Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS. Domestic applications

Similar documents
ADE Gen4. Speech Dialler Engineering Information. Description. Features

Accenta/Optima. User Guide. UK Security Panels. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number:

Master User Guide Premier Elite Series

Shortform Product Guide & Price List. Security. CCTV Detectors Intruder Panels Accessories

Installation Manual Premier 412/816/832. Issue 10

CONTENTS. 1 INTRODUCTION 2 Planning the installation 2 Nexus 8 installation example 3

SECURIT 700L PLUS ENGINEERING MANUAL

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Security Control Panel with Communicator Interface

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

M800, M800iD Plus, M1000 and M3000. User's Guide

Intruder alarm system Operating Instructions

HARDWIRED CONTROL PANELS

ACP10 & ACP50 Security Systems

2000 SERIES DIAGNOSTIC ALARM CONTROL SYSTEM

User Guide. Contents. About this guide. i-on Style Security System

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

GARDTEC 580. Installation Instructions

Installation Manual RINS1211-4

TS5160. Installation & User Guide. Compatible Equipment. CPA6 0M - Output Module Loudspeaker DC54/58 - Digital Communicators (Stand Alone Only)

AP10LED 10 Zone onboard LED Alarm Panel. Engineering Manual

EC-P Zone Intruder Alarm System

Electrical Intruder Products Catalogue A complete range of reliable intruder products for all your security needs.

Security System With Scheduling. User Guide. N5943-8V4 7/04 Rev A

Engineer Reference. EN :2006+A1:2009 EN :2009 EN :2008 EN :2005+A1:2008 Security Grade 2 Environmental Class II

Security Alarm Systems

Intruder alarm system Operating Instructions

HARDWIRED CONTROL PANELS

Galaxy Flex V3. User Guide. Honeywell Security. This user manual is located at

Master User Guide. Premier 412/816/832. Issue 8

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

PCX 46 App Programming Reference

8 plus and16 plus. User s Guide * # ent. esc GALAXY 16+ V2.XX TUE 30 JUN. IU ZST 962 Issue 2. A u B u

Scantronic Leading the way in security

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The complete wirefree security alarm solution

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Control/Communicator Installation Manual

TS2500. Intruder Alarm Control Panel. SYSTEM OPEN 17:30 01 Jan ENT ESC. Setting the System. Unsetting the System RE SET

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

PARAGON PLUS USER INSTRUCTIONS USER INSTRUCTIONS J?>5 J?>5 J?>5 J?>5 J?>5 J?>5 B??=

Wireless security products

2200 and 2200L ALARM CONTROL SYSTEMS

Intruder - Fire - Water Combined Alarm

USER GUIDE HARDWIRED CONTROL PANELS

THIS GUIDE SUPPORTS MATRIX 424 & 832 CONTROL PANELS

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

Safewatch Pro 3000 System Manual

Contents. Introduction... 2 Mains Safety... 2 Good Working Practice... 2

CPA6. Installation & User Guide. Intelligent Security & Fire Ltd. Compatible Equipment

USER GUIDE HARDWIRED CONTROL PANELS

Intelligent Security & Fire Ltd

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

security timeless design innovative products inspired technology

INSTALLATION GUIDE. For products. Gardtec 370 & 581

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Matrix Installation Manual. Software Version 4. EN Security Grade 2 Environmental Class 2 RINS918-1

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

Input Type: 42: Medical: This is a 24 Hr type input it will activate the external sounder and report a CID event 100.

Introduction. When using an LED keypad for Abacus 6P (or some older Abacus panels) refer to the LED Operator instructions guide (Part No. Y6055).

Control/Communicator

/10 Rev A

CC408. Quick Reference Guide Solution 880

PYRONIX LIMITED, Pyronix House, Braithwell Way, Hellaby Rotherham South Yorkshire S66 8QY England

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

System 800 Addressable Fire Detection & Alarm System

Welcome to. Welcome to Security and Peace of Mind CASTLE CARE TECH CARE TECH CARE TECH CARE TECH

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

LS800S Intruder Alarm System. Engineering Manual

Advantage 6 Alarm Panel

THANK YOU FOR VOTING TEXECOM THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels 1 INS167

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

THANK YOU FOR VOTING TEXECOM USER GUIDE. Security Control Panels

TS690 & TS690ID. Intruder Alarm Control Panels. SYSTEM OPEN 17:30 01 Jan ENT ESC

VISTA-50P VISTA-50PUL

SCORPION Z16040C, Z8040C and Z5120C

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C

Scantronic Leading the way in security

16 and 16 plus User s Guide

IDS S E C U R I T Y IDS816. User Manual. MANUAL NO A ISSUED November 2004 VERSION 1.00

Warning: Mains voltages are present inside control unit. No user serviceable parts inside.

