Fino Healthcare Asymmetric Wall Mount Indirect LED Features fiture is ideal for applications requiring a wipe down lens with no horizontal "shelf" surfaces. Designed with an integrated acrylic lens to protect the light source, promotes a crisp, comfortable work environment. At only 5/8 deep, Fino runs seamlessly across the walls without the need to cut wall studs, leaving ceilings pristine clean creating a beautiful visual impression. Eperience precision and comfort like never before! Product Overview Type: Asymmetric, Wall Mount, Indirect Healthcare, Wipe down lens Wattage: 6W/ft, 2W/ft (other wattages consult factory) Lumen Output:,2 ma; 79.5 Lm/W (6W, 4ft fiture) Color Temp: 27K, K, 5K, 4K CRI: 8 typ. (27K, K, 5K, 4K) : -V, % dimming (standard) Lutron Hi-lume % dim, EcoSystem or wire (Dim Hot) Lutron Hi-lume 2 wire (2V only) Lutron Hi-lume EcoSystem, % dim, fade to off Lutron Hi-lume 5 Series DALI dimming,.% dim Fiture Summary (see following pages for more information) Performance Chart Wattage Per Foot Delivered Lumens LPW Color Temp 6 94 8.8 K 2 2 79.5 K Data is based on K-8 IES files available on website Data is based on fiture Runs Individual Runs: ' - (to nearest 6") Continuous Runs: Available (to nearest 6") Electrical Data Wattage System System Per Foot Watts Amps Watts Amps 6 2V 2.8.2 47.9 277V 25.6.9 47.5.7 2 2V 5.4.82 277V 5..8.6.6 Electronic multi-volt (2277V), constant current LED driver LIT-266 8/25/7 Page of 7
Ordering Information FINO-HC-A6 HW 2/277 2 4 5 6 7 8 9 2 4 5 6 7 8 Model FINO-HC-A6 Wattage (per foot) 6 2 Consult factory for other wattage options Color Temp 8 CRI: 27-27K-8 - K-8 5-5K-8 4-4K-8 92 CRI optional, consult factory Finish HW - high reflectance matte white Voltage 2/277 Length - specify length (for individual fiture, 8" to in 6" increments) (for continuous run, specify to nearest 6") Configuration IND - individual fiture, 8" to in 6" increments CON - continuous run > than, specify to nearest 6" s -V - % electronic dimming, multi-volt (2277V) constant current driver (standard). HILUME-A-ECO-DH - Lutron "A" Series, % dim, EcoSystem or -wire (Dim Hot) HILUME-A-LTE - Lutron "A" Series, % dim, 2-wire, 2V only HILUME-H-ECO - Lutron "H" Series, % dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DALI - DALI 2277V,.% dim 9 Options/Accessories REMOTE - remote driver Additional - Lengths less than may have restrictions based upon wattage, lengths, drivers or other options. The "A" refers to the sequential revision in a year and "" refers to the year of update. Updates coincide with improved performance while not changing the overall fiture aesthetic and are reflected in the published performance data. Please contact your Amerlu representative for eplanations of changes. LIT-266 8/25/7 Page 2 of 7
Specifications Application Especially developed for healthcare facilities, wipe down lens and no horizonal surfaces allow for easy cleaning. Can be used for uplight or downlight applications Construction Two piece assembly: ) Etruded aluminum mud-in frame and sheet metal die-formed gear tray. 2) Snap-in Reflector etruded aluminum optical assembly. Positive latching system for hairline seams. Optical Engineered optical system with internal asymmetric high reflectance white reflector and vertical wipe down cover lens. LED Amerlu's boards and patented connector design with brand name LEDs enables Amerlu fitures to have ecellent thermal management and offer a year warranty. Our LED binning is within MacAdam ellipse. Boards are configured for maimum fleibility resulting in even illumination no matter what the fiture layout. LED boards are easily replaced in the field with just a Phillips screw driver. Color Temperature Options: 27K, K, 5K, 4K CRI: 8 typical, 92 optional - consult factory R9: 6 @ CRI 8 R9: >5 @ CRI 92 Life: 5,+ hr., > 7% of initial lumens (L7) Electrical Wattage: 6W/ft, 2W/ft (consult factory for other wattages). Electronic constant current LED driver: 6 watts - 8" min fiture length, 96" maimum length. 