Manual. smrt Crewguard. Providers of the leading Mobilarm and Sea Marshall brands of Man Overboard solutions

Similar documents
Lone Worker Duress Security Hazard Zone Remote Area Health Care DURESS & SAFETY TECHNOLOGIES I N T E R N A T I O N A L

Alarm Tone Generator Model AG17

installation & operation manual

External Wireless Sounder

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Protégé Eclipse LED Keypad User Manual PRT-KLES

GSM 3G AUTO DIALLER PLUS

External Wireless Sounder


Installation and user guide

Wireless Alarm system s manual

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

2G & 3G GSM Door Contact Alarm

Your Lifeline Vi+ home unit. Your MyAmie pendant

3G GSM AUTO DIALER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

Installation and ZONES: Operation Manual. Model: ON STI-34108

Installation and Programming manual INSTALLATION MANUAL E PROGRAMMING INSTALLAZIONE PROGRAMMAZIONE

GSM 3G AUTO DIALLER. Remote monitoring & Control using your mobile phone. MODEL NUMBER 3GAD1

PERMACONN PM1030 Includes DI300. Installation Manual

SCORPION Z16040C, Z8040C and Z5120C

Elderly Care Alarm System

communicall connect solutions sheet What is Communicall Connect? Who is it for? What does it consist of?

NEVER ACTIVATE THE STROBE WITH THE PCB OUT OF ITS PROTECTIVE CASE. EXTREME CARE IS ADVISED TO REMOVE THE RISK OF ELECTRIC SHOCK.

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

2G & 3G GSM Wireless Beam Alarm

2G & 3G GSM Portable PIR Alarm

Any additional devices linked to the system ET08 (computer, sensors, relays etc.) must be approved by LST EN standard.

LEAKSTOPPER RANGE Multizone water leak detection systems

DESCRIPTION INSTALLATION

SCHMIDT LED Measured Value Display MD Instructions for Use

Remote switching machines with a SMS text from your mobile phone! Remote Monitoring your assets in the worldwide by your mobile Phone!

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

ALARM DEVICES FOR MAN OVER BOARD AND RESCUE ACTIONS (DAHMAS)

LifeTag System Operation Guide

Model PT-05 Model PT-06

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

Fire / CO Alarm Interface

Preface. Thank you for purchasing our GSM Security Alarm System ( The System )! The System will keep your home and property safe around the clock.

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

Supervised Security System Owner s Manual

Tunstall Vi+ User Guide

Instruction manual. W440 AIS Sart Sniffer

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

USER MANUAL Mobeye ThermoGuard CM2200

Digital Electronic Thermostat With RF

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

MK9 series CarePhone. Installers Mauual

Learning Thermostat Installation Guide. Installation step by step

Lifeline 400 user guide q6 18/2/04 10:56 am Page 2. Lifeline 400. installation and user guide. Part Number D B


Digital Electronic Thermostat With RF

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

Premier Hazard STC Instructions

Wolf Guard Touch Keypad GSM Wireless alarm system User s Manual

ir-range 8G /03.15 Changes reserved.

LED LAMP: To turn on the LED Lamp, press the LIGHT BUTTON located on the front. Press again to turn off.

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

VPS3 Installation Manual

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

Supervised Security System Owner's Guide

L900 series USER MANUAL

Electrical rating 230V AC, 50Hz 100mA max per (maximum 35mA for originating unit with 16 Devices interconnected).

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

Memcom Emergency Telephone

INSTRUCTION MANUAL C-4010 SCAN HERE

USER & INSTALLATION GUIDE

KFP-CF Series Operation Manual

USER GUIDE. DRENA 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS - WASTE WATER -

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

SMART SWITCH TECHNOLOGIES. SmartSwitch Yacht-Guard Model SMS-8 Vessel System Monitor Installation Manual

