MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17

Similar documents
Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Installation & Manual. Model T-25

INSTRUCTION. for installation and operation of solid fuel fireplace

Rocket heater GAMERA

Operating and installation instructions for Fire Lotus H586

Furthermore, the fire flaming in your FIREPLACE hearth creates an intimate atmosphere for your family and friends.

INSTRUCTIONS FOR INSTALLATION AND MANUAL Solid fuel stove for central heating THERMO IN

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

INSTRUCTION MANUAL. for installation and operation of solid fuel cookers. Victoria and Victoria Lux

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

MANUAL INSTRUCTION Solid fuel cooker for central heating - SUPER-THERMO MAGNUM

Dovre 700CBW Cast Iron Wood Stove INSTALLATION INSTRUCTIONS 700G/1095

INSTRUCTIONS FOR INSTALLATION AND USE OF ZINO 700,900,1100

'' Stone Fireplace Model# SRFP41301 Instructions Manual

USER MANUAL FOR SOLID FUEL STOVE VOLCANO - 24kW

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

Combined boiler. for solid fuel and pellets

March 9th, 2009 Reviewed MYSTERE wood burning stove 490, rue de l'argon Québec (Québec) G2N 2C9 Phone: Fax :

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

1. Contents Principle General information Parts list Assembly Technical drawing... 18

MODEL SORDO SORDO SORDO SORDO 80 Flatline

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

Warmth, from the heart of J.A. Roby

MG SERIES - ENERGY CLASS A. Meeting the. MG series 1 / 7

Page 1. Cube Ref:

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL

DÉCOFIRE. Contemporary CHIMENEA. Assembly, Safety & Operating Instructions FOR OUTDOOR USE ONLY READ INSTRUCTIONS CAREFULLY BEFORE ASSEMBLY OR USE.

Cassette inserts and fireplace doors

Technical certificate, instruction for installation and use. Sauna heater VIENYBĖ- P K6M ĮST :2003 ГОСТ

INSTRUCTION MANUAL & SERVICE MANUAL ORLAN 96 SUPER ORLAN 130 SUPER

Installation of a Brunner fireplace. General Indications

Sauna Heater. Installation and Manual

CARE & INSTRUCTION MANUAL

LP GAS PIZZA OVEN USER MANUAL

Solid fuel-burning stove * THERMO LAVA *

INSTRUCTION MANUAL & SERVICE MANUAL ORLIGNO 200

Corn Flame Energy Corn Stove Model 3000

#8 Maintaining your heating system

Contents. Gas Fireplace Types. Wood Fireplace. Electric & Ethanol Fireplaces. Pellet Fueled Appliances. The Original Flame

ULTIMATE INSET LIVE FUEL EFFECT GAS FIRE MODEL 417 OWNER GUIDE

INSTRUCTIONS FOR USE OF COMBINED BOILER INTENDED FOR COMBUSTION OF BOTH PELLETS AND SOLID FUEL ABC COMBO

SOLID FUEL RANGE COOKER TYPE 9114 TYPE /2016 0

Website:

Installation instructions and how to use and look after your built-in cooker hoods D5625/22/45 and D5855. NEFF (UK) Ltd

PER-EKO type KSW & KSW PLUS Instruction Manual

Central heating. Central k W, Central k W SN-EN-9/16

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

M650-38A-OAK ELECTRIC FIREPLACE HEATER NDF-65NB-1 INSTRUCTION MANUAL

16 Ultiflame Inset Electric Fire

Chimney Fire Prevention

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

Kalahari DECORATIVE FUEL EFFECT GAS FIRE

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

Framtidens toaletter FLAME Användarmanual Ohjekirja User manual

PELLETS BURNER 15-60kW MOC

Installation and Operating Instructions

Masterflamme Convection Wood Stove

WARNING! For your safety

RS Chimney Fan for Solid Fuel Applications

Instruction Manual: Le Jurassien Ref 3701

VULCAIN OIL STOVE. Warmth, from the heart of J.A. Roby. Certified and tested according to CAN/CSA B UL norms

ISO 9001 TUV CERT CE

Instructions for Operation and Maintenance of Containers

2 x 2/ 2x3/ 2x4 SAUNA CUBE. health, beauty, peace of mind SPECIFICATIONS WINDOWS AND DOOR COLOR OF WOODROOF SHINGLES TRANSPORTATION MAINTENANCE USAGE

Operating Manual USA & Canada.

