RG1,5SA Self Adhesive

Similar documents
SPIDER P SPIDER P mineral

SPECIAL SPECIFICATION 3687 Impermeable Liner

EFFISUS BRAZE MEMBRANE

FLAGON PVC FLAGON SV ROOFING SYNTHETIC MEMBRANES

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Impermeable Liner

Leadax B.V. Covenant K93792/02. Leadax

ENRGY CURB APPLICATION GUIDE FOR TPO ROOFING SYSTEMS

CAPPING OF A GOLD MINE IN ROSIA MONTANA, ROMANIA

SAUNA BARREL 3.0 m, Ø Plans: with and without terrace

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

Drop-In Specifications INTEGRATED DRAINAGE SYSTEM GEOMEMBRANE

MATERIAL SAFETY DATA SHEET FOR MOISTUREGUARD FOR CCA. 1.0 Introduction NZS 5433:1999.

Clean! Clean working by Qdel. Qdel laminating supplies Hamburgstraat 9 NL-7575 EG Oldenzaal T: E: I :

SLS Etch Primer. 300g aerosol, 250ml tin, 500ml tin, 1L tin, 4L tin

HG-2000E HEAT GUN WATTS

REHABILITATION OF SAIDA DUMPSITE

European Technical Assessment ETA-14/0176

PIPE MANUFACTURING CO.

Disposal Manual. m{zd{ 6. Capacitor( -ELOOP ) October 2012 Mazda Motor Corporation

Roofing Adhesive SARNACOL 2172 Spray

Firestone GeoGard EPDM Review of Technical Performances

Firestone EPDM Geomembrane Review of technical performances

Table of contents. Introduction Design. 2. Installation. Attachments

CONTINUOUS GEOMEMBRANES FOR ON SITE APPLICATION. PDA Europe 2012 Annual Conference Istanbul, November

Pot Belly Black. Overview. Suitable Surfaces

THE GOOD GUIDE TO BUTT FUSION JOINTING....Connect

Section Specification for Geotextile Used in Permanent Erosion Control Application

Dehydrator. This construction will dehydrate fruits and vegetables, helping preserve them and concentrating their flavour.

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

Textile quality management. Mr Dale Carroll CSIRO, Textile and Fibre Technology

ROOFING TECHNICAL BULLETIN #07-12

Facility Safety Rules Hazard Communication Emergency Procedures Fire Safety. Safety Orientation

Pizza Oven with Stand

Have a Question? Call toll-free: Owners Manual L WARNING. Project Series Paint Sprayers Important Safety Instructions

SpectraSeal 2.1 VOC Color Primer Sealer

INSTALLATION GUIDELINES FOR GEOTEXTILES USED IN FILTRATION AND DRAINAGE APPLICATIONS

GEOMEMBRANE FIELD INSTALLATION

SpectraPrime Color Primer Surfacer

FIRST-CLASS IN TRAINS

SYSTEM DATA SHEET Sikafloor MultiDur ES-44 ESD

LS-JRE OPERATION & INSTRUCTION MANUAL

Material Safety Data Sheet. acc. to ISO/DIS Printing date 01/26/2001 Reviewed on 03/28/2000

Installation Guide Maibec Regular Siding

Joint Stock Company Alzida Savanorių pr. 221, LT Vilnius, Lithuania

FRONT BUMPER COVER - VIN RANGE: H18680->H99999 (G )

HOT AIR GUN MODEL NO: CHG1500D USER INSTRUCTIONS PART NO: GC0414

Stormwater protection

43 May cause sensitisation by skin contact. 67 Vapours may cause drowsiness and dizziness.

EMERGENCY PHONE: or (651) (24 hours)

Liner Construction & Testing Guidance Overview

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

D.P.E. Enviroliner. geotextile protection layer. covering new ground 2016

PME. Series Enclosures. Battery Enclosure (BE) Field Upgrade Installation Instructions. Effective: January, Alpha Technologies

ARCHITECT S SPECIFICATIONS

SECTION (15820) - AIR DUCT ACCESSORIES

Geomembranes that work

Firestone Lining Systems. Dependable Performance in Demanding Environments

Safety Data Sheet. according to Regulation (EC) No 1907/2006 WICKES SMOOTH MASONRY

Safety Data Sheet. according to Regulation (EC) No 1907/2006. SECTION 1: Identification of the substance/mixture and of the company/undertaking

Urban Drainage Geomembrane (UDG)

