USE. Steam dispensing. n 4 holes. How to access the programming function

Similar documents
Type Sup 037RG. Errata: Descaling. These instructions replace those reported in the manual.

NL Installatievoorschriften p. 3. FR Instructions d installation p. 5. DE Montageanleitung p. 7. EN Operating and installation Instructions p.

HALO ELITE BIVVY LIGHT

CVEN x 1/1 GN 6-12 x 20 DEVICE FOR GASTRONOMY

05/2014. Mod: E99/PLA2-N. Production code: BEFT908L

Centrifugal electric pumps ATEX safety instructions

Elettropompe centrifughe Centrifugal electric pumps Electropompes centrifuges Fliehkraftpumpen Electrobombas centrífugas

Technical instructions

ADDITIONAL FLUE GAS DRAUGHT FAN ATTACK PV150 INSTRUCTIONS FOR USE

THERMAL RADIATORS INSTALLATION INSTRUCTIONS AND USER GUIDE RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF14P RF3E RF4E RF5E RF6E RF8E RF10E RF12E RF14E

SAITEK srl. Serie. < Automatic burner control unit > Casalgrande (RE) ITALY Tel Fax

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

104G / 204G / 304G Catalogue of Replacement Parts Catalogue de Pieces de Rechange Ersatzteilkatalog

INSTRUCTION MANUAL VARIABLE TEMPERATURE KETTLE MANUEL D UTILISATION BOULLOIRE À TEMPÉRATURE VARIABLE MANUAL DE USO HERVIDOR DE TEMPERATURA VARIABLE

IMESA: A LIFE BY YOUR SIDE

ATTACK DPX USER MANUAL. for correct installation, operation and cleaning WOOD GASIFYING BOILER STANDARD / PROFI / LAMBDA

Sirène flash. Sirena con lampeggiante DP8406 DP8407 DP8408. Alarmsirene mit Blitzlampe. Siren and flashing. p. 19

MLC 30. Bruksanvisning Brugsanvisning Bruksanvisning Käyttöohjeet Instruction manual Betriebsanweisung

Heliox UV. Model Heliox LP P Heliox LP P Heliox LP P300

TECHNICAL INFORMATION CVA 4062/CVA 4066/CVA 4068 Coffee Systems SERVICE MODE Miele USA

OC Series - Automatic coffee machines. OLC1 Lucia High performance liquid coffee dispenser. Users Handbook - 1 -

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO

ISTRUZIONI D USO PER L UTENTE OPERATING AND MAINTENANCE MANUAL MODE D EMPLOI ET D ENTRETIEN BEDIENUNGS UND WARTUNGSANLEITUNG

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780

STEAM TILTING KETTLES

SIRIO Contatore di energia Energy meter

Raffaello From serial number Group

Air-cooled heat pump USER MANUAL HBI IHBIFY _01

The future is in the air

BSR Addressable Fire Detection control panel. Installation operation manual

THIS INSTRUCTION BOOK MAY CONTAIN ERRORS AND OMISSIONS. DESIGN AND SPECIFICATION ARE SUBJECT TO CHANGE WITHOUT NOTICE.

Strand Lighting Inc Darin Way, Cypress, CA 90630, USA Tel: Fax:

Thermo CTP-E45T 0 Pot

USING AND MAINTENANCE MANUAL FOR SELF-CONTAINED POWER BRUSH MACHINE FOR CARPET AND HARD FLOOR. Elite-Silent. Elite-Silent

DESCALING INSTRUCTIONS for: CS220, CS200, CS100 Page 3 Cappucinatore CS20 Page 5 Gemini CS223 Page 6 Zenius ZN100 Page 7

Mini MP 170 V.V. Mini MP 220 V.V. Mini MP 170 Combi. Mini MP 220 Combi

INSTALLATION AND OPERATION MANUAL ISM-4081 INTEGRATED SHUTDOWN MODULE

TILTING KETTLES WITH MIXER BASKETT

Blixer 4 P.O. Box 16625, Jackson, MS

DESCALING INSTRUCTIONS For Professional/Out-of-Home Machines:

Compact wall hung boiler. Micro processor Brass Hydraulic set

Ηλεκτρικές επιτραπέζιες εστίες 41

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

DESCALING INSTRUCTIONS For Professional Machines:

DC200 Digital Dispenser Operating Manual

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

Rev D 3/20/17

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

RADIO WAVE WEEKLY PROGRAMMABLE THERMOSTAT CH150RF

INDICE. Installation recommendation

TAURA 24 MC W TOP AZIENDA CERTIFICATA ISO 9001

FLAVIA CREATION C500 User Guide

LB 4712 MAINTENANCE MANUAL FOR TECHNICAL ASSISTANCE

ADL DYNAMIC STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE ADL 2012 ADL 3018 ADL 4024 ADL 5030

