Silvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user -

Similar documents
Ventilator insert Silvento V... Installation directions - Please pass on to the user -

LUNOS Catalog For Home Ventilation. Feeling good at Home with LUNOS Ventilation Systems

Comfort Control TAC Operating Manual

Installation Manual Local Ventilation System with Heat Recovery Type e² and e² short

AirUnit. Installation instructions. mfh systems modern floor heating. Decentralised domestic ventilation

TEMPAIR 3 IN 1 EXHAUST FAN SKU# &

V-ZUG Ltd. Range hood. Levante. Operating instructions

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Installation Instructions

INDEX RECOMMENDATIONS AND SUGGESTIONS... 4 CHARACTERISTICS... 5 INSTALLATION... 6 USE... 9 MAINTENANCE... 11

InfraTec Premium. Assembly and operating instruction. 20 min. Made in Germany. Druck Nr en/ :00 20 C

RWC Issue: F. Description: ARISTON WALL CANOPY Model Numbers: ARCH90BIX. Model may vary slightly from images pictured. All measurements are in mm.

Operation Manual. Airbrush Airbrush-Spray Booth Compressor Suction Unit Paint E420

IMPORTANT SAFETY INSTRUCTIONS DANGER: WARNING:

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Stainless Steel Chimney Extractor

Installation and maintenance manual

energy-efficient The Catalogue

Installation Instructions

> ENGLISH VERSION. Instructions HERU 50 HERU / utg 2

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

LUNOS Domestic Ventilation Systems With Heat Recovery. Innovations for New Buildings and Redevelopment. e2 + e go

GB User and maintenance manual

OPERATING INSTRUCTIONS. Drying cabinet DC 7774 DC Read the instructions before using the machine.

Innes. Instruction Manual A Kichler Decor ceiling fan. Includes our new TM

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

Technical Concept. Plenum Integrated Filter Fan PIFF 3-AC PIFF 3-EC

* * EC1. Variable controller for circulation systems Mounting and operation manual

VC-1, VC-1-SL, VC-2-L, VC-2-SL

Lo-Carbon T-series Window & Roof Models

Operation Manual 322 KL

Operating Manual SEVi 160 Series

Instructions For Use ENG. LED Magnifier Lamp

Installation Instructions

LASER ASPIRATED SMOKE DETECTOR

360º Surface Mount Ceiling PIR Light Controller

Operating Instructions

Installation Instructions

Installation Instructions & Operating Manual IMPORTANT

Silhouette Installation and Wiring Instructions

Installation Instructions

7 Fin Oil Filled Radiator

MANUAL INTELLIVENT CELSIUS

Adjustable Electric Heater

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Lo-Carbon Quadra Centrifugal Fan

HOT WASHER MODEL NO: KING150

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Operating Instructions!

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

Decentralised comfort ventilation unit Zehnder ComfoSpot 50

Installation manual Mini Comfort 50 S/L 07/ V EN

Lo-Carbon Quadra SELV

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Bedienungsanleitung. Ideas for dental technology. Made in Germany C

TECHNICAL PROPERTIES OF THE APPLIANCE

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

LASER ASPIRATED SMOKE DETECTOR

Stainless Steel Chimney Extractor

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

Operating Instructions

Unity 180 Premium Whirlpool 180/80/62 cm

Suits all KPF849 models

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

Kitchen Appliance Lift INSTRUCTION MANUAL

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

OPTISENS TUR 2000 Technical Datasheet

INSTRUCTION MANUAL KOBOLD VC100 HANDHELD VACUUM CLEANER

GLASS DECORATIVE COOKER HOOD INSTRUCTION MANUAL READ AND SAVE THE MANUAL BEFORE INSTALLATION AND USE

Turbo. Service Instructions

30-pint Dehumidifier User Guide

BKA-EN Fire Damper. Additional operating instructions according to

CENTRIFUGAL CEILING EXTRACT FAN

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

CLIM9000CE PORTABLE AIR CONDITIONER USER MANUAL

2CDC D Product manual ABB i-bus KNX LGS/A 1.2 Air Quality Sensor with RTC

HEAT RECOVERY AIR HANDLING UNIT

ELECTRIC DRYER INSTALLATION INSTRUCTIONS

L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

COMPACT FLAME CONTROLLER CFC 100

IXL Eco Ventflo. User Guide. Model: (200mm) - Extraction Rate: 340m 3 /h Model: (250mm) - Extraction Rate: 490m 3 /h

