SATK 30 heat interface unit

Similar documents
Herz York Direct Heat Interface Unit

IDEAL LOGIC HEAT INTERFACE UNITS (HIUs) PRODUCT GUIDE.

heat interface units A BOILER WITHOUT A FLAME

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

INSTALLATION AND SERVICING

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

heat interface units A BOILER WITHOUT A FLAME HIU Single PHE options

T. +44 (0) E.

ModuSat TP. Energy. Heat Interface Units

ModuSat TP. Energy. Heat Interface Units

Installation and Commissioning Manual

Hot Water Energy Storage THE HOT WATER PEOPLE HEAT INTERFACE UNIT ENGINEERED FOR ULTIMATE HEATING COMFORT AND MAXIMUM SYSTEM EFFICIENCY

SATK50-60 series CONTENTS. Recess Mounted Heat Interface Unit - SATK series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Contact person Date Reference Page Daniel Månsson P07886C-rev2 1 (14) Energy and bioeconomy

HYDRAULIC SEPARATION. Product Range

T. +44 (0) E.

SEALED THERMAL STORE

This manual must be kept with the appliance

Contact person Date Reference Page Daniel Månsson P07886B-rev2 1 (14) Energy and bioeconomy

THE REMEHA HIU RANGE Installation, operation and maintenance manual December 2017

FASTflo. Working towards a cleaner future

Contact person Date Reference Page Daniel Månsson P (13) Energy and circular economy

SUPERIOR QUALITY HEAT INTERFACE UNITS PUTTING YOU IN CONTROL. Pegler Yorkshire

Contact person RISE Date Reference Page Daniel Månsson P (13) Energy and circular economy

Systems for central heating

Contact person Date Reference Page Björn Folkeson P (14) Energy and bioeconomy

Stored Water District Heating Interface Units. Heat Interface Units

Metering systems 0548EN April 2014

Wall-mounted compact indirect heat interface unit SATK30 series Safety instructions Dimensions Technical specifications Installation Commissioning

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

Contact person RISE Date Reference Page. Daniel Månsson P (13) Energy and circular economy

Contact person RISE Date Reference Page Björn Folkeson P (13) Energy and circular economy

GIACOMINI HEAT INTERFACE UNITS

Contact person Date Reference Page Daniel Månsson P07886E-rev2 1 (14) Energy and bioeconomy

Heat Interface Units for decentralised water heating in district heating systems

anti-condensation valve

System Design for efficiency using electronic, intelligent HIU s. Neil Parry CIBSE Accredited Heat Network Consultant

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model EGIS - AS. R EN - Edition 03-01/03/2008

PROPAK THERMAL. Packaged Plate Heat Exchanger

Meibes Heat Interface Unit (HIU) A2RXE Instantaneous Hot Water & Space Heating

Contact person Date Reference Page Björn Folkeson P (15) Energy and bioeconomy

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Brute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

CRIMSON & CRIMSON MAX

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

HI-MAX STORE Installation, operation and maintenance manual

Where gas is not an option,

GB24 & GB30. User Manual

Our Boiler Family Our Boiler Family

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Contact person RISE Date Reference Page Björn Folkeson P03675B 1 (11) Energy and circular economy

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

Domestic hot water (DHW) The substation can be supplied with connection pipes for DHW cylinder on the supply or return line.

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Sirius FS. Working towards a cleaner future

NEW. Hydronic HVAC Systems. FloCon Watchman TM. Patent Numbers: GB , GB , GB Rev: /2015

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

HT V2 HT Split

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

INSTALLATION & TECHNICAL MANUAL

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

TERMO ELECTRIC BOILER INSTALLATION MANUAL OSO TERMO RS -M

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

Ultramax PB. Floor standing premix gas fired condensing boilers with outputs at 65, 85, 100 & 120kW BOILERS

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

TABLE OF CONTENTS TECHNICAL DOCUMENTATION 03. Technical Data Electrical Details Connection Details Dimensions Standing Losses

AC WhisperGen System Product Specification 11 June 2003

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

ADVANCE ECB ELECTRIC COMBINATION BOILER

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Design & Product Guide. Danfoss FlatStations.

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

CITY OPEN - CITY BOX from 25 to 35 kw

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

Technical documentation Fan coil unit

Pressurisation units & expansion vessels

Electric Flow Boiler

Installation & Technical Guide. Domestic & Commercial.

