SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS

Similar documents
SENSITIVE ENOUGH TO DETECT RUNOFF CHANGES IN GROUNDWATER TRITIUM PLUMES

MODEL 1925-PR TRITIUM HEAVY WATER LEAK DETECTOR

LOW MINIMUM DETECTABLE ACTIVITY (MDA)

NEX-BETA-ABG FACILITY Drinking Water Safety Monitor

MODEL 321/421 NUCLEAR POWER PLANT TRITIUM MONITOR

TRITIUM IN WATER MONITOR REAL TIME CONTINUOUS Model # LIQ-X-(H3)

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

MODEL 421 NUCLEAR POWER PLANT TRITIUM MONITOR

A Continuous Air Monitoring Sampler for 125 I - RIS-125

Greentrol Automation, Inc.

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

AM-806. Waste/Door Radiation Monitor OPERATIONS MANUAL

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

ph COOLING TOWER CONTROLLER

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Section PERIMETER SECURITY SYSTEMS

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

FireNET Plus Wiring Instructions

Model 17A00 Expansion Enclosure

Radiation Monitoring Systems

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

HEALTH AND SAFETY MANUAL

LAUNDRY MONITORING SYSTEM Model # LIM-64S

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Ronan Model X90 Series Point Level Monitor

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

GRAPPLE SCANNER FOR RADIATION IN SCRAP METAL. Model Series ~ GRAPPLE SCAN- GR Models ~ GRAPPLE SCAN- GR-A, -B, -C, & -D

Power Supply Display Module PSDM. Installation and Operation Manual

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

Quality Assurance/ Quality Control. Topic 4 - Audio 46. Key Points

Development of a Novel Contamination Resistant Ionchamber for Process Tritium Measurement and use in the JET First Trace Tritium Experiment

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Passive Whole Body Monitoring Nuclear Power Industry Application Introduction to the Argos -5AB Zeus (Gamma Option) and the GEM

Identify the following features and specifications for the ESP1

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Fundamentals is subdivided into Sources of Radiation, Biological Effects, Mathematics, Chemistry, Physics, and Units and Terminology.

MODEL AND MODEL GAS PROPORTIONAL DETECTORS. December 2016 Serial No and Succeeding Serial Numbers

National Atomic Energy Commission ( NATEC ) Radiation Exposure and Laboratories General Directorate

F-1100 Series Single Turbine Meters Suitable for pipe sizes 1 ¼ and larger.

Software Failure Mode and Effects Analysis of Concept Phase for Radiation Monitoring System Digital Replacement

300/400 UNITS - MODULAR CONFIGURATION

Instruction Manual for the Revolutionary Science RS-PB-200 Dual Poly Pro Bath

MANUAL RESET ALARM RELEASE

Lead-Lined Cabinetry. 7 Vreeland Road, Florham Park, NJ or

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

LUDLUM MODEL 44-3 LOW ENERGY GAMMA SCINTILLATOR. May 2018 Serial Number PR and Succeeding Serial Numbers

Installation Manual CARBONATOR With Plain-Water Booster

FlexPS. Architectural & Engineering. Specification for FlexPS. Architectural/Engineering Specification for a

RC4000 Radiation Detection System

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

SERIES 101T MOISTURE ANALYZER QUICK START GUIDE

Using the Model 1500 Portable Chilled Mirror Hygrometer

ORP/MILLIVOLT CONTROLLER

PORTABLE DEW POINT MONITOR

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

22 Radiological and Environmental Monitoring Systems Functions, Basic Configuration, and Interfaces

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

When reliability is vital. Alemite Carbon Shield TM Systems deliver

D7024 Fire Alarm Control Panel

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

MODEL B2 INSTALLATION MANUAL

Installation and Operating Instructions

Central Chillers TS Series

Radiation Training for Ancillary Personnel. Introduction

Troubleshooting Thermo Scientific LevelPRO Gauges

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section CHLORINE GAS LEAK DETECTOR

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Ronan Model X96S Series Density System

DS7400Xi Addressable Control/ Communicator

Intelligent 2 & 4 Loop Fire Alarm Control Panels

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

EVO192 v3.0 Fire and Burglary What s New

Portable Instruments For First Response & In-Situ Analysis of Radiation

MANUAL RESET ALARM RELEASE BOX

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

ECC-50/100C. Emergency Command Center

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

COUNTING ROOM EQUIPMENT RCT STUDY GUIDE

Radiation Monitoring Equipment

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

X-Ray Protection Program

Note To The User: This product has updated features not yet mentioned in the product manual.