Millo / Millo pro. Nr x000 / 1805-x000

Electric table-top hot-plates

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

ULTRASONIC HUMIDIFIER

Cedarbrook Sauna + Steam Family owned and operated since 1971

Thermostatic Heads TT3000 TT3000C TT /02/2018. Technical Data Sheet

INSTRUCTION MANUAL STAND MIXER MANUEL D UTILISATION BATTEUR SUR SOCLE MANUAL DE USO BATIDORA DE PIE EN FR FR ES

T14 AS1 T20 T40 T24. ISO 9001 Cert. N 0412/2 SERVICE MANUAL. Cod /0-03/ Rev. 000

Controllers for refrigeration EVBOX1

Carmen. Operating Instructions. 1

OilMatic Pro / 230 V AC

gebruiksaanwijzing user manual betriebsanleitung mode d'emploi

CONTENTS Introduction Information Services Getting Started Phone Directory Messages Optional Features Alerts Other Features

15x15 Diamantato White Lux 7,5x15 Diamantato White Lux 5x15 Cornice Liberty White Lux 2x15 Bullnose White Lux 11x15 Battiscopa 900 White Lux

SERIES PSCII GAS BOILERS

K 60 D 070 Z KIT RÉGULATION SYSTÈME POUR POMPE À CHALEUR INVERTER AVEC CHAUFFAGE D APPOINT ÉLECTRIQUE

MacDonald Steel Limited

AUTODIALER SYSTEM FOR LIFTS MANUAL HELPY 2W-V

MOD COD REV. 0 del 30/07/2013

USE AND MAINTENANCE MANUAL

Controllers for refrigeration EVBOX1 data-logging extension

Powers Controls Free Energy Band TH 193 HC Hesitation Room Thermostat

User Manual. Dryer Controller M720

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

P.N Rev A ELECTRIC HOT WATER DISPENSER User Manual BVSTWD7915 Series MODEL

benchtop collection Instructions for use and warranty details Capsule Coffee Machine Model No.: CMBT01N

manual modbar - steam system

MWR-n. MWR 5n MWR 10n MWR 20n. gebruiksaanwijzing user manual betriebsanleitung mode d'emploi

Tarifa de repuestos. Spare parts price list. Rociadores Rain Showers

Professional Cleaning Machines Since 1968 EN Use and Maintenance

POWERS 24 / 28 / 34 KW

EVM/A 16 F 3~ 50Hz CAMICIA ESTERNA Outer casing DISCO P/TENUTA Casing cover

IN NOURISHING SECURITY.

TOQUE BLANCHE GRANDE CARTE

SPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90

EGE Manisa 70 cm BIR Carinaro 55 cm. Fabriano June Presenter Francesco Nieli

INDEX. Installation recommendation

IWECO Models IWCO9, IWMlO, IW7l0, IWLlO, IW8l0. IW509 IWCO9 IW609 IWMlO IW7l0 IW709 IWLlO IW8l0. Medium. Compact 65 litres 58 litres

REVOLUTION. Ice Shaver/Blender Operation Manual (2) Râpe-glace/mélangeur Manuel d utilisation (14)

Introduction... 3 Setup & Suggestions... 4 Basic Use... 4 Setting Time... 4 Setting Temperature... 5 Setting Height / Pressure...

Ovens 200 series. The ovens 200 series

CANADA BREBES980XL 120V 60Hz 1800W First Sale Date: US BES980XL 120V 60Hz 1800W First Sale Date:

K-HA CENTRIFUGAL PRESSURE BOOSTING PUMPS. Technical Sheet

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT HCT-1000 User Guide

ECV SP GUE ALO CAT ICAL TECHN

Transcription:

TURBOSTEAM SERIE M

USE Steam dispensing Machines equipped with the TURBOSTEAM (STOP STEAM) dispensing system have the "stop steam dispensing when set temperature is reached" function, and can rapidly heat and froth milk. After selecting the type of milk you desire (heated or frothed), insert the steam nozzle () into a suitable container, making sure the bulb is completely immersed in the milk. Turn the automatic steam knob () in the appropriate direction. Once the set temperature is reached, steam dispensing can be stopped automatically or manually, as described in the paragraph "Programming the automatic steam knob". The turbosteam steam wand has a nozzle with four holes with a diameter of.75 mm. On request, a nozzle with holes with a diameter of mm is available and is the best solution for beverages that are less than 350 g. The nozzle with mm holes can be identified by the groove "S". S n 4 holes ø,75mm n 4 holes ø mm Standard nozzle Optional nozzle How to access the programming function The machine s program is memorized on the CPU - DISPLAY cards. The machine is programmed with a standard program in the factory. To read and change the set data the programming function is accessed as follows: Touch the sensor with the technician s key. The autosteam function is available in versions with a CPU 3,000 memory or higher.. Day Hour The sound of the buzzer indicates recognition of the key and the word TECHNICIAN appears on the display. Scroll through the boxes on the panel until you see: Option Steam stop: xxx C You may now program the automatic steam function, by setting a xxx C temperature value for either hot or whipped milk.

Automatic steam knob programming The automatic steam knob () can be programmed in two ways: MODE, STEAM AUTOMATIC STOP Set a temperature value on item "Stop steam xxx C", by using keys "+" and "-". The range for "xx" is from 55 C minimum to 85 C maximum Steam dispensing is controlled by the knob (). In particular: - when the knob is turned to the left, the milk is heated. - When the knob is turned to the right, the milk is frothed. Once the knob has been turned (), it automatically returns to the "O" position. Q P When the drink to be heated exceeds +55 C, the message "Stop steam xxx C" appears on the display - this indicates the temperature read by the probe. N.B.: When the set temperature is reached, steam supply stops automatically and the display continues indicating steam value for the next 5 minutes. Steam supply can be interrupted at any time (even if the set temperature was not reached), by again turning the automatic steam knob () in the same direction used for activating supply. MODE 2, STEAM MANUAL STOP Set the temperature value on item "Stop steam xxx C" at "000" zero. Steam dispensing and the choice of milk type are performed as in MODE Hot milk Frothed milk Turn the knob () and the message "Stop steam xxx C" immediately appears on the display, indicating the temperature read by the probe. Note: The user controls when steam dispensing is stopped. When the desired temperature is reached, the user will turn the automatic steam knob () in the same direction used to start the steam dispensing process. For the next 5" after steam dispensing has stopped, the display shows the milk temperature that has been reached. Time out is set at 80" for both the programming modes. A If, when the machine is powered up, the probe does not detect any temperature value (thermo-couple not operating), the STOP STEAM function is disabled and "----" is shown in the setting square instead of "xx C". The latest set temperature value is, however, saved until thermo-couple operation is restored. The machine works as if the STOP STEAM function does not exist. Frothed milk and hot milk are available, but the temperature read by the probe will not appear on the display. The ideal setting for milk frothing is set in the factory. If additional adjustments must be made, turn the flow adjustment valve (A) underneath the cup heating shelf on the right side of the machine: - counterclockwise: more air > more frothy milk - clockwise: less air > less frothy milk Note: even slight turns of the valve (A) can make a great difference in how the milk is frothed. Machines without display In machines without a display, the STOP STEAM function can only occur according to the procedure described in mode. The difference is that the temperature is set in the factory with the standard setting of 72 C (6 F), and is not set by the user. You must perform these preliminary operations to read or change set data: - Switch off the machine and set the DIP switch to ON, on the CPU card. - Connect the display card (cod. 445.87.000, with version memory 4-0-0-5 or successive) the programming keypad (cod. 445.032.000) the Flat cable (cod. 445.53.000) to the Y3 connecter of the AS Turbosteam card. - Switch on the machine, enter the programming phase using the special keypad and scroll through the display screens until the STOP STEAM function appears. - Change the setting so that it falls within the range of 55 85 C (3 85 F). Once the best setting is chosen, exit the programming phase. Switch off the machine. Disconnect the display card, programming keypad, and Flat cable from the Y3 connector of the AS Turbosteam card. Set the DIP switch to OFF on the CPU card, then switch on the machine.

Schema elettrico - Wiring diagram - Schéma éléctrique - Elektrischer Schaltplan - Esquema electrico - Esquéma electrico

Il Costruttore si riserva il diritto di modificare senza preavviso le caratteristiche delle apparecchiature presentate in questa pubblicazione Le Fabricant se réserve le droit de modifier sans préavis les caractéristiques des appareils présentés dans cette publication The Manufacturer reserves the right to modify the appliances presented in this publication without notice Der Hersteller behält sich das Recht vor, die in dieser Broschüre vorgelegten Geräte ohne Voranzeige zu ändern El Constructor se reserva el derecho de modificar sin preaviso las caracteristicas de las maquinas tratadas en este manual O Constructor reserva-se o direito de modificar sem aviso previo as máquinas tratadas neste manual 447-0 - 020 (rev. 03/04)