MEDI-MINDER USER MANUAL

Installation and user manual for the BiWire / Conventional Repeater Panel

AZSG10000/AZSG10005/AZSG10010 ABUS Wired Outdoor Siren

IRIS Touch 200 Range Dialler Installation Manual. Version 1.4

English. Doro CareIP Mobile. User Guide

Version 1.03 January-2002 USER S MANUAL

DYGIZONE GJD910 Lighting Controller & Enunciator

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Contents. Glossary

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

1. Introduction. 2. Product overview

Deaf & Hearing Impaired RadioLINK Alarm System

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

AFA 500 FUME HOOD ALARMS

Basic Installation Manual

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

Call stations and extensions

MOBILE CALL GSM Alarm System User s Manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

status AW1 Plus WiFi Alarm System User Manual

Transcription:

Manual smrt Crewguard Providers of the leading Mobilarm and Sea Marshall brands of Man Overboard solutions

Contents PAGE No. Description 3 Declaration of Conformity 4 Technical Data 5 Overview 6 Mounting the display 7 Display Key functions 8-9 Lone Worker System 10 Warranty Information 2

Declaration of Conformity Name of Manufacturer/Eu importer Declares that products: Marine Rescue Technologies Ltd. Marshall House, Zarya Court, Grovehill Road, Beverley, HU17 0JG United Kingdom sales@mrtsos.com www.mrtsos.com smrt Crewguard CG-121 MkII Conforms to the EMC Directive 2004/108/EC and the R&TTE Directive 1999/5/EC as attested by conformity with the following harmonized standards with the following harmonized standards: ETSI EN 301 489-I VI.I.I (2002-08) Low Voltage Directive 73/23/EEC as attested by conformity with the following harmonized standard: EN60950-1:2001 Information technology equipment Safety part 1: General requirements. 3

1.0 Technical Data smrt Crewguard CG-121 Control Box Dimensions 170x120x60mm Aluminium Box (excluding antenna & connectors) Weight 1400gms Mounting Options Surface 200mm x 130mm (Opt 1) Bracket 198mm long x 60mm wide (Opt 2) weight 450gms Temperature range -20 C + 60 C Waterproofing IP68 Sensitivity 0.5 uv at antenna input Frequencies 121.5 MHz, 121.65 MHz (Test 1), 121.775 (Test 2) Criteria of ELT/PLB recognition Audible AM-modulated howling, downward LF-range within 300Hz 1600Hz LF-range 700 Hz minimum Time of repetition: 250ms.500ms DELTA lf/25ms: -10Hz -250Hz Audio exit max. 8Vss (speaker > 8 Ohm) Relay contact Floating, carrying capacity max. 0.5 A/10W Current Drain Standby = 80mA / If alarm + ext. speaker (8 Ohm) = 400mA Operating Voltage 12V DC (+ - 20%) Airband Fixed Antenna(optional) Type: Fixed, Freq Range 120/300MHz. Impedence Impedence: 50 Ω Gain:3.4dBi (120MHz), 5.5dBi (300 MHz). VSWR: <1.5. Rated Wind Velocity: 60m/sec. Length: 1.7m. Max Dia: Approx 34cm. Weight: 1kg. Type: 5/8 wave(120mhz) 2x5/8 wave(800mhz). Connector: M(M-J) Highgain Whip Antenna(optional) Type: Dipole ½ with loaded radial. Freq Range:118-137MHz. Impedence: 50 Ω Radiation (HPlane):360 Omnidirectional. Gain: 2.15dbi.Max Power: 50Watts. Feed System: direct / Centre. Cable Length/Type: 5m, RG58 C/U. Connector: FME-female. Length: 760mm. Weight: 330gr. Radial Length: 165mm. Mounting Hole:14mm. L Mounting Bracket: 98mm x 63mm 4

PRODUCT NAME - CREWGUARD CG-121 MKII man overboard monitor alarm 2.0 Overview The Crewguard is a simple low cost monitor/alarm unit which continuously monitors its local area for an SOS signal from a Sea Marshall beacon. It will raise the alarm within a few seconds of receiving an SOS signal by automatically sounding an external alarm and flashing all the LEDs on its display. 5