Leading European manufacturer of fireplace stoves and fireplace inserts

INSTALLATION AND OPERATION MANUAL

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

INSTALLATION AND OPERATING MANUAL

EYS SEPARATOR EYS 01 G. USER MANUAL for EYS SCREW-PRESS SEPARATOR MODEL EYS 01 G. User Manual for EYS 01G Screw-Press Separator

Troubleshooting and Maintenance: Wood Stoves

RS Chimney Fan for Solid Fuel Applications

General instructions for the Installation and use of wood-burning stoves

ATMOSPHERE WOOD STOVE. Conforms to UL Std Certified to ULC Std. S627. June 1 st, 2013 Reviewed ATMOSPHERE

Leading European manufacturer of fireplace stoves and fireplace inserts. Fireplace inserts

QCM979D-38AGO ELECTRIC FIREPLACE HEATER NDF-65NB-3 INSTRUCTION MANUAL

REV.01 /

OPERATING INSTRUCTIONS. "CLASSIC" Range

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

CHESNEY S. Bio-Ethanol Installation & User Manual. model: EFB750. Issue 01

User manual (GB / IE) for appliances provided with an electronic ignition on the remote control. English. Read this document and store it carefully

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

MANUAL AND INSTALLATION PROCEDURE PRODUCT APPEARANCE

A1 MARS FG. Stone Vapnenac. Black. Gray >79% >7,9kW. Cleaning of glass. Fresh air connector. Three points closing. Heating power

It is critical to maintain the Beech Oven and associated equipment on a regular basis, to avoid the possibility of a serious fire or malfunction.

HIGHLANDER Wood and Multi-fuel Stoves

I n s t r u c t i o n m a n u a l f o r b u i l t - i n h o o d. Model code: BORA600

Masterflamme Convection Wood Stoves Perfect combustion with unique design

Tornado Operations & Maintenance Manual

FIREPLACE INSERT, MODEL VOLCANO PLUS OWNER S MANUAL - INSTALLATION - OPERATION. Save These Instructions for Future Reference.

Wood logs boiler with a gasication eect IGNIS KW. INSTRUCTIONS MANUAL for usage and maintenance

Index. Operating Instructions. Installation Instructions

WARNING VILPRA WOOD WOOD HEATER MANUAL. Marketing: SpaDealers. Korsnäs FINLAND +358 (0)

H E AT I N G S Y S T E M S ECS STEEL BODY CENTRAL HEATING HOT WATER BOILER

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

Operating Instructions

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Transcription:

MANUAL FOR USE AND INSTALATION STOVE MODELS: D11-D17 CE Tested by the DIN EN 13240 15a B-VG Austria Type 1 Color Emajl d.o.o. Alaginci 87 a 34000 Požega Croatia www.color.hr team@color.hr 1

Attention! Prior to installation and start, do not miss to check whether there was, due to the transportation, any damage on the functional parts (air regulators, mantle, seals, door, chimney connector, etc.). If you have noticed damage, please contact our customer service. Fireplace may not be modified! Disposal of packaging Packaging protects fireplace from damage during the transport. Packaging materials are chosen from aspects of environmental and waste, and can be recycled. PRACTICAL! Wooden part of packaging can be used for heating. It is affordable to cut it on small pieces and use it as firewood. 2

Congratulations on purchase of this fireplace from the production series of the company Color emajl d.o.o. This manual for usage will introduce you to the functions and proper handling of the fireplace. Buyer and users are obligated, based on this manual, to inform them about proper handling of the fireplace! Our guarantee is valid only if the following guidelines are complied. Please keep this manual, in order to remind yourself how to properly handle the fireplace prior to the next heating season. 1. Description Fireplace is made of welded steel construction. In the middle part there is stokehole paneled with isolation. Beneath the stable cast iron bar, an ashtray is located, and beneath the ashtray there is wood storage. Fireplace is from the upper side closed with heating storage. This fireplace works on the principle of convection area, in which the air that is inside of the fireplace, warms in air space, and after the warming, gets out from the stove into the room. 2. General National and European standards, local and construction regulations, fire protection law and regulations must be obligated. Because of that inform the chimney sweep from your country. There must be provided enough fresh air into the room where the fireplace is installed. Calculation of chimney is done according to DIN EN 13384-1 and DIN EN 13384-2 with specific values which can be seen in this manual under the section 4. Your fireplace can be equipped with a connection for the external air supply (see image 1). In the room with controlled ventilation, there can be connection of air supply from the outside. In that case the additional pressure monitoring in the room is required. The required connection is available as additional equipment. Pay attention to the sealed tube pipes. The total length of pipe should not be longer than 6 meters, do not calculate reductions, as well as top of 3 pieces of 90 elbow. At standstill keep both regulators closed, in order for cold air not to be able to circulate throughout the chimney. Due to the cold outside air, condensation can be avoided by isolating the pipes. Chimney sub pressure must be in a condition to overcome those additional resistances. Fireplaces that are described in this manual are tested through DIN EN 13240 norm. Fireplaces of this type 1 can be connected on multi-paneled chimneys, if chimney dimensions allow it. Your chimney significantly contributes to proper work of your fireplace. Recommendations: Working level of chimney: min. 5 meters Cross-section of sub pressure max. 160 mm In any case, let your chimney be examined by an expert! If the fireplace is connected to the multi-paneled chimney, than in any case do not remove the helix that closes the door. The door must, after putting firewood into the stokehole, self-close, in order to prevent air influence on subpressure and intensity of fire, and in order to avoid danger that is related with stokehole. 3. Installation of the fireplace and the flue pipe connection 3.1. Flue pipe connection For connection to the chimney there should be used flue pipe that has 2 mm thickness. All connectors from fireplace into the chimney must be firm and tightly connected. Be careful that flue pipe does not enter into the free section of the chimney. Wall covering is recommended. Horizontal part of the flue pipe, compared with fireplace, must be situated on 90 or higher. Fireplaces that have connection to up or back, switchable cap should be once again securely attached with screws! 3

