D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Similar documents
User s Manual. EJA Series Differential Pressure and Pressure Transmitters Installation Manual. 1. Introduction. 2. Handling Cautions. 3.

Tank Gauging System Special Safety Instruction

PumpSaver ISS-105 IS Super Cell Installation Guide

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

BA488CF Intrinsically safe Panel mounting Fieldbus Display

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

General Specifications

Certificate of Compliance

Declaration of conformity

Bettis Q-Series Control Module QC54 FOUNDATION Fieldbus

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Fieldbus Non-Incendive Concept takes FISCO into Zone 2 and Division 2 hazardous areas. Phil Saward

Certificate of Compliance

Certificate of Compliance

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

4) Intrinsic Safety Certification

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

DB5 Intrinsically Safe Sounder Type DB-5

SET Installation and Operating Instructions. Level switch for one sensor

ccsaus certificate: for GSI 127 Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title Page

INSTRUCTION MANUAL. Frequency-Pulse Converter, Repeater and Trip Amplifiers Din-Rail Model D1060S D1060S

Notes: Warrick Series 67 Intrinsically Safe Multi-Function Control Installation and Operation Bulletin

SET-2000 Oil/Sludge 12 VDC

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

AUTOMATIC TANK GAUGES

Certificate of Compliance

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Installing Foundation Fieldbus in Hazardous Areas. Understanding your Options and How to Use Them

Certificate of Compliance

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

Certificate of Compliance

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Certification Supplement Manual

Hazardous Area Classifications and Protections

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

CONTROL BE MADE CHANGES MAY NOT. Page 1

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Certificate of Compliance

Technical Data. Dimensions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

User s Manual. EJA Series Differential Pressure and Pressure Transmitters Manual Change No Yokogawa Electric Corporation

IECEx Certificate of Conformity

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

RT FLOW RATE TOTALISER

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Inductive slot sensor

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Annubar Flowmeter Series

srra, of Conformity IECEx Gert f cate ?-ot,b

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Certificate of Compliance

EU DECLARATION OF CONFORMITY

E2S Datasheet v10a

Mark* VIe and Mark VIeS Control Systems Equipment in Hazardous Locations (HazLoc) Instruction Guide

Certificate of Compliance

FAHM Co. Temperature Transmitter PTT74 Series

SET-2000 Hi Level/Oil

Operating Instructions Edition 02/2007

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Rosemount 3200HP. ph Sensors. Instruction Manual LIQ-MAN-3200HP Rev. G April 2017

Technical Information

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

Fire Alarm System Accessories

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Rosemount 2051 Pressure Transmitter with 4-20 ma HART and 1-5 Vdc HART Low Power Protocol

PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

PROZESSAUTOMATION. Manual SEGMENT PROTECTOR R-SP-!12. Zone 1 Zone 2 / Div 2 FNICO

CERTIFICATE OF COMPLIANCE HAZARDOUS LOCATION ELECTRICAL EQUIPMENT PER CANADIAN REQUIREMENTS

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

Intrinsically Safe Flame Detector Installation Guide

Technical Data. Dimensions

OOH740-A9-Ex Multi-sensor fire detector

Certificate of Compliance

OOH740-A9-Ex Multisensor fire detector

RMA 3000 Remote Meter Assemblies

for CE 134 CCSAUS certificate Meggitt SA Route de Moncor 4 PO Box 1616 CH Fribourg Switzerland Title page EN

Technical Data. Dimensions

Today's world of increasing

PROTEUS Series OEL8000III-K. Tank Gauging System. Installation Manual

standards: standards:

Rosemount 3900/3900VP

Rosemount 752 Fieldbus Remote Indicator

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Installationsmanual GWSL1100/2100, GWML3100

User s Manual YTA610 and YTA710 NEPSI Certification

OPTIBAR DP 7060 Supplementary Instructions

A Characteristics for Electrical Equipment integrated Into SLR Enclosure - Intrinsically Safe Reference Document

Instructions TXL Series Oxygen and Toxic Gas Detectors 4/

PROTECT SRB 200EXi-1A

FDOOT241-A9-Ex Multisensor fire detector

PEPPERL+FUCHS GmbH

Transcription:

