Air to Water SPLIT TYPE & MONOBLOCK TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING. High Power model Comfort model Compact model

Similar documents
Hot water supply. Indoor unit. Domestic hot water tank. Take thermal energy from atmosphere. Outdoor unit

FUTURE SOLUTION OF DOMESTIC HEATING. Air to Water

PRODUCT LINEUP AIR TO WATER. For RESIDENTIAL. Room Heating & Cooling

PRODUCT LINEUP AIR TO WATER For RESIDENTIAL

AIR TO WATER. Complete Solution meets various needs

DESIGN & TECHNICAL MANUAL

AIR TO WATER. Complete Solution meets various needs

Innovative Solution of Domestic Heating. Split type. Split DHW Integrated type. Monobloc type

DESIGN & TECHNICAL MANUAL

Air to water Heat Pump System

Air to water Heat Pump System

Do you want a versatile solution

DESIGN & TECHNICAL MANUAL

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

Hi-spec Design model. Photo : LT series

PAC BT LOW TEMPERATURE HEAT PUMP

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

DESIGN & TECHNICAL MANUAL

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

NATURAL HEATING MACHINE

Advance Split

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

AQUAHEAT ADVANCE SPLIT

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Operation manual. Daikin Altherma Low temperature split EHBH04CBV EHBH08CBV EHBH11CBV EHBH16CBV

Tel: Heronhill - For all your Toshiba heating and cooling requirements Air to water Heat Pump System

HT V2 HT Split

ALFÉA EXCELLIA DUO. more. less AIR TO WATER HEAT PUMP

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

WHY A MHI HEAT PUMP?

Products catalogue THERMODYNAMIC SOLUTIONS FOR EFFICIENCY CHALLENGES

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

LG Electronics AE Company, Commercial Air Conditioning

LG Electronics AE Company, Commercial Air Conditioning

The iqe Boiler Range. Combination and System T Boilers.

PACKAGED TYPE. Water heat exchanger is built in the outdoor units. OPTIONAL PARTS LIST. Step Interface 3) Flow Temperature Controller 3)

Tower Green HE Hybrid

Eco Compact Series GAS HEAT PUMP

DAISHIBA Heating & Refrigeration Equipment Co., Ltd

THE HEAT PUMP CHOICE OF PROFESSIONALS

Air Conditioning Product Brochure 2015/2016. Classic Series Hi-Wall Split Systems. Everyday Cool

AIR SOURCE HEAT PUMPS DUAL CLIMA

NIBE SPLIT ACVM 270 Air/water heat pump

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Operation manual. Daikin Altherma ground source heat pump EGSQH10S18AA9W. Operation manual Daikin Altherma ground source heat pump.

50A KP 70A KP 90A KP 120A KP 150A KP 210A

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

Solar controllers Energy under control

Product Line Introduction. Karl Zhang Technical support engineer

S-Therm Air to Water Heat Pumps

Sweden s leading air source heat pump

Monobloc. Distributed by. Copyright 2018 LG Electronics. All rights reserved.

Split Type System. Air to Water Heat Pump

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

Residential Heating Boilers

Natural geothermal energy

Product Brochure 2018 NEW. Flexis. High-Wall Split Systems

Heat pump air/water split single service 3 phase

EVI + INVERTER MODELS A Q U A P U R A

PROMATIC WDC Heating controllers Energy under control

w Outdoor Unit w Hydro Indoor Unit w Hot Water Tank *** Projected Availability Q ***

High temperature air-to-water heat pumps

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

EVI Scroll Air To Water Heat Pumps

Air Conditioners. Summer

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Air-to-water Heat Pump Monobloc Versati