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Series 5000 Hydrazine Analyzer Model 60002

Air Check O 2 Deficiency Monitor

INTERNATIONAL STANDARD

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Transcription:

SENSITIVE ENOUGH TO DETECT RUNOFF FROM SECRET NUCLEAR PLANTS MODEL 1925 HEAVY WATER LEAK DETECTOR (HWLD) CONTINUOUS FLOW TRITIUM IN WATER SURVEY MONITOR MODEL 1925-HWLD TRUCK OR TRAILER MOUNT AVAILABLE 1160 US ROUTE 50 MILFORD, OHIO 45150-9705 TELEPHONE (513) 248-2400 FACSIMILE (513) 248-2402 E-MAIL Overhoff- Technology@cinci.rr.com VISIT US AT http://www.overhofftechnology.com

MODEL 1925 - HEAVY WATER LEAK DETECTOR LOW LEVEL REAL TIME TRITIUM-IN-WATER MONITOR SENSITIVITY OF 1.0 kbq PER LITER MINIMUM DETECTABLE ACTIVITY (MDA) OF 3.7kBq/L FOR REGULATORY COMPLIANCE REQUIREMENTS This monitor has been designed for real time low-level detection of tritium in water in the industrial environment of nuclear power plants. Low MDA, reliability, ruggedness and simplicity of operation is what sets this monitor apart from laboratory type of the equipment. The primary purpose of the Model 1925 is to detect the leak of heavy water in nuclear power plants that utilize CANDU reactors; however, it can be used for other purposes such as monitoring changes in tritium content of ground water, rivers, lakes or ocean currents. LOW MINIMUM DETECTABLE ACTIVITY (MDA) The unit detects tritium decay with Photo Multiplier Tubes (PMT) working in coincidence mode. Use of highly effective PMTs, specially designed sampling cell to minimize cosmic radiation and Cherenkov effects and 1" lead shielding provide for low background noise of only One Count Per Second and sample counting efficiency of 40%!!! Listed MDA is 3.7kBq/L; however, the unit has been tested as low as 1.7kBq/L. FAST RESPONSE TIME The unit is equipped with up to 6 inputs for sampling 6 individual lines. The response time from the moment when sample enters the system to the moment the unit starts to respond is 2.5-3.0 minutes and in 9.0 minutes the full value of tritium concentration in the sample is displayed on the screen. Each sample line is sampled for 10 minutes so that the effect of residual activity from the previous line is minimized. 1160 US ROUTE 50 MILFORD, OHIO 45150-9705 TELEPHONE (513) 248-2400 FACSIMILE (513) 248-2402 E- MAIL Overhoff-Technology@cinci.rr.com VISIT US AT http://www.overhofftechnology.com REMOTE MONITORING AND ALARMING The instrument is equipped with 4-20mA output for remote monitoring as well as with 2 alarm outputs and malfunction outputs in the form of dry, fail-safe, relay contacts. Alarms are adjustable and by default are set at 100kBq/L (Hi Alarm) and 110kBq/L (Hi-Hi Alarm). Malfunction alarms activate in case of the electronics and/or mechanical failures in the system. HWLD:PAGE 2

DATA RECORDING The instrument is equipped with Serial Data Recorder that utilizes Microdrive card to store up to five years worth of readings in daily files. This information is in text format that is easily extractable to Excel for analysis and graphic presentation. PRESSURE REGULATING EQUIPMENT Pressure of input sample streams can be up to 15psi. This pressure is immediately reduced to 2-3psi via Pressure Regulating Valves (PRV). Each PRV is associated with Pressure Relieve Valve set to open at 14.5psi, therefore, the pressure in the system can never be more than 14.5psi, which makes it safe to handle. This also makes the instrument Class 6 Nuclear Device. FULLY INTEGRATED PACKAGE Model 1925 is a completely self-contained instrument for real time observation of tritium concentration in water. The instrument is mounted inside of the 7' tall steel enclosure with reinforced anchoring feet and locked access. Liquid scintillator is connected to the unit externally and it is stored inside of the polyurethane drum of 65 gallons. Currently this quantity of liquid scintillator is sufficient for 60 days of continuous, 24/7 operation. The main subassemblies are: 1. Sample water input lines 2. External cooling loop input/output lines 3. Internal cooling loop complete with chiller, chiller pump and plumb ing 4. PRV and RV system with manifolds 5. Water purification system (oil-in-water and micron filter) 6. Sample water pump 7. Detection module 8. Data acquisition electronics module 9. System control module 10. Waste water output line, RV output line and sample bypass output lines COOLING SYSTEM In order to have maximum efficiency of the liquid scintillator, solution that is tested inside of the sample cell is kept between 12 C and 20 C. This is achieved by internal cooling loop system, which is a closed loop cooling system with its own pump and chiller unit. If the unit operates in extreme temperatures (more than 45 C) external cooling loop is provided, where user can provide chilled water from its own source. HWLD:PAGE 3 1160 US ROUTE 50 MILFORD, OHIO 45150-9705 TELEPHONE (513) 248-2400 FACSIMILE (513) 248-2402 E-MAIL Overhoff-Technology@cinci.rr.com VISIT US AT http://www.overhofftechnology.com

