more than M A N U FA C T U R I N G F R E E Z E R S U LT

Similar documents
EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

EVOSAFE TM -SERIES ULTRA-LOW TEMPERATURE FREEZERS

MICRO CLIMA-SERIES TM (COOLED) INCUBATORS AND WALLS

MICRO CLIMA-SERIES TM PREMIUM ICH INSECT CHAMBER

Ultra-Low. Temperature. Freezers. Advantage Series. Basic Series. Microprocessor Control. Solid-State Electronic Control

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

TwinGuard ULTRA LOW TEMPERATURE FREEZERS

NEW! Thermo Scientific Revco PLUS -86 C Freezers. Protecting Your Life s Work

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

Protect your research

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

ULTRA.GUARD ultra low temperature freezer

DOUBLE DOOR FREEZER.

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Compact Ultra Low Temperature Chamber

Ultra low temperature freezers. -40 C and -86 C. Green Line

-86 C ULTRA-LOW TEMPERATURE FREEZERS SERIES

Tabletop 2340 EA-D Class S Autoclave 19 Litres

TwinGuard ULTRA LOW TEMPERATURE FREEZERS SERIES

Protection, safety, reliability. And more.

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

86 C freezers. New Benchmark. New Brunswick sets the standard for extraordinary freezer quality, support, and energy savings

Medical Refrigerators

PR / MP I Laboratory / Medicine

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Refrigerated Incubator Model and Operating Instructions

SNIJDERS LABS EXPERIENCED INNOVATORS. MICRO CLIMA SERIES ARABIDOPSIS CHAMBER, type MCA1600. MCA1600 Pagina 1 van 11 STEK ISO9001:2008 CERTIFIED

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

REFRIGERATOR M E D I C A L.

Refrigerated Incubators / Environmental Testing Chambers

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

-86 Ultra Low Temperature Freezer

DATAssure. Laboratory wireless alarm & monitoring system

Chromatographic Air circulated Refrigerator, two-door TC 603

Altitude Chambers.

CLIMATRON GROWTH CABINETS

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

Biomedical Freezer 37 38

Dew point set DS 400

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Benchtop & Compact Test Chambers

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range


-1050C FREEZER NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

Ultra Low Freezers. Blood Management Solutions. B Medical Systems U Range

Multi-Lab REFRIGERATORS Frigidere medicale

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

Refrigerators & ULT Freezers

Octalarm-T: the latest in future-proof industrial alarm diallers

CSF. Contact Shock Freezers. Blood Management Solutions. B Medical Systems CSF Range

laboratory & sterilization technology

NC SERIES. Horizontal Steam Sterilizers

KEY CONSIDERATIONS WHEN PURCHASING AN ULTRA-LOW TEMPERATURE FREEZER

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

MEDICAL REFRIGERATORS

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Heated and Refrigerated Incubators

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Cold chain monitoring technologies. Facility monitoring

Laboratory refrigerators and freezers

NEW! Thermo Scientific Revco PLUS Ultra-Low Temperature Upright Freezers. Maximizing Critical Sample Protection and Storage

ULTRA LOW TEMPERATURE FREEZERS -40 C -86 C HPL LINE (High Performance Line)

Laboratory Freezers. Medical Refrigeration. B Medical Systems F Range

ULTRA LOW TEMPERATURE FREEZER. User Manual

Laboratory Refrigerator/Deep Freezer TC 802

Benefit Cabinets. Performance. Efficiency

Benefit Cabinets. Performance. Efficiency

LABorAtory refrigerators

Chromatographic Air circulated Refrigerator, two-door TC 603

Walk in Freezer. Comfortable work environment

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Thermo Scientific HERAfreeze Top and Basic Freezers Solutions for safe sample storage

laboratory & sterilization technology

Setting the Benchmark

Ice Lined Refrigerator User Operation & Maintenance manual

Advance Blood Storage system from Meditech

FREE ZERS LABORATORY FREEZERS -30 O C. i.series TM Horizon Series TM

MEDICAL CHILLER SYSTEMS

RACK MONITORING SYSTEM - RAMOS Ultra

Ultra-Low Temperature Chest Freezers

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Undercounter Refrigerator Operation Manual i.series and Horizon Series

REAL TIME LABORATORY MONITORING SYSTEM

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

REFRIGERATORS AND FREEZERS. laboratory chromatography ultra low temp pharmacy vaccine hazardous flammable undercounter performance qualified

THX-DL Data Logger USER & INSTALLATION MANUAL V

BIOMEDICAL REFRIGERATORS

SAVING LIVES THROUGH RELIABLE AND INNOVATIVE TECHNOLOGY. Medical Refrigeration

Transcription:

EvoSafe-series more than C E L E B R AT I N G M A N U FA C T U R I N G U LT years F R E E Z E R S Evolutionary Safe Ultra-Low Temperature freezers -86 0 C A full range of Ultra-Low Temperature freezers, in capacities from 120 up to and incl. 720 ltr. designed to protect your samples and to save energy at the same time.