Original instructions AR

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

T105 Advanced Remote Control Programmable Thermostat. User Manual

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

UP 258E11 OPTISENS OFFICE

Operating Manual. Combination Table Sealing Press. Series: Classic. CiMa-Pak Corporation Montreal Toronto New York. Telephone:

Imperial Electric Fires

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

FerronTM. Instruction Manual A Kichler Decor ceiling fan

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

Smart Smart IR. Service instruction SALES DATE MANUFACTURED ON (DATE): APPROVAL MARK SOLD. model (check applicable) is recognized as serviceable

Fan Air AIR EXTRACTOR & DEHUMIDIFIER SYSTEM

Transcription:

Silvento concealed variant clamped-ventilator - Replaces Skalar-; Skalar-V...; Skalar-2V... - Installation directions - Please pass on to the user - Contents: Notes on these installation instructions Safety precautions Technical specifications, waste disposal Dimensional drawings Possible installation positions Installation examples Parts supplied Dismounting Skalar and installation also in new constructions Electrical connection, wiring diagrams Run-out setting Filter change, cleaning Accessory and replacement parts Page: 1 1 2 3 3 4 5 5-7 8-9 10 10 10 Notes on these instructions Read these instructions carefully and completely prior to starting installation! The general safety precautions and safety symbols with notes in the text must be observed When installation has been completed, pass these directions on to the user (renter, owner, block manager or other) Symbols in these directions: This symbol warns on danger of injury This symbol warns on danger of injury by electricity Safety precautions Danger! Assembly work is only to be carried out on the ventilator when it is separated from the line voltage! The ventilator is protectively insulated to protective class II, the protective conductor is not needed! Caution! Electrical connection is only to be made by authorised skilled personnel and under observance of current VDE 0100 regulations of the German Electrical Engineering Association! Caution! This piece of equipment is not to be operated (filter change, cleaning) by children or persons who cannot operate it properly because of their physical, sensorial or mental ability, or their inexperience or lack of appropriate knowledge. Ventilators involved in off-air exhaust must always be supplied with a functioning flow-in of outside air. Ventilator Area 1 2.25 mm The German VDE 100 regulation permits installation in bath and shower room area 1. Ventilator installation as extractor hood is not permitted here Area 0 Area 2 1

Technical specifications Electrical connections Voltage supply: Control voltage (ventilator type FK): Protection class: Protection type: Admissable for use in area 1 of wet rooms 230 V AC 50 Hz 12 V DC II IP X4 General Silvento type Volumen flow Power consumption Soundpressure level Run-out time Interval Inverse operation Movement sensor Humidiy control range V 1) or KL 2) [m³/h] [W] [db(a)] [min.] [h] [% rh] 30/60/100 30/60/100 4.9/10.5/36.5 24/35/44 30/60B 30/60 4.9/10.5 24/35 yes 30/60ZII 30/60 4.9/10.5 24/35 6/ 15 3) 4 yes 30/60BZII 30/60 4.9/10.5 24/35 6/ 15 3) 4 yes yes 60ZII 60 10.5 35 6/ 15 3) 4 yes 60BZII 60 10.5 35 6/ 15 3) 4 yes yes 30/100ZII 30/100 4.9/36.5 35/44 6/ 15 3) 4 yes 30/100BZII 30/100 4.9/36.5 35/44 6/ 15 3) 4 yes yes 100ZII 100 36.5 44 6/ 15 3) 4 yes 100BZII 100 36.5 44 6/ 15 3) 4 yes yes 30-60 FK 30/40/50/60 5.3/7.2/8.9/10.9 24/27/32/35 50-70 Footnotes: 1) Silvento V units are ventilator inserts that additionally require either a concealed housing or surface-mount housing. 2) Silvento KL units are complete single pipe ventilators that are clamped in the curtain wall construction. Silvento KL single pipe ventilators fit in concealed housings of LUNOS Skalar versions. 3) The updated DIN 18017-3 requires the removal of a further 15 m³ air over the ventilation system after switching off the fan. 4) 30 min run-out time All ventilators are equipped with a Class G2 (EN 779) filter and a filter change display. Ventilators of the Silvento series fulfil all requirements: - of DIN 18017-3; Allgemeine Bauaufsichtliche Zulassung Z-51.1-215 - for low voltage (CE) acc. to EC Directives (2006/95/EG) - for electromagnetic compatibility (CE) acc. to EC Directives (2004/108/EG) Waste disposal Sort the packaging for appropriate disposal. Observe current requirements should you want to dispose of the ventilator. Within the framework of the Electrical and Electronic Device Act (ElektroG), the return of this device free of charge is guaranteed at your local turn-in center. 2

