Air cooled industrial chillers

Similar documents
EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Air cooled industrial chillers with Scroll compressors and R410A refrigerant Cooling capacity kw Cooling your industry, optimising your process.

Ultimate energy saving technology

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

HYDRONIC RESIDENTIAL

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

PYXIS U PYXIS U. rcgroupairconditioning

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

KELVIN Clim F497. Kelvin air conditioning

Conditioning your ambient, maximising your comfort.

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

ULTIMATE ENERGY SAVING TECHNOLOGY

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

CHAPTER 6 CONDENSING UNITS

NEXT DL NEXT DL. rcgroupairconditioning

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

PRODUCT GUIDE

Blue Box Epsilon Echos +

MAC N-407 Air-Cooled Chiller

GLIDER EVO GLIDER EVO. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Ultimate energy saving technology

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

GLIDER EVO CLA GLIDER EVO CLA HIGHEFFICIENCY ACLASS. rcgroupairconditioning

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

PURESTREAM CHILL-CUBE TM BY FRIULAIR

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

LZT High efficiency air to water heat pumps with E.V.I. compressors

pyxis u pyxis ua NEW rcgroupairconditioning

Superchiller Product Documentation. English. cod rev Issued by TDS

Aquaflair TRAC-TRAF-TRAH

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

unico turbo FL unico turbo FL LOW NOISE A-CLASS INVERTER rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

unico pf unico pf rcgroupairconditioning

Galletti Water chillers and heat pumps catalogue

UNICO TURBO FL FREE UNICO TURBO FL FREE HIGHEFFICIENCY INVERTER ACLASS FREECOOLING LOWNOISE. rcgroupairconditioning

PRODUCT DOCUMENTATION

MACH N-407 Heat Pump Air-Cooled Chiller

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Next MTR kw. technicalcatalogue. Air conditioners for Metrology Labs with upflow air delivery T_NXTMTR_0511_GB

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES


AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

SyScroll Air EVO NEW

H4T R410A. refrigerant

glider evo cla glider evo cla A-CLASS rcgroupairconditioning

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Technical Catalogue. Multi-Scroll Air-Cooled Liquid Chillers. Nominal cooling capacity: kw 50 Hz

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Cooling your industry, optimising your process.

LZA High efficiency air to water heat pumps with HP compressor

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Modular Air-cooled Chillers

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

kw. technicalcatalogue

AQUASNAP JUNIOR 30RHV

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

EQSL TECHNICAL CATALOGUE AIR COOLED WATER CHILLER UNITS AXIAL FANS. Models: 300 V2 F V2 F16. Cooling capacity: 299 to 1310 KW

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Air-to-water scroll chillers

MAC-120HE-03 Air-Cooled Chiller

21,8 222 kw COOLING 25,2 236 kw HEATING

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

ERAH MC Ka. Range kw. AIR COOLED CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS FOR OUTDOOR INSTALLATION (Standard line)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

next p dw next p dw rcgroupairconditioning

Kelvin air conditioning. KELVIN Clim W250. Cooling Capacity: 250 ~ 1240 kw

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

1

Water chillers water/water type SIGMA Technical information manual

EQEF TECHNICAL CATALOGUE AIR COOLED WATER CHILLERS AXIAL FANS WITH FREE-COOLING SYSTEM

Transcription:

Air cooled industrial chillers

Main features R410A refrigerant Cooling capacity 5 175 kw Air cooled industrial chillers Models Versions HE High Efficiency Finned coil evaporators submerged in the storage tank Scroll compressors Unique parametric microprocessors IC208CX. Single circuit with ne or two compressors (mod.015-401) Dual circuit with four compressors (mod.402-802) Electronic thermostatic expansion valve (optional) Phase monitor standard Compressors crankcase heaters standard Data declared according to EN14511:2011: cooling*: evaporator: 12/7 C; ambient temperature35 C

4 Versions Standard version 50Hz (mod. 015-802) Eurovent Energy class: C Power supply 400V/3/50Hz Standard version 60Hz UL (mod. 015-802) Power supply 460V/3/60Hz Versions Dual frequency version (mod. 015-161) Eurovent Energy class: C Power supply 400V/3/50Hz 460V/3/60Hz High efficiency HE version (mod. 031-702) Eurovent Energy class : A Increased condensing surface EC brushless fans standard Electronic expansion valve as option

Overview mod. 015-602 Axial fans - Centrifugal fans mod, 031-161 (option) - EC brushless high head pressure axial fans (option 201-602) Structure and panels made of carbon steel, galvanized and powder coated IP 54 electrical panel IC 208CX electronic controller Condensing coils with aluminum fins and copper tubes Finned coil evaporator installed inside the water storage tank Scroll compressors Thermostatic expansion valve - electronic expansion valve (option) P3/P5 centrifugal pumps - Double pump P3+P3/P5+P5 (option) - SP without pump