Picture 1 Attention! At too low but also at too high pressure there may come to a problem with fireplace work. Outdoor air supply If the deviation from the required pressure (section 4) is over 25%, suitable changes on the chimney should be made. A 3.2. Safety rules At fireplace installation, you must comply with safety rules (FeuVo). Pay attention on minimum required distance from the wall, flammable elements and on protection of the floor! Minimum distance 110 cm Model D16-17 with the 360 installation - In the area of thermal radiation A 135 cm All other D models B1 B2 C D 20 cm 20 cm Back space between wall and fireplace For the rotating D16-17 model-110 cm Side space between wall and fireplace For the rotating D16-17 model-110 cm 4. Technical specifications Fireplace Model Strength kw The Amount Of Exhaust Gas The Temperature Of the outgoing gas Pressure mbar Diameter Of the Flue pipe mm Diameter of the connection of the outdoor air supply mm Fuel D11-D17 7,0 5,6 g/s 360 0,12 150 100 Wood D11-D17 4,3 9,7 g/s 304 0,12 150 100 Ancit 5. General information about fireplace work Always use glove! Do not use any flammable liquid fluids for lighting fire. The door of the stokehole can be opened only when adding fuel. Use only suitable fuels (see section 5.2.). Check, is there enough quantity of fresh air in the room, when working on the open principle. Fireplaces can be used only by adults. Make sure that children are never alone near fireplace. Never leave fireplace for a longer period of time without surveillance. 4

Fireplace can be used only according to the instructions in this manual. 5.1. Start 1. Primary and secondary regulators open maximally! Be careful, if the flue pipe has integrated flap it should also be opened maximally. 2. 2-3 cubes for fire, place on the center of the stokehole and put on it firewood. 3. Light the cubes and just lean the door. It prevents condensation of gas on the cold glass. 4. After approximately 5 to 10 minutes, when the fire is fully burst, carefully open the door, put 1 to 2 pieces of the wood into the stokehole, and then close the door. 5. When the amount of putted fueled material becomes well flamed and burst, and the working temperature of the fireplace is achieved, gradually move the primary air regulator backwards, but the flame still must be further visible. At optimum sub pressure and qualitative fuel, the primary regulator can be completely closed. 6. The door of the stokehole can be opened again, only when the placed quantity of the fuel is burned, and when you want to put the new fuel. 7. It is recommended that the secondary air regulator is kept maximally opened, in order for the glass cleaning to become maximally efficient, and to avoid glass fogging. 8. With fuel quantity regulate the necessary heat of your room. Excessive fireplace work brings to unnecessary environment overload, moreover stokehole, glass and flue pipe pollution. 9. When using brown coal briquette, leave primary air regulator open. Possible odor appearance that generates due to protective paint drying will disappear after a short while. If the odor appears, open the windows of the room for a ventilation. ATTENTION!!! FOR PROPPER REGULATION OF PRIMARY AND SECUNDARY AIR; ASHTRY MUST BE TIGHTLY CLOSED! 5.2. Suitable materials for lighting Fireplace serves for combustion of natural wood, wooden briquette and brown coal briquette. Classical wood for fireplace is beech and birch. These types of wood have the highest burn degree; they burn cleanest, if they are storage on a dry place. For lighting do not use: Humidified wood or wood treated with protection repellants Paper and carton (except for disposal) Bark or plywood Plastic or other waste Fresh wood should be torn up and stored 12 to 18 months on open storage, but protected from rain. According to the manual, there can be used only wood with maximum humidity of 20%. 5

