Mimic display driver, LED ribbon cable

Similar documents
Multi line separator module

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Input module, input/output module

Output module (230 V)

Input module, input/output modules

Interbases. Sinteso FDSB221, FDSB228, FDSB229

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

FDOOT221, FDO221, FDT221

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

OH720, OP720, HI720, HI722

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FDOOT241-9, FDOOT241-A, FDO241, FDT241

ASA linear smoke detector

DM1131 / DM1133 / DM1134 Manual call points

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDCL221-Ex Line adapter (Ex)

Fire control panels FC360

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDCIO223 (ES 45) Transponder

FDCL221-M Multi line separator module

FDOOT241-A9-Ex Multisensor fire detector

Fire control panel for modernization

SWING radio fire detection system

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

Fire control panels FC726 FC726-XA

FC722 Fire control panel

FDCW241 Radio gateway Mounting

DT1101A / DT1102A / DO110xA Automatic fire detectors

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Electronic timeswitch

FC724 Fire control panel

DF1101-Ex Infrared flame detector

Radio fire detection system

FC722 Fire control panel

FDBZ290 Air sampling smoke detection kit

FC724 Fire control panel

Test units and accessories

FDBZ290 Air sampling smoke detection kit

Room thermostat with 24-hour time switch and large LCD

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

OOH740, OOHC740 Automatic fire detectors

Frost Protection Thermostat

Call stations and extensions

FC723 Fire control panel

OOH740-A9-Ex Multisensor fire detector

FDA241, FDA221 Siemens ASD

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

FDCL221 Line separator

FDA241, FDA221 Siemens ASD

OOH740-A9-Ex Multi-sensor fire detector

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

DC1192 Input /Output module

1592P01. for liquids in piping DN

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Test units and accessories

FC2020 Fire control panel

FDCI221, FDCIO221 Input module, input/output module Technical Manual

FP120-Z1 Power supply kit A (70 W) Technical Manual

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Duct Temperature Sensors

Room Temperature Controllers

Flush-mounted room thermostat

Room Temperature Sensors

XC10 Extinguishing control panels

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

FS20 Fire detection system

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

FDM273 Radio manual call point Mounting

Frost Units for air temperature monitoring

Room thermostat with Auto Timer, independent DHW

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Room Temperature Controller

Flush-mounted room thermostats

DF1151-Ex Infrared flame detector

FS720 Fire detection system (marine) Technical Manual

Room thermostats with LCD RDD100..

Semi flush-mount room thermostats

FDA241, FDA221 Aspirating Smoke Detector Technical Manual

RVL479. Heating Controller. for use with a partner unit

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FDL241-9 Linear smoke detector Mounting Commissioning

Fume Hood Operating Display Panel

Sinteso TM product catalog.

Building Technologies. FDUL221 en Line tester operating instructions for electricians

Room thermostat with independent DHW control

FT2010 Floor repeater terminal Operation Manual

DOW1171 / DCW1151 Radio fire detection system

FDS229 Alarm sounder with supplementary optical indication Technical Manual

Wall-mounted room thermostat with LCD

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Test units and accessories

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Transcription:

Sinteso / Cerberus PRO Mimic display driver, LED ribbon cable FT2001-A1, F50F410 FDnet/C-NET mimic display driver and LED ribbon cable for the fire detection systems Sinteso FS20 and Cerberus PRO FS720. Mimic display driver for a total of 48 LED indicators (without housing) 2 LED ribbon cables F50F410 with 24 red LEDs can be connected 2 control outputs for local buzzer and LED operating status display 2 inputs for the 'Silence buzzer' and 'LED test' function buttons Mimic display driver can be connected via FDnet/C-NET Installation in customer housing 2018-09-28 Control Products and Systems

Features and Functions FT2001 mimic display driver Can be connected via FDnet/C-NET Power supply via FDnet/C-NET Outputs are freely programmable 2x 24 outputs for controlling LEDs on mimic displays 3 outputs for expanded periphery 2 control outputs for local buzzer and LED operating status display 2 inputs for the 'Silence buzzer' and 'LED test' function buttons Integrated line separator External, electrically isolated AC/DC supply possible MC link connection socket for firmware update F50F410 LED ribbon cable* For connection to the mimic display driver FT2001-A1 50-pin 24 red LEDs 1 m long * must be ordered separately 2

