NIBA COOLING TOWERS. Niba is established in 1993 in Istanbul, Turkey.

Similar documents
Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

DESCRIPTION OF COOLING TOWERS SERIES TAT

What is Cooling S.Sen

Privately held company

FAN IMPELLERS & FAN CASINGS

SECTION COOLING TOWERS

Products and Services

COMPANY PRESENTATION

SECTION COOLING TOWERS

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

NEWIN Centrifual Fan Forced Draft Cooling Tower Product Introduction

Mr. GoodTower Service Center

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

DESCRIPTION WATER COOLING TOWER TAS/TASF (*) SERIES

kl-direkt WIND POWER Towers Wet paint overspray Large components Zinc spraying processes Power head Fabrication processes Special edition: Wind Power

Closed Circuit Cooling Towers

What is a Closed circuit Cooling Tower (CCT)?

DIVISION 15 MECHANICAL

EVAPORATIVE COOLING, a natural occurrence

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

CTI Sponsored Educational Program

E. Baffle Tray Column (or, Termed Shower Deck, No Holes, Caps, or Other Contact Devices)

QuadraFlow Cooling Tower

ICT Cooling Towers. Stainless Steel Basins and Fiberglass Casings Available. Advanced Features In Induced Draft, Counterflow Towers.

Cooling Towers. Energy-efficient solutions for open circuit, closed circuit and double-cell cooling towers.


COOLING TECHNOLOGY INSTITUTE

Cooling Tower Designs

life began in water...

/ Aquatower Fiberglass Cooling Tower /

ANSI RAB QMS. Parag Energy Efficient Axial Flow FRP Fans

Vibration Of Cooling Tower Fans. Barry T. Cease Cease Industrial Consulting Vibration Institute 2015

ABOUT US. Technical Drawings

A. Codes and Standards that are Standard at the University:

VLT 6000 HVAC Application Booklet

kl-direkt WIND POWER Towers Wet paint overspray Large components Zinc spraying processes Power head Fabrication processes

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

Lenntech. Tel Fax

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

PLATE HEAT EXCHANGERS

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

LEAD RECYCLING PLANT. Battery Machine Manufacturers: Since 1989

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

and SHUTTERS Made to Work. Built to Last.

POWER TOWER SERIES Fiberglass Construction 45 to 540 Tons

STAINLESS STEEL EVAPORATIVE CONDENSER

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

READ ONLY THE ALL-SEASON COMFORT OF TRANE TRANE PACKAGED GAS/ELECTRIC HEATING AND COOLING SYSTEMS

CLEAN AIR SYSTEMS DIVISION. An ISO 9001 Certified Company. Nan Technical Trading W.L.L P.O.Box Manama Kingdom of Bahrain

TRANE PACKAGED HEAT PUMPS THE ALL-SEASON COMFORT OF TRANE Exceptional heating and cooling all year long READ ONLY TRANE PACKAGED HEAT PUMPS

TEVHR. Heat Recovery Ventilator

SNOWCOOL SYSTEMS INDIA PVT LTD.

Evaporative Condensers

The equipment for storage and transportation of grain

Company History Locations Product range References

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

havanızın konforu için... TÜRKÇE ENGLISH DEUTSCH РУССКИЙ ELEKTROSTATİK FİLTRE ÜRÜN KATALOĞU alperen.com.tr

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

How about Savings in Time, Money, Energy and Longer Life?

Series 1500 Cooling Tower Specification


TOPAZ ADIABATIC COOLER

CONTACT US. For more information,

Chore-Time Fan Guide For Tunnel and Other Applications

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

JM Aerofoil Fans Bulletin JMA60-05

laboratory & sterilization technology

TEXTILE AIR ENGINEERING EASY INSTALLATION HIGH PERFORMANCE ENERGY EFFICIENCY

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

AIR DUCT ACCESSORIES

Bulletin 241B. Mark owned by the Cooling Technology Institute

Aquatower STEEL COOLING TOWER. engineering data and specifications

Exchangers. Air-cooled Heat. Exchangers

SECTION AIR DUCT ACCESSORIES

Jenroll EXPress Optimized evaporation capacity for integrated finishing lines

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Manufacturing & Production

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems.