SWIMMING POOL HEAT PUMPS

Air to Water Heat Pump Utilising Natural Refrigerant C02

DESIGN & TECHNICAL MANUAL

NRP MULTIPURPOSE HEAT PUMPS 2 AND 4-PIPE SYSTEMS PLUS PRODUCTION OF DOMESTIC HOT WATER

Heat pump air/water split single service

Water Chiller Climate Control from. Integrated FREE Hot Water Heating

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

VRV The total solution. Integrated Climate Control

DAIKIN Modular Inverter Air Cooled Chiller

Field settings table [6.8.2] =... ID66F2. Applicable units *BLQ05CAV3 *DLQ05CAV3 *BLQ07CAV3 *DLQ07CAV3. Notes (*1) *B* (*2) *D* 1/8

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

ASTRALPOOL HEAT PUMP CATALOGUE

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

HEAT PUMPS FOR HEATING AIR-TO-WATER

ECOFOREST GEOTERMIA. ecogeo. Ground/Air Source Heat Pumps.

Product Brochure Smart Power. Low Profile Ducted

EXPLORER HEAT PUMP WATER HEATER. A+ in READY Smart heat pump

AIR CONDITIONERS LINE-UP

Air Conditioner CONTENTS

Domestic Hot Water Application manual

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

Transcription:

Air to Water INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE & MONOBLOCK TYPE Compact model

is an Economical and Clean hot water heating system by Heat Pump ROOM HEATING HOT WATER is an efficient hot water heating system which uses heat pump technology nurtured over many years by Fujitsu General to produce domestic hot water by using the unlimited aero thermal heat source. A wide range of hot water heating systems, from floor heating to radiator heating, hot water supply, and swimming pool, is available to meet living needs. WHAT S A HEAT PUMP? Absorbing the free energy from atmosphere. Heat pump system requires only 1 of electricity to generate 3 to 5 thermal energy. 1 h electricity 3 to 5 h of heat Comfort heating 2 to 4 h Ambient air Heat pump system LESS CO2 EMISSIONS This environmentally-friendly system substantially reduces CO2 emissions compared to conventional kerosene, gas, and other fuel combustion heating systems. Average annual CO2 emissions Direct electric heating Fuel boiler Gas condensing boiler 0 50 100% *Calculations based on data provided by European Program-01` for EU27 Fuel boiler efficiency: 89%, Gas boiler efficiency: 93% FLOOR HEATING 2

Complete Solution meets various needs Domestic hot water Domestic hot water tank Hot water supply Swimming pool Take thermal energy from atmosphere Floor heating outline (Split type) Ambient air Water heat exchanger improves heating efficiency Wide Comfort by Refrigerant The clean energy produced by reliably delivers comfort to diverse spaces in the home up to the living room, bedrooms, bath and swimming pool. Evaporator Compressor Hot water Pump Heating cycle Advantages of LOW RUNNING COST Running cost is low and economical by high efficiency heat pump technology. Average annual running cost Direct electric heating Fuel boiler Gas condensing boiler 0 00 4000 *The values of above graph are calculated in Europe and the graph is illustrative only. The values may vary depending on installation, location, and operating conditions. CLEAN AND HEALTHY Since burners are unnecessary, NOx and other harmful substances and foul odors are not generated. LOW NOISE Inverter control realizes quiet operation friendly to the usage environment. LONG LIFE AND EASY MAINTENANCE There is no accumulation of soot, etc. by combustion, and maintenance effort is significantly reduced. 3