Snijders Scientific has been manufacturing Ultra-Low Temperature (ULT) freezers for over 30 years. The company is ISO-9001 certified for Development, Manufacturing, Sales and Service. Snijders Scientific operates worldwide by co-operating with factory certified and trained distributors for installation and service of the freezers. By adapting to customer requirements, focusing on technology and functionality, we are able to strengthen our market position and quality. Isolation technology The EvoSafe-series are fitted by an unique insulation method installed between the interior and exterior metal profiles. A combination of PU blocks with twocomponent foam is used (the so-called foam in place insulation). This system ensures that all the cooling is transferred to the interior of the freezer and hence improves considerably the insulation value over vacuum panel technology (see the comparison in the below pull-up graph). Examples of temperature rise during power failure Pull-up example from a freezer with vacuum insulation Pull-up EvoSafe TM VF720-86 Temperature ( C) 0-10 -20-30 -40-50 -60-70 -80-90 -100 0 1 2 3 4 5 6 7 8 9 Time (hour) Temperature ( C) 0-10 -20-30 -40-50 -60-70 -80-90 -100 0 1 2 3 4 5 6 7 8 9 10 11 12 13 Time (hour) Vacuum insulation or PU The internal and external dimensions of the EvoSafe-series TM are tailored to the European metric system (mm, cm and meters) to take European inventory systems, in contrast to other Asian and American producers. This allows a greater capacity of boxes to be stored while using the conventional polyurethane insulation while keeping the external dimensions to a minimum. Ask for EvoSafe-series TM datasheets for more information on, among others, the exact numbers of boxes and dimensions.

Conclusion With any brand using vacuum insulation the Pull down period is comparable to the EvoSafe TM freezers. The difference in the Pull up time, however, is clearly visible. A freezer with vacuum insulation during a power failure reaches -10 C (from -86 C), within 9 hours. With the PU foam in place insulation of the EvoSafe-series it takes 12 hours before the freezer reaches -10 C (from -86 C). State of the Art - Ultra-Low Temperature cooling The EvoSafe-series is the result of 30 years of experience with Cascade cooling technology. They are designed for high performance, sustainability, energy efficiency and low noise output, due partly to the selection of the Tecumseh compressor silent range. The cooling system layout has been improved to allow all the heat generated in the engine room to be discharged directly to the rear and out of the compartment. The EvoSafe cooling system has been filled with non-flammable, environment friendly CFC and HCFC free refrigerant. The ULT freezer performance consistency is greatly increased due to using an uniquely designed PC based coolant dosing system, which can fill with an accuracy of 0.01 gram. The freezers are then tested 3x for leakages within our own testing facility.

Energy consumption The graph below gives a representation of the energy consumption in Watt, per box, per hour and is based on the EvoSafe TM model VF720-86 (capacity: 528 pcs. 2 boxes). For comparison the graph shows a freezer with a similar capacity selected from the Asian and American markets. 3,5 3 2,5 2 1,5 1 0,5 0 Energy consumption in Watt per 2 box per hour, VF720-86 EvoSafe-series Asian brand American brand Water cooling option Our ULT freezer can be installed with a water-cooled condenser and when installed they will use between 5 to 10% less energy. This system rejects less heat to atmosphere and therefore there are significant cost savings to be made by using less air-conditioning to cool the ambient in the space where the freezers are housed. Capacity Maximisation of capacity, calculated in litres, was achieved by matching the internal dimensions to the standard box and racking system used throughout Europe. This results in more boxes per freezer, a lower volume in litres and therefore optimum sample storage capacity. Brand A 725 litre freezer with 3 inner doors (based on 2 boxes). EvoSafe-series 720 litre freezer (VF720-86) with 2 inner doors (based on 2 boxes). Total capacity 504 pcs. 2 boxes. Racks required : 18 pcs. Total capacity 528 pcs. 2 boxes. Racks required: 12 pcs. single or 6 pcs. double.

Webbased controller with ifreeze technology The controller is the brain of the freezer, which uses the most advanced measurement and control techniques. Developed specifically for the EvoSafe-Series ; to give maximum security and reliability, including modern multimedia and communication technologies. Status LED s LED Cool=Cooling active LED Backup=CO2 active Setpoint key to read/adjust setpoint. Prg key with indication LED for entering the program mode. Display 4-digit 7-segments for temperature/setpoint and parameters readout. UP and DOWN keys to adjust setpoint and parameters. Mute/Batt. key for reset alarm and battery status. Code key with indication LED for entering authorised access. Power on/off key to switch the controller on/off (authorised access). Temp. low LED warning temperature too low. Temp. high LED warning temperature too high. Low Batt. LED warning battery is low. Communication with the freezer There are three different ways to communicate with the freezer as shown below in the scheme diagrams. 1. Through USB-port The temperature is logged and displayed graphically. The USB-port is located behind the removable rear condenser plate. After installing the Snijders ifreeze log-viewer software, the chart can easily and quickly be read on any Windows PC. The chart can also be viewed and stored by a direct connection to a PC or laptop. Scheme 1 Standalone Freezer USB-stick USB-stick Laptop