Dimensional drawings: Conical exhaust vent nozzle for DN 75 to DN 80 69 mm 32 mm Grip 1: bis 42 mm Grip 2: ab 57 mm No grip possible between 42 and 57 mm 260 mm 206 mm Break off the stems (2x) for installation un 3/LB and 3/LS housings 25,5 mm 120 mm Possible installation positioning for duct mounting Flap valve Through-the-wall housing Caution: Correct the flap valve position and seating if appropriate (see page 5) 3

Installation examples UP-Clamped-ventilators can replace all build-in versions of the Skalar series! These installation examples are therefore only a few of many possibilities Clamping housing only With Styrofoam housing Installation in housing 3/LS With fire-protected housing Installation in housing 3/LB 2-room ventilator Installation in housing 3/LS or 3/LB 2 4

Parts supplied Check delivery for completeness and undamaged condition! Slide nozzle with flap valve (for rising building) Seal (stick on when replacing a Skalar-V...) Ventilator insert for clampedventilator Filter Power supply terminal Front cover plate Pushbutton* Illuminated display* Sound insulation (not with 2-room ventilators) Incl. screws for connecting grid cover frame to ventilator insert *Illuminated display and pushbutton are located in the grid cover frame in case of fans with motion detector Grid cover frame Disassembly of Skalar and installation also in rising buildings Disassembly of Skalar 1 1.Make the ventilator dead. 2.Clap the front cover plate up. Unscrew the central screw. Take the cover frame off. 3.Unscrew the locking screws so far that the ventilator insert can be removed. If appropriate, draw the slide nozzle off. The slide nozzle is still on the flex tube. 4.Remove the power supply terminal from the ventilator unit. Remove the power supply terminal from the mains cable. 5.Take the flap valve out of the nozzle. Assembly 1a For installation in through-the-wall housings 3/LS, 3/LB, 3/LS 2, 3/LB 2: Adhere the seal that is supplied to the ventilator insert exhaust vent opening (remove protective film + stick on) Connection to the main line Connect flex tube to the main line Fix the slide nozzle to the flex tube Seal connections with adhesive tape or circlips 1b DN 80 Flex tube (75) approx. 50-100 cm Main line Make the wall cut-out Mount the curtain wall facing Fix the flex tube and mains cable in the wall opening in easy reach DN 75 DN 80 Widt h 21 cm Height 23 Installation of clamped-ventilator Exhaust nozzle 5

Mains Connection: Fasten the power supply terminal to the mains cable as shown in the appropriate wiring diagram (see Wiring diagrams ). Caution! The mains cable must be dead! 2 Top view of power supply terminal L2 L1 L N F+ F- Plug the power supply terminal on and latch on behind the notched hook 3 Lock the power supply terminal in behind the notched hook Fit the clamped-ventilator insert in the wall cut-out: Insert the ventilator unit in the wall cut-out (correct flap valve position and seating if appropriate! See the bottom diagram) 4a Push the exhaust nozzle on to the stop Insertion in through-the-wall housings 3/LS, 3/LB, 3/LS 2, 3/LB 2: Push the ventilator unit in the through-thewall housing while pressing the mains cable back in the duct 4b Stick seal to exhaust opening (see diagram 1 )! Duct Mains cable Break off the guide stems Installation housing Correct the flap valve position and seating (important for ceiling installation) In the installed condition, the flap valve in the exhaust nozzle must close because of its own weight. The flap valve can be drawn out from the inside for corrections. Right DOWN inscription Wrong Flap valve Correction 6

