FDCL221-M Multi line separator module

Similar documents
Multi line separator module

FDCIO223 (ES 45) Transponder

FDCL221-Ex Line adapter (Ex)

Input module, input/output modules

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Input module, input/output module

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

Output module (230 V)

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDBZ290 Air sampling smoke detection kit

FDCL221 Line separator

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

ASA linear smoke detector

FDBZ290 Air sampling smoke detection kit

FC724 Fire control panel

OOH740, OOHC740 Automatic fire detectors

FC722 Fire control panel

DF1101-Ex Infrared flame detector

FC722 Fire control panel

FC724 Fire control panel

DC1192 Input /Output module

Mimic display driver, LED ribbon cable

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

FC723 Fire control panel

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

DM1131 / DM1133 / DM1134 Manual call points

FDCI221, FDCIO221 Input module, input/output module Technical Manual

Fire control panels FC726 FC726-XA

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

OH720, OP720, HI720, HI722

FC2020 Fire control panel

FDCW241 Radio gateway Mounting

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

Interbases. Sinteso FDSB221, FDSB228, FDSB229

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDOOT221, FDO221, FDT221

OOH740-A9-Ex Multi-sensor fire detector

FDOOT241-A9-Ex Multisensor fire detector

Fire control panels FC360

OOH740-A9-Ex Multisensor fire detector

SWING radio fire detection system

DF1151-Ex Infrared flame detector

FDL241-9 Linear smoke detector Mounting Commissioning

FC2040. Fire control panel. Sinteso. FS20 series, MP6

DT1101A / DT1102A / DO110xA Automatic fire detectors

FDA241, FDA221 Siemens ASD

FS20 Fire detection system

XC10 Extinguishing control panels

Sinteso TM product catalog.

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Fire control panel for modernization

Synova TM product catalog.

Building Technologies. FDUL221 en Line tester operating instructions for electricians

FP120-Z1 Power supply kit A (70 W) Technical Manual

DOW1171 / DCW1151 Radio fire detection system

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

FDA241, FDA221 Siemens ASD

Test units and accessories

Test units and accessories

Radio fire detection system

FT2080 Fire terminal (Touch) Mounting Installation

FDCIO223 Input/output module (transponder)

FDBZ290 Air sampling smoke detection kit Technical Manual

FDM273 Radio manual call point Mounting

FT2080 Fire terminal (Touch) Mounting Installation

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FDM221, FDM223, FDM224, FDM223H, FDM224H Manual call points

FDS229 Alarm sounder with supplementary optical indication Technical Manual

Test units and accessories

FDCIO223 Input / output module (transponder)

Room thermostat with 24-hour time switch and large LCD

Fire safety products and accessories siemens.com/cerberus

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

FD20 Sinteso Detector system

OH720, OP720, HI720, HI722 Automatic fire detectors Technical Manual

FS720 Fire detection system (marine) Technical Manual

XC10 combined fire detection and extinguishing control

Frost Protection Thermostat

XC10 combined fire detection and extinguishing control

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

FDUL221 Line tester Technical Manual

FDA241, FDA221 Aspirating Smoke Detector Technical Manual

OH110, OP110, HI110 Automatic fire detectors

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Duct Temperature Sensors

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FDOOT241-A9-Ex Automatic fire detector Technical Manual

Interface and EOL Modules 8

For internal use only. Distribution (please mark): Product Solution Multi-channel x

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Electronic timeswitch

FC700A Fire detection control unit

Transcription:

FDCL221-M Multi line separator module addressable (FDnet/C-NET) Sinteso TM Cerberus PRO Automatic module with several line separators Creation of T taps (stub lines) in the FDnet/C-NET Operation of the module in one or two loops Individual addressing for each line separator Status indication for each line separator with LED Communication via FDnet/C-NET (individual addressing) Simple installation and connection of the stub lines For installation in intermediate distributor or in fire control panel

Characteristics Environmental ecologically processing recyclable materials electronic und synthetic material simple separable Characteristics protected electronics built-in alarm indicators to signal line separation Multi line separator module Function The module has total 9 separators. Each separator is an 'electronic switch', which separates the negative conductor in case of a short circuit, so that the short circuitfree side can continue to be operated. In addition the module has connections for the detector lines (FDnet/C-NET loops) connections for the stub lines (T taps) jumpers for programming of operation mode (1 loop or 2 loop mode) yellow LED for the status indication (for the short circuit separation) Application To avoid the breakdown of several stub lines in case of a short circuit, line separators may be inserted. The multi line separator module is used where several stub lines are connected to the FDnet/C-NET at one point, if no other device is given between the T tap. The module can also be connection to 2 separate FDnet/C-NET loops at the application in 1-Loop operation 9 line separators are available 2-Loop operation 2 x 4 separators are available retrofitting of existing, collective systems to addressable Sinteso/Cerberus PRO fire detection systems Adhere to country-specific instructions Stub line (Sinteso) Connections stub lines (Plug 20-pin) Stub line (Cerberus PRO) FDnet/ C-NET Connection detector line 1 (FDnet/C-NET loop 1) Connection detector line 2 (FDnet/C-NET loop 2) Jumpers for configure operation mode 2

Installation The line separator can be integrated in the supply shaft on every floor in an intermediate distribution frame, or at the place of the collective control unit. When all stubs are guided individually to the collective control unit, insert the line separator directly in the new fire detection control unit. Installation screw directly onto plane surface area mounting on the top hat rail TS35 in housing FDCH221 with cover, seal and screws for wet applications Installation directly in switching cabinet / control panel Installation in separate housing FDCH221 Installation in range with enclosed mounting feeds at top U rail TS35 (vertical or horizontal) For shielding cables use connection terminals DBZ1190-AB Dimensions 36 24 132 48 119 207 102 90 Breakout for screwed cable gland and back nut M20 3

Technical data Operating voltage Operation current (quiescent) Number of separators DC 12 33 V 2.25 ma (9 x 250 μa) or 2 x 1 ma (4 x 250 μa) 9 with 1 loop 2 x 4 with 2 loops Operating temperature -25 +70 C Storage temperature -30 +75 C Humidity 95 % rel. Communication protocol FDnet/C-NET Connection terminals 0.2 1.5 mm 2 Color Housing Cover white, ~RAL 9010 transparent matt white, ~RAL 9010 Aux. housing FDCH221 Protection category EN 60529 / IEC 60529 IP30 with aux. housing FDCH221 IP65 Standards EN 54-17 Approvals VdS LPCB System compatibility FDnet C-NET G209162 531n/02 FS20, AlgoRex, SIGMASYS FS720 4

Details for ordering Type Part no Designation Weight FDCL221-M S54312-F6-A1 Multi line separator module 0.122 kg BPZ:5644780001 U-rail TS35, L=122 mm 0.040 kg BPZ:5644230001 U-rail TS35, L=288 mm 0.090 kg FDCH221 S54312-F3-A1 Housing with cover, seal and screws 0.280 kg A5Q00004478 Metal screwed cable gland M20 x 1.5 0.039 kg A5Q00004479 Back nut M20 0.006 kg DBZ1190-AB BPZ:4942340001 Connection terminal 1.0 2.5 mm² (3-pole) 0.002 kg Spare part FDCM291 A5Q00003855 Mounting feeds (25 pcs.) 0.060 kg Details see equipment overview 008164 (Sinteso), A6V10225323 (Cerberus PRO) Details about system compatibility see List of compatibility 008331 5

Siemens Switzerland Ltd Infrastructure & Cities Sector Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies 2014 Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability. Document no. A6V10230308_c_en_-- Manual FD20 / FD720 Edition 04.2014 Section 5 / 5