PLC CONTROL Sampling of input lines and control of alarms and pumps is done by PLC unit placed inside of the System Control Module. There is an alarm provided in case of PLC failure as well as manual override so that the operation can be continued manually until PLC is replaced. Manual operation is a backup system; the unit normally operates in automatic mode. ROUTINE MAINTENANCE Scheduled maintenance of consumables is required. Liquid scintillator needs to be replenished every 2 months and sample water filters need to be replaced. Also, periodic check of the efficiency and background is recommended if there is a possibility of increased background contamination and due to standard lifecycle of electronics components. ANNUAL INSPECTION AND SERVICE It is recommended that the instrument be inspected and serviced on an annual basis to ensure continuing trouble free operation. All components of the instrument should be inspected and instrument re-calibrated. REPAIR Equipment failures of a minor nature can be repaired under local supervision by the operator of the equipment. When necessary, the manufacturer (Overhoff Technology Corporation (OTC)) can dispatch service personnel for quick remediate action. DOCUMENTATION All OTC equipment is accompanied by complete documentation, which includes the following: 1. User and Maintenance Manual that contains: a. Theory of operation b. Installation instructions c. Operation instructions d. Calibration procedure e. Suggested maintenance f. Repair instructions g. Drawings, diagrams and schematics Training will be provided by the manufacturer, free of charge. Assistance with commissioning is also available by the manufacturer (OTC). HWLD:PAGE 4 1160 US ROUTE 50 MILFORD, OHIO 45150-9705 TELEPHONE (513) 248-2400 FACSIMILE (513) 248-2402 E-MAIL Overhoff-Technology@cinci.rr.com VISIT US AT http://www.overhofftechnology.com

MODEL 1925 TECHNICAL SPECIFICATION ELECTRONICS AND MEASUREMENT MEASUREMENT RANGE: 3.7kBq/L - 130kBq/L RESOLUTION (SENSITIVITY): 1.0kBq/L MINIMUM DETECTABLE LIMIT: 3.7kBq/L at confidence level of 95% DISPLAY: 6 DIGITS FLUORESCENT DISPLAY RESPONSE RATE: 2.5-3.0 min beginning of the response, 9.0 min full value displayed MEASUREMENT METHOD: Liquid Scintillation Counting DETECTOR: Dual PMT coincidence counter surrounded by multielement shielding SIGNAL PROCESSING: MEASUREMENT ALARM SET POINT: Electronic signal processing of coincident pulses for tritium specific wave shapes (height and duration) Can be manually adjusted DATA RECORDING: Serial Data Recorded with Microdrive card HWLD:PAGE 5 1160 US ROUTE 50 MILFORD, OHIO 45150-9705 TELEPHONE (513) 248-2400 FACSIMILE (513) 248-2402 E- MAIL Overhoff-Technology@cinci.rr.com VISIT US AT http://www.overhofftechnology.com

SAMPLING SYSTEM SAMPLING/MIXING SYSTEM: Dual head, single shaft low flow rate pump providing flow of sample and liquid scintillator. Mixing is done at the T- joint and at the entrance on the sample cell. SAMPLE CELL: WASTE Stainless steel cell, volume 5cc with fused silica windows and Viton O-rings for sealing. MANAGEMENT: Waste water output lines with Swagelok fittings are provided, user to provide waste collection system. ENVIRONMENTAL TEMPERATURE: 0 C to 50 C HUMIDITY: 0 to 95 % R. H. SEISMIC: Withstands modest shock GENERAL: ELECTRICAL: MECHANICAL: DIMENSIONS: Equipment to be sheltered from exposure to raw elements. Power 110/230VAC, 5A main power, +24VDC for 4-20mA and connections for the remote alarms and monitoring Self contained, mounted on a steel frame with lifting eyes for easy transport. 31.5in x 23.6in x 84.0in (800mm x 600mm x 2133mm) WEIGHT: 1100 lb (~500 kg) HWLD:PAGE 6 1160 US ROUTE 50 MILFORD, OHIO 45150-9705 TELEPHONE (513) 248-2400 FACSIMILE (513) 248-2402 E-MAIL Overhoff-Technology@cinci.rr.com VISIT US AT http://www.overhofftechnology.com