SPLIT TYPE Satisfying both of High Power and High realizes m realizes powerful heating capacity and high water temperature at cold winter, suitable for cold region. Powerful Heating High power models realize high leaving water temperature and high heating capacity even at low ambient temperature by newly developed "Linear Control Injection Technology". It is possible to provide high water temperature and warm rooms immediately in cold region during winter. NEW model 11 14 Single Phase power supply s s HIGH LEAVING WATER TEMPERATURE High leaving water temperature of 60 C keeps to - C of outdoor temperature without using backup heater. At - C At - C outdoor temperature outdoor temperature 50 C 60 C Hot water Hot water No backup heater WOYG112LBT WOYG140KLBT WSYG140DB6 Leaving water temperature ( C) 60 50 40 11 14 16 3 Phase power supply s - - -10-5 0 5 Outdoor temperature ( C) HIGH HEATING CAPACITY () Keeping the high heating capacity at even low outdoor temperature. WOYK112LAT WOYK140LAT WOYK160LAT s WSYK160DA9 5 6 8 10 13 16 Abundant line-up meets a wide range of needs. s () 10 5 11 (WOYG112LBT) FUJITSU GENERAL s advanced Linear Control Injection Technology () Injection port Rated level Keep rated capacity at low outdoor temperature 0-25 - - -10-5 0 5 Outdoor temperature ( C) Twin Rotary Compressor with Linear Control Injection port AOYA18LALL AOYA24LALL AOYA45LBTL AOY54LJBYL AOYA30LBTL WSYA050DA WSYA065DA WSYA080DA WSYA095DA WSYA128DA WSYA5DA Heating cycle Linear Control Injection Evaporator Water Heat exchanger It realizes the high condensing temperature without overheating discharge gas temperature by Linear Control Injection process during compression. Therefore, the condensing temperature rises up higher than normal circuit. A higher hot water temperature is realized by controlling the injection amount according to the usage state. Linear Control Injection High compression Normal refrigerant circuit 4

ore comfort High Efficiency Energy efficiency is improved by the linear Control Injection Technology and the optimization of refrigerant cycle control. High power model realizes high performance and high efficiency by adopting twin sensors and control technology corresponding to hot water heating. HIGH Wide Operation Range 4.30 3.90 *The data refer to 16 type Condition : Outdoor Temp. 7 C Heating Temp. 35 C. Proportion of primary energy into heating energy of 100% Primary Energy Consumption* Direct electrical heating 278% Oil heating 117% Gas condensing boiler 109% 79% *Electricity loss is different due to power plant. Efficiency of power plant : 36% Optimization of refrigerant cycle operation () Accurate temperature control by DC inverter technology High Temperature Improvement operation range depending on the optimization of refrigerant cycle control 35 C 24 C 0 C Temperature sensor Refrigerant Pressure sensor Constant 0 C Time Energy heating 100% Water heat exchanger Hot water Heating cycle V-PAM inverter technology Intelligent Control 2 ZONE INDIVIDUAL CONTROL* (Split type only) Outdoor unit Valve AND MORE Automatic temperature regulation in accordance with heating curve. (Depends on terminal and outdoor temperature) Cooling operation is possible* Anti-Legionella function Additional electric heater control for backup 2 stage Low noise mode* ( only) Peak cut function* ( only) High Reliability HIGH CLEAN AND DURABILITY Corrosion protected No fouling through heat exchanger construction Hot water is permanently available Stainless steel buffer tank Optimum co-axial heat exchanger Anti-freeze is unnecessary Heated water Highly efficient water heat exchanger Double-pipe water heat exchanger with built-in tank to reduce loss EASY INSTALLATION & MAINTENANCE All hydraulic components built in no additional selection for water flow required Lifting bars for an installation without any difficulty or risk Easy access for maintenance operations Pump down operation ( only) EMERGENCY OPERATION System can be continuously supplied hot water by built in back up heater or boiler operation, even if an error is occurred as emergency. Backup heater 2nd Circuit Kit Pump Pump Boiler* Floor heating *Optional parts are required. Over 50 C possible ~40 C Warm refrigerant flow -25 C - C Floor heating *When additional boiler connected 5

