DELTA Classification Report

Similar documents
Classification Report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Centrum stavebního inženýrství a.s.

TFI Report Classification

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Additional Reaction to Fire Classification Report

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Additional reaction to fire classification report No H

Classification report

Classification of reaction to fire performance in accordance with BS EN : A1: 2009 on Sandwich Panel, WP 50.

Centrum stavebního inženýrství a.s.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Test Report: ICL/CR15/11/087

Reaction to fire classification report No C-rev.1

Üntel is ready for CPR

Contact person Date Reference Page Richard Johansson P (2) Fire Research

Reaction to fire classification report No C

Classification of reaction to fire performance in accordance with EN : A1: 2009 on Superfoil SFNC. Prepared for:

Test Report No: ICL/H17/7967

New European Cable Testing and Classification

CLASSIFICATION REPORT

TFI Report Classification

CPR: EUROCLASSIFICATION & TESTS FOR CABLES

BS EN 13823: A Report To: Contra Vision. Document Reference: Date: 25 th November Issue No.: 1

Analysis Report

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Form: KSD-100:10 Page 1 of 3

Construction Products Regulation (CPR) and BS 6701

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

PUBLIC SUMMARY REPORT OF THE EGOLF EN 13823

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Reaction to fire testing of Vescom vinyl wall covering with a Fibre Structure, a total weight of 550 g/m 2 according to EN 13823:2002

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Technical Note. Noise emission from Dehumidifier Type C65E TC Project no.: I Page 1 of July 2016

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Construction Products Regulation (CPR)

Technical Note. Noise emission from Dehumidifier Type C35E-3.3 and Type C35E-5.6. TC Project no.: T Page 1 of 10.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Supplementary type approval testing of Selco modules

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Type approval testing of miscellaneous smoke and heat detectors for marine applications

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

BS EN 13823: A Report To: Durabuild Technologies Pvt. Limited. Document Reference: Date: 22 nd February Issue No.

Technical Note. Noise emission from Dehumidifier Type C22/CR100. TC Project no.: T Page 1 of January 2016

YOUR GUIDE TO UNDERSTANDING CPR

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

New European Fire Testing Classification for Construction Products

~,oeti. Report VN Classification Report. Reference

CLASSIFICATION OF FUNCTION IN FIRE IN ACCORDANCE WITH DIN : with direct field of application FIRES-CR AUPE

Copper and Fibre Cabling Infrastructure Offering - Europe

CLASSIFICATION IN REGARD OF REACTION TO FIRE according to EN :2007

BCTC CARPET TECHNICAL CENTRE

AUGUST 2016 CONTENTS:

Test Report: ICL/H18/9039 Rev 1

~~oeti. Report VN71 O Classification Report. Reference

Test Report. Appliance EMF Testing

SD119 Range of Conventional Smoke and Smoke/Heat Detectors (refer to attached appendix for details and conditions)

Gern Glas Order no. 0302/ Industrivej 4 Page 1 of Sorring Appendicis 1 Danmark Initials MJLD/MFRI

EMC TEST REPORT for HUIZHOU FREEWAY ELECTRONIC CO., LTD. Car DVD/Navigation Player

BT Cables Technical Seminar CIBSE South Wales Region. Nov 17

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

TNO report. Centre for Fire Research Van Mourik Broekmanweg 6 P.O. Box AA Delft. T F

gent warn nfire No, 16209C Reaction to fire class ification report lntroduction Owner of the classification report

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

Report VNNF Test Report

TYPE APPROVAL CERTIFICATE

Centexbel. General certification regulations. Construction products

Cooper Lighting & Safety Limited Wheatley Hall Road, Doncaster, DN2 4NB, United Kingdom

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

Report VNLF Test Report

File E90165 Vol. 2 Index Page 1 Issued: Revised: Construction United States Type Canadian Type Section

REVIEW ON TWO PERFORMANCE-BASED TESTS FOR ASSESSING FLAME SPREAD IN HONG KONG

Type: Play house Length: 1195 mm Width: 1195 mm Height: 1740 mm Materials: 18,7 mm laminated wood

MPE TEST REPORT 2APNR-GW631Q R1805A0254-M1V1

IEC SYSTEM FOR MUTUAL RECOGNITION OF TEST CERTIFICATES FOR ELECTRICAL EQUIPMENT (IECEE) CB SCHEME. Additional Information on page 2.

Test report. NanoPhos coating system EPR and EEN. Name of client: NanoPhos SA. Date: Pages: 5 Encl.: 1 Ref: BP / KTO

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

+ = FIRE LABORATORY INTRODUCTION. APPLUS+ LGAI - Our company history. High Technology Knowledge. Customer Confidence. Branding

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

MFPA Leipzig GmbH Prüf-, Überwachungs- und Zertifizierungsstelle für Baustoffe, Bauprodukte und Bausysteme

Development of a European approach to assess the fire performance of facades

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

FAÇADE FIRE TESTS Towards a new European standard method

Not all insulation is the same! from fire testing to real fires.

The Danish Energy Authority to carry out inspections in June and July 2012

MEASUREMENT AND TEST REPORT

ei DG UV Test EC-Type Examination (Module B) Certificate

High Performance LSZH Fire Resistant Cable

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

BS EN : Measurements Of Smoke Density Of Electric Cables. WF Report Number. Date: 17 th November Test Sponsor:

GUARDIAN FIRE TESTING LABORATORIES, INC.