Up on the Roof Fire Prevention BY David Laks, P. Eng., CFPS, ARM, RRC

ARCHITECT S SPECIFICATIONS For Commercial Vinyl Wallcoverings

Visqueen Vapour Control Tapes

Carbon Film Installation Instructions

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

SELF-ADHESIVE FILM INSTALLATION GUIDE

Geomembranes that work

MARATHON HEATER. File # E Made in USA

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INSET LIVE FUEL EFFECT GAS FIRE

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

POLICY STATEMENT: Policy Number: Section 600 Physical Plant. Date Adopted: May 7, Date(s) Revised: September 4, 2012

OPERATING AND SAFETY INSTRUCTIONS

GASEOUS HYDROGEN SYSTEMS

Blue Tuna Docs A Paper Plane Project Auditing of Composite and Metal Bonding Facilities. Part 1 Facility Control.

Design Options Analysis on a Heat Wrap used on PVC Pipe Connections in Cold Weather Conditions

Annex of the certificate (Page 1/5) Accreditation Scope

Chapter 18 Welding Table of Contents

Material Safety Data Sheet

TABLE OF CONTENTS. SI No Contents Page No.

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

ELECTRIC HEATING THERMOSYSTEM

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

owner s manual produitsneptune.com Do not discard. Save these instructions for further use.

Product Information Motor and machine protection

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

Automatic Water System Pump SERIES

Civil engineering Fibertex Geotextiles

PRODUCT SAFETY DATA SHEET

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

INSTALLATION GUIDE AND CHECKLIST

CHAPTER 8 OCCUPATIONAL HEALTH AND SAFETY

Patio Heater Model No. GM and GM

Rhepanol hg. For more information on SIG Design & Technology visit A solid foundation for green roofs.

Material Safety Data Sheet Masonite TM Hardboard

OWNER S MANUAL WISTERIA

Revision date: 22/4/2016 Date of print: 11/5/2016 Version: 1 Language: en-ca,us Page: 1 of 8

INSTALLATION & MAINTENANCE MANUAL FOR FLUE RENOVATION SYSTEM HT1000

Transcription:

Description of Product: Self adhesive membrane with a thickness of 1.5mm, consisting of rubberized bitumen with adhesive additives, glassfiber carrier, removable PP film at bottom and high density polyethylene film at top. Reinforcement: Glassfiber reinforcement gives Rumba excellent dimensional stability especially at hot weather conditions. Surface Finish: Siliconize Removable PP film at bottom and high density polyethylene film at top. Typical Application Areas: Applied on surfaces which are to be protected against water penetration: Roofs- protection of cement roofs, protection of wooden roofs, even with high sloping; protection of ventilated metal roofs. Concrete- Ideal for waterproofing concrete, masonry and wood surfaces where in-service temperatures will not exceed 54 C. Use with Bitumex Primers. Features and Benefits: Eliminated the need for torching or mopping Ensured quick, clean and easy lapping of rolls No open flame on your roof Clean and neat application Safe application 100% UV protected Basic Application Instructions: Applied Cold. Need primer application before membrane application. Surface Preparation and Priming: A fundamental requirement of any bituminous membrane system is that it must provide protection from all weather conditions likely to be experienced during its design life. All individual layers in a bituminous membrane system must be watertight, and together the whole system must be waterproof. Application area should be removed from stains and be smooth. For this purpose, Bitumen Primer needs to be applied on surface before application. Cover primed surfaces with self-adhered roofing membranes the same day.

Application of Membrane: Fully Adhered 1- Starting at the roof drains and vertical to the roof slope, apply the self-adhesive membrane without adhering in parallel lines. Unroll onto the below surface for alignment. Do not immediately remove the release sheet. 2. Overlap the membrane next to another along the side lap and the ends. Side overlap creates longitudinal overlap between two sheets. End overlap creates a join between shorter sides of the sheets To overlap at side laps, just remove the PP bant (7.5cm) and apply to the adjacent membrane pratically. Ensure full adherence. Stagger the end joints by a minimum of 61cm. 3.Release the PP film and adhere this part of the self-adhesive membrane to the surface. Relase PP film on the remaining part at a 45 angle to avoid wrinkles in the self-adhesive membrane sheet. 4. Overlap adjacent self-adhesive membrane by 9cm. Overlap end laps by 15cm. Stagger end laps by a minimum of 61cm. Finish with weighted roller to ensure a continuous adherence to the surface.