MONOBLOC TYPE All-in-One type with Easy Access for Installation and M Compact model 8 10 Comfort and energy saving realized by world's top class compact design All-in-One Model Compact design which built in all hydraulic components and the heat pump unit make refrigerant piping work unnecessary. Easy installation and maintenance are realized. outline (Monobloc type) Easy installation & maintenance! Ambient air Water heat exchanger Monobloc unit Control box Heating cycle Control box UTW-SCBYA Hot water WPYA080LA WPYA100LA Evaporator Compressor Pump High Efficiency Technology DC INVERTER Smooth water temperature control realized by DC inverter control. HIGH EFFICIENT PLATE WATER HEAT EXCHANGER Very compact size achieved by a thin high-efficiency heat exchanger DC FAN MOTOR High performance, high efficiency small DC fan motor mounted. DC TWIN ROTARY COMPRESSOR High efficient DC twin rotary compressor corresponding to low outdoor temperature 6

aintenance Compact & High Performance HIGH Intelligent Control WIRED REMOTE CONTROLLER (CONTROL BOX) IS ADOPTED STANDARD. Control box High is realized by using a DC twin rotary compressor, inverter technology, and high efficient water heat exchanger. 8 10 4.50 4.35 *Condition : Outdoor Temp. 7 C Heating Temp. 35 C. HIGH LEAVING WATER TEMPERATURE High leaving water temperature of 55 C keeps to - C of outdoor temperature without heater. Leaving water temperature ( C) 60 55 50 40 - - -10-5 0 5 Outdoor temperature ( C) COMPACT & LIGHT WEIGHT DESIGN 881.5 mm 850 mm 55 C At - C outdoor temperature Hot water Weight 82kg 330 mm No backup heater AUTOMATIC HEATING CURVE CONTROL Automatic temperature regulation in accordance with heating curve (Depends on heating terminal and outdoor temperature) Leaving water temperature ( C) 60 50 40 30 High Reliability ANTI-FREEZE FUNCTION Water circulation and compressor can be automatically performed at low outdoor temperature. Freezing of circulated water can be prevented. High - AND MORE Floor heating - Cooling operation is possible* Anti-Legionella function Possible to docking the boiler and electric heater for backup Outdoor temperature Automatic temperature control with heating curve Chosen heating curve zone -10-5 0 5 10 Outdoor temperature ( C) *Optional parts are required. Wide Operation Range Possible to operate heating under - C of outdoor temperature 35 C - C 0 C Setting temperature Low ON Anti-freeze mode Time EASY INSTALLATION & MAINTENANCE No installation of refrigerant circuit connections. Closed type enables decrease in the supply frequency of circulating water. Easy access for maintenance operations OFF 7

SYSTEM CONFIGURATION Total solution provides comfort to all over the home SPLIT TYPE Basic Unit System Components (Options) Controller (Option) Heating & Hot Water (Field Supplied) Hot Water (Outdoor) Indoor Unit Boiler (Field Supplied) DHW Tank Hot Water WSYG140DB6 WSYK160DA9 WSYA050DA WSYA065DA WSYA080DA WSYA095DA WSYA128DA WSYA5DA Boiler Connection Kit UTW-KBSXA & Balancing Vessel UTW-TEVXA UTW-TXA UTW-T30XA Shower Bath Outdoor Unit 2nd Circuit Kit UTW-KZSXA WOYG112LBT WOYG140KLBT Fan Coil Swimming Pool WOYK112LAT WOYK140LAT WOYK160LAT Heat Exchanger UTW-ESPXA & Swimming Pool Kit UTW-KSPXA Floor Heating AOYA18LALL AOYA24LALL Room Thermostat AOYA30LBTL UTW-C55XA Remote Control Gas Refrigerant Liquid Refrigerant AOYA45LBTL AOY54LJBYL UTW-C75XA Supply Hot Water Control Cable Return Water OPTIONAL PARTS 2nd Circuit Kit *Split type only Boiler Connection Kit Balancing Vessel DHW Kit DHW Tank 0L DHW Tank 300L High Flow Rate Circulating Pump Kit UTW-KZSXA UTW-KBSXA UTW-TEVXA UTW-KDWXA UTW-TXA UTW-T30XA UTW-PHFXA 8