2 watts - 8" min, 48" maimum length Wiring: Must daisy chain minimum 6" of fiture for short runs. s are not connected internally. voltage must be brought to each remote driver bo from a J bo (by others) or from an adjacent powered driver bo. Low voltage power from each remote driver bo must be brought into the fiture separately. See page 4 for wiring illustration. Optional remote location of -V driver, up to '. Remote Lutron drivers limited to 5'. Emergency circuit via remote inverter or auiliary emergency power supply (by others). This product complies with IEEE C62.4 for surge endurance up to 2.5KV. Amerlu recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. s -V - % electronic dimming, multi-volt (2277V) constant current driver (standard). Cap leads for non-dim applications. Optional s: HILUME-A-ECO-DH - Lutron "A" Series, % dim, EcoSystem or -wire (Dim Hot) HILUME-A-LTE - Lutron "A" Series, % dim, 2-wire, 2V only HILUME-H-ECO - Lutron "H" Series, % dim, fade to off, EcoSystem HILUME-5-ECO - Lutron "5" Series, EcoSystem DALI - DALI 2277V,.% dim Note: is accessible by removing snap-in reflector assembly. Finish HW - High reflectance, matte white powder coat paint. Baked on finish for maimum durability and color stability. Configurations/Lengths Straight lengths only. IND - Individual fitures are made of single standard lengths of 8" to (in 6" increments). These are stand alone fitures. Lengths less than may have restrictions based upon wattage, lengths, drivers or other options. CON - Continuous runs > than, specified to nearest 6" increments. Each Housing/mud-in frame has factory installed alignment pins. Mating frames are easily aligned and joined with "catch and latch" mechanisms. Wiring is made fast and positive with molded quick connectors. Mounting FINO-HC-A6 - Intended for gypsum board wall - "mud in" finish required. Certifications Approved to UL standards for damp locations as tested by CSA. Intended for indoor use only IC rated Warranty Amerlu's market leading year limited warranty. Please consult Amerlu website for details. LIT-266 8/25/7 Page of 7
FINO HEALTHCARE compartment, fits between studs, sliding lateral adjustment (5 /6" long) Mount in wall any orientation /4" 2 /6" Wipe down lens LED Module Uplight 5 /6" /8" 2" 2 /6" 5 /6" /4" /2" access by removing optical system tray Downlight 5/8" Cut Out Dimension: fiture = 5 /8" 4" Continuous runs = 5 /8" fiture length + " INTEGRAL DRIVER (for every fiture section) located on the back of fiture is field adjusted for installation in between wall studs. or 2 drivers per fiture required (see table ). voltage Power Feed (by others) must be brought to each enclosure. Table Ma. W/ft Min. Length 2 -V 6W 2W Lutron 6W 2W DALI 6W 2W REMOTE (for every fiture section, optional) requires an enclosure. 2 drivers per fiture may be required see Table 2. Note: () per enclosure.fitures are provided with low voltage plenum rated 8/2 cable for field connection (by others). Remote driver ma distances are listed on Table 2. Table 2 Ma. Ma. Remote W/ft Min. Length 2 Distance -V 6W 2W Lutron 6W 2W DALI 6W 2W '-6" '-6" '-6" '-6" '-6" '-6" '-6" '-6" '-6" '-6" ' ' 5' 5' ' ' Enclosure Dimensions: 5 /4" 2 /2" 2 /4" Feather Detail Standard Individual Wiring Power Feed (by others) Standard bo up to (2W/ft) up to (6W/ft) Power Feed (by others) Standard bo -6" - (2W/ft) Remote Individual Wiring Low voltage plenum cable (supplied) Power Feed (by others) up to (2W/ft) up to (6W/ft) -6" - (2W/ft) Power Feed (by others) Short Runs (on one remote driver): multiple short fiture lengths can be wired (daisy chained) to a single. Cumulative fiture lengths must equal the MIN length per criteria and be divisable by 6". (see Table ) W/ft Min. Length # of s 6" Section 2" Section -V 6W 2W Lutron 6W 2W DALI 6W 2W '-6" '-6" '-6" '-6" '-6" '-6" Note: Consult factory for additional remote driver requirements not show. 2 2 Table Short Run Remote Unit Wiring Enclosure Low voltage plenum cable (supplied) Dimensions: Custom low voltage Amerlu junction bo (supplied) 5 /4" 2 /2" 2 /4" Power Feed (by others) 2" 2" 2" LIT-266 8/25/7 Page 4 of 7