3.0 Mounting of the Crewguard box 3.1 The Bridge Box can be flush mounted by cutting a hole in the mounting surface. The unit can then be mounted using the four M4 nuts and bolts provided or used with the supplied trunnion mount adjustable bracket. 3.2 In either case the display should be mounted on a smooth and stable surface. The back of this unit has to be accessible for power supply connectors. Ensure that there are no other vulnerable elements within the mounting surface (e.g. electric cables, gas pipes or water pipes). 3.3 When installing ensure you leave space for the supplied antenna or if using an external antenna, the cable connection. An externally mounted Hi-gain antenna or whip antenna can also be fitted (sold separately) to increase detection range. External antenna with mounting brackets. Comes with 5m cable and plugs, fitting, mounting bracke.significantly increases monitoring area of MOB system and provides coverage in radio blind spots. 4.0 Testing the system STEP 1 Ensure the system has been correctly installed. STEP 2 Switch the Crewguard control box on, by pressing POWER and then press TONE DETECT. STEP 3 Make sure the PLB is switched off (side switch in up position) then press and hold the round activation button, your PLB will transmit a low powered signal on the live distress frequency of 121.5MHz to a range of approx 30m to 50m. NOTE Check you are not within range of another receiver. STEP 4 When the Crewguard alarms the LEDs will flash ON and OFF and the siren will sound. STEP 5 Repeat the test at different points around your vessel and away from your vessel until you and your crew are satisfied how the system operates. 6

5.0 Crewguard Control panel functions 5.1 POWER Turns unit on and off. 5.2 TONE DETECT Enable/disable In this mode the Crewguard only identifies and responds to a signal from a Sea Marshall SOS Alerting Unit (PLB). When an SOS signal is received the unit activates both its internal and external alarm or other external devices connected to the unit. 5.3 FREQUENCY - Set to 121.5MHz when the power ON/OFF button and or reset button is pressed. 5.4 TEST - Select test frequency as required (121.65 or 121.775MHz). NOTE: the unit will automatically default back to 121.5MHz after 20 minutes. (Your unit if required may be programmed to default to 121.65MHz). 5.5 RESET Press this button to cancel the external alarm and reset the unit 5.6 VOLUME HIGH / LOW NOTE these buttons can be used to control the brightness of the display LEDS. To do this press and release the POWER button so that all LEDs are lit. Use the VOLUME buttons to adjust the LED brightness. 5.7 RRSI Received signal indicator. (Red LED in middle of SOS logo) 5.8 RSSI Received Signal Strength Indicator 4 Green LEDs 5.9 Plug wiring Black 1 Black 2 Black 3 Green / Yellow Relay Contacts 0V DC Negative 12V DC Positive Relay Contacts If for any reason you are unable to affect your rescue contact the Coast Guard and tell them you have a man in the water wearing a 121.5MHz PLB. 7

PRODUCT NAME CREWGUARD LONE WORKER MONITORING SYSTEM (For declaration of conformity refer to individual component products in this manual) 6.0 OVERVIEW The Sea Marshall Crewguard lone worker monitoring system provides 24/7 MOB health and safety cover for organisations which have employees spread out over very large areas, with individuals often working alone either on or next to water. This system has been used at water reclamation plants, refuelling jetties and fish farms both at sea and in shore. 6.1 UNMANNED AREA CREWGUARD lone worker man overboard MONITORING system This system is made up of the following components 1 Cabinet mounted Crewguard CG-121 MKII monitor alarm (with auto-dialler depending on requirement) 1 High gain external antenna with 20m cable, (plus fixtures and fittings). (External siren with strobe light if required). MOB alerting units (PLBs) as required (sold separately) with optional lifejackets This system provides automatic 24/7 man overboard cover for all types of jetties and large areas of water, it is an automated version of the Crewguard system which uses a telephone auto-dialler (either land-line based or GSM) to notify key persons if there is a MOB incident. (For further information refer to Alerting Unit handbook) 6.2 Monitor on jetty or control room on platform The telephone auto-dialler MOB monitor/alarm system. Several telephone numbers can be programmed into the auto-speech dialler. A personalised voice message is recorded onto the auto-dialler by the user; for example May Day, May Day, May Day, Man Overboard at position 1 (Position 1 for a system with a single monitor in one location only, position 2 for a system with 2 monitors in different geographic locations...ongoing as required for systems which have several monitors covering a large geographical area). In the event of a man overboard incident the SOS signal from the Alerting Unit worn by the man overboard will trigger the Crewguard MOB monitor alarm which in turn activates the telephone auto-dialler - automatically calling the first member of staff from the pre-programmed list of telephone numbers if they fail to answer it will continue to dial every number on the list until someone acknowledges the phone call and takes appropriate action. A fast rescue craft fitted with a SARfinder locator unit could then be launched to track the SOS signal being transmitted by the man over board s PLB. There may be differences in the type of dialler fitted into the cabinet mounted monitoring system, please refer to the manufacturer s instruction manual supplied with your system. Dimensions Cabinet Approx. Height = 40cm, Depth = 15cm, Width = 30cm Weight Approx. 7.5kg Temperature Range -20 C + 60 C Waterproofing IP-65 Power Supply basic system 12V Cabinet mounted option comes supplied with mains 12V adapter and universal plug fittings. 8