MONOBLOC TYPE Basic Unit System Components (Options) Controller (Option) Heating & Hot Water (Field Supplied) Hot Water (Outdoor) Monobloc Unit Boiler (Field Supplied) DHW Tank Hot Water Compact model WPYA080LA WPYA100LA Boiler Connection Kit UTW-KBSXA & Balancing Vessel UTW-TEVXA Shower UTW-TXA UTW-T30XA Bath Control box UTW-SCBYA Fan Coil or Floor Heating Heat Exchanger UTW-ESPXA & Swimming Pool Kit UTW-KSPXA Swimming Pool Room Thermostat UTW-C55XA or Remote Control Note: 1. Not available to 2 heating circuits. 2. Optional remote controller allows one controller only. Supply Hot Water Return Water UTW-C75XA Control Cable Swimming Pool Kit Heat Exchanger for swimming pool Cooling Kit Cooling Kit (High flow rate) Remote Control Room Thermostat External Connect Kit UTW-KSPXA UTW-ESPXA UTW-KCLXA UTW-KCHXA UTW-C75XA UTW-C55XA UTY-XWZXZ2 9

CONTROL Split & Monobloc type Smart & Comfort Control The outdoor temperature is detected by sensor and the heating water temperature is controlled automatically. The setting of room temperature and operation mode can be easily set. A wide range of control from heating to hot water supply and swimming pool is possible by combining with abundant optional parts. Convenience PROGRAMMED OPERATION The setting of programmed operation can be easily set. Changing the heating mode linked with time is possible. Simple operation mode setting Selecting the heating mode Heating mode Automatic mode Comfort/Reduce mode switching automatically according to outdoor temperature Reduce mode Constant reduce temperature Comfort mode Constant comfort temperature Protection mode Stand-by mode with anti-frost protection Day-Weekly timer setting The day-weekly timer can be set up for up to 3 times per day. Allows separate settings for each day of the week. Monday-Friday Saturday-Sunday Large LCD display Operation status display Error display / Error history Navigation and setting Selecting the heating menu Setting program timer 6 9 12 18 21 24 Time Holiday timer setting The holiday timer can be set up for up to 8 periods If you are absent for a long time in the winter, freezing of room can be prevented. 6 9 12 18 21 24 Time Holiday timer Day-Weekly timer 11 12 1 2 3 Date Comfort FLEXIBLE HEATING CIRCUIT Automatic hot water temperature control matched to the application can be set. In addition, set temperature coefficient offset can be adjusted easily high or low side matched to the usage conditions. High Leaving water temperature ( C) Low Low - 4.5 C +4.5 C High Outdoor temperature ( C) Setting heating curve Extendibility DIVERSE OPERATION CONTROL Meets diverse needs by combining with optional parts. OPTIONS 2-temperature simultaneous heating Floor heating + heating (Split type only) Operation together with boiler at low outdoor temperature Temperature control of swimming pool (Controlled at 35 C) REMOTE CONTROL-EXTENSION Optional remote controller allows controls of hot water depending on indoor temperature. ANTI-LEGIONELLA FUNCTION The growth of Legionella in DHW tank is suppressed and safe and clean hot water is supplied at all times. Outdoor Sensor Room Thermostat (Option) Floor heating Remote Control (Option) or (Split type) 10

DIMENSIONS SPLIT TYPE Unit : mm Outdoor Units AOYA18LALL / AOYA24LALL AOYA30LBTL Outdoor Units WOYG112LBT / WOYG140KLBT Outdoor Units AOYA45LBTL / AOY54LJBYL Top view 31 330 12 900 77 Top view Top view 31 330 12 900 77 300 790 66 578 10 540 347 400 830 Front view 21 Front view 1290 650 21 Bottom view Front view Bottom view 650 Outdoor Units WOYK112LAT / WOYK140LAT / WOYK160LAT 400 Bottom view 31 330 12 Top view 900 Indoor Units WSYK160DA9 Indoor Units WSYA050DA / WSYA065DA / WSYA080DA WSYA095DA / WSYA128DA / WSYA5DA 1290 450 650 MONOBLOC TYPE Unit : mm Compact model WPYA080LA / WPYA100LA 275 90 60 Control Box UTW-SCBYA 330 5 540 5 180 110 335 357 21 1034 1000 Front view 400 Bottom view 240 88 480 522.5 ØM26x34 235 Front view 116 ØM26x34 Top view 850 881.5 436 2 171 Front view 11