Safety Precaution: Bitumex products must be applied by qualified applicators who have received an adequate training, for the prevention and the protection (in particular for the use of the extinguishers) against accidents caused by the combustible or flammable materials, of liquefied propane gas, open flame and their material of installation. Check the construction and the composition of the systems of roof and the walls before applying. Ensure the cleanliness of the places. Use only proper torching equipment in perfect working order certified by local standard organizations. Use only proper hoses suited for propane gas of less than 15m. Verify and tighten all the connections before the use of the equipment. Do not light the torch if a propane odour is present. Never seek a leak with a flame. Use soapy water. Use a torch whose gas output is adjustable with a stopping device. Follow the specifications, notices and documentations of the manufacturer and site authorities. The wearing of gloves, long sleeves, long trousers, safety boots, helmet and safety glasses is recommended. Do not wear synthetic fabrics. Remove clothing contaminated with solvents. Avoid skin contact. Good working practices, high standarts of personal hygiene and plant cleanliness must be maintained at all times. Whilst using, do not eat, drink or smoke. In the event of any localised changes in appearance or texture of the skin being noticed, medical advice should be sought without delay. Contact with hot product will cause burns. Ensure good ventilation and avoid, as far as reasonably practicable, the inhalation and contact with vapours, mists or fumes which may be generated during use. If such vapour, mists or fumes are generated, their concentration in the workplace air should be controlled to the lowest reasonably practicable level. Avoid contact with eyes. Highly toxic hydrogen sulphide gas may be emitted from hot product and accumulate in enclosed spaces or tanks. Extreme care must therefore be taken during venting of closed spaces which have, at any time contained hot product. Under no circumstances should entry be made in to small enclosures without taking full precautions.

Storage: Flashings must be stored in such a way to prevent any creasing, twisting, scratches and other damages of the roof. The materials will be protected adequately and stored permanently away from flames or welding sparks, protected from bad weather and any harmful substances. Keep all membranes upright. 1. Rolls should always be stored and transported at upright position. 2. Membrane pallets should not be stored on top of each other and similarly, heavy loads should never be placed on membrane pallets. 3. Bituminous membranes should be stored at closed areas where room temperature is above +5C. They should never be stored outside as pallets are exposed to direct sun shine and should always be kept away from heat sources. 4. Membrane rolls should not be laid outside if there is no cover on them. High temperature may lead to longitudinal shrinkage and latitudinal expandage at membranes with polyester carrier. For bituminous membranes, recommended shelf-life is 12 months. Later than this date, membrane performance is diminishing. Packaging: Pallets are covered by UV Resistant White Shrinks Roll Size : 1mtx20mt 1,5mm Rolls per pallet: 25Rolls (By Container) and 30Rolls(By Truck)

Product Details Unit Tolerance RG1,5SA Modification of Bitumen Reinforcement Upper surface coating Lower surface coating TS EN 13707 Test Method Unit SBS Fibre Glass HDPE PP Removable Film Visual defects TS EN 1850-1 none Thickness TS EN 1849-1 mm ±0,2 1,5 Length TS EN 1848-1 m min(-0,03) 20 Width TS EN 1848-1 cm min(-2) 100 Straightness TS EN 1848-1 pass Watertightness (10kPa) TS EN 1928 10kPa pass Reaction to Fire TS EN 11925-2 E class External Fire Performance ENV 1187-2 NPD Watertightness after stretching TS EN 13897 NPD Peel resistance of joints TS EN 12316-1 N/50mm ±30% 38 Water vapour properties TS EN 1931 min 20 000 Tensile strength (MD/CMD) TS EN 12311-1 N/50mm 400/300 Elongation (MD/CD) TS EN 12311-1 % 2/2 Impact resistance TS EN 12691Mtd.A mm min 700 Tearing resistance (with nail) TS EN 12310-1 N/50mm ±20% 150 Dimensional Stability TS EN 1107-1 % max 0,6 Cold Bending TS EN 1109 C min -10 Flow Resistance TS EN 1110 C min 100 TS EN 13969 Impact resistance TS EN 12691Mtd.A min 700 Resistance to Chemicals Cold Bending TS EN 1109 C min -10 Tearing resistance (with nail) TS EN 12310-1 N/50mm ±20% 150 Sheer resistance of joints TS EN 12317-1 N/50mm ±20% 250 Water vapour properties TS EN 1931 min 20 000 Resistance to static loading TS EN 12730 Mtd.B Kg min 5 Tensile strength (MD/CMD) TS EN 12311-1 N/50mm 400/300 Elongation (MD/CD) TS EN 12311-1 % 2/2 Reaction to Fire EN 11925-2 NPD Dangerous Substances none none NPD