Overview mod. 702-802 Axial EC brushless fans (option) Electrical panel IP 54 grade protection Condenser coils on two sides. Tubes are made of copper and the corrugated fins are made of aluminium New high efficiency evaporator Scroll compressors (tandem) 2 Cooling circuit New frame with panels made of galvanized carbon steel sheet. Painting by epoxy polyester power coating. Electronic expansion valve (option)

Overview mod. 702-802 The expansion tanks are located inside the cavity (protected against impacts)

Cooling capacity Cooling capacity [kw] 200 190 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 --------- --------- 015 020 031 051 081 101 121 161 201 251 301 351 381 401 402 502 602 702 802

EER Energy efficiency EEER 3.50 3.40 3.30 3.20 High energy efficiency! HE EER = 3,1 CLASS A 3.10 3.00 2.90 2.80 2.70 2.60 2.50 2.40 2.30 2.20 EER = 2,8 CLASS C EER = 2,5 CLASS D 2.10 2.00 015 020 031 051 081 101 121 161 201 251 301 351 381 401 402 502 602 702 802

ESEER Energy efficiency ESEER 5.00 4.90 4.80 4.70 4.60 4.50 4.40 4.30 4.20 4.10 4.00 3.90 3.80 3.70 3.60 3.50 3.40 3.30 3.20 3.10 3.00 2.90 2.80 2.70 2.60 2.50 2.40 2.30 2.20 2.10 2.00 ESEER average = 3,8 ESEER average = 3,1 015 020 031 051 081 101 121 161 201 251 301 351 381 401 402 502 602 702 802

Operating limits TEMPERATURES T amb MAX: : +43 C: may reach +50 C with low water outlet temperatures T amb MIN : -5 with standard step type fan control version for 20 C For T< + 5 C anti-freeze solutions must be used EVAPORATOR WATER TEMPERATURES Tw IN/OUT MIN: -5 /-10 C Tw IN/OUT MAX: +35 /+30 C 43 C -5 /-20 C These values depend on the ambient temperature Advantages Operating limits among the best on the market Standard configuration also for low temperature applications (min. water outlet T down to 10 C) +30 /+35 C -5 /-10 C

Compressors Copeland ZP scroll compressors 2-pole electric motor cooled by the gas drawn into the compressor. Axial and radial compliance for superior reliability and efficiency Direct starting. Suspended on rubber antivibration mounts. Installed on a compartment separated from the condensing one. Crankcase heater as standard Soft starter Soft starter (optional) factory fitted. Available for mod.381-401-702-802 (it will be implemented also on mod. 402-602) Reduces starting current by about -30%

Evaporator Evaporator Tank in carbon steel Finned coil type evaporator with copper tubes and aluminium fins Higher design pressure; Refrigerant flows through the tubes; The water flows through the baffles in contact with the finned surface; Non Ferrous version (mod. 015-351) Tank in AISI304; exchanger coil with copper tubes and fins and brass shoulders/case; No Ferrous fittings and pipes: stainless steel and/or brass and/or plastic; Air bleed valve Water discharge Advantages Low pressure drops on water side Well suited to operate with high flow rates and low ΔT Susceptibility to fouling significantly lower than plate heat exchangers Level sensor

Fans Axial fans (mod. 015 802) Axial fans with die-cast aluminium crescent-shaped blades The motor with external rotor and life lubrication forms a single unit with the fan blades and is protected from overheating by an integral thermal cutout. Protection rating: IP54 from Mod. 031 (IP44 for Mod.015-020) Centrifugal fans - option (mod. 031 161) Double intake fans with the rotor shrink-fitted directly on the electric motor shaft. ON-OFF control with pressure switch on HP side Available head pressure 100 200 Pa IP54 lateral air outlet option no more available

EC high pressure axial fans - option Ziehl ZA plus EC inverter (mod.201 802) They replace the centrifugal fans. Synchronous brushless motor inverter driven Operating range: stepless rotation from 5% to 100% High available head pressure (about 150Pa) 55% = 550W 25% = 250W 20% = 200W EC motor Advantages Higher precision in condensation pressure control Seasonal energy aving -20%. Pays off in few months -20% Seasonal energy saving

Options and configurations

Dual frequency version (mod. 015-161) Dual frequency version Mod. 015-161 Power supply 400V/3ph/50Hz - 460V/3ph/60Hz (necessary to change the supply of the primary circuit of the control circuit transformer) Available only 2 configuration with P3 pump or SP (without pump)

Electronic Expansion Valve (mod. 081-802) Features Option available for mod. 081-802 EEV is a servo-controlled and electro-mechanic device which expands the flow of refrigerant in a variable manner A pressure sensor and a temperature sensor correspond to the pressure fitting for compensation and the sensor bulb in the TEV. Both these sensors are fitted to the evaporator outlet Advantages Quicker response time for changes Stable superheat in the whole range of operation conditions, both for full as well as part load operation. E 2 V

Double pumps option (mod. 201-802) Features Pumps work in stand-by Hydraulic connections with flexible pipes New configuration with INLET/OUTLET manifolds Intercepting and no returns valves Pumps switching automatically (running times equalization). mod. 201 351 mod. 402 802

Antifreezing heaters option Features Electrical heaters wraped around tank & pump If -10 C < T amb. < 0 C heaters and pumps are switched ON by the electronic control. If -20 C < T amb. < -10 C in addition to the anti-freeze heaters, it is necessary to double insulate tanks and pumps (special machine). If outlet water temperature Tw out <+5 C it is necessary to use antifreeze mixtures.

