SERIES WM-20(T) & WM-40(T)

Similar documents
Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Beacon 800 Gas Monitor Operator s Manual

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Beacon 410A Gas Monitor Operator s Manual

User s Manual. For the SHORE POWER CONNECTION MONITOR MODEL 9151

INSTALLATION GUIDE

Pioneer-R16 Gas Monitor Operator s Manual

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Beacon 110 Gas Monitor Operator s Manual

VIZOR Electronic Dry Pipe Accelerator (EDPA) Quick-Opening Device for Dry Pipe Systems General Description

Check It Panel. 1 Phase Simplex Demand Dose Operation, Maintenance & Installation Manual. Introduction. Safety Guidelines

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Public Safety DAS Annunciator Panel

Model 17A00 Expansion Enclosure

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description.

Crypto-Lock. Model CC-8521B Updated 7/17. Access Control System. MONITEQ, Inc. INSTRUCTION MANUAL

Installation, Operating and Maintenance Manual

RAPID RESPONSE Model RCP-1 Residential Control Panel 1 or 1-1/2 Inch (DN25 or DN40), 175 psi (12,1 bar) General Description

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

ESP TECHNOLOGIES LIMITED

DH500ACDC Intelligent Air Duct Smoke Detector Housing

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

GasScanner 1C. Single Channel Monitor. Operator s Manual. MINT-0278-XX Rev A

CM800 Emergency Call System

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

UVS & UVE REMOTE LAMP AIR DISINFECTION SYSTEMS OWNERS GUIDE

/ SENSOR CABLE / CEILING GUARD

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

DH100ACDCI Ionization Air Duct Smoke Detector

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Analog Room Pressure Monitor RPC Series

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

DISCOVERY Instruction Manual Model #2556

MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. MODELS A/B INSTALLATION MANUAL

PO Box 827 Hawley, MN (218) Fax (218)

631RF Amp Power Supply

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

CARD ACCESS CONTROL SYSTEM

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Model 4001 Series Single Channel Controller

MEGA. cal electronic gas alarm. Installation, Operation, and Maintenance Instructions. Part No Rev. D Pg.

Safe T Net 210. Instruction Manual Part Number Mar2010

HALOGUARD TM IR MONITOR (OPTIONAL) FOUR or EIGHT POINT SCANNER INSTRUCTION MANUAL

Lightning Warning System: LWS MK-II. User's Guide. KOREA EMI Technologies Co.,Ltd , Jangam-ri, Majang-myeon, Icheon-si, Gyeonggi-do, Korea

M770 ph Controller Owner s Manual

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

DH100ACDCI Ionization Air Duct Smoke Detector

AIR MASSAGE KIT INSTALLATION INSTRUCTIONS

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

4 & 8-POINT ANNUNCIATORS Instruction Manual

SFC-200 SERIES LED FIRE ALARM PANEL

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

ph COOLING TOWER CONTROLLER

Cookson Company 1901 South Litchfield Road Goodyear, AZ Phone:

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

LMA LINE MONITOR ALERT USER S MANUAL

Intelligent Security & Fire Ltd

EVO192 v3.0 Fire and Burglary What s New

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

DH100ACDCLP Air Duct Smoke Detector with Extended Air Speed Range

SECTION LIGHTING CONTROL DEVICES

MODEL B2 INSTALLATION MANUAL

Always make sure to check the heating film before, during, and after installation of the floor covering.

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Axiom Technologies L.L.C Telephone: Pennbright Dr., Suite 220 Fax: XP7 USER S MANUAL

Installation Instructions

Duct and Rough Service Carbon Monoxide Sensor

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

ELECTRICAL SUPPLIES NATIONAL REFRIGERATION PRODUCTS WIRE NUTS HEAT SHRINK TUBING CABLE STAPLES CABLE MARKERS

INSTALLATION AND OPERATING INSTRUCTIONS. For Reliance Controls Emergency Power Transfer Switch Kit Model Number 30216BRK

CEILING FAN OWNER'S MANUAL

Noby-448 User Operating Manual & Log Book Page 1 of 12. Fire Control Panel. User Operating Manual & Log Book

CEILING FAN OWNER'S MANUAL

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

SECTION LOW VOLTAGE LIGHTING CONTROLS

Control Panel User Guide

Transcription:

SERIES 2100 - WM-20(T) & WM-40(T) Installation and Operation Instructions R LEAK DETECTION SYSTEMS MADE IN USA Dorlen Products Inc. 6615 West Layton Avenue, Milwaukee, WI 53220 Phone: 1-800-533-6392 Fax: 414-282-5670 E-mail: dorlen@execpc.com WWW.WATERALERT.COM 8/02