FIELDBUS INTRINSICALLY SAFE CONCEPT (FISCO) APPROVAL FISCO allows interconnection of intrinsically safe apparatus to associated apparatus not specially examined in such combination. The criteria for interconnection is that the voltage (Ui or Vmax), the current (Ii or Imax), and the power (Pi or Pmax) which an intrinsically safe apparatus can receive and remain intrinsically safe considering faults, must be equal or greater than voltage (Uo, Voc or Vt), the current (Io, Isc or It) and the power (Po or Pmax) levels which can be delivered by the associated apparatus, considering faults and applicable factors. In addition, the maximum unprotected capacitance (Ci) and the inductance (Li) of each apparatus (other than the termination) conncected to the Fieldbus must be less than or equal to 5 nf and 10 uh respectively. In each I.S. Fieldbus segment only one active device, normally the associated apparatus, is allowed to provide the necessary energy for the Fieldbus. The voltage (Uo, Voc or Vt) of the associated apparatus is limited to a range of 14 V to 17.5 V. In this instance Rosemount 2410 has voltage as given in table below. All other equipment connected to the bus cable has to be passive, meaning that they are not allowed to provide energy to the system, except a leakage current of 50 ua for each connected device. Separately powered equipment needs galvanic isolation to assure that the intrinsically safe Fieldbus circuit remains passive. The cables used to interconnect devices need to have the parameters in the following range: Installation Notes: 1. FISCO allows the interconnection of Approved intrisically safe devices with FISCO parameters not specifically examined in combination as a system when: Uo, Voc or Vt =< Ui or Vmax, Io, Ioc or It =< Ii or Imax, Po =< Pi or Pmax 2. 1029 2 SME-699 111 FISCO Parameters: Uo (Voc) = 15.0 V; Io (Isc) = 54 ma; Po (Pout) = 5.2 W Control equipment connected to the Associates Apparatus must not use or generate more than 250 VRMS or VDC.. Dust tight conduit seals must be used when installed in Class II and Class III environments. Loop Resistance Rc: Loop Inductance Lc: Capacitance per unit length Cc: Length of trunk cable: Length of spur cable: 15...150 ohm/km 0.4...1 mh/km 45...200 nf/km Cc=Cc line to line + 0.5 Cc line to screen, if both lines are floating or Cc=Cc line to line + Cc line to screen, if screen is conncted to one line Less than or equal to 1 km for IIC (5km for IIB) Less than or equal to 60 m 4. 5. 6. 7. Earth connection. Minimum cable area 4 mm2 Field Apparatus manufacturers installation drawing must be followed when installing this equipment. Installation in the USA should be in accordance with ANSI/ISA-RP12.6 "Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations" and the National Electrical Code (ANSI/NFPA 70). It is possible to disconnect the integrated termination by means of a jumper located inside Rosemount 2410. At each end of the trunk cable an approved infallible line terminator with the following parameters should be installed: R >=90 ohm, C <=2.2 uf (recommended parameters are: R=100+/-2 ohm, C=1.0 +/-0.2 uf) One of the allowed terminations might already be integrated in the associated apparatus. Rosemount 2410 is equipped with integrated termination, see note 7. FISCO limits the number of passive devices connected to a single segment to 2 devices. If the above rules are respected, up to a total length of 1000 m (sum of trunk and spur cables) of cable is permitted. The inductance and capacitance of the cable will not impair the intrinsic safety of the installation.. The ENTITY CONCEPT allows the interconnection of Approved intrisically safe devices with ENTITY parameters not specifically examined in combination as a system when: Uo, Voc or Vt =< Ui or Vmax, Io, Ioc or It =< Ii or Imax, Po =< Pi or Pmax. ENTITY CONCEPT APPROVAL The Entity concept allows interconnection of intrinsically safe apparatus to associated apparatus not specifically examined in combination as a system. The approved values of max. open circuit voltage (Uo, Voc or Vt), max. short circuit current (Io, Isc or It) and max. power (Po or Voc Isc / 4 or Vt It / 4), for the associated apparatus must be less than or equal to the maximum safe input voltage (Ui or Vmax), maximum safe input current (Ii or Imax) and maximum safe input power (Pi or Pmax) of the intrinsically safe apparatus. In addition, the approved max. allowable connected capacitance (Co or Ca) of the associated apparatus must be greater than the sum of the interconnecting cable capacitance and the unprotected internal capacitance (Ci) of the intrinsically safe apparatus, and the approved max. allowable connected inductance (Lo or La) of the associated apparatus must be greater than the sum of the interconnecting cable inductance and the unprotected internal inductance (Li) of the intrinsically safe apparatus. WARNING - Substitution of components may impair Intrinsic Safety. WARNING - To prevent ignition of flammable or combustible atmospheres, disconnect power before servicing. AVERTISSEMENT - La substitution de composants peut compromettre la sécurité intrinsèque. AVERTISSEMENT - Ne pas ouvrir en cas de presence d'atmosphere explosive. 6 OrCAD 4 1 /