Close temperature control LASER version Features The valve keeps the temperature of the process water at the unit outlet constant and within narrow tolerances (precision ±0.5 C) by injecting hot gas into the evaporator. Availability: mod.015-351 hot gas bypass solenoid valve (mod. 015-051) or electronic expansion valve (081-351) shut-off valves for hot gas bypass (TAEevo031-351) Advantages High precision PID control Control of outlet temperature independent of compressor minimum ON/OFF times

Low ambient temperature version -20 C (mod. 031-802) Features Electronic fans speed control. Electr. panel heater Cranckcase heater Suitable for ambient temperature down to -20 C: For operation without glycol the Antifreeze heaters option must also be specified.

TAEevo TECH: QR CODE

TAEevo TECH: QR CODE

TAEevo TECH vs TAEevo R407C

TAEevo TECH vs TAEevo R407C: refrigerant charge Refrigerant charge [Kg] 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0-11% + environmental friendly 015 020 031 051 081 101 121 161 201 251 301 351 402 502 602 TAEevo TECH TAEevo

High efficiency Air cooled industrial chillers High efficiency version

TAEevo Tech R410A: HE version Features Mod. 031-802 ZP SCROLL COPELAND compressor; Increased condensing surfaces High efficiency axial fans Ziehl ZA plus EC inverter High energy efficiency: EER > 3,1 CLASS A High efficiency

Air cooled industrial heat pumps

High efficiency air-cooled reversible heat pumps Models Versions Main features Erp 2017 ready Energy efficiency class A+ Refrigerant R410A Power supply: 400/3/50 Cooling/Heating capacity: 13 80 kw / 15 90 kw Finned coil evaporators submerged in the storage tank Scroll compressors Axial EC brushless fans (option) IC 208CX electronic controller Single circuit with one or two compressors Electronic thermostatic expansion valve (optional) Phase monitor standard Compressors crankcase heaters standard Data declared according to EN14511:2013: cooling*: evaporator: 12/7 C; ambient temperature35 C

TWEevo TECH Water cooled industrial chiller

TWEevo TECH Water cooled industrial chillers Main features Mod. 031-802 Power supply: 400/3/50 & 460/3/60 UL Refrigerant R410A Cooling capacity 13 230 kw Finned coil evaporators submerged in the storage tank Models Versions Shell&Tube condensers Scroll compressors Unique parametric microprocessors IC208CX. Single circuit with ne or two compressors (mod.031-401) Dual circuit with four compressors (mod.402-802) Electronic thermostatic expansion valve (optional) Phase monitor standard Compressors crankcase heaters standard

Air cooled industrial chiller for high ambient temperature

TAEevo PLUS R134a Standard version for Tamb max +50 C (Twout +15 C); Refrigerant R134a; Mod. 020 802 ; Cooling capacity 3,8 90kW; Dynamic water set point according to the outside temperature Electrical panel ventilation; Pumps suitable for +50 C (oversized motor);

Working limits AMBIENT TEMPERATURE Minimum ambient temperature = 0 C (1) (STD version) Maximum ambient temperature = 50 C (Tw in/out = 20 C/15 C) (1) Tamb min = 0 C. The value refers to the machine full of ON / OFF fan. For units with electronic control of the fans consider -5 C. WATER TEMPERATURE Outlet water temperature MIN = 0 C (with glycol) Inlet water temperature MAX = 35 C;

Air cooled industrial chiller for low water temperature

TAEevo LWT Minimum outlet water temperature -20 C Mod. available 081 802; Cooling capacity 7 70kW Scroll compressors; Compressor crankcase heater; Check valves for compressors in tandem; Solenoid valve on liquid line; Double insulation on hydraulic tank; Pumps with oversized motor suitable for high percentages of glycol; Valves on pump suction and discharge;

TAEevo LWT - Working limits AMBIENT TEMPERATURE Minimum ambient temperature = 5 C (1) (STD version) Maximum ambient temperature = 45 C (Tw in/out = -10 C/-15 C). (1) The value refers to the machine with ON/OFF fans control. For units with electronic control Tamb min -10 C. WATER TEMPERATURE Minimum outlet water temperature = -20 C Maximum inlet water temperature = 0 C (1) (1) transients during start-up with higher temperatures are allowed.