SECTION 1: PRE-TEST & MONITOR SETUP CHOOSING A LOCATION FOR THE MONITOR The location of the Monitor depends on many factors such as physical space, electrical requirements and whether or not the Monitor needs to be in a 24 hour manned environment. Wherever the Monitor is to be located, all models need 120VAC power. The WM-20(T), WM-40(T) need to be hardwired into 120VAC power. NOTE: ALL SERIES 2100 MONITORS DRAW A MAXIMUM OF 0.1 AMPS. PRE-TESTING Before mounting the Monitor panel, it is advisable that the system be powered and tested. This is to insure that all electronics are working properly and that the installer is completely familiar with how the system operates before proceeding. Unpack the Monitor and detectors; ONE detector has a sample cable for the pre-test (Wall mount units also have a AC line cord for the pre-test). See page 4 for information on connecting the detectors and page 6 for guidelines on testing the system. When the test is complete, disconnect the detector and put it aside - for now, leave the sample cable/detector combination in the state it was in when shipped. MOUNTING THE MONITOR Mounting procedure: 1. Using the supplied masonry and/or plaster/wood hardware, mount the enclosure in the designated location. The cabinet itself can be used to mark mounting holes. 2. Install the surface wire duct (5 ft. Section) to the duct opening connector on the bottom right of the monitor- (duct cover must be removed). Loosen screws A-A, and slide wire duct onto duct connector (C). Tighten srews A-A and install supplied screws for holes C-C ( Taped on channel duct) SEE Page 2. 3. Run 3 conductor armored (BX) cable for 120VAC power (provided) through the newly installed surface duct and into the monitor enclosure. Follow the wiring instructions on the next page. 1

120VAC Input White Ground Black Wire entry battery MONITOR A C A Channel Duct (Cover Removed) DRG. A-9833 120VAC WIRING 0 90 Elbow Armored cable fitting Hole D Not required if used on raised computer floors 1/2 conduit fitting C C Raised floor installation Channel duct penetrates floor ~ 2" (Armored cable runs to Junction box Below Raised floor, 120VAC) Concrete floor installation Channel duct stops above floor ~1" ( Armored cable runs to elbow supplied, Hole D, 1/2 conduit entry 120VAC) 2

SS-2100 WATER ALERT DETECTOR RUNS Each SS-2100 detector is connected to the monitor panel be means of a single, low voltage cable (Dorlen Type D). The detector "home-run" cable starts at a SS-2100 detector and terminates at the monitor panel - see Page 5. There are several different ways to run the subfloor wires to the location of the Monitor. Wire drops, conduit, surface duct material (provided) and other methods are all feasible. SECTION 2: SYSTEM TEST VERIFICATION This System Test Verification section assumes that the,detector hook-up, home-run wiring and connections to the Monitor has been completed. DESCRIPTION OF SERIES 2100 MONITORS 1. Provides power to connected SS-2100 Water Alert detectors. 2. Individual LED indication by zone of water leakage [WATER SENSED] 3. Provides zone selectable test signal to detectors. Verifies functions of Water Leakage Sensed Wiring. 4. Upon any leakage detect condition, monitor provides contact closure (DPDT) for connection to existing security panel.. 5. Unit provides LED display, audible alarm, SILENCE switch, TEST push button(s), RESET switch and RELAY DEFEAT switch [WM-20(T) / WM-40(T) only ]. 6. System has rechargeable battery back-up...provides 2 days of monitoring in the event of AC line failure...battery recharges upon AC line return. DESCRIPTION OF SS-2100 DETECTOR 1. Continually monitors floor/surface for water leakage. Internal buzzer sounds upon leakage detection and signal provided to connected Monitor Panel. 2. Detector is testable from Dorlen Monitor Panel. 3. SS-2100 features: a. Powered from Dorlen Monitor Panel b. Housed in compact molded housing c. Solid State Piezo-Electric buzzer d. Encapsulated circuitry, unaffected by moisture, dirt, humidity, long term operation, etc. e. Wire Nut connections to Monitor Panel Cable ( D Cable). 3

Wiring of SS -2100 W ater Alerts and O A-2100 O il Alerts to W M-20/40(T) SE RIES 2100 Monitor. TEST RED OVERLAY INSIDE WM-20/40(T) BLK RED GRN BLK RED GRN 5 Poistion Terminal Block (Positions 4-5 not used) Wire all channels similarly... Water Alert Model: SS-2100 or Oil Alert Model: OA-2100 B3 2500' Max. Wire Nuts Green Black Red WATER ALERT SS-2100 DORLEN PRODUCTS MILWAUKEE, WI. 53220 WATER ALERT Dorlen Products Milw, WI. 3 conductor, #22 AWG Dorlen type "D" If wire is shielded, tie shield to"b" lead at the Monitor location. B1 B2 Alert Bottom View 8-02 A-9834 4