Rotating the fireplace (model D16 D17) Rotating stoves can be rotated up to 360 when the stove is freely in space. Pay special attention to the necessary security distances to combustible and / or load-bearing walls, as to combustible furnishings. The turning procedure must be carried out in the cold state of the stove! The required safety distance in the radiation range of the glass must be at least 135 cm! Picture 2: Security lock against unintentional twisting of the stove D16 - Pull the lever upwards+right to loosen the rotation lock D17 - unscrew security screw to loosen the rotation lock. 5.3. Emptying ashtray Be careful that the ashtray is regularly emptied and that too much ash is not accumulated. Otherwise, there is danger that the bar does not cool enough and damages in that way. Before emptying the ashtray, check is there any ardor left in the ashtray. Even though the ash is cold from the outside, it is possible that in the inner of the ash is ardor which can lead to the inflammation of waste bin. 5.4. Cleaning and maintenance Fireplace can be cleaned only when it is cold! It is recommended to clean the ash every day, which is occurred due to combustion. Never leave ash accumulates in the tank in way that it touches the bar, because it would disrupt circulation of primary air, gradually extinguishing the flame; except that, the bar would not be cooled enough and it would damage promptly. Pay attention while cleaning our fireplaces to not damage, scratched or brake essential parts of our product. For cleaning steel parts use non-abrasive detergents and soft rag, and after the cleaning wash it well to avoid that deposit of detergent damage material. Places where the product is equipped with glass, cleaning the glass should be done when the fireplace is cold, using normal detergent for washing the glass. In the case of solid deposits that should be removed, we recommend to use detergents that are sold in stores, and that are intended to that use. After washing wash out with clean water, and if there are condensates, do not wait until they are dried, rather swipe them immediately. 6

Attention! Fireplace color achieves its ultimate firmness only after several times achieves its rated temperature. To avoid color damaging, it is recommended to clean the fireplace surface only when the color achieves its ultimate firmness! Note in the case of chimney fire If the wrong or too humidified flue is used, it is possible that a chimney fires due to accumulation of deposits inside of the chimney. Immediately close all air regulators on the fireplace and call the fire department. After that, the professionals must secure, that on the entire exhaust system aren t any cracks or leaks. 5.5. Layout and usage of air regulators SECONDARY PRIMARY Open Close Close Open 7

6. Complaints and service For assessed malfunction complaint or bad product functioning do as instructed in the warranty card and on the address of service workshop. It is important to mention, if there comes to a complaint, contact the service workshop in Požega on telephone number 034/312-303 or fax 034/312-305. In the case of a need our service team will come to you. Purchase of the spare parts you can do through our services or directly from a factory. When doing the order, write the name of the spare part. Duration of the product, in terms of legal regulations is 6 years. During the duration period, we will ensure our service and supply of spare parts. Properly light a fire Please pay attention on minimum space between walls and flammable objects during the lighting a fire! Step no. 1: Cubes for fire lay on the grid of the stokehole (leave 2 ribs of the grid free), but do not remove rest of the ash from the stokehole. Now put a little of fuel (thick as a finger) across the cube for fire (around 15 pieces), on that put 4 to 6 logs (around 5 to 6 cm thick) and light a fire. During this phase of lighting a fire, the handle for primary and secondary air should be moved on open. Latch inside of the flue pipe should be opened. Step no. 2: Fireplaces with big glass should have in the beginning phase of lighting a lot of oxygen. Sequence to that, the door of the stokehole must at least 15 to 20 minutes only be leaned until the all wood is in flame. Now you can close the door. Step no. 3: When the fireplace is after 1 hour reached the working temperature, you may close the handle for the primary air (see the instructions). Step no. 4: During the adding of larger wood, beneath it should be one smaller wood, in order for the remaining wood faster light and in order for not produce extra smoke and pollute the environment. Basic: During the adding woods, handle for the primary air must be always open. After one and a half hour of burning, you can close the handle for the secondary air. FIREPLACE SHOULD NEVER BE FILLED EXCESSIVELY. EXCESSIVE AMOUNT OF FUEL OR AIR FOR COMBUSTION CAN CAUSE OVERHEAT AND DAMAGE THE FIREPLACE. 8