Efficient, Long Lasting Evaporative Condensers

KIA Magnet Co. PLANT EQUIPMENT SUPPLIER & PRODUCER 1

TRANE PACKAGED DUAL FUEL HEATING & COOLING SYSTEMS THE ALL-SEASON COMFORT OF TRANE Enjoy the flexibility of two energy sources. Reliable.

Centeral Station Air Handling Unit

Fire-Resistant. Automatic Doors

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

AMERICAN COOLAIR CORPORATION. Greenhouse Ventilation Systems. Farm Products Division

SECTION DUCTWORK

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

Inside CIM this month. Metal Cutting: Robotic Milling. Tooling: Threading. Fabricating: Robotic Welding.

Residential & Commercial Water Booster Systems Frequency Controlled Water Booster Systems

IGH FX / IGH FX EC. Heat Recovery Ventilation Unit

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Cooler attics made possible by the sun

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

Can we use knowledge and experience from other sectors to prove Water mist s suitability for land applications? UK Water Mist Seminar 8th March 2016

Howden Netherlands Cooling Fans. Desmond de Haan Area Manager

Solutions for. HVAC/Refrigeration. Axial Fans and Clutches

Transcription:

1

NIBA COOLING TOWERS Niba is established in 1993 in Istanbul, Turkey. Niba is manufacturing package type water cooling towers in its own manufacturing plant; doing the marketing of water cooling towers and spare parts, sale and assembly. maintenance; engineering and contracting. Niba is giving services of maintenance, repair and control for working cooling towers; engineering and contracting. 2

NIBA COOLING TOWERS Advantages of Niba Cooling Towers Niba cooling towers are designed to realize optimum cooling. The tower, the main structure and water basin are made of GRP (Glass Reinforced Polyester). GRP is resistant against corrosion and has got a very long product life time. The internal and external surface of the tower is from Gel-Coat material which is resistant against all weather conditions and UV-rays. It is non-fading, non-rotting. Water cooling towers and parts made of GRP, are not painted. Their color is given by polyester based pigments at the time of manufacture. If required GRP can be painted later for aesthetic reasons. As the color is given by polyester based pigments, in theory any color can be produced upon customer request. 3

NIBA COOLING TOWERS Advantages of Niba Cooling Towers To manufacture the cooling towers in our own plant, give us the chance to keep allthe production process under control and to make necessary interventions. To realize our own manufacturing give us the possibility to use best material, best qualified labor, to pay attention to all details upon our experience in the sector, to supply solutions to our customers with high quality and performance with long product life in competitive economical conditions. Having as the motto The best advertisement is the product itself and the thoughts of our customers who are happy from our product and service, Niba had the results along the years and proved how it was right with such a view with hundreds of references in Turkey and foreign countries. 4

NIBA COOLING TOWERS Are Used in Cooling (chiller) units Textile mills White goods factories Treatment plants Refining & petro-chemical plants Food & Drink Factories Iron-steel plants MDF Plants Aluminum factories Plastic Factories Casting plants Pharmaceuticals industry Power plants Machinery industry Automotive industry Cement plants HVAC Applications Hotels Airports Hospitals Shopping malls and business centers 5

NIBA HAS TWO MAIN TYPES COOLING TOWERS MFK Model Towers HMP Model Towers MFK type water cooling towers for smaller capacity. HMP type water cooling towers for bigger capacity. 6

HMP TYPE COOLING TOWERS Designed for bigger capacities, the HMP model water cooling towers are made tomakethe optimum cooling. In HMP model towers, the fan is located at the top of the tower. HMP model towers are counter-flow and induced draft, the fan is axial 7