Fixing the ventilator insert Screw the fixing screws moderately tight with a screwdriver The clamps come out automatically and lay themselves from behind at the curtain wall facing or in the recesses in the plaster frame of housings 3/LS, 3/LB, 3/LS 2 and 3/LB 2 With a through-the-wall housing, screwfastening can be made using the flange boreholes in the plaster frame. Screws + accessories are not supplied for this. 5 Flange boreholes (4 x) Clamp Decor plate assembly: Fix and align the grid cover frame to the ventilator insert with the screws supplied Insert the filter Set on and lock the front cover plate 6 Front cover plate Filter Caution! Always install the grid cover frame and front cover plate according to the built-in position of the ventilator Grid cover frame Fitting the motion-detector circuit board to the decor plate : Plug the display board cable in Fasten the grid cover frame to the ventilator insert with the screws supplied and align it so that the cable lies under the motiondetector circuit board (do not clamp it in) Insert the filter Put on and lock the front cover plate Plug in motion-detector circuit board: Coupling Plug Motion-detector circuit board plugged in: Motion-detector circuit board plugged in and cables for motiondetector circuit board plugged in correctly Motion-detector circuit board Plug with coupling Cable for motiondetector circuit board Front cover plate Control Grid cover frame 7

Electrical connections - Wiring diagrams Safety Precautions: Caution! Carry out installation work on the ventilator only when it is separated from the mains voltage! The ventilator is protectively insulated according to protective class II, the protective conductor connection is not needed. Ensure that all connecting cables to the ventilator are dead before connecting it! (Separate from the mains with at least a 3 mm contact space, e.g. electric fuse). Each circuit belonging to the ventilator must be equipped with fault current protection (e.g. FI switch). Electrical connection only by an electrician! Additional installations and/or electrical components are not permitted! Wiring diagrams for further ventilator functions on request! L N 1 One-step operation, switchable to 60 m 3 /h (Ventilator types... 30/60) Room illumination 2 Continuous operation 30 m 3 /h, switchable to 60m 3 /h or 3 100 m 3 /h (Ventilator types... 30/60) Run-out time controlled 60 m 3 /h or 100 m 3 /h (Ventilator types... 60ZII;... 100ZII) Continuous operation 30 m 3 /h, with switchable run-out time controlled 60m 3 /h or 100 m 3 /h (Ventilator types... 30/60ZII;... 30/100ZII) With movement detector Note: For all circuits with movement detector (Ventilator types 60BZII;... 100BZII; 30/60BZII;...30/100BZII; 30/60B) Room illumination 100 m 3 /h (instead of L1 to L2) only with ventilator type 30/60) 4 Two-step operation, switchable to 60 m 3 /h and 100 m 3 /h 5 ON/OFF (Ventilator types... 30/60) Three-step operation, continuous operation 30 m 3 /h, switchable to 60 m 3 /h and 100 m 3 /h (Ventilator types... 30/60) Note: Connection to light not possible Room illumination 2 2 6 With remote control (ventilator types... F) Note: Other circuits, e.g. via L1 or L2, are possible. Remote control always has priority 0 2 V: > 2 4 V: > 4 6 V: > 6 8 V: > 8 10 V: > 10 12 V: Ventilator operation acc. to switch position Ventilator OFF 30 m³/h 40 m³/h 50 m³/h 60 m³/h 7 Two-room ventilator with run-out time: Run-out time controlled 100 m 3 /h, switch-off in each of 2 rooms (Ventilator types... 100ZII) Continuous operation 40 m 3 /h with run-out time controlled 100 m 3 /h, switch-off in each of 2 rooms (Ventilator types... 30/100ZII) Room 1 60 m³/h Room 2 40 m³/h 8