TS700. Intruder Alarm Control Panel. Installation & Programming Instructions OPEN

USER MANUAL CEF AP28 CONTROL PANEL

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

VISTA-20PMT. Security. Systems. User s Guide. Monitronics

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

ZSC100 Gas Detection and Alarm System Controller

USER GUIDE HARDWIRED CONTROL PANELS

User s Guide FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA. K5309-5V5 11/08 Rev. A OFF 3 STAY 2 AWAY 1 OFF A B C D 5 TEST 8 CODE 9 CHIME FA260 # FA560

Intruder alarm panel Terxon MX Operating instructions

SECURIT 703 USER MANUAL

9,67$36HULHV 6HFXULW\6\VWHPV 8VHU*XLGH K5309-1V1 7/02

CC488. Quick Reference Guide Solution Ultima 880

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Contents. Glossary

L900 series USER MANUAL

Transcription:

Gen4 Domestic Intruder Panels RELIABLE AND FLEXIBLE INTRUDER PANELS Domestic applications

Overview and features 8 Zones Each one is separately identified on the keypad and provides ample security detection for most domestic properties. 3 part set programs Allows three programmed setting levels dependent on the people in the property or the level of protection required, eg. night-time with upstairs detectors off and perimeter detectors on. Simple set readers for ease of operation Up to 4 stylish readers can be used to SET/UNSET the system with the option of using a proximity keyfob. Ideal for young, elderly or infirm. A haven of peace and security that s what your home should be, but when it really matters it s best to be safe, not sorry. An unprotected property is a vulnerable one at any time, day or night. Every home needs the protection of a reliable alarm system, but sometimes people are put off by the prospect of false alarms or complicated setting procedures. At Honeywell we understand these concerns. Honeywell Optima/ Accenta products have been installed in over 3 million homes in the UK. Our latest range, with the same level of reliability and conformity to CE specification directives, comes with a sleek new LCD display keypad. Coupled with an intuitive menu interface, using and programming the panel is even easier. Personal attack facility PA buttons may be used to activate the system in an emergency. An additional PA facility exists on the remote keypads. Remote keypads for added flexibility Up to four slimline keypads can operate the system from any point in the property. 5 Digi-Outputs For a wire-in digital communicator, RedCare STU or Dialler. This allows the system to communicate with an Alarm Receiving Centre (not fitted on Optima Compact Gen4). New LCD Keypad The LCD remote keypad operates with the Accenta and Optima Gen4 intruder systems. Up to four LED or LCD keypads can be connected to the system. The large 2x16 characters with backlight display provide a full status indication and the keypad plays entry and exit tones. Fire Zone Zones 7 and 8 may be programmed as a 24 Hour Fire Zone operating all of the time except during engineer mode.

Gen4 Accenta / Opt 250-event log The last 250 events to have occurred are stored in the memory and can be displayed, with their date and time, on the LCD remote keypad screen. Duress Code Allows the user to unset the system and silence the alarm under duress, using a second code that will communicate an alarm to an Alarm Receiving Centre. Chime Can be used to select a low security chime alarm for various areas of your house, even when the main alarm is turned off. When a door is opened or a detector triggered in an area set to chime, the control panel will deliver a low-volume bing-bong sound to alert you. This is ideal for areas that require low level monitoring. Remote Keypad / Simple Set connections (up to 4) Fully programmable 8 zones over 3 programs On board sounder to assist local alerts / service warning *Optima panels only Zone names selectable from the library A new option accessible from the LCD remote keypad allows the installer to assign descriptors from a 22-name library to each of the eight zones. Built-in tamper control To protect all wiring and detectors in the system from unauthorised access including the control panel and remote keypad covers. Multiple cable entry points Up to 2.1AH battery compartment Styled robust polycarbonate enclosure Digital communicator outputs (not on Optima Compact Gen4) Supports speech dialler extension Non Volatile Memory (NVM) for protection of engineer program Tamper protection Panic attack input Extension speaker capability Fuse protected outputs

ima On-board keypad with Backlighting (Optima Variants only) Accenta Metal Gen4 8 Zone Remote LCD Keypad Communicating Large Metal Case Accenta Gen4 mini 8 Zone Remote LED Keypad Communicating Compact case Bell / Strobe outputs List No. 8EP396A 8SP400A 8SP399A 8SP401A 8SP411A 8SP420A Optima Compact Gen4 Accenta Mini Gen4 with LED keypad Accenta Mini Gen4 with LCD keypad Accenta Gen4 with LED keypad Accenta Gen4 with LCD keypad Accenta Metal Gen4 with LED keypad Optima Compact Gen4 8 Zone On-Board Keypad Compact case 8SP419A LGSIX/01 LOGIC 6 Accenta Metal Gen4 with LCD keypad