Use The mimic display driver FT2001 is mounted on a carrier plate and is designed for installation in any customer housing. The LED ribbon cable F50F140 allows the LEDs to be connected to the mimic display driver and for the LEDs to be positioned anywhere on the front panel in accordance with the building plan. Example of use 4 2 3 1 8 7 6 5 1 Customer housing 2 Mimic display driver FT2001-A1 3 LED ribbon cable F50F410 4 Customer mimic display 5 'LED test' button 6 'Silence buzzer' button 7 Local buzzer 8 LED indicator: Operating status 3

Design Setup Mimic display driver FT2001 2 1 3 7 3 6 4 5 4 1 Mounting plate with mounting holes and spacer bolts 2 Connection for FDnet/C-NET and separate supply 3 LED ribbon cable 'F50F410', 50-pin with 24 red LEDs, 1 m 4 Connector for the connection of 2 x LED ribbon cables F50F410 5 Connection terminal for supply and operating status LED 6 Connection terminal for expanded periphery 7 Mimic display driver FT2001-A1 4

Details for ordering Type Designation Weight Order number FT2001-A1 Mimic display driver 0.232 kg A5Q00014417 F50F140 Ribbon cable for mimic display driver FT2001-A1 0.108 kg BPZ 5291410001 Product documentation Document ID Title 008836 FS20 Fire Detection System - System Desription 008837 FS20 Fire detection system - Product Data 008838 Operation Manual Fire control panel / Fire terminal FC20xx / FT2040 008843 FS20 Fire detection system - Planning 009052 FS20 Fire detection system - Commissioning, Maintenance, Troubleshooting 009078 FS20 Fire detection system - Configuration A6V10210355 A6V10210362 A6V10210368 A6V10210416 A6V10210424 A6V10211076 FS720 Fire detection system - System Description FS720 Fire detection system - Planning FS720 Fire detection system - Product Data FS720 Fire detection system - Commissioning, Maintenance, Troubleshooting FS720 Fire detection system - Configuration Operation Manual Fire control panel / Fire terminal FC72x / FT724 Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: https://siemens.com/bt/download Notes Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. 5

Technical data FT2001-A1 FDnet/C-NET Operating voltage Max. operating current Max. quiescent current Max. capacitive load to ground Max. capacitive load to ground with external supply Supply External supply input DC 16 33 V 45 ma 5 ma C = 500 nf C = 100 nf DC 14 32 V, electrically isolated, EN54-4 conformity not required AC 11 22 V, electrically isolated, EN54-4 conformity not required Key figures Address connection factor AK = 1 Quiescent current connection factor RK = 16 Maximum current connection factor: Without external supply: With 24 LEDs With 36 LEDs With 48 LEDs MK = 52 80 MK = 68 130 MK = 80 165 With external supply MK = max. 16 Outputs Operation LED (X8; 'LED_1') Max. output current 2.5 ma constant at Usys (12 32 V) Driver outputs (X11/X12) Max. output current with LED operation Buzzer (X5/5.6) 2.5 ma and DC 2.5 V Max. output current 5 ma and DC 12 V Connections LED signal outputs Connection terminal 0.08 1.5 mm 2 Ambient conditions Operating temperature 0 40 C Storage temperature -20 +60 C Air humidity Plug-type connection with flat-ribbon cable 95 % rel. 6

FT2001-A1 Mechanical data Dimensions (W x H x D) Min. protection category (IEC 60529) of the housing (provided by the customer) Standards and approvals 106 x 200 x 45 mm IP30 Standards EN 54-17, EN 54-18 Approvals: VdS G208044 LPCB 126bp/01 DNV GL (marine) Sinteso : See document A6V10400920 Cerberus PRO: See document A6V10339425 08 0786 FT2001-A1 Siemens Schweiz AG; Theilerstrasse 1a CH-6300 Zug Technical data: see doc. 008837, A6V10210368 FT2001 - Input/output device incl. short-circuit isolator for use in fire detection and fire alarm systems installed in buildings. 305/2011/EU (CPR): EN 54-17 / EN 54-18 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2011/65/EU (RoHS): EN 50581 The declared performance and conformity can be seen in the Declaration of Performance (DoP) and the EU Declaration of Conformity (DoC), which is obtainable via the Customer Support Center: Tel. +49 89 9221-8000 or https://siemens.com/bt/download DoP No.: 0786-CPR-20378; DoC No.: CED-FT2001 7

Dimensional drawings Mimic display driver FT2001-A1 23 106 60 23 45 120 200 40 5 M3 x 10 40 Issued by Siemens Switzerland Ltd Division International Headquarters Theilerstrasse 1a CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2008 Technical specifications and availability subject to change without notice. 8 Document ID FS20 / FS720 Edition 2018-09-28