SPECIFICATIONS Type Series name High Power series Split system Comfort series Capacity range () 11 14 11 14 16 11. 14.00 11. 14.00 16.00 +7 C / +35 C floor heating *1 Input power 2.54 3.25 2.51 3.22 3.72 4.40 4.30 4.46 4.35 4.30 11. 14.00 11. 14.00.10 +2 C / +35 C floor heating *1 Input power 3.54 4.51 3.45 4.40 4.87 3.16 3.10 3.25 3.18 3.10 11. 14.00 11. 14.00.00-7 C / +35 C floor heating *1 Input power 4.16 5.47 3.92 5. 5.55 2.69 2.56 2.86 2.72 2.70 9.60 12.00 10.50 13.10.10 +7 C / +45 C radiators *1 Input power 2.77 3.50 2.90 3.70 4.42 3.46 3.42 3.62 3.54 3.42 9.60 12.00 10.50 13.10 14.50-7 C / +45 C radiators *1 Input power 4.12 5.32 4.16 5.39 6.38 2.33 2.26 2.52 2.43 2.27 Backup heater Capacity pcs. 6.0(3.0 2 pcs.) 6.0(3.0 2 pcs.) 9.0(3.0 3 pcs.) 9.0(3.0 3 pcs.) 9.0(3.0 3 pcs.) Model name WSYG140DB6 WSYK160DA9 Power source 1Ø 230V, 50Hz 3Ø 400V, 50Hz Water circulation Rated 32.1 40.1 32.1 40.1 45.9 L /min Mini / Max.0 / 40.0 25.0 / 50.0.0 / 40.0 25.0 / 50.0 28.3 / 56.7 Dimensions H W D mm 1034 450 480 Weight (Net) kg 52 53 Buffer tank capacity L 25 Expansion vessel capacity L 8 Leaving water temperature range C 8 ~ 60 Water pipe connection diameter Flow / Return mm Ø25.4 / Ø25.4 Model name WOYG112LBT WOYG140LBT WOYK112LAT WOYK140LAT WOYK160LAT Power source 1Ø 230V, 50Hz 3Ø 400V, 50Hz Current Rated 10.8 13.7 3.60 4.80 5.50 A Max 21.0 24.0 8.50 9.50 10.50 Noise level (Sound pressure) db(a) 55 *2 56 *2 53 *2 55 *2 56 *2 Dimensions H W D mm 1290 900 330 Weight (Net) kg 92 99 Refrigerant R410A Refrigerant amount kg 2.50 Additional refrigerant charge amount g/m 50 mm Ø9.52 Diameter mm Ø.88 Connection 5 / pipe Operation range Length Length (chargeless) Height difference Liquid Gas Mini / Max Max Max Heating m m m C -25 ~ 35 5 4.60 1.07 4.30 4.31 1.36 3.16 4.80 1.77 2.70 4.17 1.23 3.38 4.05 1.78 2.28 3.0(1.5 2 pcs.) WSYA050DA 14.3 9.0 / 18.3 6 8 10 6.50 8.00 10.30 1.63 2.00 2.58 4.00 4.00 4.00 5.59 6.39 8.69 2.05 2.34 3.21 2.73 2.73 2.71 5.60 7.00 8.10 2.24 2.54 3.52 2.50 2.75 2.30 5.40 6. 8.30 1.61 1.88 2.51 3.35 3.30 3.30 5.10 5.90 7.00 2.32 2.62 3.33 2. 2.25 2.10 3.0(1.5 2 pcs.) 3.0(1.5 2 pcs.) 6.0(3.0 2 pcs.) WSYA065DA WSYA080DA WSYA095DA 1Ø 230V, 50Hz 18.6 10.0 / 23.3 AOYA18LALL 5.16 7.25 10.80 39 *3 578 790 300 40 1.25 Ø6.35 Ø12.70 5 / 22.9 14.3 / 28.3 27.2 16.7 / 35.0 13 13.70 3.42 4.00 12.31 3.87 3.18 11.55 4.37 2.64 9.70 2.98 3.26 9. 4.30 2.14 6.0(3.0 2 pcs.) WSYA128DA 36.7 25.0 / 50.0 16 16. 