MONITOR OPERATION - WM-20/40(T) FRONT PANEL - WALL MOUNT When the system is monitoring, the green "System Monitoring" LED will continually flash. Should AC power fail, the system will continue to monitor for a minimum of two days on the internal rechargeable battery. When AC line power returns, the batteries will automatically recharge (6 hours typical full recharge time). Should any zone detect water, the red "Water Sensed" lamp will flash. Alarm condition will cause the audible buzzer on the front panel to activate (unless the adjacent switch is in the "Silence" position). INTERNAL CONTROLS - WALL MOUNT The red plastic overlays should have marker pen zone locations indicated. Associated with each zone is a red LED (below the overlay) which indicate, by zone, "Water Sense". There is also a red recessed "Test" push-button associated with adjacent groups of TWO zones. At the bottom of the enclosure is the Master Control Box. From left to right, these items are: Fuse #1, 1/2 amp 120 VAC side of line Fuse #2, 2 amp Low voltage side of circuit "AC" Supplies AC power to system (apply before "BATT") "BATT" Applies Battery back-up power to system "RESET" If, as a result of the push-button "TEST" or an actual alarm condition) the system is activated, the reset switch will reset the system. If the alarm condition still exists, the system will reactivate. "RELAY DEFEAT" When testing the system by means of the red push button, it may be desirable not to activate the relays. If this is the case, depress and hold the "RELAY DEFEAT" switch on the left side of the Master Control panel. As long as the switch is depressed, the relays will remain in their LAST state and they will transfer to the monitors CURRENT state (activated or not) when the switch is let go. "RELAYS" There are double-pole-double-throw isolated relays which indicate "WATER SENSE" which are common to all channels. The LED's associated with each relay indicate when the relay is activated (i.e., alarm condition). These DPDT contacts are rated 28V at 1 amp resistive (200V MAX). Before applying AC power, visually check the wiring connection at each orange connector against the color coding indicated on the red panel overlays. Correct any wring errors...be sure the uninsulated shield wire connects to the black connection only. 5

POWER ON - Apply AC power to the system by switching the "AC" switch to on. The green front panel System Monitoring" LED should indicate (flashing)...if any other front panel lights or internal LED's indicate depress the "Reset" switch. Connect the back-up battery after AC power is applied by means of the "BATT-ON" switch. No change in any indication should occur. MANUAL TEST- Push and hold the recessed red "Test" push-button for at least 1 second: If an SS-2100 Water Alert detector is connected to the zone, the Water Sense LED should light. The momentary Test push-button operation causes the zone alarm to latch. This is desirable because a momentary or intermittent water leak is then "latched" until manually reset. Since many small leaks occur at night when water pressure is high, the latch feature aids in early detection. Proceed with the manual testing across each row. The relays will also activate and latch during the test procedure unless the "RELAY DEFEAT" is held depressed during the test procedure. NOTE: Pushing the Test push-button sends a signal to the SS-2100 detectors. A properly working detector will send back signals to the monitor. The 2 detectors in the zone that is being tested will alarm while the Test push button is depressed. Note that if NO detector is connected to a particular zone, NO LED's or buzzers should activate for that zone. If any zone connected to a SS-2100 fails to respond properly to the manual test, check the wiring at the associated terminal strip and if necessary, the wire nut connections in the SS-2100 detector. After all zones are tested and proper results obtained, the system is properly monitoring. If proper results are not achieved, call Dorlen Products, toll-free 1-800-533-6392 for technical assistance. 6

SECTION 3: MAINTENANCE AND TROUBLESHOOTING Once the system is installed and tested per these instructions, One may want to retest the system after a few months or at some routine schedule to verify proper system operation. In the unlikely event that the system fails to perform properly, please refer to Trouble shooting below. TROUBLE SHOOTING If a particular channel fails to respond to the "Manual Test" or "System Monitoring" green LED fails to flash, proceed as follows: 1. Verify Monitor is getting 120VAC power. 2. Verify that all wires connected to the terminal strips are tightly connected and no loose wire strands exist. 3. Remove AC power and switch the battery switch to "OFF". Check that the wire nut connections inside the SS-2100 detector of the defective channel are intact. 4. Check the two fuses located on the Monitor Control Box. 5. If the above does not indicate cause of problem, call Dorlen Products at 1-800-533-6392 for assistance. If you have installation questions, call toll free 1-800-533-6392 6-03 M-9868 7