1029 2 SME-699 111 OR ZONE 1 / DIVISION 1, GAS GROUP C & D / IIB HAZARDOUS HAZARDOUS OPTIONAL INTRINSICALLY SAFE I/O UNSCIFIED CONTROL EQUIPMENT (Note 2) NON IS Notes:, 4, 5, 6, IS ANY APPROVED FISCO FIELD DEVICE APPROVED FISCO TERMINATOR (INSTALLATION OVERVIEW) 4 2 /

1029 2 SME-699 111 OR ZONE 1 / DIVISION 1, GAS GROUP C & D / IIB HAZARDOUS HAZARDOUS 7 (24/4 VDC, 4, 65 and 100-240 VAC, ATEX / IECEx: Zone 1 US / Canada: Division 1 or Zone 1, GAS GROUP C & D or IIB Secondary S PWR - S PWR + S BUS B S BUS A FB- FB+ Tank Bus FISCO Note 1, see sheet 1 6 OrCAD (BASIC) 4 /

1029 2 SME-699 111 OR ZONE 1 / DIVISION 1, GAS GROUP C & D / IIB HAZARDOUS HAZARDOUS 4 5 6 7 (24/4 VDC, 4, 65 and 100-240 VAC, ATEX / IECEx: Zone 1 US / Canada: Division 1 or Zone 1, GAS GROUP C & D or IIB Alarm + Alarm - SIL Alarm input Note 1, see sheet 1 FB- FB+ Tank Bus FISCO Note 1, see sheet 1 SIL Alarm Relay ALARM B ALARM A 6 OrCAD (SIL OPTION) 4 4 /

1029 2 SME-699 111 OR ZONE 1 / DIVISION 1, GAS GROUP C & D / IIB HAZARDOUS HAZARDOUS 4 5 6 7 (24/4 VDC, 4, 65 and 100-240 VAC, Secondary Installation Notes (cont.): 9. S PWR - S PWR + S BUS B S BUS A The IS I/O cable and the FB cable shall be treated as separate intrinsically safe circuits. (HART/4-20mA ACTIVE ENTITY IS I/O OPTION) 4 5 /

1029 2 SME-699 111 OR ZONE 1 / DIVISION 1, GAS GROUP C & D OR IIB HAZARDOUS HAZARDOUS 4 5 6 7 (24/4 VDC, 4, 65 and 100-240 VAC, SIL Alarm Relay Installation Notes (cont.): 10. ALARM B ALARM A The IS I/O cable and the FB/Alarm cable shall be treated as separate intrinsically safe circuits. (SIL OPTION AND HART/4-20mA ACTIVE ENTITY IS I/O OPTION) 4 6 /

1029 2 SME-699 111 OR ZONE 1 / DIVISION 1, GAS GROUP C & D / IIB HAZARDOUS HAZARDOUS 4 5 6 7 (24/4 VDC, 4, 65 and 100-240 VAC, Secondary Associated Apparatus (Note 2, 5, 6, and, See sheet 1) S PWR - S PWR + S BUS B S BUS A (HART/4-20mA PASSIVE ENTITY IS I/O OPTION) 4 7 /

1029 2 SME-699 111 OR ZONE 1 / DIVISION 1, GAS GROUP C & D / IIB HAZARDOUS HAZARDOUS 1 2 4 5 6 7 (24/4 VDC, 4, 65 and 100-240 VAC, SIL Alarm Relay Associated Apparatus (Note 2, 5, 6 and, See sheet 1) ALARM B ALARM A (SIL OPTION AND HART/4-20mA PASSIVE ENTITY IS I/O OPTION) 4 /