2. Via a local network If a local network (Ethernet) is available a user can view the status of the freezer through the web page Freezer Statistics. For example: the actual temperature, set point, ambient temperature, door open or closed and/or whether there has been an alarm. Scheme 2 Ethernet/intranet Freezer-1 Local PC Ethernet Freezer-2 Ethernet Ethernet Intranet 3. Via Internet To expand communication capability it is possible to access the freezer(s) through any internet connection. This requires a right to be called up to enter the local network via internet. Scheme 3 Ethernet/Intranet to Ethernet/Intranet Freezer-1 Server PC Ethernet Freezer-2 Ethernet Intranet Ethernet www.snijders-scientific.com PC/Laptop

ifreeze logview By one of the three aforementioned forms of communication, the temperature log of the freezer can be retrieved. Through the 512 MB memory the freezer logs every 20 minutes the most critical parameters. The maximum storage is 6 months. Below is an example of a temperature-time log graph. Legend graph: Adjust temperature [ C], Condensor temperature [ C], Set point [ C], Battery voltage [Vdc] AC In the status bar below the chart is stated when these functions have been active. Freezer Statistics By using the standard webinterface including a unique TCP/ IP address, it s possible to approach one or more freezers. In this way it will be possible to look at a number of important parameters, such as among others: set temperature and actual temperature if the fan is running if the door is closed if there is an alarm or has been an alarm

Safety Monitoring 24 hours a day - 7 days a week Alarms will be notified, acoustically and visually, through a code in the display and via the potential free contact. Under normal use and with preventive maintenance the EvoSafe freezers have a lifetime of at least 10 years. European quality All used electronic and cooling components are sourced from reputable European brands. This selection process has a positive effect on the lifetime of the freezers. For example: Tecumseh compressors, EBM Pabst ventilators, Siemens relays, Jumo sensors, DuPont refrigerant and Danfoss components. Our suppliers comply with the latest European directives in the field of energy, environment and safety. No low-cost components are used, thereby ensuring quality and sustainability remains. Alarm functions In the event of a failure or warning, the freezers are equipped with various alarms. Each alarm has an unique code that is seen on the display of the controller. There is a mute button for audible alarm. Available and selectable alarm functions: minimum or maximum temperature exceeded door alarm filter alarm damaged sensor (the sensor in both the freezer and the condensor sensor) battery voltage too low battery empty voltage deviation ambient temperature too high condenser fan failure. The ways in which the freezer gives an alarm: acoustically via a buzzer visually in the display by a code via an e-mail via an SMS text message via the potential free contact to a BMS (Building Monitoring System).

Details High quality stainless steel interior Capillary CO2 emergency cooling system Flexible interior for each type of rack Stainless steel platforms, removable and height adjustable Vacuum release Insulated stainless steel inner doors Receiver lock One movement handle with cylinder lock Door heating Internal door closure Door seal Machine room Door alarm switch USB port located behind the removable rear condenser plate Condenser + filter Web based controller with ifreeze technology 4 castors; the front two with brakes

Rear freezer CO2 fuse SMS Novo alarm (optional) Potential free contact CO2 connection Power cable 2 Spacers Ethernet connection Flexible divisions All upright freezers are fitted with in height adjustable platforms allowing virtually any format and any type of rack to be used. The example below of the VF720-86 freezer with 2 different divisions (2 and 4 compartments). Division 1 Division 2 Platform 1 Platform Platform 2 Platform 3 2 compartments/10 racks. 4 compartments/20 racks.

Cryotheque - Biobank In addition to the manufacturing and delivery of ULT freezers Snijders also offers the facility to store the valuable samples of customers in either their own ULT freezers or ones supplied by us in our fully conditioned storage facility. This facility includes temperature controlled storage rooms, fitted with all necessary safety devices for 24 hours a day, 7 days a week storage of valuable client samples. For example: burglar and fire alarm, temperature logging and alarms, emergency power, visitor registration and backup freezers if required. This offers advantages such as: maximum security during the storage of your samples freezers no longer located at the customers site, hence saving space, no heat removal requirements, no excess noise, energy saving and no maintenance or malfunctions spreading costs opportunity for third party clinical trials risk management of the unique collection of patient DNA or irreplaceable material. Service and warranty Contact your local distributor who will guarantee quality and service (if necessary check our website for distributor details).

Sharing technology Visit our website www.snijders-scientific.com For more information about the ULT-freezers and to view our entire product range, including: various climate chambers for plant and insect research; with temperature, light and humidity control. Microclima Plant Growth Chamber The controlled environment for reproducible results Cooled incubators (cooled) incubators and incubator walls designed for general microbiological research of among others food and water and medical laboratories. snijders scientific b.v. www.snijders-scientific.com Office and Production: Laurent Janssensstraat 105 5048 AR Tilburg The Netherlands Showroom and Testfacility: Gebroeders Salastraat 40 5048 AL Tilburg The Netherlands Tel.: (+31)13-4633600 Fax (+31)13-4638635 info@snijders-tilburg.nl - Ask us for the datasheet of the freezer type, incl. accessories, you re interested in. U1EN2000-2011 Specifications subject to changes.