8 Humidity control (ventilator types...fk) Caution! Ventilators with humidity control optimally adjust the exhaust air volume flow by means of the room air humidity and temperature Room illumination Switch LUNOS type 2 FK Order no.: 039 840 Switch 2 FK (front view) Rocker switch function description S l: The fan has an automatic summer/winter switchover. The illuminated display lights up green with active humidity control and red with clogged filter. The fan runs from May to September in summer operation and from October to April in winter operation. Using an integrated supply-voltage-independent clock, the fan "knows" which month it is. During the cold season and the transitional period, an excess humidification of the apartment is prevented and thus building damage and mold avoided. The system is controlled automatically and, by means of continuous adaptation of the exhaust air volume flow to the room air humidity and room temperature, it guarantees optimum comfort in the room to be ventilated. In this way, only as much ventilation as necessary, but as little ventilation as possible, is ensured and thus energy is saved. The fan never switches off completely in order to ensure a minimum air change. During summer months, the increased exterior air humidity does not make an increased level of ventilation appropriate. The automatic summer/winter changeover is overridden by operation with the rocker switch Sl of the switch 2 FK. LOWERING OPERATION: Volume flow 30 m³/h, independent of the room air humidity and room temperature; function active only in the "winter months" October to April HUMIDITY CONTROL: Volume flow 30/40/50/60 m³/h, humidity control active; function active only in the "winter months" October to April. Rocker switch function description S II: Required ventilation ON: Volume flow 60 m³/h, possible coupling of the light level. The ventilation with 60 m³/h, by means of a priority control circuit, overrides the operating modes "Lowering operation" and "Humidity control", as well as the automatic summer/ winter changeover. Required ventilation OFF: Fan runs in automatic summer/winter operation according to setting of the rocker switch S I. Remote control: Ventilator type... FK is remote controllable via the F+ and F- connections and with 0 to 12 V. 0 2 V: Ventilator operation according to the mains connection; > 2 4 V: ventilator OFF; > 4 6 V: 30 m 3 /h; > 6 8 V: 40 m 3 /h; >8 10 V: 50 m 3 /h; > 10 12 V: 60 m 3 /h Temperature switch-off: The ventilator switches off when the room temperature drops below 15 C for more than 1 hour and so helps to avoid freezing of the heating. When 17 C is exceeded, it switches on again. Note: LUNOS standardly supplies an adhesive label set for marking switch positions when series switches from an installation-switch manufacturer are used. 9 Two room ventilator 10 Two room ventilator One step operation, switchable to 100 m 3 /h from two rooms (ventilator type... 30/60) Continuous operation 60 m 3 /h, switchable to 100 m 3 /h from two rooms (ventilator type... 30/60) Room illumination Room illumination Room 1 60 m³/h Room 2 40 m³/h Room 1 40 or 60 m³/h Room 2 20 or 40 m³/h 9

Run-out time setting: For ventilators with run-out time 5/ZII Cap White toggle switch Interval ON every 4 hrs for 30 min * Interval OFF Run-out time 15 min Remove cap with a screwdriver Run-out time 6 min Electrics housing Inverse operation 30 min after rundown after the room is left * Inverse operation OFF Caution! Only adjust the switch when ventilator is in the dead condition! Factory settings : Switch-on delay 120 sec Run-out time 15 min Inverse operation OFF Interval switching OFF Switch-on delay 120 sec To change settings: 1. Take the front cover plate off 2. Draw the cap off of the electrics housing 3. Make the wanted settings 4. Re-assemble in the opposite succession Switch-on delay 0 sec * Independent of the set adjusted run-out time Filter change Ventilator with movement detector: Button and illuminated display are in the grid cover frame Ventilator with step switching, run-out time or humidity control: Button and illuminated display are in the electrics housing Continuous red light up of Grid cover frame Filter Illuminated display Button illuminated display indicates a dirty filter Take of the front cover plate, remove filter. Insert new or cleaned filter. Dirty filters can be cleaned, e.g. in a washing machine. Operate button for 3 seconds with a pencil or similar to turn off the display illumination Replace the front cover plate Never operate the system without a filter! Illuminated display Button Front cover plate Cleaning Wipe the front cover plate and grid cover frame with a dry, soft cloth when appropriate. Filter change and cleaning are not to be carried out by children or people who cannot manage this with certainty because of their physical, sensorial or mental ability, or their inexperience or lack of appropriate knowledge Accessory and replacement parts LUNOS Lüftungstechnik GmbH für Raumluftsysteme Wilhelmstr. 31-34 13593 Berlin Germany 10 2/FSI-R 2/S 2/SB Tel.: Fax: 0 30 / 36 20 01-0 0 30 / 36 20 01-89 Order no. Order no. Order no. Mail: Site: 039 721 039 551 039 578 info@lunos.de http://www.lunos.de E 128/05.11 Filter, pack of 3 Silvento decor plate incl. filter display Silvento decor plate with movement detector