FIXTURE DATA: (Complete photometric data (.ies format) available upon request) FINO HEALTHCARE 2W K 4FT Total Watts: 48 Total Lumens:,2 (28 Lm/ft) Source: 2 LED's LTL# 775 MULTIPLYING FTORS: (Multiplying Factor is based on K-8 2V IES file on website) Wattage: 6W 2W CCT: 27K-8 K-8 5K-8 4K-8 Factor:.6. Factor:.9..8.5 8 65 5 5 2 5 5 5 2 9 5 45 6 75 ZONAL LUMEN SUMMARY Zone Lumens %Fit -4 46. -6 24 5.7-9 88 2.4 9-8 2 78.6 Efficacy = 79.5 Lumens /Watt COEFFICIENTS OF UTILIZATION Effective Floor Cavity Reflectance 2% RC 8 RW 7 5 RCR 427 427 427 427 626 99 96 2 25 2898 265 259 296 255 272 97 4 2665 288 89 572 5 2429 926 574 5 6 2224 79 6 5 7 246 528 92 95 8 888 7 49 827 9 75 242 9 72 627 29 8 62 LIT-266 8/25/7 Page 5 of 7
DIMMING COMPATIBILITY: Amerlu Fino fitures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlu recommends testing your unique dimming configuration as the eact full configuration (Dimmer, Fiture Quantity, Voltage, etc) may affect dimming performance. -V - DIMMING (Standard) Integrates into a variety of building management and daylighting controls 2V or 277V* Dims down to % light output Requires interface to turn off power to driver Consult manufacturer for installation instructions - DO NOT SHARE NEUTRALS! -V Wiring Diagram -V Gray -V (-) -V (+) Switched Hot Wall Bo Lutron Diva - DVTV with PP- 2H Interface Leviton Renoir II -v Lutron Grafik Eye with GRX-TVI Interface LUTRON HI-LUME DIMMING Integrates into Lutron EcoSystem building management HILUME-A-DH -Wire Wiring Diagram 2V or 277V* Dims down to less than 5% light output May use -Wire or EcoSystem Consult manufacturer for installation instructions - DO NOT SHARE NEUTRALS! Cap unused ECOSYS wires -Wire Phase Stripe Orange E E2 Dimmed Hot Switched Hot Wall Bo (-Wire Fluorescent) DIVA Maestro Nova T Vareo HILUME-A-ECO, HILUME-H-ECO, HILUME-5-ECO EcoSystem Digital Wiring Diagram E2 E Lutron EcoSystem compatible controls EcoSystem (Cap off Orange wire) Stripe Orange ECOSYS Bus E E2 Dimmed Hot Switched Hot * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 2V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. LIT-266 8/25/7 Page 6 of 7
DIMMING COMPATIBILITY: Amerlu Fino fitures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlu recommends testing your unique dimming configuration as the eact full configuration (Dimmer, Fiture Quantity, Voltage, etc) may affect dimming performance. LUTRON HILUME-A-LTE DIMMING Utilizes Standard incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications where TRI dimmers are installed. 2V only Dims down to less than % light output (most cases) Consult manufacturer for installation instructions - DO NOT SHARE NEUTRALS! Must meet dimmer Minimum Load Requirements per dimming manufacturer Wall Bo (Incandescent Style, Wattage as required) Lutron Diva Lutron Vareo Lutron Nova-T Lutron Skylark Lutron Maestro Lutron HILUME-A-LTE Wiring Diagram TRI ETC SR Rack w/d2 Module Lutron GP Panel ETC DRD Rack w/d2 Module Lutron Grafik Eye QS DALI - DALI DIMMING 2277V Digital control protocol allows individual fiture control DALI Wiring Diagram 2V - 277V* Dims down to.% light output in most cases DALI /WT DALI Bus Wall Bo (-Wire Fluorescent) Leviton CD25 ler Dynalite Fifth Light * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 2V wiring colors and method. Please refer to 277V dimmer installation instructions for 277V wiring diagrams. LIT-266 8/25/7 Page 7 of 7