Troubleshooting & faults guide

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

USER MODULES SIRIUS SAT M-BUS MODELS TRANSMISSION OF CONSUMPTION VIA CABLE INSTALLATION AND OPERATING MANUAL

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

Unvented water heaters

ECONOPLATE H1-heat only HEAT INTERFACE UNIT. Installation, Commissioning and Servicing Instructions for unvented systems.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

HIGH POWER. VICTRIX PRO 2 ErP. High power, wall-hung condensation boiler

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

INSTALLATION & TECHNICAL MANUAL

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

The Ultimate Solution for Electric Central Heating. Fusion. Comet

Transcription:

heat interface unit L nt In partnership with: n

imensions C C A B B A E Introduction The heat interface unit is the latest intelligent range of HIU from Altecnic. The is the complete solution for instantaneous hot water production and space heating control. esign The twin plate design hydraulically separates both domestic and space heating from the central primary supply. The internal electronic control unit ensures maximum efficiency and control but also incorporates other additional important features. The standard unit can be set to hold a stable heating flow temperature, to suit the installation (radiators, UH for example), but crucially, can also be set to vary the heating flow temperature automatically depending on the temperature of the heating return water. This allows the unit to automatically compensate for changes due to external influences, such as outside temperature etc. thereby ensuring that the unit and the system operate at maximum efficiency The unit also features a pump bypass to protect the pump, in case of complete radiator TRV shutdown. The is extremely compact in design and lightweight, benefitting both installers and architects. The unit has a fully insulated front cover, manufactured from expanded PPE, which includes a sliding window to allow the tenant to access the integral heat meter (if installed). The unit can be fitted with an optional isolation module which allows the domestic hot water (HW) and heating circuits to be remotely isolated by the building owner/landlord etc. via a computer with internet access. Connection A B C Thread G¾B G½B GB E epth inc. Cover kg 6 6 6 9 Technical Specification Component Materials rame: Painted steel ront cover: PPE Expansion vessel; Steel Connecting pipework: Stainless steel Pump: UPS /6 Electronic controller: V - Hz Performance Maximum working pressure: 6 bar - primary bar - secondary Maximum temperature: 8 C Medium: Water Operation The temperature setting operates on the principle of set point regulation and can be fixed within application limits. Set Point - to 7 C omestic Hot Water - HW The HW function takes priority over the heating function controlled by the HW priority flow switch (component ). Set Point - HW temperature to 6 C Heat exchanger capacity: up to kw

bar HW CH AULT Components 9 7 9 8 Schematic 6 7 8 Components Item Component Primary isolation valve rain cock Heat meter spool piece - replaced by heat meter when fitted Primary filter and heat meter probe pocket circuit on/off valve 7 Modulating primary control valve (HW) 8 Plate heat exchanger (HW) 9 HW temperature sensor HW flow switch Electronic control unit Room controller (not supplied) Plate heat exchanger (space heating) flow temperature sensor Temperature control stat 6 Strainer (heating circuit) 7 Pump safety bypass and P switch 8 Pump 9 Expansion vessel Safety relief valve - bar return temperature sensor Pressure gauge illing loop isolation valve* illing loop double check valve* illing loop* * Not shown on Components illustration 7 8 9 HW CW Primary R 6 9 8 7 R

HW CH AULT HW CH AULT HW CH AULT Hydraulic Characteristics - primary side low Path - primary side Pressure loss - kpa Kv =.8 m/h...6.8..... lowrate - l/s Hydraulic Characteristics - secondary side low Path - secondary side H HR 6 Kv =.6 m/h Pressure loss -kpa......6 lowrate -l/s UPS - 6 pump settings H HR HW - heat exchanger HW - heat exchanger Pressure loss - kpa Kv =. m/h...6.8..... lowrate - l/s

omestic Hot Water Output,,, Primary low Rate - l/h, 8 6 6 7 8 9,, omestic Hot Water low Rate @ 8 C - l/h Primary flow temperatures C 6 C 6 C 7 C 7 C 8 C 8 C Key to Symbols Primary circuit flow Primary circuit return omestic hot water outlet omestic cold water inlet circuit flow circuit return E & O.E Lanten Metering Services Ltd Units J & K Maybrook Industrial Estate Maybrook Road, Brownhills, Birmingham West Midlands. WS8 7G Tel: 8 77 ax: 8 77797 Email: sales@lantenltd.com www.lantenltd.com L nt n