4. 3.90 13.94 4.77 2.92 12.40 4.77 2.60 13.30 4. 3.17 11.00 5.37 2.05 6.0(3.0 2 pcs.) WSYA5DA 44.4 25.0 / 50.0 1034 450 480 52.5 25 8 8 ~ 50 Ø25.4 / Ø25.4 AOYA24LALL AOYA30LBTL AOYA45LBTL AOY54LJBYL 1Ø 230V, 50Hz 8.27 10.40 13.70 17.10 11.22 16.00 19.00 24.50 40 *3 55 *2 55 *2 55.5 *2 578 790 3 830 900 330 1290 900 330 1290 900 330 44 64 98 105 R410A 1.70 2. 3.35 3.40 40 50 40 Ø6.35 Ø9.52 Ø9.52 Ø9.52 Ø.88 Ø.88 Ø.88 Ø.88 5 / 5 / 5 / 5 / - ~ 24 Type Series name Monobloc system Compact series Capacity range () +7 C / +35 C floor heating *1 +2 C / +35 C floor heating*1-7 C / +35 C floor heating *1 +7 C / +45 C radiators *1-7 C / +45 C radiators *1 Input power Input power Input power Input power Input power Model name Monobloc unit Power source Rated Water circulation Mini / Max Current Rated Noise level (Sound pressure) Dimensions H W D Weight (Net) Expansion vessel capacity Water pipe connection diameter Flow / Return Refrigerant Refrigerant amount Leaving water temperature range Operation range Heating L /min A db(a) mm kg L mm kg C C 8 10 8.00 10.00 1.78 2.30 4.50 4.35 7.40 8.10 2.73 3.00 2.71 2.70 7.10 8.00 2.93 3.32 2.42 2.41 7.80 9.80 2.23 2.88 3.50 3.40 6.50 7.00 2.98 3.31 2.18 2.11 WPYA080LA WPYA100LA 1Ø 230V, 50Hz 22.9 28.7 10.0 / 30.0 10.0 / 30.0 8.30 10. 51*2 51*2 881.5 850 330 82 8 Ø25.4 / Ø25.4 R410A 1.5 8 ~ 55 - ~ 35 *1. The values of heating capacity/power input/ are based on measurement of EN14511 standard. Usage environment, such as operation of the heating equipment, room temperature, and controller adjustments, may cause disparities between practically determined and these values. *2. Sound pressure level measured at distance of 1m from the device and at a height of 1.5m above ground in free field *3. Sound pressure level measured at distance of 5m from the device and at a height of 1.5m above ground in free field Distributed by : ISO 9001 ISO 14001 Certified number:09 100 89394 Certified number:09 104 9245 Fujitsu General (Thailand) Co., Ltd. is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas. The colors may be different from the actual colors because this catalog is printed matter. Specifications and design subject to change without notice for further improvement. Please check with your dealer Copyright 09-10 Fujitsu General Limited. All rights reserved. 1116, Suenaga, Takatsu-ku, Kawasaki 213-8502, Japan http://www.fujitsu-general.com/ 7NF003-1104E