heat interface unit L nt In partnership with: n
imensions C C A B B A E Introduction The heat interface unit is the latest intelligent range of HIU from Altecnic. The is the complete solution for instantaneous hot water production and space heating control. esign The twin plate design hydraulically separates both domestic and space heating from the central primary supply. The internal electronic control unit ensures maximum efficiency and control but also incorporates other additional important features. The standard unit can be set to hold a stable heating flow temperature, to suit the installation (radiators, UH for example), but crucially, can also be set to vary the heating flow temperature automatically depending on the temperature of the heating return water. This allows the unit to automatically compensate for changes due to external influences, such as outside temperature etc. thereby ensuring that the unit and the system operate at maximum efficiency The unit also features a pump bypass to protect the pump, in case of complete radiator TRV shutdown. The is extremely compact in design and lightweight, benefitting both installers and architects. The unit has a fully insulated front cover, manufactured from expanded PPE, which includes a sliding window to allow the tenant to access the integral heat meter (if installed). The unit can be fitted with an optional isolation module which allows the domestic hot water (HW) and heating circuits to be remotely isolated by the building owner/landlord etc. via a computer with internet access. Connection A B C Thread G¾B G½B GB E epth inc. Cover kg 6 6 6 9 Technical Specification Component Materials rame: Painted steel ront cover: PPE Expansion vessel; Steel Connecting pipework: Stainless steel Pump: UPS /6 Electronic controller: V - Hz Performance Maximum working pressure: 6 bar - primary bar - secondary Maximum temperature: 8 C Medium: Water Operation The temperature setting operates on the principle of set point regulation and can be fixed within application limits. Set Point - to 7 C omestic Hot Water - HW The HW function takes priority over the heating function controlled by the HW priority flow switch (component ). Set Point - HW temperature to 6 C Heat exchanger capacity: up to kw
bar HW CH AULT Components 9 7 9 8 Schematic 6 7 8 Components Item Component Primary isolation valve rain cock Heat meter spool piece - replaced by heat meter when fitted Primary filter and heat meter probe pocket circuit on/off valve 7 Modulating primary control valve (HW) 8 Plate heat exchanger (HW) 9 HW temperature sensor HW flow switch Electronic control unit Room controller (not supplied) Plate heat exchanger (space heating) flow temperature sensor Temperature control stat 6 Strainer (heating circuit) 7 Pump safety bypass and P switch 8 Pump 9 Expansion vessel Safety relief valve - bar return temperature sensor Pressure gauge illing loop isolation valve* illing loop double check valve* illing loop* * Not shown on Components illustration 7 8 9 HW CW Primary R 6 9 8 7 R
HW CH AULT HW CH AULT HW CH AULT Hydraulic Characteristics - primary side low Path - primary side Pressure loss - kpa Kv =.8 m/h...6.8..... lowrate - l/s Hydraulic Characteristics - secondary side low Path - secondary side H HR 6 Kv =.6 m/h Pressure loss -kpa......6 lowrate -l/s UPS - 6 pump settings H HR HW - heat exchanger HW - heat exchanger Pressure loss - kpa Kv =. m/h...6.8..... lowrate - l/s
omestic Hot Water Output,,, Primary low Rate - l/h, 8 6 6 7 8 9,, omestic Hot Water low Rate @ 8 C - l/h Primary flow temperatures C 6 C 6 C 7 C 7 C 8 C 8 C Key to Symbols Primary circuit flow Primary circuit return omestic hot water outlet omestic cold water inlet circuit flow circuit return E & O.E Lanten Metering Services Ltd Units J & K Maybrook Industrial Estate Maybrook Road, Brownhills, Birmingham West Midlands. WS8 7G Tel: 8 77 ax: 8 77797 Email: sales@lantenltd.com www.lantenltd.com L nt n