COMPARISON OF COUNTER FLOW & CROSS FLOW COOLING TOWERS 1 Counter Flow Maximum thermal efficiency. Counter flow towers need smaller area. Relatively high air static pressure losses. Typically creates lower tower pumping head (when film fill type is used). The probability of recirculation is lower. Minimum exposure of fill and water distribution system to sunlight reduces the potential for algae growth. Counter flow towers have basic and rigid shape with square or rectangular base area. Design allows more effective ice control in freezing climates. 2 Cross Flow Lower thermal efficiency. Cross flow towers need bigger area. Lower air static pressure losses. Pumping height is higher (commonly splash type filling is used in cross flow towers). The probability of recirculation is higher in cross flow, because louvers are located up to deck level. Water is distributed through open ducts; moreover sunlight comes into the tower through louvers causing serious biological formation. Cross flow towers have complicated construction with increasing width to the top. Louvers of cross flow towers may freeze easily during winter operation because of their wide surface. 8

THE DRIVE IS CONDUCTED IN DIRECT DRIVE IN HMP MODEL TOWERS Direct Drive Direct Motor Motor with GearBox 9

HMP DIRECT DRIVE In direct drive system, either a direct motor or a motor with a gear box is used. The motor is placed just on top of the fan. The gear box to be used is single level, helical geared, with motor and flange. 10

HMP TYPE COOLING TOWERS Up to 3200 mm of diameter, aluminum pultruded profile blades are used in HMP type cooling towers. If the noise level is critical for the application, special ultra silent fans are used. 11

HMP TYPE COOLING TOWERS Our HMP models can be manufactured together in two or more cells, to satisfy the need. 12

CERTIFIED COOLING TOWERS Niba is the first and the only certified water cooling tower manufacturer from Turkey. Niba s NB type water cooling towers are certified by CTI and Eurovent Certita Certification. 13

CERTIFIED COOLING TOWERS 14

CERTIFIED COOLING TOWERS 15

CERTIFIED COOLING TOWERS 16

HMP TYPE COOLING TOWERS If required, our HMP models can be assembled in one place and can be lifted to its operation place later. 17

MFK TYPE COOLING TOWERS Designed for smaller capacities, the MFK model water cooling towers are made to make the optimum cooling. In MFK model towers, the fan is located at the side of the tower for easy maintenance. MFK model towers are counter-flow and forced draft. 18

MFK TYPE COOLING TOWERS The fan blades are of PPG material. The fan cabin is made of electro galvanize plated sheet metal. Fan Cabin PPG Fan Blade 19

REFERENCES IRON & STEEL Andec Iron & Steel - Ecuador 6 x 2HMP (8x12) 29.250.000 kcal/h 20

IRON & STEEL Univers Acier Steelworks - Morocco 3 x 3HMP (18x18) 60.000.000 kcal/h 2 x 2RHMP (18x18) 24.000.000 kcal/h 2HMP (16x18) 12.000.000 kcal/h 21

IRON & STEEL Univers Acier Rolling Mills - Morocco 22

IRON & STEEL Zobu Şahin Steelworks Binap - Iran 4 x HMP (18x18) 40.500.000 kcal/h 2 x RHMP (16x16) 7.500.000 kcal/h HMP (16x18) 6.000.000 kcal/h HMP (12x14) 3.750.000 kcal/h 23

IRON & STEEL Zobu Şahin Steelworks Binap - Iran 24

IRON & STEEL Rajhi Steel - Riyad Saudi Arabia 25

IRON & STEEL Ekinciler Iron & Steel Iskenderun, Turkey 3RHMP (16x16) 26

IRON & STEEL Ferrexpo Cast Factory Dnepropetrovsk, Ukraine 4HMP (18x18) 13.200.000 kcal/h 27

IRON & STEEL Steelworks Hatay, Turkey 28

ALUMINUM FACTORIES Akpa Aluminum Istanbul, Turkey 2HMP (12x12) 29

ALUMINUM FACTORIES Detal Aluminum Azerbaijan 2HMP (12x14) 4.800.000 kcal/h 30

MACHINERY INDUSTRY Bosch Manisa, Turkey HMP (12x14) 31

MACHINERY INDUSTRY Ortadoğu Bearing Ankara, Turkey 2HMP (14x16) 4.250.000 kcal/h 32

MACHINERY INDUSTRY AKO Battery Ankara, Turkey 3HMP (12x12) - 3.750.000 kcal/h 33