 00(min) to 600(max) 00(min) burner length 00(min) 8000 (max) 76 + (7 x burner length in ft) [] Valid when duct has internal insulation(without cladding). In case of sheet metal wall, E and F should be at least 500 mm

-.-7 "HC" AIRFLO type L (8 ft ft) W D E L F ) Mounting plug ) Gas inlet ) LVDT/HC pilot burner ) Scanner connection Rp A C B [] Valid when duct has internal insulation (without cladding). In case of sheet metal wall, E and F should be at least 500 mm Dimensions in mm unless stated otherwise A B C D [] E [] L F [] W weight (kg) 560 666 706 00 (min) to 600(max) 700-D (min) burner length 00 (min) 8000 (max) 05 + (7 x burner length in ft) Typical emissions (burners only) Thanks to the unique mixing plate design, the "HC" AIRFLO burner creates large recirculating flame patterns which combine high burner capacities with low emissions on both CO and NO x for the entire burner firing rate. Read Specifications of "HC" AIRFLO burners for correct and complete information on "HC" AIRFLO burners.