Transcription:

DELTA Classification Report TEST Reg. no. 19 Reaction to fire classification report for electric cables: Cat 6A U/FTP 500 MHz FRNC Performed for Caleb Cable Industrial Ltd. no.: Page 1 of 9 19 December 2016 DELTA Venlighedsvej 4 2970 Hørsholm Denmark Tel. (+45) 72 19 40 00 Fax (+45) 72 19 40 01 www.delta.dk/cable VAT No. 12275110 This report is issued under the rules of DANAK (Danish Accreditation) and ILAC (International Laboratory Accreditation Cooperation) including its MRA (Mutual Recognition Arrangement). Further information can be found at www.danak.dk and www.ilac.org. The report must not be reproduced, except in ful l, without the written approval of DELTA.

Page 2 of 9 DELTA Headquarter, Hørsholm Denmark

Page 3 of 9 Title Product area Product description Product identification Reaction to fire classification report for electric cables Power, control and communication cables Screened communication cable (U/FTP) with solid conductors, 4 twisted pairs, LSZH jacket Cat 6A U/FTP 500 MHz FRNC Part no. CCUFTPCAT6A4PB2 no. Client Contact Caleb Cable Industrial Ltd. #107 Luyuan Rd, Ke Yuan Cheng Tangxia, Dongguan Guangdong China Alex Yuan, Jason Jia Specification EN 13501-6:2014 Results Prepared by Reaction to fire classification: B2 ca -s1,d0, a1 Nis Jepsen, revised by Lars Lindskov Pedersen Date 19 December 2016 Responsible Lars Lindskov Pedersen, Test Manager DELTA LAN Components and Systems Testing

Page 4 of 9 Table of content Page 1. Introduction 5 2. Details of classified product 6 2.1 General 6 2.2 Product description 6 3. Reports and results in support of this classification 7 3.1 Reports 7 3.2 Results 7 4. Classification and field of application 8 4.1 Reference of classification 8 4.2 Classification 8 4.3 Field of application 8 5. Limitations 9

Page 5 of 9 1. Introduction This classification report defines the classification assigned to Product name Cat 6A U/FTP 500 MHz FRNC in accordance with the procedures given in EN 13501-6. CLASSIFICATION OF REACTION TO FIRE FOR ELECTRIC CABLES IN ACCORDANCE WITH EN 13501-6 Sponsor Prepared by Caleb Cable Industrial Ltd. #107 Luyuan Rd, Ke Yuan Cheng Tangxia, Dongguan Guangdong China DELTA Dansk Elektronik, Lys & Akustik (DELTA Danish Electronics, Light & Acoustics) Venlighedsvej 4 2970 Hørsholm DENMARK Notified Body No. 0199 Product name Classification report no. Cat 6A U/FTP 500 MHz FRNC DK0199-EC-2016567 Issue number 02 Date of issue 19 December 2016 This classification report consists of 9 pages and may only be used or reproduced in its entirety.

Page 6 of 9 2. Details of classified product 2.1 General The product, Cat 6A U/FTP 500 MHz FRNC, is defined as a Type of product Electric cable intended for supply of communication in buildings and other civil engineering works with the objective of limiting the generation and spread of fire and smoke 2.2 Product description The product, Cat 6A U/FTP 500 MHz FRNC, is described in the reports provided in support of classification listed in Section 3.1.

Page 7 of 9 3. Reports and results in support of this classification 3.1 Reports Name of Laboratory Name of sponsor Report no. Test method DELTA Caleb Cable Industrial Ltd. T213030-05, rev. 1 EN 60332-1-2:2004 +A1:2015 EN 50399:2012 EN 60754-2:204 3.2 Results Test method Parameter No. tests Test method Continuous parameter mean m Compliance with parameters EN 60332-1-2 H 425 mm 1 - Compliant FS 1.5 m (B2 ca ) 0.46 m Compliant THR 1200s 15 MJ (B2 ca ) 3.2 MJ Compliant Peak HRR 30 kw (B2 ca ) 12.3 kw Compliant EN 50399 FIGRA 150 W/s (B2 ca ) 86.1 W/s Compliant 1 TSP 1200s 50 m 2 (s1) 12.7 m 2 Compliant Peak SPR 0.25 m 2 /s (s1) 0.05 m 2 /s Compliant Flaming droplets/particles - Compliant No occurrences (d0) ph > 4.3 (a1) 5.84 Compliant EN 60754-2 Conductivity < 2.5 µs/mm (a1) 3 0.39 µs/mm Compliant

Page 8 of 9 4. Classification and field of application 4.1 Reference of classification This classification has been carried out in accordance with EN 13501-6. 4.2 Classification The product, Cat 6A U/FTP 500 MHz FRNC, in relation to its reaction to fire behaviour is classified: B2 ca The additional classification in relation to smoke production is: s1 The additional classification in relation to flaming droplets / particles is: d0 The additional classification in relation to acidity is: a1 The format of the reaction to fire classification for electric cables is: Fire behaviour Smoke production Flaming droplets Acidity B2 ca - s 1, d 0, a 1 Reaction to fire Classification: B2 ca -s1,d0,a1 4.3 Field of application This classification is valid for the following product parameters as determined in the extended application process according to CLC/FprTS 50576: Colour of jacket Any Colour of insulation Any Marking Any The classification is valid for all end use applications.

Page 9 of 9 5. Limitations This classification document does not represent type approval or certification of the product. The classification assigned to the product in this report is appropriate to a declaration of conformity by the manufacturer within the context of system 3 attestation of conformity and CE marking under the Construction Products Regulation. The test laboratory has, therefore, played no part in sampling the product for the test, although it holds appropriate references, supplied by the manufacturer, to provide for traceability of the samples tested.