6.3 The MOB alarm on the Crewguard monitor will sound & the warning lights will flash on and off. 6.4 The MOB alarm will activate accompanied by a telephone call playing your pre-recorded SOS, May Day, May Day, May Day Man Overboard at position 1 telephone message. 6.5 Press the RESET button to cancel the alarm or cancel remotely using phone (full instructions on how to cancel alarm can be found in supplied auto-dialler manual). 6.6 To test for the best coverage use a test beacon at regular distances away from the receiving antenna until the alarm no longer activates, this will indicate the maximum range of the system. To find out if you have any radio blind spots move around your area and repeat the above test process. To overcome radio blind spots increase the height of the external antenna or reposition the antenna. 9

Warranty Your unit is covered by a standard 1 year parts and labour warranty. Marine Rescue Technologies Ltd (MRT) warrants to the purchaser that the products conform to manufacturers specifications and that the products are free of defects on materials and workmanship for a period of one year from the date delivered to the customer/end user. In the event of a defect, due to faulty material, design or construction, the customer will return to MRT at the business address where we, or the manufacturer will undertake, at our choice, a repair or replacement. Warranty covers all parts, materials and labour, provided that the product is returned to our works. Exclusions: damage caused by other than normal use and lack of general care and attention or incorrect sealing of the unit carried out in accordance with this instruction manual. MRT Ltd. does not accept any responsibility or any claim for direct or indirect consequences of defects of the equipment, either during the guarantee period or at a later stage. Repairs MRT Ltd. offers a full and comprehensive service and repair facility with return normally within 14 days upon receipt of customer s authorisation. Disclaimer The Sea Marshall products are an aid to recovery only, it is the responsibility of the user/operator to ensure they are fully conversant with the operation of the equipment and the equipment is kept in full working order at all times combined with functionality and damage checks before and after each use. MRT Ltd. does not accept liability for loss of life or injury caused during any accident during which the equipment is being used, howsoever it arises. Sea Marshall Alerting Units/MSLDs are an Aid to rescue only, they do not guarantee your safety. The Sea Marshall MSLDs will dramatically increase the chances of detection and location of a Man Over Board. Personal safety remains at all times the sole responsibility of the individual. It is the responsibility of the individual to inform their local Coast Guard, their senior personnel/crew members and or family of their intended location/destination and estimated duration of journey. It is also the responsibility of the individual to notify these people of the type of safety equipment they will be carrying. In the case of accidental activation the user should deactivate the unit and notify the appropriate SAR Authority. 10

Notes 11

We take the SEARCH out of Search and Rescue Marine Rescue Technologies Ltd Marshall House Zarya Court Grovehill Road Beverley East Yorkshire United Kingdom HU17 OJG UK Tel: +44 (0)1482 679300 : Fax:+44 (0)1482 679145 Web: www.mrtsos.com :Email: sales@mrtsos.com 12