Accessories Accenta LED RKP Up to four keypads per control panel Illuminated keys Can be mixed with Accenta LCD keypads Keypad Type Operating Voltage Current Consumption LED 11 to 15V 40mA Temperature Range 0 to 50ºC Construction Dimensions List No White 3mm polycarbonate W 122mm H 85mm x D 28mm On-board PA facility Full LED status indication Entry / Exit tones 8EP 416 Suitable for use on Optima Compact Gen4, Accenta Gen4, Accenta Mini Gen4 Accenta LCD RKP Up to four keypads per control panel Can be mixed with Accenta LED keypad Full LCD status indication Illuminated keys PA keys Entry/Exit tones Keypad Type 2x16 characters LCD English text display Operating Voltage 10.5V to 14.8V Current Consumption 70mA max Temperature Range 0 to 50ºC Construction White 3mm polycarbonate Dimensions W 135mm H 105mm D 25.5mm List No 8EP417A Suitable for use on Optima Compact Gen4, Accenta Gen4, Accenta Mini Gen4 Informa 3 phone numbers + follow me Recorded message stored in memory Master message + 3 trigger messages Negative Input Trigger voltage Positive Input Trigger voltage Current Consumption Message Length Dialling Method <1.0V 3.5V to 15V max 20 seconds message recording Trigger inhibit for use with Bells only alarm systems Last event memory recall 50mA quiescent (200mA maximum when operating) 20 Seconds (11 seconds master, 3 seconds per trigger message) DTMF (tone) Ren Value REN = 1 Dimensions Operating Temperature 0 to 60ºC List No 8EP276A W 148mm H 115mm D 32mm Suitable for use with any control panel from the Honeywell range

Simple set reader / keyfob Up to 4 Simple Set readers per panel No Master Keyfob for ease of programming Can be mixed with Accenta keypads Reader Relay output for keyswitch input panels Up to 8 Keyfobs per Reader Full mimic of panel / keypad sounds Operating Voltage 11 to 15V from Panel Reading Distance Nominally 20mm Current Consumption 100mA max Relay Contacts 100mA max current capability Construction White 2mm ABS Dimensions W 118mm H 84mm x D 22mm Keyfob Power Inductively powered Material Polycarbonate (no batteries) List No List No SS/01 Reader with 2 keyfobs SS/F Keyfob Specifications Optima Compact Gen4 Accenta Gen4 / Metal Gen4 Accenta Mini Gen4 On board keypad & display Yes No No Simple Set Interface Yes RKP Indication Yes (not supplied) Yes (supplied) 8 Zones +ve loop, fully programmable Tamper -ve loop global PA -ve loop Bell Output 12V latching, timed 1 to 99 minutes Strobe Output 12V Extension Speaker Max two 16 Ohm Entry/Exit Timers Programmable 10 to 990 seconds Zone Input Delay 300 or 800ms selectable Set +ve Output Source 10mA, sink 40mA CPU Current consumption 55mA 45mA (standby) RKP Current consumption 25mA (standby) Low voltage output 13V +/- 5% Rechargeable battery Up to 2.1Ahr Up to 7Ahr Up to 2.1Ahr Communicator outputs No Yes Yes Communicator output types Intruder, PA, Fire, Abort, Set PCB Fuses 1 x 1.6A, 3 x 1.0A Mains input fuse 125mA anti-surge Total current output 1 Amp when supported by fully charged battery Mains supply voltage 230V +/- 10% RKP wiring 6 core Max distance 100m Dimensions CPU (HxWxD) 200 x 253 x 55mm 230 x 290 x 80mm (Accenta Gen4) 255 x 300 x 85mm (Accenta Metal Gen4) 200 x 253 x 55mm Honeywell Security and Custom Electronics Newhouse Industrial Estate Motherwell Lanarkshire ML1 5SB Scotland Tel: +44 (0)1698 738200 Fax: +44 (0)1698 738300 www.honeywell.com/security/uk HSCE-GEN4-01-EN(0107)SB-E January 2007 2007 Honeywell International Inc.